期刊文献+
共找到6,223篇文章
< 1 2 250 >
每页显示 20 50 100
EXCIMER LASER ABLATING OF LIQUID CRYSTAL POLYMER
1
作者 梅胜敏 左敦稳 余大民 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1998年第2期72-77,共6页
Ablation experiments of A950 Liquid Crystal Polymer (LCP), as a kind of typical matrix of fibre reinforced polymer composites, are carried out in this paper. Data on the ablation of A950 LCP by excimer laser at 24... Ablation experiments of A950 Liquid Crystal Polymer (LCP), as a kind of typical matrix of fibre reinforced polymer composites, are carried out in this paper. Data on the ablation of A950 LCP by excimer laser at 248 nm are presented. The experimental results show that the ablation depth is a linear function of the number of pulse at constant laser fluence, The ablation rate varies with the logorithm of the fluence in a linear manner at different fluences. A satisfactory linear relationship is found between ablation energy and incident fluence. Perhaps due to the plume absorption and thermal effect, the ablation rate varies complicatedly with pulse repetition frequency. 展开更多
关键词 laser processing ablation POLYMER excimer laser
在线阅读 下载PDF
Smaller Ge Quantum Dots Obtained by ArF Excimer Laser Annealing
2
作者 曾玉刚 韩根全 余金中 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第4期641-644,共4页
Ge self-assembled quantum dots (SAQDs) are grown with a self-assembled UHV/CVD epitaxy system. Then, the as-grown Ge quantum dots are annealed by ArF excimer laser. In the ultra-shot laser pulse duration, -20ns, bul... Ge self-assembled quantum dots (SAQDs) are grown with a self-assembled UHV/CVD epitaxy system. Then, the as-grown Ge quantum dots are annealed by ArF excimer laser. In the ultra-shot laser pulse duration, -20ns, bulk diffusion is forbidden,and only surface diffusion occurs, resulting in a laser induced quantum dot (LIQD). The diameter of the LIQD is 20-25nm which is much smaller than the as-grown dot and the LIQD has a higher density of about 6 ×10^10cm^-2. The surface morphology evolution is investigated by AFM. 展开更多
关键词 Ge quantum dot ArF excimer laser annealing LIQD AFM
在线阅读 下载PDF
Successful opening in-stent chronic total occlusion lesion of coronary artery by excimer laser coronary angioplasty 被引量:3
3
作者 Jing BAI Hai-Xia WANG +7 位作者 Jiang-Tao WANG Jing ZHAO Liang PENG Xue-Dong YANG Zhe TANG Shaheena Nazneen Gao-Kun WANG Yu WANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2019年第6期502-506,共5页
In percutaneous coronary intervention (PCI), chronic total occlusion (CTO) coronary artery disease still remains difficult to treat. One of the reasons for the failure is the hard of the CTO lesions that balloon is di... In percutaneous coronary intervention (PCI), chronic total occlusion (CTO) coronary artery disease still remains difficult to treat. One of the reasons for the failure is the hard of the CTO lesions that balloon is difficult to pass through or expand. Previous methods to deal with CTO lesions that cannot be passed by balloon, include selecting reinforced catheter (such as 5 in 6 guiding catheter, Guidzilla catheter, or Tornus microcatheter), guidewire extrusion or rotary grinding technology. In recent years, excimer laser coronary angioplasty (ELCA) has been gradually applied to CTO lesions. Using inert halide as the laser medium, ELCA emits a 308 nm high-intensity unidirectional light wave with absorption depth of only 50 μmL, resulting in less thermal effect and less damage to non-target lesions. In this paper, we will describe a successful PCI case of an in-stent CTO lesion using ELCA with long term coronary angiography follow-up. 展开更多
关键词 Chronic total occlusion Drug coating BALLOON excimer laser CORONARY ANGIOPLASTY PERCUTANEOUS CORONARY intervention
暂未订购
Percutaneous recanalization of total saphenous vein graft occlusion with excimer laser treatment 被引量:4
4
作者 Yuan HAN Quan-Min JING +2 位作者 Qian-Cheng WANG Yan-Bin SU Guo-Jun CHEN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第4期234-240,共7页
