A numerical study on fire endurance of wood beams exposed to three-side fire 被引量:6
1
作者 Jin ZHANG 1, Qing-feng XU2, Yi-xiang XU3, Bin WANG1, Jing-xiang SHANG1 (1Key Laboratory of Concrete and Prestressed Concrete Structures of the Ministry of Education, Southeast University, Nanjing 210096, China) (2Shanghai Key Laboratory of New Technology Research on Engineering Structure, Shanghai Research Institute of Building Sciences, Shanghai 200032, China) (3Department of Civil Engineering, Strathclyde University, Glasgow G12 8QQ, UK) 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2012年第7期491-505,共15页
To investigate the fire endurance of wood beams exposed to three-side fire, we conducted bearing capacity tests of two wood beams and experiments of five wood beams exposed to three-side fire. The finite element softw... To investigate the fire endurance of wood beams exposed to three-side fire, we conducted bearing capacity tests of two wood beams and experiments of five wood beams exposed to three-side fire. The finite element software ANSYS was also used to predict the fire endurance of those beams with the indirect order coupling method. It was found that the fire endurance decreases as the load level increases, and the reduction ratio tends to decrease. In the case of a certain load level, the fire endurance is improved if the section size is increased or covered by the fire protection coating. The central deformation increases as the fire duration increases, and the ratio of increase tends to rise. On another note, an increase in the density of wood leads to a rise in the fire endurance of a given beam. From the finite element method (FEM) calculation results, the fire endurance decreases as the load level increases, and the reduction ratio tends to decrease. When the load level is greater than 0.5, the fire endurance is significantly reduced, and it does not change significantly when the load level changes. Lastly, for a load level magnitude below 0.5, the fire endurance and load level are proportional to one another. 展开更多
关键词 Three-side fire fire endurance load level fire prevention measures Finite element analysis Density of wood
原文传递
Wildland fires and moist deciduous forests of Chhattisgarh, India: divergent component assessment 被引量:4
2
作者 B.H.Kittur S.L.Swamy +1 位作者 S.S.Bargali Manoj Kumar Jhariya 《Journal of Forestry Research》 SCIE CAS CSCD 2014年第4期857-866,共10页
We studied moist deciduous forests of Chhattisgarh, India (1) to assess the effect of four levels of historic wildland fire frequency (high, medium, low, and no-fire) on regeneration of seedlings in fire affected ... We studied moist deciduous forests of Chhattisgarh, India (1) to assess the effect of four levels of historic wildland fire frequency (high, medium, low, and no-fire) on regeneration of seedlings in fire affected areas during pre and post-fire seasons, (2) to evaluate vegetation struc- ture and diversity by layer in the four fire frequency zones, (3) to evalu- ate the impact of fire frequency on the structure of economically impor- tant tree species of the region, and (4) to quantify fuel loads by fire fre- quency level. We classified fire-affected areas into high, medium, low, and no-fire frequency classes based on government records. Tree species were unevenly distributed across fire frequency categories. Shrub density was maximum in zones of high fire frequency and minimum in low- frequency and no-fire zones. Lower tree density after fires indicated that regeneration of seedlings was reduced by fire. The