期刊文献+
共找到1,202篇文章
< 1 2 61 >
每页显示 20 50 100
Influence of polyethylene glycol on pore structure and electric double-layer capacitance of carbon xerogel
1
作者 侯朝辉 李新海 +2 位作者 何则强 刘恩辉 邓凌峰 《Journal of Central South University of Technology》 2004年第3期255-260,共6页
Mesoporous polyethylene glycol-resorcinol and formaldehyde(PEG-RF) carbon xerogels were prepared by a new polymer blend method in which PEG-RF mixed organic xerogels were synthesized by blending thermally unstable p... Mesoporous polyethylene glycol-resorcinol and formaldehyde(PEG-RF) carbon xerogels were prepared by a new polymer blend method in which PEG-RF mixed organic xerogels were synthesized by blending thermally unstable polyethylene glycol with organic monomers, resorcinol and formaldehyde and then subjected to pyrolization at 1 000 ℃. The influences of mass ratio of PEG to the theoretical yield of RF xerogel, m(PEG)/m(RF) and the (relative) molecular mass of PEG on the pore structure and electric double layer capacitance(EDLC) performance of PEG-RF carbon xerogels were investigated. The results show that PEG under different conditions leads to the difference of phase separation structure of the polymer blend and thus the change of pore structure of PEG-RF carbon xerogels. Specific surface area and capacity of PEG-RF carbon xerogels in 30% H2SO4 solution can reach (755 m2/g) and 150 F/g, respectively. Their surface can be fully utilized to form electric double layer. However, the pore structure differences of PEG-RF carbon xerogels result in their different EDLC performances. The distributed capacitance effect increases with decreasing the pore size of PEG-RF carbon xerogels. 展开更多
关键词 polymer blend method polyethylene glycol carbon xerogel electric double-layer capacitance
在线阅读 下载PDF
Preparation of nitrogen-doped activated carbon from palm oil empty fruit bunches for electrodes in electric double-layer capacitance-type supercapacitors:effect of pyrolysis temperature
2
作者 Ria Yolanda Arundina Resti Marlina +5 位作者 Eny Kusrini Anwar Usman Achmad Subhan Fredina Destyorini Agus Budi Prasetyo Bambang Subiyanto 《Clean Energy》 2025年第2期99-110,共12页
In this study,activated carbon was synthesized from palm oil empty fruit bunches through two different carbonization and activation processes and was used as carbon-based electrodes for supercapacitor.The activated ca... In this study,activated carbon was synthesized from palm oil empty fruit bunches through two different carbonization and activation processes and was used as carbon-based electrodes for supercapacitor.The activated carbon was produced by a combination of the hydrothermal and pyrolysis methods using melamine as a nitrogen source dopant and potassium chloride as an activating agent.The effect of pyrolysis temperature on the crystalline structure,crystallite size,functional groups,and surface characteristics of the resulting activated carbon,which was applied as electrodes in an electric double-layer capacitor.The performance of the activated carbon-based electrodes was evaluated,suggesting that activated carbon prepared by pyrolysis at 950°C showed the highest specific capacitance of 389.122 F/g at a current density of 1 A/g with energy and power densities of 13.511 and 125 W/kg,respectively.Overall results suggest that palm oil empty fruit bunches are promising cellulosic sources in synthesizing activated carbon-based electrodes for supercapacitors. 展开更多
关键词 biomass electric double-layer capacitor HYDROTHERMAL nitrogen-doped activated carbon PYROLYSIS SUPERcapacitOR
原文传递
Effects of noise on fluidized bed characteristics measurements by electrical capacitance tomography
3
作者 Kai Huang Chunlei Pei +4 位作者 Shuanghe Meng Wuqiang Yang Hua Li Mao Ye Jinlong Gong 《Chinese Journal of Chemical Engineering》 2025年第3期219-233,共15页
