To evaluate the therapeutic effect of a modified Devine procedure with a subcutaneous sliding fixation method for the treatment of congenital concealed penis,we retrospectively selected 45 patients with congenital con...To evaluate the therapeutic effect of a modified Devine procedure with a subcutaneous sliding fixation method for the treatment of congenital concealed penis,we retrospectively selected 45 patients with congenital concealed penises who were admitted to General Hospital of Ningxia Medical University(Yinchuan,China)between September 2020 and November 2023.In all cases,the penis was observed to be short,and retracting the skin at the base revealed a normal penile body,which immediately returned to its original position upon release.All patients underwent the modified Devine procedure with subcutaneous sliding fixation and completed a 12-week postoperative follow-up.A statistically significant increase in penile length was observed postoperatively,with the median length increasing from 4.0(interquartile range[IQR]:3.5–4.8;95%confidence interval[CI]:3.9–4.4)cm to 8.0(IQR:7.8–8.0;95%CI:7.7–7.9)cm,with P<0.001.The parents were satisfied with the outcomes,including increased penile length,improved hygiene,and enhanced esthetics.Except for mild foreskin edema in all cases,no complications(such as infections,skin necrosis,or penile retraction)were observed.The edema was resolved within 4 weeks after the operation.This study demonstrates that the modified Devine procedure utilizing the subcutaneous sliding fixation method yields excellent outcomes with minimal postoperative complications,reduced penile retraction,and high satisfaction rates among patients and their families.展开更多
Objective Laparoscopic surgery has become a routine general surgery with many advantages,such as alleviating abdominal pain.However,postoperative pain caused by abdominal drainage tubes has attracted little attention ...Objective Laparoscopic surgery has become a routine general surgery with many advantages,such as alleviating abdominal pain.However,postoperative pain caused by abdominal drainage tubes has attracted little attention from medical staff.The aim of this study was to explore the influence of a new abdominal drainage tube fixation method for 3-port laparoscopic cholecystectomy(LC)on patients’postoperative quality of life.Methods Patients who underwent 3-port LC with abdominal drainage tubes in the Department of Hepatobiliary Surgery of Linyi People’s Hospital from March 1,2023 to October 31,2023 due to gallstones with chronic cholecystitis were selected for this study.The patients were randomly divided into an experimental group and a control group.In the experimental group,the new abdominal drainage tube fixation method was used,while in the control group,the traditional method was used.Afterward,the quality of life of patient in terms of pain,activity,recovery time,and mental health status was evaluated.The exudate around the patient’s drainage tube was collected for bacterial culture and analysis.Results A total of 139 patients were randomly divided into an experimental group(70 patients)and a control group(69 patients).The patients’baseline characteristics were not significantly different.The patients in the experimental group had better outcomes in quality of life,with higher pain scores(24.03±2.37 vs.15.48±2.29,p<0.001)and activity scores(20.57±1.78 vs.14.13±1.43,p<0.001),and a shorter postoperative recovery time(2.36±0.68 d vs.2.96±1.34 d,p<0.001).The same results were shown in linear regression analysis scores of the 2 groups.The positive rate of bacterial culture in the exudate around the patient’s drainage tube in the experimental group was significantly lower than that in the control group(12.9%vs.43.5%,p<0.001);and furthermore,the positive rate of conditional pathogenic bacteria was even lower(7.1%vs.33.3%,p<0.001)in the experimental group than in the control group.Conclusion This new abdominal drainage tube fixation method can effectively promote patient rehabilitation and improve the quality of life for patient following 3-port LC with abdominal drainage tubes.展开更多
Carbon dioxide fixation technique was developed as an alternative dechlorination method of chlorobenzenes. Electrolysis of chlorobenzene was carried out in a one-compartment cell fitted with an aluminium anode and a p...Carbon dioxide fixation technique was developed as an alternative dechlorination method of chlorobenzenes. Electrolysis of chlorobenzene was carried out in a one-compartment cell fitted with an aluminium anode and a platinum cathode. Electrolysis in N, N-dimethylformamide (DMF) solution containing 0.1 M of tetrapropylammonium bromide (TPAB) at 0 ℃, 100 ml/min of CO2 flow rate and 120 mA/cm^2 of current density was found to be the optimum conditions of this electrocarboxylation, which gave 72% yield of benzoic acid from chlorobenzene. These conditions were then applied to 1,2-dichlorobenzene and 1,3-dichlorobenzene in order to convert them to their corrcsponding benzoic acids.展开更多