population structure in the high-frequency zone was comprised of seedlings of size class (A) and saplings of size class (B), represented by Diospyros melanoxylon, Dalbergia sissoo, Shorea robusta and Tectona grandis. Younger and older trees were more abundant for Tectona grandis and Dalbargia sis- soo after fire, whereas intermediate-aged trees were more abundant pre- fire, indicating that the latter age-class was thinned by the catastrophic effect of fire. The major contributing components of fuel load included duff litter and small woody branches and twigs on the forest floor. Total fuel load on the forest floor ranged from 2.2 to 3.38 Mg/ha. The netchange in fuel load was positive in high- and medium-frequency fire zones and negative under low- and no-fire zones. Repeated fires, how- ever, slowly reduced stand stability. An ecological approach is needed for fire management to restore the no-fire spatial and temporal structure of moist deciduous forests, their species composition and fuel loads. The management approach should incorporate participatory forest manage- ment. Use of controlled fire, fire lines and mapping of fire prone areas are fundamental principles of fire hazard reduction in these areas. 展开更多
关键词 forest fire DIVERSITY fuel load vegetation structure
在线阅读 下载PDF
Behavior of steel-concrete composite slabs subjected to standard fire 被引量:2
3
作者 毛小勇 张耀春 韩林海 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2002年第2期155-160,共6页
Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in... Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in good agreement with those of tests. Fire resistance of the two kinds of composite slabs is calculated by using a numeric method. The results show that: due to heat absorbing of concrete, the performance of composite slabs under fire is better than that of unprotected steel structure, and fire resistance of composite slabs mentioned in this paper is at least 30 min subjected to standard fire. Parameters related to the fire resistance are discussed. It was found that with increasing of concrete strength and thickness of slab, fire resistance increases, and with increasing of steel strength and steel ratio, fire resistance decreases. Also thickness of fire proof is calculated by a numeric method. The results obtained in this paper may be referenced for practical engineering. 展开更多
关键词 Composite SLAB temperature FIELDS VALID load under fire failure CRITERIA fire resistance fire PROOF finite element numeric method
在线阅读 下载PDF
嵌套式受限空间火灾危险性分析与优化策略研究 被引量:2
4
作者 李华 阚双艳 益朋 《中国安全生产科学技术》 北大核心 2025年第10期156-165,共10页
为深入探究嵌套式受限空间的消防安全性能化设计优化策略,以调研统计密室逃脱类场所火灾荷载密度数据为基础,并通过建立嵌套式密室场所典型火灾模型,提出房门一键开启决策时间模型,分析房门一键开启时间阈值,进而对比分析不同火灾场景... 为深入探究嵌套式受限空间的消防安全性能化设计优化策略,以调研统计密室逃脱类场所火灾荷载密度数据为基础,并通过建立嵌套式密室场所典型火灾模型,提出房门一键开启决策时间模型,分析房门一键开启时间阈值,进而对比分析不同火灾场景下温度、CO体积分数和能见度变化规律。研究结果表明:中央火源位置房门一键开启的决策时间为7.3 s。通过对比纵向与横向蔓延路径,发现横向蔓延可在100 s时封锁疏散通道,可用疏散时间被显著缩短。喷淋设施改造后,温度峰值下降超过270℃,CO体积分数峰值下降超过0.1%,出口位置温度和CO体积分数达到临界值的时间被显著延缓。在温度、CO体积分数和能见度等指标分析基础上,提出高灵敏度感烟探测器与一键开启房门联动装置、喷淋与机械排烟协同系统的优化方案,可用疏散时间增幅达到54%。研究结果可为小尺度嵌套式受限空间的消防措施优化设计提供理论支撑。 展开更多
关键词 密室逃脱类场所 火灾模拟 火灾荷载 烟气蔓延 可用疏散时间
在线阅读 下载PDF
Dynamic Performance of On-off Operation for a Small Scale Direct Fired Absorption Chiller
5
作者 Wang Lei(王磊) +1 位作者 Lu Zhen(陆震) 《Journal of Donghua University(English Edition)》 EI CAS 2001年第1期46-50,共5页
A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship betwe... A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio. 展开更多
关键词 DIRECT fired ABSORPTION chiller part load DYNAMIC performance.