Noise is inevitable in electrical capacitance tomography(ECT)measurements.This paper describes the influence of noise on ECT performance for measuring gas-solids fluidized bed characteristics.The noise distribution is... Noise is inevitable in electrical capacitance tomography(ECT)measurements.This paper describes the influence of noise on ECT performance for measuring gas-solids fluidized bed characteristics.The noise distribution is approximated by the Gaussian distribution and added to experimental capacitance data with various intensities.The equivalent signal strength(Ф)that equals the signal-to-noise ratio of packed beds is used to evaluate noise levels.Results show that the Pearson correlation coefficient,which indicates the similarity of solids fraction distributions over pixels,increases with Ф,and reconstructed images are more deteriorated at lower Ф.Nevertheless,relative errors for average solids fraction and bubble size in each frame are less sensitive to noise,attributed to noise compromise caused by the process of pixel values.These findings provide useful guidance for assessing the accuracy of ECT measurements of multiphase flows. 展开更多
关键词 Noise electrical capacitance tomography Fluidized bed Signal-to-noise ratio MEASUREMENT
在线阅读 下载PDF
Adsorption of K^+ from an aqueous phase onto an activated carbon used as an electric double-layer capacitor electrode 被引量:3
4
作者 LI Ying XIE Qiang +2 位作者 YAN Wen WANG Yan ZHANG Zhonghua 《Mining Science and Technology》 EI CAS 2010年第4期551-556,共6页
The adsorption capacity and absorption rate for electrolyte onto activated carbon are important parameters used to characterize activated carbon electric double-layer capacitor electrodes. In this paper the pore struc... The adsorption capacity and absorption rate for electrolyte onto activated carbon are important parameters used to characterize activated carbon electric double-layer capacitor electrodes. In this paper the pore structure of typical commercial activated carbons, and various Mn-doped activated carbons prepared on a laboratory scale, are described. The pore structure was character-ized by N2 adsorption/desorption isotherms. Isotherms for K+ adsorption onto these activated carbons from the aqueous phase were also obtained. The experimental, equilibrium K+ adsorption data were fitted to the Langmuir, Freundlich or Temkin equations. Adsorption of K+ onto the activated carbons was measured and plotted as a function of time. The adsorption kinetic data were modeled by either pseudo-first or pseudo-second order equations. The Elvoich equation, a liquid film diffusion and an intra-particle diffusion model were used to fit the kinetic data. The results indicate that the adsorption of K+ onto activated carbon is influenced by many factors including pore size distribution, specific surface area and the surface chemistry of the activated carbons. The Temkin equation best describes the equilibrium adsorption data. The pseudo-second order model exactly describes the whole adsorption process, which is controlled by both liquid film and intra-particle diffusion. 展开更多
关键词 activated carbon adsorption isotherm adsorption kinetics electric double-layer capacitor
在线阅读 下载PDF
Cobalt and nitrogen atoms co-doped porous carbon for advanced electrical double-layer capacitors 被引量:2
5
作者 Aiqin Xiang Shuai Xie +5 位作者 Fei Pan Hongchang Jin Yiheng Zhai Yanwu Zhu Xianghua Kong Hengxing Ji 《Chinese Chemical Letters》 SCIE CAS CSCD 2021年第2期830-833,共4页
Electrical double-layer capacitors are widely concerned for their high power density,long cycling life and high cycling efficiency.However,their wide application is limited by their low energy density.In this study,we... Electrical double-layer capacitors are widely concerned for their high power density,long cycling life and high cycling efficiency.However,their wide application is limited by their low energy density.In this study,we propose a simple yet environmental friendly method to synthesize cobalt and nitrogen atoms co-doped porous carbon(CoAT-NC) material.Cobalt atoms connected with primarily pyridinic nitrogen atoms can be uniformly dispersed in the amorphous carbon matrix,which is benefit for improving electrical conductivity and density of states of the carbon material.Therefore,an enhanced perfo rmance is expected when CoAT-NC is served as electrode in a supercapacitor device.CoAT-NC displays a good gravimetric capacitance of 160 F/g at 0.5 A/g combing with outstanding capacitance retention of 90% at an extremely high current density of 100 A/g in acid electrolyte.Furthermore,a good energy density of 30 Wh/kg can be obtained in the organic electrolyte. 展开更多
关键词 electrical double-layer capacitors Cobalt atoms Pyridinic nitrogen CO-DOPED Density of states
原文传递
Porous monoliths of 3D graphene for electric double-layer supercapacitors 被引量:3