Objective To measure the tensile strength of the normal medial patellofemoral ligament(MPFL),and evaluate the biomechanics of different fixation methods of the hamstring tendon graft on the patella.Methods Eight fresh...Objective To measure the tensile strength of the normal medial patellofemoral ligament(MPFL),and evaluate the biomechanics of different fixation methods of the hamstring tendon graft on the patella.Methods Eight fresh cadaver knees were prepared by isolating the patella,leaving only the MPFL as its attachment to the medial condyle of femur.The MPFL was reconstructed by three different methods:four-suture fixation,anchors-single suture fixation,and anchors-double suture fixation.The tensile strength and the elongation of the normal MPFL and the tendon grafts were measured.Results The tensile strength of the four-suture fixation group(234.86±49.02 N)was stronger than that of the normal MPFL(146.91±25.30 N,P=0.0014)and the anchors-single suture group(159.17±49.07N,P=0.0077),while weaker than that of the anchors-double suture group(314.74±78.46 N,P=0.0052)Conclusions With regard to the tensile strength,the four-suture fixation method is reliable for clinical use.Compared with the anchor-suture method,the four-suture fixation method which has no specific implants is more economical,convenient and efficient.展开更多
Wafer curvature method has been applied to determine the internal stress in the films using Stoney's equation.During the film deposition,the wafer fixation on the sample holder will restrict the deformation of the re...Wafer curvature method has been applied to determine the internal stress in the films using Stoney's equation.During the film deposition,the wafer fixation on the sample holder will restrict the deformation of the rectangle-shaped wafer,which may result in the stress datum difference along length and width direction.In this paper,the effect of wafer size and the wafer fixation on the TiN film internal stress measured by wafer curvature method was discussed.The rectangle-shaped wafers with different length/width ratios(L/W=1:1,2:1,3:1 and 4:1) were fixed as a cantilever beam.After the TiN films deposition,the profiles of the film/wafer were measured using a stylus profilometer and then the internal stress was calculated using the Stoney equation in the film.The results showed that the fixed end of the wafers limited to some degree the curvature of the wafers along the width direction.For film internal stress measured by wafer curvature method,the wafer profile should be scanned along the length direction and the scan distance should be greater than or equal to half of wafer length.When the length/width ratio of the wafer reached 3:1,the wafer curvature and the calculated stress were basically the same at different positions along the length direction.For film internal stress measured by wafer curvature method,it was recommended that the length/width ratio of wafer should be considered to be greater than or equal to 3:1,and the deformed profile was scanned along the length direction.展开更多
Comminuted fractures of the humerus are generally treated with the intramedullary rod fixed by screws or locking plate system,and clinical results are satisfactory.We also know very well that the success of this agric...Comminuted fractures of the humerus are generally treated with the intramedullary rod fixed by screws or locking plate system,and clinical results are satisfactory.We also know very well that the success of this agriculture depends on the stability and adaptability and integration of the bone tissue of the humerus with this nail in the long term,with less and optimal distribution of stress in the surrounding bone.For this reason,we began to think and look for rational solutions to reduce and minimize this stress which has become an important issue in this area.In this regard,we have proposed a new model of hollow nail made of titanium proposed by some scientific specialists in this field of biomechanics,and we inserted from the proximal humeral head,and to ensure the stability of the nail inside the bone and prevent slippage,we attached small screws.To know the extent of the realization of these nails under the influence of the forces applied to them,finite elements in three dimensions as well as the program ANSYS Workbench 16.2 were used.Two intramedullary rods were instrumented in the finite element model of a medial humeral fracture.Axial,shear,and rotational loads were applied to the models under normal and osteoporotic bone conditions.The whole simulation was repeated 5 times for each fixator.To evaluate the biomechanical characteristics,the distribution of von Mises stresses and strains,total displacement in the nail,cortical and cancellous bone were compared.The numerical results showed that the intramedullary rod system with 4 screws and 6 screws played a very important role in the absorption and thus minimization of stresses.On the other hand,the nailing system fixed with screws was too great a role in reducing the stress compared to intact model.In general,the new model nailing system secured with screws gave a lower level of von Mises stress and strain at the cortical and cancellous bone of the humerus compared to the intact model.The results provided a theoretical basis for the selection of an appropriate surgical model.展开更多
Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in ou...Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development.展开更多
基金supported by the National Natural Science Foundation of China(No.81860268,and No.82201000)Ningxia Natural Science Foundation(No.2021AAC02025)+2 种基金Ningxia science and technology innovation leading talent training project(No.2020GKLRLX06 and No.2020GKLRLX11)Ningxia Medical University research project(No.XTJKF240315)Ningxia Key Research and Development Project(No.2023BEG03021 and No.2021BEB04034).