在线阅读 下载PDF
Estimation of gases emitted by forest fires based on remote sensing data
6
作者 Qiang Wang Futao Guo +2 位作者 Haiqing Hu Sen Jin Zhangwen Su 《Journal of Forestry Research》 SCIE CAS CSCD 2016年第2期369-378,共10页
Forest fire, an important agent for change in many forest ecosystems, plays an important role in atmo- spheric chemical cycles and the carbon cycle. The primary emissions from forest fire, CO2, CO, CH4, long-chained h... Forest fire, an important agent for change in many forest ecosystems, plays an important role in atmo- spheric chemical cycles and the carbon cycle. The primary emissions from forest fire, CO2, CO, CH4, long-chained hydrocarbons and volatile organic oxides, however, have not been well quantified. Quantifying the carbonaceous gas emissions of forest fires is a critical part to better under- stand the significance of forest fire in calculating carbon balance and forecasting climate change. This study uses images from Enhanced Thematic Mapper Plus (ETM+) on the Earth-observing satellite LANDSAT-7 for the year 2005 to estimate the total gases emitted by the 2006 Kanduhe forest fire in the Daxing'an Mountains. Our results suggest that the fire emitted approximately 149,187.66 t CO2, 21,187.70 t CO, 1925.41 t CxHy, 470.76 t NO and 658.77 t SO2. In addition, the gases emitted from larch forests were significantly higher than from both broadleaf-needle leaf mixed forests and broadleaf mixed forests. 展开更多
关键词 Forest fire Gases estimation Daxing'anMountains China Fuel load estimation Fuel loadconsumption Greenhouse gases CARBON
在线阅读 下载PDF
某铁路特大桥混凝土桥墩火损检测与评估 被引量:3
7
作者 张腾 《世界桥梁》 北大核心 2025年第3期117-123,共7页