6
作者 Jinjue Zeng Chenyang Xu +2 位作者 Tian Gao Xiangfen Jiang Xue‐Bin Wang 《Carbon Energy》 CAS 2021年第2期193-224,共32页
For delivering the nanoscaled extraordinary characteristics in macroscopical bulk,it is essential to integrate two-dimensional nanosheets into threedimensional(3D)porous monoliths,alternatively called as 3D architectu... For delivering the nanoscaled extraordinary characteristics in macroscopical bulk,it is essential to integrate two-dimensional nanosheets into threedimensional(3D)porous monoliths,alternatively called as 3D architectures,3D networks,or aerogels.The intersupported structure of porous monolithic 3D graphene(3DG)can prevent aggregation or restacking of graphene individuals,and the interconnected sp^(2) network of 3DG not only can provide the highway for the transport of electron/phonon but also can present continual cavities/channels for mass transfer.This review summarizes the synthesis methodology of 3DG porous monoliths and highlights the application for electric double-layer capacitors.Present challenges and future prospects about the manufacture and application of 3DG are also discussed. 展开更多
关键词 3D graphene electric double-layer capacitor graphene aerogel porous monolith supercapacitor
在线阅读 下载PDF
Characterization of Microporous Activated Carbon Electrodes for Electric Double-layer Capacitors 被引量:1
7
作者 MENGQing-han LIULing SONGHuai-he 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2004年第5期627-630,共4页
Activated carbons(ACs) with a wide range of surface areas were made from petroleum coke by means of KOH activation. The electrochemical characterization was carried out for several activated carbons used as polarizabl... Activated carbons(ACs) with a wide range of surface areas were made from petroleum coke by means of KOH activation. The electrochemical characterization was carried out for several activated carbons used as polarizable electrodes of electric double-layer capacitors(EDLCs) in an aqueous electrolytic solution. The porous structures and electrochemical double-layer capacitance of the activated carbons were investigated by virtue of nitrogen gas adsorption and constant current cycling(CCC) methods. The relationship among the surface area, pore volume of the activated carbons and specific double-layer capacitance was discussed. It was found that the specific capacitance of ACs increased linearly with the increase of surface area. The presence of mesopores in the activated carbons with very high surface area(>2000 m\+2/g) was not very effective for them to be used as EDLCs. The influence of chemical characteristics of the activated carbons on the double layer formation could be considered to be negligible. 展开更多
关键词 Micropore activated carbon electric double layer capacitor Specific capacitance
在线阅读 下载PDF
Carbon aerogels for electric double-layer capacitors 被引量:1
8
作者 ZHANG Lin LIU Hongbo WANG Ming LIU Wei 《Rare Metals》 SCIE EI CAS CSCD 2006年第z1期51-57,共7页
In this study, carbon aerogels were derived via the pyrolysis of resorcinol-formaldehyde (RF) aerogels, which were cost-effectively manufactured from RF wet gels by an ambient drying technique instead of conventional ... In this study, carbon aerogels were derived via the pyrolysis of resorcinol-formaldehyde (RF) aerogels, which were cost-effectively manufactured from RF wet gels by an ambient drying technique instead of conventional supercritical drying. By varying the R/C ratio (molar ratio of resorcinol to catalyst), mesoporous carbon aerogels with high specific surface area were prepared successfully and further investigated as electrode materials for electric double-layer capacitors (EDLCs). The textural properties of carbon aerogels obtained were characterized by nitrogen adsorption/desorption analysis and SEM. The electrochemical performances of carbon aerogels were investigated by impedance spectroscopy, galvanostatic charge/discharge and cyclic voltammetry methods. The results show that BET surface area and specific capacitance increase with R/C ratio, the maximum values of 727 m2·g-1 and 132 F·g-1 are achieved at R/C ratio will of 300. Increasing R/C ratio increase the average pore size of carbon aerogel electrode, which has improved the rate capability. Furthermore, EDLC with carbon aerogel electrodes has an excellent stability at large discharge current and long cycle life. 展开更多