文摘To evaluate the therapeutic effect of a modified Devine procedure with a subcutaneous sliding fixation method for the treatment of congenital concealed penis,we retrospectively selected 45 patients with congenital concealed penises who were admitted to General Hospital of Ningxia Medical University(Yinchuan,China)between September 2020 and November 2023.In all cases,the penis was observed to be short,and retracting the skin at the base revealed a normal penile body,which immediately returned to its original position upon release.All patients underwent the modified Devine procedure with subcutaneous sliding fixation and completed a 12-week postoperative follow-up.A statistically significant increase in penile length was observed postoperatively,with the median length increasing from 4.0(interquartile range[IQR]:3.5–4.8;95%confidence interval[CI]:3.9–4.4)cm to 8.0(IQR:7.8–8.0;95%CI:7.7–7.9)cm,with P<0.001.The parents were satisfied with the outcomes,including increased penile length,improved hygiene,and enhanced esthetics.Except for mild foreskin edema in all cases,no complications(such as infections,skin necrosis,or penile retraction)were observed.The edema was resolved within 4 weeks after the operation.This study demonstrates that the modified Devine procedure utilizing the subcutaneous sliding fixation method yields excellent outcomes with minimal postoperative complications,reduced penile retraction,and high satisfaction rates among patients and their families.
基金supported by grants from the Shandong Provincial Natural Science Foundation(No.ZR2021MH033)the Linyi People’s Hospital,and the Key R&D Plan of Linyi City(No.2023xy0029).
文摘Objective Laparoscopic surgery has become a routine general surgery with many advantages,such as alleviating abdominal pain.However,postoperative pain caused by abdominal drainage tubes has attracted little attention from medical staff.The aim of this study was to explore the influence of a new abdominal drainage tube fixation method for 3-port laparoscopic cholecystectomy(LC)on patients’postoperative quality of life.Methods Patients who underwent 3-port LC with abdominal drainage tubes in the Department of Hepatobiliary Surgery of Linyi People’s Hospital from March 1,2023 to October 31,2023 due to gallstones with chronic cholecystitis were selected for this study.The patients were randomly divided into an experimental group and a control group.In the experimental group,the new abdominal drainage tube fixation method was used,while in the control group,the traditional method was used.Afterward,the quality of life of patient in terms of pain,activity,recovery time,and mental health status was evaluated.The exudate around the patient’s drainage tube was collected for bacterial culture and analysis.Results A total of 139 patients were randomly divided into an experimental group(70 patients)and a control group(69 patients).The patients’baseline characteristics were not significantly different.The patients in the experimental group had better outcomes in quality of life,with higher pain scores(24.03±2.37 vs.15.48±2.29,p<0.001)and activity scores(20.57±1.78 vs.14.13±1.43,p<0.001),and a shorter postoperative recovery time(2.36±0.68 d vs.2.96±1.34 d,p<0.001).The same results were shown in linear regression analysis scores of the 2 groups.The positive rate of bacterial culture in the exudate around the patient’s drainage tube in the experimental group was significantly lower than that in the control group(12.9%vs.43.5%,p<0.001);and furthermore,the positive rate of conditional pathogenic bacteria was even lower(7.1%vs.33.3%,p<0.001)in the experimental group than in the control group.Conclusion This new abdominal drainage tube fixation method can effectively promote patient rehabilitation and improve the quality of life for patient following 3-port LC with abdominal drainage tubes.