某铁路特大桥一圆端形混凝土桥墩在施工期间发生火灾,桥墩过火时间约为10 min。为了解火灾对桥墩力学性能、承载能力的影响,指导后续维修加固,对桥墩外观、混凝土抗压强度、碳化深度、钢筋保护层厚度进行了专项检测;采用X-射线衍射(XRD... 某铁路特大桥一圆端形混凝土桥墩在施工期间发生火灾,桥墩过火时间约为10 min。为了解火灾对桥墩力学性能、承载能力的影响,指导后续维修加固,对桥墩外观、混凝土抗压强度、碳化深度、钢筋保护层厚度进行了专项检测;采用X-射线衍射(XRD)技术、热重-差示扫描热(TG-DSC)同步热分析以及扫描电子显微镜(SEM)分析推测火场最高温度;根据检测及热分析结果对墩身混凝土材料力学性能与剩余承载力进行分析。结果表明:墩身过火区域有混凝土剥落现象,混凝土抗压强度仍满足规范限值要求,且碳化深度较小,钢筋保护层厚度满足要求;受火时火场最高温度不超过800℃;火灾对桥墩核心混凝土材料力学性能影响很小,过火后桥墩剩余承载力满足设计要求。根据检测与评估结果,提出凿除受损区域局部混凝土后增设钢丝网片结合喷射混凝土或水泥砂浆将桥墩修复至设计截面尺寸的处治措施。 展开更多
关键词 铁路桥 混凝土桥墩 火灾 检测 温度场 承载能力 评估 处治
在线阅读 下载PDF
悬索桥索梁销接节点抗火性能研究
8
作者 李雪红 华晓烨 +2 位作者 杨国明 李亮 吴豪放 《桥梁建设》 北大核心 2025年第2期100-107,共8页
为了解悬索桥索梁销接节点在火灾下的响应特性和破坏形态,对该类节点开展了持载火灾试验和有限元研究。以南京新生圩长江大桥为背景,设计、制作索梁销接节点模型,采用拉压试验机张拉吊索至成桥索力后,采用电阻炉模拟火灾升温,分析持载... 为了解悬索桥索梁销接节点在火灾下的响应特性和破坏形态,对该类节点开展了持载火灾试验和有限元研究。以南京新生圩长江大桥为背景,设计、制作索梁销接节点模型,采用拉压试验机张拉吊索至成桥索力后,采用电阻炉模拟火灾升温,分析持载过程中节点应力、应变、温度、破坏形态等,并采用有限元法研究其应力及温度分布规律。结果表明:持载火灾试验中,节点模型在103 min时发生塑性变形,临界温度为864℃;134 min时叉耳发生颈缩拉断破坏,表面温度为1015℃。有限元模拟中,节点破坏时,叉耳的最大应力位于销孔两侧,吊耳受应力重分布影响,最大应力由销孔两侧逐渐转移到腹板底部,销轴两端应力较小、中间应力较大。对比有限元与试验结果,碳氢(HC)升温曲线和ISO834标准升温曲线作用下节点响应及抗火性能的变化规律基本一致,HC升温曲线作用下的节点破坏时间约30 min。 展开更多
关键词 悬索桥 索梁销接节点 抗火性能 破坏形态 耐火极限 持载火灾试验 有限元法
在线阅读 下载PDF
基于动态日碳排放配额模型的抽蓄辅助燃煤机组深度调峰低碳经济调度
9
作者 林俐 唐传伟 +3 位作者 丁文敏 徐宁 周龙文 赵冬梅 《华北电力大学学报(自然科学版)》 北大核心 2025年第5期1-10,I0001-I0003,共13页
为解决高比例风电系统的调峰难题,燃煤机组需进行灵活性改造,并频繁深度调峰,这将导致系统低碳经济运行水平下降。据此,梳理燃煤机组灵活性改造方法,分析经灵活性改造后的燃煤机组调峰全过程碳排放特性,得到基于调峰阶段划分的燃煤机组... 为解决高比例风电系统的调峰难题,燃煤机组需进行灵活性改造,并频繁深度调峰,这将导致系统低碳经济运行水平下降。据此,梳理燃煤机组灵活性改造方法,分析经灵活性改造后的燃煤机组调峰全过程碳排放特性,得到基于调峰阶段划分的燃煤机组碳排放强度计算模型;计及风电电量与净负荷峰谷差对系统碳排放的影响,建立动态的日碳排放额度分配模型;发挥抽蓄机组的减排潜力,提出一种基于动态日碳排放配额的抽蓄辅助燃煤机组深度调峰低碳经济调度策略,进而建立以系统总成本最小为目标的低碳经济调度模型。最后,基于改进的IEEE39节点算例进行仿真分析,验证了所提模型的可行性,且结果表明所提策略能在满足全年碳排放限额的基础上,保证系统经济性,并有效提高抽蓄的利用率和风电消纳水平。 展开更多