Patients presenting with recurrence of anginal symptoms after saphenous vein bypass surgery pose an increasingly frequent challenge.In general,approximately 40%to 50%of saphenous vein graft(SVG)will become diseased or... Patients presenting with recurrence of anginal symptoms after saphenous vein bypass surgery pose an increasingly frequent challenge.In general,approximately 40%to 50%of saphenous vein graft(SVG)will become diseased or occluded within the first ten years after surgery.[1]Because adverse clinical outcomes,such as high restenosis rates and distal embolization,have been reported,percutaneous coronary intervention(PCI)for SVG is not recommended as a first-line strategy.[2]Distal embolization occurs in 2%–17%of patients despite advances in therapy,including the utilization of embolic protection device(EPD),which may lead to increased mortality at both short follow-up and midterm follow-up.[3]However,these patients often associated with inappropriate anatomic characteristics of native vessel intervention including calcification,tortuosity,abundant plaque burden,and complex chronic total occlusion(CTO)lesions.Moreover,repeat coronary bypass surgery is an option but is technically more demanding and is associated with a higher mortality.Therefore,it can sometimes result in SVG stenosis being the only intervention option.This is why the recanalization of SVG lesions,especially totally occluded lesions,remains one of the most challenging procedures in interventional cardiology. 展开更多
关键词 excimer laser PERCUTANEOUS CORONARY intervention Saphenous VEIN GRAFT
暂未订购
Understanding the effects of excimer laser treatment on corrosion behavior of biodegradable Mg-1Ca alloy in simulated body fluid 被引量:2
5
作者 Yuxiang Liu Michele Curioni +1 位作者 Shiyun Dong Zhu Liu 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2022年第4期1004-1023,共20页
In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SB... In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SBF)solution using immersion tests and electrochemical impedance spectroscopy(EIS).A 5μm melted layer with a homogeneous microstructure and an MgO film on the surface were achieved by laser radiation.Corrosion observations(hydrogen evolution,morphology and corrosion products)and EIS results revealed an improvement of corrosion resistance after laser treatment for 48 h.It was found a two-layer structure developed after 2 h immersion on both the untreated and laser-treated alloys,but the sequence of forming the two layers was opposite and greatly influenced by the laser-treated layer.The time-evolution corrosion processes on the untreated and laser-treated alloys were discussed,providing a better understanding of corrosion behavior of biodegradable Mg alloys modified by excimer laser. 展开更多
关键词 MAGNESIUM Biodegradable implant excimer laser Simulated body fluid Corrosion EIS
在线阅读 下载PDF
Nickel-disilicide-assisted excimer laser crystallization of amorphous silicon 被引量:1
6
作者 廖燕平 邵喜斌 +5 位作者 郜峰利 骆文生 吴渊 付国柱 荆海 马凯 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第6期1310-1314,共5页
Polycrystalline silicon (poly-Si) thin film has been prepared by means of nickel-disilicide (NiSi2) assisted excimer laser crystallization (ELC). The process to prepare a sample includes two steps. One step cons... Polycrystalline silicon (poly-Si) thin film has been prepared by means of nickel-disilicide (NiSi2) assisted excimer laser crystallization (ELC). The process to prepare a sample includes two steps. One step consists of the formation of NiSi2 precipitates by heat-treating the dehydrogenated amorphous silicon (a-Si) coated with a thin layer of Ni. And the other step consists of the formation of poly-Si grains by means of ELC. According to the test results of scanning electron microscopy (SEM), another grain growth model named two-interface grain growth has been proposed to contrast with the conventional Ni-metal-induced lateral crystallization (Ni-MILC) model and the ELC model. That is, an additional grain growth interface other than that in conventional ELC is formed, which consists of NiSi2 precipitates and a-Si. The processes for grain growth according to various excimer laser energy densities delivered to the a-Si film have been discussed. It is discovered that grains with needle shape and most of a uniform orientation are formed which grow up with NiSi2 precipitates as seeds. The reason for the formation of such grains which are different from that of Ni-MILC without migration of Ni atoms is not clear. Our model and analysis point out a method to prepare grains with needle shape and mostly of a uniform orientation. If such grains are utilized to make thin-film transistor, its characteristics may be improved. 展开更多
关键词 polycrystalline silicon excimer laser crystallization Ni-disilicide Ni-metal-induced lateral crystallization two-interface grain growth
原文传递
Excimer laser coronary atherectomy for a severe calcified coronary ostium lesion:A case report 被引量:2