文摘Carbon dioxide fixation technique was developed as an alternative dechlorination method of chlorobenzenes. Electrolysis of chlorobenzene was carried out in a one-compartment cell fitted with an aluminium anode and a platinum cathode. Electrolysis in N, N-dimethylformamide (DMF) solution containing 0.1 M of tetrapropylammonium bromide (TPAB) at 0 ℃, 100 ml/min of CO2 flow rate and 120 mA/cm^2 of current density was found to be the optimum conditions of this electrocarboxylation, which gave 72% yield of benzoic acid from chlorobenzene. These conditions were then applied to 1,2-dichlorobenzene and 1,3-dichlorobenzene in order to convert them to their corrcsponding benzoic acids.
文摘Objective To measure the tensile strength of the normal medial patellofemoral ligament(MPFL),and evaluate the biomechanics of different fixation methods of the hamstring tendon graft on the patella.Methods Eight fresh cadaver knees were prepared by isolating the patella,leaving only the MPFL as its attachment to the medial condyle of femur.The MPFL was reconstructed by three different methods:four-suture fixation,anchors-single suture fixation,and anchors-double suture fixation.The tensile strength and the elongation of the normal MPFL and the tendon grafts were measured.Results The tensile strength of the four-suture fixation group(234.86±49.02 N)was stronger than that of the normal MPFL(146.91±25.30 N,P=0.0014)and the anchors-single suture group(159.17±49.07N,P=0.0077),while weaker than that of the anchors-double suture group(314.74±78.46 N,P=0.0052)Conclusions With regard to the tensile strength,the four-suture fixation method is reliable for clinical use.Compared with the anchor-suture method,the four-suture fixation method which has no specific implants is more economical,convenient and efficient.
基金Funded by National Scholastic Athletics Foundotion(NSAF)(No.U1330113)National Natural Science Foundation of China(No.81271953)
文摘Wafer curvature method has been applied to determine the internal stress in the films using Stoney's equation.During the film deposition,the wafer fixation on the sample holder will restrict the deformation of the rectangle-shaped wafer,which may result in the stress datum difference along length and width direction.In this paper,the effect of wafer size and the wafer fixation on the TiN film internal stress measured by wafer curvature method was discussed.The rectangle-shaped wafers with different length/width ratios(L/W=1:1,2:1,3:1 and 4:1) were fixed as a cantilever beam.After the TiN films deposition,the profiles of the film/wafer were measured using a stylus profilometer and then the internal stress was calculated using the Stoney equation in the film.The results showed that the fixed end of the wafers limited to some degree the curvature of the wafers along the width direction.For film internal stress measured by wafer curvature method,the wafer profile should be scanned along the length direction and the scan distance should be greater than or equal to half of wafer length.When the length/width ratio of the wafer reached 3:1,the wafer curvature and the calculated stress were basically the same at different positions along the length direction.For film internal stress measured by wafer curvature method,it was recommended that the length/width ratio of wafer should be considered to be greater than or equal to 3:1,and the deformed profile was scanned along the length direction.
文摘Comminuted fractures of the humerus are generally treated with the intramedullary rod fixed by screws or locking plate system,and clinical results are satisfactory.We also know very well that the success of this agriculture depends on the stability and adaptability and integration of the bone tissue of the humerus with this nail in the long term,with less and optimal distribution of stress in the surrounding bone.For this reason,we began to think and look for rational solutions to reduce and minimize this stress which has become an important issue in this area.In this regard,we have proposed a new model of hollow nail made of titanium proposed by some scientific specialists in this field of biomechanics,and we inserted from the proximal humeral head,and to ensure the stability of the nail inside the bone and prevent slippage,we attached small screws.To know the extent of the realization of these nails under the influence of the forces applied to them,finite elements in three dimensions as well as the program ANSYS Workbench 16.2 were used.Two intramedullary rods were instrumented in the finite element model of a medial humeral fracture.Axial,shear,and rotational loads were applied to the models under normal and osteoporotic bone conditions.The whole simulation was repeated 5 times for each fixator.To evaluate the biomechanical characteristics,the distribution of von Mises stresses and strains,total displacement in the nail,cortical and cancellous bone were compared.The numerical results showed that the intramedullary rod system with 4 screws and 6 screws played a very important role in the absorption and thus minimization of stresses.On the other hand,the nailing system fixed with screws was too great a role in reducing the stress compared to intact model.In general,the new model nailing system secured with screws gave a lower level of von Mises stress and strain at the cortical and cancellous bone of the humerus compared to the intact model.The results provided a theoretical basis for the selection of an appropriate surgical model.
文摘Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development.