A single column model (SCM) is constructed by extracting the physical subroutines from the NCAR Community Climate Model version 1 (CCM1).Simulated data are generated by CCM1 and used to validate the SCM and to study t...A single column model (SCM) is constructed by extracting the physical subroutines from the NCAR Community Climate Model version 1 (CCM1).Simulated data are generated by CCM1 and used to validate the SCM and to study the sensitivity of the SCM to errors in its input data.It is found that the SCM temperature predictions are moderately sensitive to errors in the input horizontal temperature flux convergence and moisture flux convergence.Two types of error are concerned in this study,random errors due to insufficient data resolution,and errors due to insufficient data area coverage.While the first type of error can be reduced by filtering and/or increasing the data resolution,it is shown that the second type of error can be reduced by enlarging the data area coverage and using a suitable method to compute the input flux convergence terms.展开更多
An error analysis of the dynamic shear modulus of stiff specimens from tests performed by a new resonant column device developed by the Institute of Engineering Mechanics, China was conducted. A modified approach for ...An error analysis of the dynamic shear modulus of stiff specimens from tests performed by a new resonant column device developed by the Institute of Engineering Mechanics, China was conducted. A modified approach for calculating the dynamic shear modulus of the stiff specimens is presented. The error formula of the tests was deduced and parameters that impact the accuracy of the test were identified. Using six steel specimens with known standard stiffness as a base, a revised dynamic shear modulus calculation for stiff specimens was formulated by comparing three of the models. The maximum error between the test results and the calculated results shown by curves from both the free-vibration and the resonant-vibration tests is less than 6%. The free-vibration and resonant-vibration tests for three types of stiff samples with a known modulus indicate that the maximum deviation between the actual and the tested value using the modified approach were less than 10%. As a result, the modified approach presented here is shown to be reliable and the new device can be used for testing dynamic shear modulus of any stiff materials at low shear strain levels展开更多
文摘A single column model (SCM) is constructed by extracting the physical subroutines from the NCAR Community Climate Model version 1 (CCM1).Simulated data are generated by CCM1 and used to validate the SCM and to study the sensitivity of the SCM to errors in its input data.It is found that the SCM temperature predictions are moderately sensitive to errors in the input horizontal temperature flux convergence and moisture flux convergence.Two types of error are concerned in this study,random errors due to insufficient data resolution,and errors due to insufficient data area coverage.While the first type of error can be reduced by filtering and/or increasing the data resolution,it is shown that the second type of error can be reduced by enlarging the data area coverage and using a suitable method to compute the input flux convergence terms.
基金Ministry of Science and Technology of Chinaand the Earthquake Science Foundation of China Under GrandNo.102033
文摘An error analysis of the dynamic shear modulus of stiff specimens from tests performed by a new resonant column device developed by the Institute of Engineering Mechanics, China was conducted. A modified approach for calculating the dynamic shear modulus of the stiff specimens is presented. The error formula of the tests was deduced and parameters that impact the accuracy of the test were identified. Using six steel specimens with known standard stiffness as a base, a revised dynamic shear modulus calculation for stiff specimens was formulated by comparing three of the models. The maximum error between the test results and the calculated results shown by curves from both the free-vibration and the resonant-vibration tests is less than 6%. The free-vibration and resonant-vibration tests for three types of stiff samples with a known modulus indicate that the maximum deviation between the actual and the tested value using the modified approach were less than 10%. As a result, the modified approach presented here is shown to be reliable and the new device can be used for testing dynamic shear modulus of any stiff materials at low shear strain levels