7
作者 Fang-Jie Hou Xiao-Teng Ma +1 位作者 Yu-Jie Zhou Jun Guan 《World Journal of Clinical Cases》 SCIE 2021年第34期10666-10670,共5页
BACKGROUND Percutaneous coronary intervention can be challenging for ostial coronary artery lesions due to calcium burden and elastic fiber content.Excimer laser coronary atherectomy(ELCA)is a less common treatment fo... BACKGROUND Percutaneous coronary intervention can be challenging for ostial coronary artery lesions due to calcium burden and elastic fiber content.Excimer laser coronary atherectomy(ELCA)is a less common treatment for severe calcified coronary ostium lesions.CASE SUMMARY An 81-year-old male presented to the Cardiology Department of Qingdao Municipal Hospital with a 1-year history of chest pain.Coronary angiography showed severe calcific stenosis(approximately 90%)in the right coronary artery ostium.The right coronary artery ostium was unable to be advanced using a 2.5 mm×12.0 mm balloon(NC Sprinter,Medtronic,United States)or dilated using a 2.0 mm×12.0 mm balloon(Sprinter,Medtronic,United States).The patient underwent successful ELCA and balloon dilation of the calcified coronary ostium lesion.CONCLUSION ELCA appears to be a safe and effective treatment for the management of severe calcified coronary ostium lesions. 展开更多
关键词 excimer laser coronary atherectomy Coronary ostium lesion Coronary calcified lesion Intravascular ultrasound Case report
暂未订购
Comparative study of functional optical zone:small incision lenticule extraction versus femtosecond laser assisted excimer laser keratomileusis 被引量:2
8
作者 Yao-Wen Song Meng-Fan Cui +3 位作者 Yi Feng Min Qu Yan Gao Rui He 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第2期238-244,共7页
AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential as... AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential associated factors for FOZ.METHODS:A total of 133 patients who received corneal refractive surgery in our hospital between November 2018 and July 2021 were retrospectively enrolled.There were 63 patients(123 eyes)in SMILE group and 70patients(139 eyes)in FS-LASIK group.The size of FOZ was measured using Pentacam 3-dementional anterior segment analyzer before and 3mo after surgery,so as to analyze postoperative achieved functional optical zone(AFOZ)and its contributing parameters.RESULTS:When planned functional optical zone(PFOZ)was 6.5 mm for both groups,AFOZ was 1.45±0.27 and 1.67±0.25 mm smaller than preoperative FOZ in SMILE group and FS-LASIK group 3mo after surgery.AFOZ in SMILE group was significantly larger than that in FS-LASIK group(P<0.001).Variation of FOZ was negatively correlated with preoperative spherical equivalent(SE)and positively correlated with variation of mean keratometry value(△Km),variation of spherical aberration(△SA),and variation of Q-value(△Q,all P<0.001)in both groups.Multiple variable linear regression equations were△FOZ=1.354-0.1×pre-SE+0.336×△Q+1.462×△SA in SMILE group and△FOZ=1.512+0.137×△Q+0.468×△SA in FS-LASIK group.CONCLUSION:AFOZ is significantly smaller than preoperative FOZ in both SMILE and FS-LASIK groups.With the same PFOZ,larger AFOZ is achieved in SMILE group than in FS-LASIK group. 展开更多
关键词 functional optical zone small incision lenticule extraction femtosecondlaser assisted excimer laser keratomileusis spherical equivalent spherical aberration
原文传递
Multiple excimer laser phototherapeutic keratectomies for Avellino corneal dystrophy:a case report 被引量:1
9
作者 Chihiro Koiwa Satoru Nakatani +3 位作者 Takenori Inomata Masahiro Yamaguchi Satoshi Iwamoto Akira Murakami 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第5期841-844,共4页
Dear Editor,I am Chihiro Koiwa,from the Department of Ophthalmology,Juntendo University Hospital.I am writing this letter to present a case of multiple excimer laser phototherapeutic keratectomies(PTKs)for Avellino co... Dear Editor,I am Chihiro Koiwa,from the Department of Ophthalmology,Juntendo University Hospital.I am writing this letter to present a case of multiple excimer laser phototherapeutic keratectomies(PTKs)for Avellino corneal dystrophy(ACD).Corneal dystrophy is a common type of hereditary,noninflammatory,and bilateral corneal disorder that involves various pathological,histological,and clinical manifestations[1].Advanced molecular gene sequencing has identified specific mutations that are associated with most dystrophies of this type.ACD,also known as granular corneal dystrophy typeⅡ[2],is autosomal dominant and associated with the R124H mutation of the transforming growth factor beta-induced(TGFBI)gene and characterized by deposits consistent with both discrete granular and lattice corneal opacities[3-4].An analysis of the TGFBI gene is essential to differentiate ACD because heterozygous R124H mutation carriers have minimal corneal abnormalities,whereas homozygotes have severe visual impairment,starting from early childhood,and early postoperative recurrence of corneal opacity. 展开更多