关键词 碳排放配额 燃煤机组 深度调峰 碳排放特性 抽水蓄能 低碳经济调度
在线阅读 下载PDF
深度调峰工况下燃煤锅炉煤氨混燃兼容性分析 被引量:3
10
作者 张皓玮 陈亮 王春波 《中国电机工程学报》 北大核心 2025年第9期3554-3562,I0023,共10页
掺氨燃烧是燃煤机组降低碳排放的有效手段。新能源大比例上网背景下,燃煤机组深度调峰成为新常态,低负荷下燃煤锅炉掺氨燃烧的兼容性有待探究。该文建立某600 MW超临界燃煤锅炉低负荷(50%~30%额定负荷)运行时掺氨燃烧的热力计算模型,探... 掺氨燃烧是燃煤机组降低碳排放的有效手段。新能源大比例上网背景下,燃煤机组深度调峰成为新常态,低负荷下燃煤锅炉掺氨燃烧的兼容性有待探究。该文建立某600 MW超临界燃煤锅炉低负荷(50%~30%额定负荷)运行时掺氨燃烧的热力计算模型,探究氨掺烧对低负荷下炉膛及对流受热面传热的影响。结果表明,低负荷工况下,掺烧0~50%氨对炉膛容积热负荷和截面热负荷影响不大,炉膛出口烟温上升6.5℃以内;通过调整尾部前后烟道的烟气份额,掺烧0~50%氨后主、再热蒸汽温度基本保持稳定;随掺氨比例增加,锅炉一、二次热风温度略有降低;与纯煤燃烧相比,50%掺氨比例下锅炉排烟温度增长5.8~7.6℃,由此导致锅炉效率下降约0.5%~0.7%。研究结果可为评估燃煤锅炉低负荷下煤氨混燃的可行性提供一定指导。 展开更多
关键词 燃煤锅炉 氨掺烧 低负荷 兼容性 热力计算
原文传递
面向低碳工业园区的预热燃烧锅炉技术与应用
11
作者 朱建国 吕清刚 +2 位作者 李百航 高鸣 韩会忠 《中国工程科学》 北大核心 2025年第5期65-77,共13页
构建低碳工业园区、促进能源结构转型、提高绿色生产水平是我国工业高质量发展的关键路径,低碳工业园区内源端可再生能源电力、荷端工业生产的蒸汽用量均呈现频繁的波动性,在低成本、大规模、长周期的储能技术全面工业化应用之前,预热... 构建低碳工业园区、促进能源结构转型、提高绿色生产水平是我国工业高质量发展的关键路径,低碳工业园区内源端可再生能源电力、荷端工业生产的蒸汽用量均呈现频繁的波动性,在低成本、大规模、长周期的储能技术全面工业化应用之前,预热燃烧锅炉具有承担源荷两端波动性调节的良好潜能。本文厘清了低碳工业园区用能趋势、预热燃烧锅炉的技术特征、低碳工业园区预热燃烧锅炉应用的适配性,梳理了预热燃烧锅炉的技术进展与发展方向,总结了我国预热燃烧锅炉的应用示范情况。开发的60t/h煤粉预热燃烧锅炉实现10%~100%超宽负荷范围的灵活调节,开发的90t/h煤粉预热燃烧锅炉实现压火46h无辅助燃料的快速启动,开发的240t/h循环流化床耦合煤粉预热燃烧锅炉实现化石能源和光伏电力的高效协同出力。后续,在生物质预热燃烧锅炉、预热燃烧锅炉氢氨掺烧或纯烧、锅炉启停与绿热供应协同、煤粉O_(2)/CO_(2)预热燃烧等方面实施技术攻关,以系统提升预热燃烧锅炉技术水平,全面支持零碳工业园区建设。 展开更多
关键词 锅炉 预热燃烧 超宽负荷 长时压火 日启停 低碳工业园区
在线阅读 下载PDF
往复荷载作用后钢管混凝土柱-组合梁节点耐火性能数值分析
12
作者 王文达 李生强 +1 位作者 毛文婧 郑龙 《建筑科学与工程学报》 北大核心 2025年第1期1-13,共13页
为研究钢管混凝土柱-组合梁节点在往复荷载作用后的耐火性能,利用有限元软件ABAQUS建立了该节点的有限元分析模型,并与已有试验结果进行对比验证。在此基础上,分析了往复荷载作用后塑性损伤和残余变形对组合梁节点火灾下的应力和变形的... 为研究钢管混凝土柱-组合梁节点在往复荷载作用后的耐火性能,利用有限元软件ABAQUS建立了该节点的有限元分析模型,并与已有试验结果进行对比验证。在此基础上,分析了往复荷载作用后塑性损伤和残余变形对组合梁节点火灾下的应力和变形的影响,以及不同损伤程度、荷载作用水平和防火保护层厚度对节点耐火极限和破坏模态的影响。结果表明:地震预损伤对节点的耐火极限有不利影响,且随损伤程度的增加,耐火极限下降明显;重度损伤下节点的耐火极限与无损伤节点相比降低了23.5%;重度损伤的节点在火灾作用下形成塑性铰,且产生较大的耗能损伤,轻度和中度损伤下未形成明显塑性铰,耐火极限分别仅下降1.0%和3.6%;对于以梁损伤作为预损伤模式的节点,梁荷载比和防火保护层厚度是影响有地震预损伤节点耐火极限的主要因素;随柱荷载比的增大,耐火极限呈降低趋势,但整体影响不大。 展开更多