关键词 carbon aerogel electric double-layer capacitors TEXTURE electrochemical performance
在线阅读 下载PDF
Preparation of spiro-type quaternary ammonium salt via economical and efficient synthetic route as electrolyte for electric double-layer capacitor 被引量:4
9
作者 周宏明 孙文佼 李荐 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第7期2435-2439,共5页
A spiro-type quaternary ammonium salt, spiro-(1,1′)-bipyrrolidinium tetrafluoroborate(SBP-BF4) was successfully prepared by an economical and efficient three-step process comprising the cyclization reaction of 1,4-di... A spiro-type quaternary ammonium salt, spiro-(1,1′)-bipyrrolidinium tetrafluoroborate(SBP-BF4) was successfully prepared by an economical and efficient three-step process comprising the cyclization reaction of 1,4-dibromobutane and pyrrolidine, and subsequent ion exchange pathway with KOH followed by neutralization reaction via HBF4 in the system of ethanol solution. 1H NMR, 13 C NMR, FI-IR and XPS analyses showed the structure of SBP-BF4. The as-obtained SBP-BF4 was dissolved in AN and used as the electrolyte for supercapacitor. Electrochemical measurements demonstrate that, compared with commercial electrolyte TEMA-BF4/AN, SBP-BF4/AN exhibits high ionic conductivity, lower resistance and improved cycling performance, which is due to its smaller ion size and stable symmetry structure. 展开更多
关键词 spiro-type quaternary ammonium salt synthesis electrolyte electric double-layer capacitor
在线阅读 下载PDF
Aplication of Corncob-Based Activated Carbon as Electrode Material for Electric Double-Layer Capacitors
10
作者 王玉新 刘炳泗 +1 位作者 时志强 刘凤丹 《Transactions of Tianjin University》 EI CAS 2012年第3期217-223,共7页
To investigate the influence of expansion pretreatment for materials on carbon structure, activated carbons (ACs) were prepared from corncob with/without expansion pretreatment by KOH activation, the structure prope... To investigate the influence of expansion pretreatment for materials on carbon structure, activated carbons (ACs) were prepared from corncob with/without expansion pretreatment by KOH activation, the structure properties of which were determined based on N2 adsorption isotherm at 77 K. The results show that the expansion pretreatment for corncobs is beneficial to the preparation of ACs with high surface area. The specific surface area of the AC derived from corncob with expansion pretreatment (AC-1) is 32.5% larger than that without expansion pretreatment (AC-2). Furthermore, to probe the potential application of corncob-based ACs in electric double-layer capacitor (EDLC), the prepared ACs were used as electrode materials to assemble EDLC, and its electrochemical performance was investi- gated. The results indicate that the specific capacitance of AC-I is 276 F/g at 50 mA/g, which increases by 27% com- pared with that of AC-2 (217 F/g). As electrode materials, AC-1 presents a better electrochemical performance than AC-2, including a higher voltage maintenance ratio and a lower leakage current. 展开更多
关键词 corncob-based activated carbon electrode material electric double-layer capacitor
在线阅读 下载PDF
Void Fraction Measurement in Oil-Gas Transportation Pipeline Using an Improved Electrical Capacitance Tomography System 被引量:5
11
作者 牛刚 贾志海 王经 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2004年第4期476-481,共6页
To measure the void fraction online in oil-gas pipeline, an improved electrical capacitance tomography (ECT) system has been designed. The capacitance sensor with new structure has twelve internal electrodes and overc... To measure the void fraction online in oil-gas pipeline, an improved electrical capacitance tomography (ECT) system has been designed. The capacitance sensor with new structure has twelve internal electrodes and overcomes the influence of the pipe wall. The data collection system is improved by using high performance IC (integrated circuit). Static tests of bubble flow, stratified flow and annular flow regime are carried out. Measurements are taken on bubble flow, stratified flow and slug flow. Results show that the new ECT system performs well on void fraction measurement of bubble flow and stratified flow, but the error of measurement for slug flow is more than 10%. 展开更多
关键词 electrical capacitance tomography void fraction MEASUREMENT oil-gas transportation