关键词 laser excimer STARTING
原文传递
Histopathological Study of Trabeculum after Excimer Laser Trabeculectomy ab Interno 被引量:3
10
作者 Shengsong Huang,Minbin Yu,Guangqiang Feng,Ping Zhang,Changyu QiuZhongshan Ophthalmic Center, Sun Yat-sen University of Medical Sciences, Guangzhou 510060 , China 《眼科学报(英文版)》 CAS 2001年第1期11-15,共5页
Purpose: To study the clinical manifestations and histopathologic changes of trabeculum after excimer laser trabeculectomy ab interno (ELT), and to investigate the mechanisms of ELT in reducing intraocular pressure.Me... Purpose: To study the clinical manifestations and histopathologic changes of trabeculum after excimer laser trabeculectomy ab interno (ELT), and to investigate the mechanisms of ELT in reducing intraocular pressure.Methods : ELT was performed on ten rabbit eves and postoperative responses were documented. Comeoscleral tissue samples were harvested consecutively each week until the 5th postoperative week and these samples were examined under light and electrical microscopy.Results: Mild stimulation signs were present postoperatix'ely in nine of ten eyes, but no serious complications were experienced. Obvious inflammation was observed in one rabbit eye as a result of iris damage during the surgical manipulations. Local kactures on the trabecular meshwork and openings into Schlemm' s canal were detected in all tissue samples under light microscope. Mitochondria were found to be turgescent and dilated like vacuoles and endoplasmic reticula were found to be dilated under electrical microscope in the early postoperative period. Later, all trabecular cells returned normal and no fihroblast cells were ever detected.Conclusions: Permanent openings through trabecular meshwork into the inner wall of Schlemm's canal can be created with ELT. The outflow resistance of aqueous humor can be reduced with these openings and intraocular pressure can be controlled thereafter. Eye Science 2001; 17:11 ~ 15. 展开更多
关键词 组织病理学 准分子激光疗法 ELT 高眼压 青光眼
暂未订购
Comparison of clinical outcomes of deep anterior lamellar keratoplasty and excimer laser assisted anterior lamellar keratoplasty in keratoconus
11
作者 Kübra Serbest Ceylanoglu Bahri Aydin Mehmet Cuneyt Ozmen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第4期582-586,共5页
AIM: To compare and evaluate the clinical outcomes of deep anterior lamellar keratoplasty(DALK) and excimer laser assisted anterior lamellar keratoplasty(ELLK) in eyes with keratoconus.METHODS: In this study, 57 eyes ... AIM: To compare and evaluate the clinical outcomes of deep anterior lamellar keratoplasty(DALK) and excimer laser assisted anterior lamellar keratoplasty(ELLK) in eyes with keratoconus.METHODS: In this study, 57 eyes of 56 patients operated between 2013 to 2017 were included. Thirty-one eyes underwent big-bubble DALK and twenty-six eyes underwent ELLK. Preoperative and at control visits complete ophthalmic examination was performed. RESULTS: The mean patient age at the time of DALK surgery was 27 y and mean follow-up period was 21±5.4 mo. The mean patient age at the time of ELLK surgery was 27 y and mean follow-up period was 40±18 mo. Mean best spectacle corrected visual acuity(BSCVA) at postoperative period was significantly higher for DALK group(0.66±0.11) versus ELLK group(0.4±0.2)(P<0.05). Descemet's membrane microperforation was occurred in 7 patients in DALK group versus in 1 patient in ELLK group. In 4 eyes, interface irregularity was developed in ELLK group. None of the patients in follow-up had graft rejection in both groups.CONCLUSION: In ELLK group, complication rate is lower, the surgical technique is simpler, faster and safer and also ELLK requires less experience with respect to DALK. Further, DALK can be performed unless satisfactory visual acuity is achieved after ELLK. 展开更多
关键词 excimer laser ASSISTED LAMELLAR KERATOPLASTY deep ANTERIOR LAMELLAR KERATOPLASTY big-bubble technique
原文传递
Effect of open ultraviolet germicidal irradiation lamps on functionality of excimer lasers used in cornea surgery