关键词 钢管混凝土柱-组合梁节点 低周往复加载 损伤程度 耐火极限
在线阅读 下载PDF
木框架承重组合墙体足尺耐火试验研究
13
作者 杨成 吉鑫民 +3 位作者 宋谦益 刘宜丰 陈伟 胡瑞青 《土木工程学报》 北大核心 2025年第9期30-43,共14页
开展5片板材覆面的木框架承重组合墙体试验研究,其中对1片墙体进行常温轴压极限承载力试验;对4片墙体开展ISO834标准升温条件下的墙体耐火试验。墙体木框架所用木材为欧洲云杉和新西兰辐射松,覆面板材主要采用玄武岩纤维增强镁质水泥板... 开展5片板材覆面的木框架承重组合墙体试验研究,其中对1片墙体进行常温轴压极限承载力试验;对4片墙体开展ISO834标准升温条件下的墙体耐火试验。墙体木框架所用木材为欧洲云杉和新西兰辐射松,覆面板材主要采用玄武岩纤维增强镁质水泥板和复合发泡镁质水泥防火板。基于试验并结合有限元数值分析方法,研究木框架承重组合墙体常温轴向受力条件下的极限承载力、破坏模式;研究标准火灾环境下墙体的升温规律和耐火极限。常温下,墙体轴压极限承载力为1120kN,主要破坏模态为上梁木材在木龙骨连接处的局部横纹受压破坏;在有限元分析和简化公式计算的基础上,分析龙骨不同约束条件下的典型破坏模式,明确抗火设计计算时墙体火灾荷载比定义。火灾条件下,低密度层增加10mm,墙体耐火时间提高50min;荷载大小提高50%,墙体耐火时间减少61min,降低54%。墙体覆面板材的构造(如材料、层次、板厚)等直接影响其升温规律并与墙体的荷载水平一起影响墙体的耐火极限,该研究内容和结论可为相关研究和工程应用提供参考。 展开更多
关键词 木框架承重组合墙体 轴压极限承载力 火灾荷载比 ISO-834标准火灾曲线 耐火极限 防火板
原文传递
基于凋落物分解速率的森林凋落叶载量动态预测 被引量:1
14
作者 蔡志勇 孙龙 +2 位作者 胡海清 赵南 孙家宝 《北京林业大学学报》 北大核心 2025年第5期123-130,共8页
【目的】森林凋落叶作为森林易燃物的关键组成部分,直接影响森林火灾发生与蔓延风险。本文以大兴安岭白桦林为研究对象,从森林凋落叶产生与分解角度构建数学模型,预测未来森林凋落叶载量动态,为森林防火科学研究提供理论基础。【方法】... 【目的】森林凋落叶作为森林易燃物的关键组成部分,直接影响森林火灾发生与蔓延风险。本文以大兴安岭白桦林为研究对象,从森林凋落叶产生与分解角度构建数学模型,预测未来森林凋落叶载量动态,为森林防火科学研究提供理论基础。【方法】基于Olson单指数分解方程,将地表现存凋落叶视为历年凋落叶分解残留量的累积,构建凋落叶分解方程组。采用数列求和、换元法、逐步搜索法等数学方法化简方程,求解凋落叶分解速率系数和分解周转期。在此基础上建立凋落叶载量预测模型,并通过野外样地调查获取实测数据验证模型精度。【结果】成功构建基于凋落物分解速率的凋落叶载量预测模型,模型验证显示:未来2年凋落叶载量预测值与实测载量相对误差范围为0.05~0.26(平均误差0.14),表明模型具有较好的预测准确性。【结论】模型预测揭示了大兴安岭林区凋落叶载量随时间变化呈现周期性消长规律,分解速率快的林分变化周期短,凋落叶载量维持较稳定状态;分解速率慢的林分变化周期长,凋落叶载量保持较长时间持续变化。本研究建立的模型可有效预测凋落叶载量动态变化,对量化森林可燃物负荷、评估区域火险等级具有重要应用价值。 展开更多
关键词 凋落物分解 森林防火 森林可燃物 可燃物载量 载量模型