在线阅读 下载PDF
Application of Electrical Capacitance Tomography to the Concentration Measurement in a Cyclone Dipleg 被引量:5
12
作者 孙猛 刘石 +1 位作者 李志宏 雷兢 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第4期635-639,共5页
Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computatio... Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computational models. Online measurements can be used for active control. Electrical capacitance tomography (ECT) is a unique measuring technique with great potential in multiphase flow measurement. Experimental studies are carried out on a solid concentration measurement in a cyclone separator dipleg, using ECT. In this experiment eight electrodes are selected for the ECT sensor that is placed on the straight tube of the dipleg. The fluctuating characteristics according to the screw feeder and the effect of the airflow rate from the top of the cyclone are analyzed. The feasibility andreliability of the method are verified by the experimental results. 展开更多
关键词 electrical capacitance tomography concentration measurement cyclone separator dipleg gas-solid two-phase flow
在线阅读 下载PDF
Flame Imaging in Meso-scale Porous Media Burner Using Electrical Capacitance Tomography 被引量:5
13
作者 陈琪 刘石 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第2期329-336,共8页
This study was conducted to investigate the characteristics of meso-scale combustion.The technique of electrical capacitance tomography(ECT) was used to locate flame position and monitor the effect corresponding to va... This study was conducted to investigate the characteristics of meso-scale combustion.The technique of electrical capacitance tomography(ECT) was used to locate flame position and monitor the effect corresponding to varied air/fuel ratio in a meso-scale combustor.Combustion phenomena including igniting,quenching and unsteady combustion have been visualized using ECT.The method of metallization protecting ECT sensor from high temperature damage and the novel calibration method adapted to ECT monitoring of unknown permittivity flame have been shown to be successful.At the same time,electrical nature of combustion and dielectric characteristics of hy-drocarbon flame were studied.The relationship between flame permittivity and state parameters of combustion gas was demonstrated preliminarily. 展开更多
关键词 electr:ical capacitance tomography meso-scale burner COMBUSTION flame permittivity
在线阅读 下载PDF
Empirical formulae for electric double-layer repulsion between two arbitrarily inclined clay particles 被引量:3
14
作者 Xiangyu Shang Juming Lu +2 位作者 Lianfei Kuang Chen Yang Guoqing Zhou 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2018年第6期1183-1189,共7页
To understand the mesoscopic mechanism of clayey soil in view of macroscopic behavior, it is essential to quantitatively calculate the electric double-layer repulsion between arbitrarily inclined clay particles.Howeve... To understand the mesoscopic mechanism of clayey soil in view of macroscopic behavior, it is essential to quantitatively calculate the electric double-layer repulsion between arbitrarily inclined clay particles.However, suitable calculation methods with high efficiency and accuracy are still rare at present in literature. Based on a great number of numerical calculations of the repulsion between two inclined platy clay particles, explicit empirical formulae for estimating electric double-layer repulsion between clay particles are put forward. Comparison between the empirical solutions and corresponding numerical results shows that the proposed formulae have a reasonable accuracy, and application of the presented formula is easy and efficient. 展开更多
关键词 Clay particles electric double-layer repulsion Numerical analysis Empirical formula
在线阅读 下载PDF
Reconstruction of electrical capacitance tomography images based on fast linearized alternating direction method of multipliers for two-phase flow system 被引量:4
15
作者 Chongkun Xia Chengli Su +1 位作者 Jiangtao Cao Ping Li 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第5期597-605,共9页
Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed ... Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed and nonlinear inverse problem of ECT image reconstruction,a new ECT image reconstruction method based on fast linearized alternating direction method of multipliers(FLADMM)is proposed in this paper.On the basis of theoretical analysis of compressed sensing(CS),the data acquisition of ECT is regarded as a linear measurement process of permittivity distribution signal of pipe section.A new measurement matrix is designed and L1 regularization method is used to convert ECT inverse problem to a convex relaxation problem which contains prior knowledge.A new fast alternating direction method of multipliers which contained linearized idea is employed to minimize the objective function.Simulation data and experimental results indicate that compared with other methods,the quality and speed of reconstructed images are markedly improved.Also,the dynamic experimental results indicate that the proposed algorithm can ful fill the real-time requirement of ECT systems in the application. 展开更多
关键词 electrical capacitance tomography Image reconstruction Compressed sensing Alternating direction method of multipliers Two-phase flow
在线阅读 下载PDF
Dynamic Visualization Approach of the Multiphase Flow Using Electrical Capacitance Tomography 被引量:1
16
作者 王泽璞 陈琪 +2 位作者 王雪瑶 李志宏 韩振兴 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第2期380-388,共9页
Identifying the flow patterns is vital for understanding the complicated physical mechanisms in multiphase flows.For this purpose,electrical capacitance tomography(ECT) technique is considered as a promising visualiza... Identifying the flow patterns is vital for understanding the complicated physical mechanisms in multiphase flows.For this purpose,electrical capacitance tomography(ECT) technique is considered as a promising visualization method for the flow pattern identification,in which image reconstruction algorithms play an important role.In this paper,a generalized dynamic reconstruction model,which integrates ECT measurement information and physical evolution information of the objects of interest,was presented.A generalized objective functional that simultaneously considers the spatial constraints,temporal constraints and dynamic evolution information of the objects of interest was proposed.Numerical simulations and experiments were implemented to evaluate the feasibility and efficiency of the proposed algorithm.For the cases considered in this paper,the proposed algorithm can well reconstruct the flow patterns,and the quality of the reconstructed images is improved,which indicates that the proposed algorithm is competent to reconstruct the flow patterns in the visualization of multiphase flows. 展开更多
关键词 electrical capacitance tomography VISUALIZATION flow pattern identification dynamic reconstruction algorithm
在线阅读 下载PDF
Voidage measurement based on genetic algorithm and electrical capacitance tomography 被引量:1
17
作者 王微微 王保良 +1 位作者 黄志尧 李海青 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第12期1441-1445,共5页
A new voidage measurement method based on electrical capacitance tomography (ECT) technique, Genetic Algo- rithm (GA) and Partial Least Square (PLS) method was proposed. The voidage measurement model, linear capacitan... A new voidage measurement method based on electrical capacitance tomography (ECT) technique, Genetic Algo- rithm (GA) and Partial Least Square (PLS) method was proposed. The voidage measurement model, linear capacitance combi- nation, was developed to measure on-line voidage. GA and PLS method were used to determine the coefficients of the voidage measurement model. GA was used to explore the optimal capacitance combination which gave significant contribution to the voidage measurement. PLS method was applied to determine the weight coefficient of the contribution of each capacitance to the voidage measurement. Flow pattern identification result was introduced to improve the voidage measurement accuracy. Experi- mental results showed that the proposed voidage measurement method is effective and that the measurement accuracy is satis- factory. 展开更多
关键词 VOIDAGE Two-phase flow Genetic Algorithm (GA) electrical capacitance tomography (ECT)
在线阅读 下载PDF
Visualization Detection of Solid-Liquid Two-Phase Flow in Filling Pipeline by Electrical Capacitance Tomography Technology 被引量:1
18
作者 Ningbo Jing Mingqiao Li +3 位作者 Lang Liu Yutong Shen Peijiao Yang Xuebin Qin 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第4期465-476,共12页