12
作者 Jaroslavas Belovickis Aliaksei Kurylenka Vadim Murashko 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第9期1474-1476,共3页
We report on the impact of direct ultraviolet germicidal irradiation(UVGI)on reflective optics,used in the excimer laser system Allegretto Eye-Q.The aim of our work was to confirm our hypothesis based on long-rate o... We report on the impact of direct ultraviolet germicidal irradiation(UVGI)on reflective optics,used in the excimer laser system Allegretto Eye-Q.The aim of our work was to confirm our hypothesis based on long-rate observations of obtained anomalies in post-operative results that are attributed to degradation of reflective optics upon ultraviolet radiation.The presence of direct UVGI coupled with humidity in the operating environment caused merging anomalies and unwanted post-operative correction values.Ultraviolet-A radiation caused a similar effect on the reflective cover of the mirrors. 展开更多
关键词 ultraviolet radiation excimer lasers post-operative anomalies laser-assisted in situ keratomileusis mirror degradation
原文传递
The Characteristics of the Surface Topography of Excimer Laser Processed Al_2O_3 Ceramic
13
作者 刘莹 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2004年第B10期11-14,共4页
Surface of Al 2O 3 ceramic was processed by an excimer laser and the characteristics of topography were examined based on the application of the microelectromechanical system(MEMS). It is indicated that the statisti... Surface of Al 2O 3 ceramic was processed by an excimer laser and the characteristics of topography were examined based on the application of the microelectromechanical system(MEMS). It is indicated that the statistic parameters of surface topography processed by the excimer laser have an obvious regularity. The arithmetic-mean value R a and the root-mean square value R q change with the changing of processing parameters in the same step and trend, and there is a quantitative relation between them.A simplified model is proposed for the excimer laser processing surface profile, whose results of the analysis and calculation agree basically with the experimental data. Furthermore,the surfaces processed by excimer laser are greatly flat. Skewness root-mean-square value Z· q changed little with the change of the technological parameters. The above characteristics depend on the processing principle of excimer laser, quite different from the cutting processing. 展开更多
关键词 excimer laser processing surface topography characteristics of topography parameters
在线阅读 下载PDF
Experimental Study on the Early Efficacy of Excimer Laser with Adjunctive Balloon Angioplasty in Dog's Femoral Artery
14
作者 曾和松 余枢 +5 位作者 谷怀民 汪道文 赵光兴 胡方斌 胡雪金 赵震声 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第2期87-90,共4页
The effect of domestically-manufactured excimer laser with adjunctive balloon angioplasty in achieving revascularization and reduction of residual stenosis was assessed. 20 femoral arteries with thrombosis and occlusi... The effect of domestically-manufactured excimer laser with adjunctive balloon angioplasty in achieving revascularization and reduction of residual stenosis was assessed. 20 femoral arteries with thrombosis and occlusion from 12 dogs were subject to angiography. At first excimer laser angioplasty was done followed by balloon angioplasty. The diameter and residual stenosis of revascularized vessel were measured. The result showed that 17 out of 20 vessels (85 %) were revascularized. The diameter of revascularized vessel by excimer laser were 1. 22±0.14 mm,while residual stenoses were 54 %±5%. After adjunctive balloon angioplasty the diameter and residual stenoses were 2. 04±0. 16 mm and 20 %±7 %respectively (P<0. 05 and P<0. 01), Complication in form of vasoperforation occurred in 3/20 vessels (15%). It is concluded that China-manufactured excimerlaser angioplasty is effective when used for revascularization. While the reduction of narrowing and residual stenoses was enhanced after adjunction of balloon angioplasty. This method can be employed in treating peripheral occlusive disease effectively and safely. 展开更多
关键词 excimer laser balloon thrombus ANGIOPLASTY
暂未订购
EXCIMER LASER CORONARY ANGIOPLASTY ──A PRELIMINARY REPORT OF 11 CASES
15
作者 陈万春 金惠根 +2 位作者 金立仁 王肖龙 胡伟国 《Medical Bulletin of Shanghai Jiaotong University》 CAS 1995年第2期7-11,共5页