在线阅读 下载PDF
变压器火灾下变电站钢构架柱承载稳定性试验研究
15
作者 刘睿 张佳庆 +3 位作者 过羿 沈旭钊 殷振 洪清泉 《建筑结构》 北大核心 2025年第23期128-136,共9页
变压器火灾事故会对周边电力设施的安全运行产生较大威胁。为研究变压器周边人字钢构架柱在火灾时的承载稳定性,利用大型结构抗火试验平台对某实际工程中钢构架柱模型开展真实火灾试验,测试试件受火区域表面的温度场分布、柱顶竖向位移... 变压器火灾事故会对周边电力设施的安全运行产生较大威胁。为研究变压器周边人字钢构架柱在火灾时的承载稳定性,利用大型结构抗火试验平台对某实际工程中钢构架柱模型开展真实火灾试验,测试试件受火区域表面的温度场分布、柱顶竖向位移和耐火极限,总结了人字钢构架柱在火灾高温下的破坏模式,并验证了施加防火保护对提高构件耐火性能的有效性。研究结果表明:钢构架柱常温下发生结构的平面外整体失稳,而火灾下为受火区域的整体失稳破坏;钢构架柱的耐火极限受荷载比的影响较大且较为敏感;当荷载比为0.1时,可以实现无防护措施的钢构架柱满足在2h的有效救援时间内承载力稳定而不发生破坏;施加防火保护可以显著提升钢构架柱在火灾时的稳定承载能力。 展开更多
关键词 变压器火灾 钢构架柱:火灾试验 荷载比 承载稳定性 耐火性能
在线阅读 下载PDF
锅炉深负荷调峰下空气预热器适应性方案技术研究 被引量:1
16
作者 罗洪涛 郭大山 高嵩 《锅炉制造》 2025年第2期22-24,共3页
根据国家政策要求,燃煤锅炉的深负荷调峰改造势在必行。锅炉的深负荷调峰将对空气预热器产生不利影响,本文将对回转式空气预热器在锅炉深负荷调峰下的适应性改造方案进行研究和分析。
关键词 燃煤锅炉 深负荷调峰 空气预热器
在线阅读 下载PDF
办公楼数字化火灾荷载调查:数据收集和统计分析 被引量:1
17
作者 丁一飞 吕昕 +2 位作者 张伟杰 张予馨 黄鑫炎 《消防科学与技术》 北大核心 2025年第2期152-155,162,共5页
火灾荷载调查数据可以为消防设计规范的制定和建筑特殊消防设计提供依据。为扩展现有的火灾荷载数据库,本研究采用基于机器视觉的数字化调查方法对国内27间办公室(11间大学校园办公室和16间商业办公室,总面积达3 130 m^(2))展开火灾荷... 火灾荷载调查数据可以为消防设计规范的制定和建筑特殊消防设计提供依据。为扩展现有的火灾荷载数据库,本研究采用基于机器视觉的数字化调查方法对国内27间办公室(11间大学校园办公室和16间商业办公室,总面积达3 130 m^(2))展开火灾荷载调查。所调查办公室的平均火灾荷载密度为(1 224±1 142) MJ/m^(2),其中大学校园办公室为(382±297) MJ/m^(2),商业办公室为(1 804±1 391) MJ/M^(2)。与历史数据和规范设计值相比,商业办公室的火灾荷载密度明显偏高。此外,可燃物成分分析发现,塑料制品在建筑内部可燃物中的占比有明显上升趋势。基于此,本研究建议在消防安全设计时考虑区分校园办公室和商业办公室,并注意燃料成分的变化趋势。 展开更多
关键词 火灾荷载 数字化调查 现代办公楼 特殊消防设计
在线阅读 下载PDF
循环流化床锅炉全负荷调峰特性研究 被引量:6
18
作者 乔磊磊 王孝全 +7 位作者 聂浩 柳成亮 魏绍青 郝海俊 李绍军 冯浩 吕俊复 柯希玮 《中国电机工程学报》 北大核心 2025年第1期184-193,I0015,共11页