During mine filling,the caking in the pipeline and the waste rock in the filling slurry may cause serious safety accidents such as pipe blocking or explosion.Therefore,the visualization of the innermine filling of the... During mine filling,the caking in the pipeline and the waste rock in the filling slurry may cause serious safety accidents such as pipe blocking or explosion.Therefore,the visualization of the innermine filling of the solid-liquid two-phase flow in the pipeline is important.This paper proposes a method based on capacitance tomography for the visualization of the solid-liquid distribution on the section of a filling pipe.A feedback network is used for electrical capacitance tomography reconstruction.This reconstruction method uses radial basis function neural network fitting to determine the relationship between the capacitance vector and medium distribution error.In the reconstruction process,the error in the linear back projection is removed;thus,the reconstruction problem becomes an accurate linear problem.The simulation results showthat the reconstruction accuracy of this algorithm is better than that of many traditional algorithms;furthermore,the reconstructed image artifacts are fewer,and the phase distribution boundary is clearer.This method can help determine the location and size of the caking and waste rock in the cross section of the pipeline more accurately and has great application prospects in the visualization of filling pipelines in mines. 展开更多
关键词 electrical capacitance tomography mine backfilling visualization detection image reconstruction radial basis function neural network
在线阅读 下载PDF
Damage Detection for CFRP Based on Planar Electrical Capacitance Tomography 被引量:1
19
作者 Wenru Fan Chi Wang 《Structural Durability & Health Monitoring》 EI 2020年第4期303-314,共12页
Due to the widespread use of carbon fiber reinforced polymer/plastic(CFRP),the nondestructive structural health monitoring for CFRP is playing an increasingly essential role.As a nonrad iative,noninvasive and nondestr... Due to the widespread use of carbon fiber reinforced polymer/plastic(CFRP),the nondestructive structural health monitoring for CFRP is playing an increasingly essential role.As a nonrad iative,noninvasive and nondestructive detection technique,planar electrical capacitance tomography(PECT)electrodes array is employed in this paper to reconstruct the damage image according to the calculated dielectric constant changes.The shape and duty ratio of PECT electro-des are optimized according to the relations between sensitivity distribution and the dielectric constant of different anisotropic degrees.The sensitivity matrix of optimized PECT sensor is more uniform as the result shows,because the sensitiv-ity of insensitivity area can be increased by adding rotation of optimized electro-des.The reconstructed image qualities due to different PECT arrays and different damage locations are investigated at last.The simulation results indicate that:PECT can be used to detect the surface damage of CFRP;the sensitivity matrix of PECT for CFRP is highly relevant with the degree of anisotropic dielectric con-stant;the rotatable PECT sensor with rotation has better performance in unifor-mity of sensitivity;for different damage locations,the rotatable sensor with rotation has better image quality in most cases. 展开更多
关键词 Planar electrical capacitance tomography(PECT) carbon fiber reinforced polymer/plastic(CFRP) damage detection image reconstruction
在线阅读 下载PDF
An Advanced Algorithm of Electrical Capacitance Tomography
20
作者 Yan Jie Guo Hongxing Bao Zongti 《Wuhan University Journal of Natural Sciences》 CAS 1999年第1期79-83,共5页
We describe a new two phase flow electrical capacitance tomography algorithm of image reconstruction which is based on 12 electrode capacitance transducers. According to the result of computer simulation, this algor... We describe a new two phase flow electrical capacitance tomography algorithm of image reconstruction which is based on 12 electrode capacitance transducers. According to the result of computer simulation, this algorithm is able to greatly increase the imaging fidelity without decreasing the imaging velocity. 展开更多
关键词 electrical capacitance tomography sensitivity distribution FEM
在线阅读 下载PDF
上一页 1 2 61 下一页 到第
使用帮助 返回顶部