We reported 11 cases of excimer laser coronary angioplasty (ELCA). All were males, the average age being 59.7 years. Five patients had sustained previous myocardial infarctions with post-infarction angina in 2 cases a... We reported 11 cases of excimer laser coronary angioplasty (ELCA). All were males, the average age being 59.7 years. Five patients had sustained previous myocardial infarctions with post-infarction angina in 2 cases and 6 presented angina only. Coronary angiograms showed stenosis in LAD (N9), LCX(N6) and RCA (N6). According to the ACC/AHA classification, 6 were categorized as type B, and 5 type C. ELCA with adjunctive PTCA were performed in all 8 patients, 1. 3 mm (energy density 14. 5 mJ) and 1.6 mm (energy density 21.0 mJ) laser catheters with 20Hz pulse frequency were used There was one failure and in another ELCA was successful but death followed the procedure. The overall result was laser success 10 out of the 11 cases and procedure success 9. 展开更多
关键词 CORONARY ATHEROSCLEROSIS excimer laser CORONARY ANGIOPLASTY PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
暂未订购
Phosphorus diffusion and activation in fluorine co-implanted germanium after excimer laser annealing
16
作者 Chen Wang Wei-Hang Fan +4 位作者 Yi-Hong Xu Yu-Chao Zhang Hui-Chen Fan Cheng Li Song-Yan Cheng 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第9期619-623,共5页
The diffusion and the activation of phosphorus in phosphorus and fluorine co-implanted Ge after being annealed by excimer laser are investigated.The results prove that the fluorine element plays an important role in s... The diffusion and the activation of phosphorus in phosphorus and fluorine co-implanted Ge after being annealed by excimer laser are investigated.The results prove that the fluorine element plays an important role in suppressing phosphorus diffusion and enhancing phosphorus activation.Moreover,the rapid thermal annealing process is utilized to evaluate and verify the role of fluorine element.During the initial annealing of co-implanted Ge,it is easier to form high bonding energy FnVm clusters which can stabilize the excess vacancies,resulting in the reduced vacancy-assisted diffusion of phosphorus.The maximum activation concentration of about 4.4 ×10^(20) cm^(-3) with a reduced diffusion length and dopant loss is achieved in co-implanted Ge that is annealed at a tailored laser fluence of 175 mJ/cm^(2).The combination of excimer laser annealing and co-implantation technique provides a reference and guideline for high level n-type doping in Ge and is beneficial to its applications in the scaled Ge MOSFET technology and other devices. 展开更多
关键词 phosphorus diffusion activation concentration co-implanted fluorine GERMANIUM excimer laser annealing
原文传递
Evaluation of Clinical Outcomes after LASIK for the Correction of Myopia Using the Advanced Customvue Excimer Laser Platform
17
作者 Hung Ming Lee 《Open Journal of Ophthalmology》 2018年第3期150-160,共11页
-Purpose: To evaluate early visual, refractive and aberrometric outcomes after wave front-guided LASIK for the correction of low to moderate myopia and myopic astigmat is musing the excimer laser platform Advanced Cus... -Purpose: To evaluate early visual, refractive and aberrometric outcomes after wave front-guided LASIK for the correction of low to moderate myopia and myopic astigmat is musing the excimer laser platform Advanced Custom Vue. Methods: A prospective, non-comparative study in 100 myopic eyes of 50 patients evaluating LASIK results over a period of 3 months. Main outcome variables included visual acuity, refraction, total higher-order aberrations (HOAs), spherical aberration (SA) and coma-like aberration. The surgery was performed using the VISX STAR S4 (Johnson and Johnson Vision) excimer laser and a wave front-guided ablation designed according to the iDesign aberrometer data (Johnson and Johnson Vision). Results: Mean preoperative sphere decreased from -4.07 ± 1.78 D to 0.32 ± 0.30 D at 3 months after surgery. Mean preoperative cylinder was reduced from -1.09 ± 0.88 D to -0.26 ± 0.28 D after the complete follow-up. Postoperative uncorrected distance visual acuity (UDVA) was 0.00 logMAR (20/20) or better in 100% of eyes, and 65.3% of eyes reached an UDVA of -0.20 logMAR (20/12.5) or better (p < 0.05). For a 6-mm pupil, the root mean square (RMS) for total ocular HOAs increased with surgery by 0.03 μm (p = 0.050), whereas the coma-like RMS increased by 0.05 μm (p < 0.001). The change in spherical aberration was +0.08 μm (p < 0.001). Conclusion: Wavefront-guided LASIK using the new generation excimer laser platform Advanced Custom Vue is safe and effective for treating myopia and myopic astigmatism, minimizing the postoperative level of HOAs. 展开更多