基于循环流化床(circulating fluidized bed,CFB)燃烧技术的燃煤发电机组可实现长周期压火热备运行与快速启停,即具备全负荷调峰能力。在某300 MW亚临界CFB锅炉上的试验结果显示,机组功率能够以10.4%Pe/min的速率快速降至1 MW,后在1%极... 基于循环流化床(circulating fluidized bed,CFB)燃烧技术的燃煤发电机组可实现长周期压火热备运行与快速启停,即具备全负荷调峰能力。在某300 MW亚临界CFB锅炉上的试验结果显示,机组功率能够以10.4%Pe/min的速率快速降至1 MW,后在1%极低负荷率下维持长时间稳定运行,总压火时长超过110 min,压火结束后又能以3.5%Pe/min的速率实现热态再启。压火期间,平均床温以2.2℃/min的速度从800℃降至553℃;主汽温度和主汽压力分别下降了165℃和1.7 MPa;各受热面横向温度偏差基本在10℃以内;汽轮机和发电机运行平稳,各项参数都在安全限值以内。扬火瞬时烟气CO浓度急剧上升超过1%,但无爆燃风险。调峰全过程尘硫氮污染物排放小时均值满足超低排放要求。该研究为深入挖掘煤电机组灵活性提供了一个更具竞争力的方向,对高比例消纳风光等可再生能源、保障新型电力系统可靠稳定运行具有重要意义。 展开更多
关键词 灵活煤电 循环流化床(CFB) 全负荷调峰 快速启停 压火热备
原文传递
火灾下波形钢腹板PC组合梁预应力衰变规律研究 被引量:1
19
作者 郑尚敏 吴志强 《桥梁建设》 北大核心 2025年第5期112-120,共9页
为给波形钢腹板PC组合梁的抗火设计提供依据,设计1片该类型组合梁,采用ANSYS软件建立火灾下该组合梁热-结构分析的有限元模型,研究其抗火性能,分析不同火灾模式、荷载比及预应力比对其预应力衰变的影响,并提出火灾下该类型组合梁预应力... 为给波形钢腹板PC组合梁的抗火设计提供依据,设计1片该类型组合梁,采用ANSYS软件建立火灾下该组合梁热-结构分析的有限元模型,研究其抗火性能,分析不同火灾模式、荷载比及预应力比对其预应力衰变的影响,并提出火灾下该类型组合梁预应力衰变系数计算公式。结果表明:火灾下,波形钢腹板PC组合梁沿截面高度方向的温度场呈显著的梯度分布,温度梯度最大可达3 426℃/m;组合梁跨中挠度曲线可分为缓慢增长、显著增长及急速增长3个阶段,且各阶段挠度增长速率呈倍速变化,缓慢增长阶段的增长速率为0.6 mm/min,急速增长阶段的增长速率为6.7 mm/min,约为缓慢增长阶段的11倍;组合梁的预应力随着延火时间的增长不断衰变,衰变速率从37.4 MPa/min减小至4.2 MPa/min;不同火灾模式下组合梁预应力衰变趋势一致;随着荷载比及预应力比的增大,预应力衰变前、中期衰变速率呈增大趋势,预应力衰变后期衰变速率基本一致;提出的火灾下组合梁预应力衰变系数计算公式能较好地预测组合梁预应力衰变。 展开更多
关键词 组合梁 波形钢腹板 抗火性能 预应力衰变 火灾模式 预应力比 荷载比 有限元法
在线阅读 下载PDF
燃煤机组变负荷运行下的脱硫废水零排放流程模拟分析 被引量:1
20
作者 杨文毅 由长福 王海名 《化工学报》 北大核心 2025年第7期3468-3476,共9页
通过建立300 MW燃煤机组厂级全流程模型,对比分析了40%~100%额定工况(THA)下3种不同热源驱动的脱硫废水零排放技术的性能,揭示了电厂脱硫废水在热法浓缩过程中的水-能耦合平衡关系。结果表明,当机组负荷降低,负荷偏离额定值越多,热、电... 通过建立300 MW燃煤机组厂级全流程模型,对比分析了40%~100%额定工况(THA)下3种不同热源驱动的脱硫废水零排放技术的性能,揭示了电厂脱硫废水在热法浓缩过程中的水-能耦合平衡关系。结果表明,当机组负荷降低,负荷偏离额定值越多,热、电负荷差距越大,在40%THA下的热负荷率为45.76%。在3种脱硫废水零排放技术中,两种三效蒸发干燥方式的单位耗热量最低,为0.017 kJ/t,不到高温烟气旁路干燥方式的1/2,节能效果良好,其中三效烟气取热干燥方式利用的是烟气废热,不损失发电量,其锅炉效率和发电效率最高,在100%THA下分别为85.59%和32.25%,在降低能源成本和减少环境污染方面具有更大优势。相关研究可以为合理选择全工况脱硫废水处理技术提供依据。 展开更多
关键词 燃煤电厂 变负荷 脱硫废水 零排放 三效蒸发
在线阅读 下载PDF