Recently,switched Ethernet has become an active area of research because of its wide uses in industry.However,its uses have various real-time constraints on data communications.This paper analyzes the performance of t...Recently,switched Ethernet has become an active area of research because of its wide uses in industry.However,its uses have various real-time constraints on data communications.This paper analyzes the performance of the line topology switched Ethernet as a data acquisition network.Network calculus theory,which has been successfully applied to assess the real-time performance of packet-switched networks,is used to analyze the networks.To properly describe the activity of switches,a novel approach of modeling data flows into or out of switches is addressed.Based on our model,a concisely analytical expression of the maximal end-to-end delay in line topology switched Ethernet is derived.Finally,the relative simulation results are demonstrated.These results agree well with the analytical results,and thus they validate the data flow modeling techniques.展开更多
An open-ended coaxial line reflection method especially suitable for meas-uring the dielectric properties of biological tissue in vivo is described.This method offersthe advantage of not requiring any special preparat...An open-ended coaxial line reflection method especially suitable for meas-uring the dielectric properties of biological tissue in vivo is described.This method offersthe advantage of not requiring any special preparation of the samples to be measured but aclose contact with the open end of a coaxial line.It is,therefore,very convenient to acquirea large number of measurement data in broad band rapidly.The method may also be usedto measure the properties of other substances.The measuring system consists of a networkanalyzer controlled by a microcomputer and calibrated by using ANA procedure to elimi-hate the influnce of error network introduced by the adapter,some connectors,etc.In or-der to reach higher accuracy,the iterative method is used to determine the parameters ofthe equivalent circuit.Measurements of permeativities of some living tissues have been per-formed in the frequency band of 0.5-2GHz.Compared with the results known in somepapers,the validity of this method has been confirmed.The difference in dielectric proper-ties between living and dead tissues,and the tissue permeativites(ε)versus frequency andduration of measurement after death have also been measured.展开更多
文摘Recently,switched Ethernet has become an active area of research because of its wide uses in industry.However,its uses have various real-time constraints on data communications.This paper analyzes the performance of the line topology switched Ethernet as a data acquisition network.Network calculus theory,which has been successfully applied to assess the real-time performance of packet-switched networks,is used to analyze the networks.To properly describe the activity of switches,a novel approach of modeling data flows into or out of switches is addressed.Based on our model,a concisely analytical expression of the maximal end-to-end delay in line topology switched Ethernet is derived.Finally,the relative simulation results are demonstrated.These results agree well with the analytical results,and thus they validate the data flow modeling techniques.
文摘An open-ended coaxial line reflection method especially suitable for meas-uring the dielectric properties of biological tissue in vivo is described.This method offersthe advantage of not requiring any special preparation of the samples to be measured but aclose contact with the open end of a coaxial line.It is,therefore,very convenient to acquirea large number of measurement data in broad band rapidly.The method may also be usedto measure the properties of other substances.The measuring system consists of a networkanalyzer controlled by a microcomputer and calibrated by using ANA procedure to elimi-hate the influnce of error network introduced by the adapter,some connectors,etc.In or-der to reach higher accuracy,the iterative method is used to determine the parameters ofthe equivalent circuit.Measurements of permeativities of some living tissues have been per-formed in the frequency band of 0.5-2GHz.Compared with the results known in somepapers,the validity of this method has been confirmed.The difference in dielectric proper-ties between living and dead tissues,and the tissue permeativites(ε)versus frequency andduration of measurement after death have also been measured.