关键词 excimer laser LASIK Wavefront-Guided MYOPIA HIGHER-ORDER ABERRATIONS
暂未订购
Suicide after Excimer Laser Refractive Surgery: On the Importance of Matching Expectations
18
作者 Gysbert van Setten 《Open Journal of Ophthalmology》 2015年第3期145-148,共4页
Background: Refractive surgery may change the individual life to the better largely eliminating the need for spectacles. However, expectations may vary and postoperative reality may come as a surprise. Aim: To emphasi... Background: Refractive surgery may change the individual life to the better largely eliminating the need for spectacles. However, expectations may vary and postoperative reality may come as a surprise. Aim: To emphasize the need for thorough alignment of expectations and options between surgeon and patient. Methods: A case is presented in which a successful refractive laser operation is a part of a trigger mechanism for a depressive episode leading to suicide. It emphasizes the crucial importance of constructive alignment of expectations between patient and treating physician prior to surgery. Results: The case presented outlines that ophthalmic surgery at the edge of high-tec with all its tempting features is also very attractive to individuals with very well defined and less flexible expectations. The possible irreversibility of some of the refractive surgery may force the patient postoperatively into a psychological corner, immobilizing him/her and restricting his/her options. Conclusions: High-tec operations dealing with one of the most elementary senses we have, vision, demand a thorough estimation of the patients profile prior to any surgery. Only matching expectations between the possible and desired outcome and reconfirmation of the match may reduce the risk of postoperative crisis which may carry a risk the patient’s life. 展开更多
关键词 SUICIDE excimer laser SURGERY OPHTHALMOLOGY Refractive SURGERY
暂未订购
Surface Modification of Ceramic Materials Using Excimer Laser
19
作者 Yingna WU, Zhongchao FENG and Jing LIANG (Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110015, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第4期401-404,共4页
Changes of surface morphology following XeCI excimer laser irradiation were investigated for three engineering ceramic materials (Al2O3, Al2O3-SiC nanocomposite and Si3N4). Al2O3 and AI2O3-SiC nanocomposite samples ex... Changes of surface morphology following XeCI excimer laser irradiation were investigated for three engineering ceramic materials (Al2O3, Al2O3-SiC nanocomposite and Si3N4). Al2O3 and AI2O3-SiC nanocomposite samples exhibit a smooth rapid melt layer on the surface, and the formation of the metastabfe γ-Al2Oa was observed. A silicon-rich layer on the surface was formed after laser irradiation of Si3N4. The toughness K1c of the materials was measured by the indentation fracture method. After laser irradiation, the toughness of Al2O3, Al2O3-SiC nanocomposite and Si3N4 was improved to various degrees: Al2O3-SiC nanocomposite, 60% (max.); AI203, 40% (max.); Si3N4, 12% (max.). 展开更多
关键词 Surface Modification of Ceramic Materials Using excimer laser SIC
在线阅读 下载PDF
Ceramics Surface Modification by Excimer Laser Metal Coating
20
作者 Weidou ZHU and Haicheng GU(Dept. of Materials Science and Engineering, Xi’an Jiaotong University, Xi’an, 710049, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1994年第6期463-465,共3页
Thin metallic layers (~ 2 μm) of Ni were deposited on polycrystalline Al2O3. ZrO2 and (Ce-TZP)+Al2O3 ceramic substrates. and further irradiated with pulsed excimer (Xeno chloride) laser pulses. The laser energy densi... Thin metallic layers (~ 2 μm) of Ni were deposited on polycrystalline Al2O3. ZrO2 and (Ce-TZP)+Al2O3 ceramic substrates. and further irradiated with pulsed excimer (Xeno chloride) laser pulses. The laser energy density was varied from 0.21 to 0.81 J / cm2 to optimize bending strength. For ZrO2 ceramic, it was found that the strength increases from 530 to 753 MPa at 0.51 J / cm2 irradiation. For Al2O3 and (Ce-TZP)+ Al2O3 the fracture strength also increases in varying degree. The causes of strength increment were discussed. 展开更多
关键词 Ceramics Surface Modification by excimer laser Metal Coating RES
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部