Noise is inevitable in electrical capacitance tomography(ECT)measurements.This paper describes the influence of noise on ECT performance for measuring gas-solids fluidized bed characteristics.The noise distribution is...Noise is inevitable in electrical capacitance tomography(ECT)measurements.This paper describes the influence of noise on ECT performance for measuring gas-solids fluidized bed characteristics.The noise distribution is approximated by the Gaussian distribution and added to experimental capacitance data with various intensities.The equivalent signal strength(Ф)that equals the signal-to-noise ratio of packed beds is used to evaluate noise levels.Results show that the Pearson correlation coefficient,which indicates the similarity of solids fraction distributions over pixels,increases with Ф,and reconstructed images are more deteriorated at lower Ф.Nevertheless,relative errors for average solids fraction and bubble size in each frame are less sensitive to noise,attributed to noise compromise caused by the process of pixel values.These findings provide useful guidance for assessing the accuracy of ECT measurements of multiphase flows.展开更多
Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computatio...Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computational models. Online measurements can be used for active control. Electrical capacitance tomography (ECT) is a unique measuring technique with great potential in multiphase flow measurement. Experimental studies are carried out on a solid concentration measurement in a cyclone separator dipleg, using ECT. In this experiment eight electrodes are selected for the ECT sensor that is placed on the straight tube of the dipleg. The fluctuating characteristics according to the screw feeder and the effect of the airflow rate from the top of the cyclone are analyzed. The feasibility andreliability of the method are verified by the experimental results.展开更多
To measure the void fraction online in oil-gas pipeline, an improved electrical capacitance tomography (ECT) system has been designed. The capacitance sensor with new structure has twelve internal electrodes and overc...To measure the void fraction online in oil-gas pipeline, an improved electrical capacitance tomography (ECT) system has been designed. The capacitance sensor with new structure has twelve internal electrodes and overcomes the influence of the pipe wall. The data collection system is improved by using high performance IC (integrated circuit). Static tests of bubble flow, stratified flow and annular flow regime are carried out. Measurements are taken on bubble flow, stratified flow and slug flow. Results show that the new ECT system performs well on void fraction measurement of bubble flow and stratified flow, but the error of measurement for slug flow is more than 10%.展开更多
Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed ...Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed and nonlinear inverse problem of ECT image reconstruction,a new ECT image reconstruction method based on fast linearized alternating direction method of multipliers(FLADMM)is proposed in this paper.On the basis of theoretical analysis of compressed sensing(CS),the data acquisition of ECT is regarded as a linear measurement process of permittivity distribution signal of pipe section.A new measurement matrix is designed and L1 regularization method is used to convert ECT inverse problem to a convex relaxation problem which contains prior knowledge.A new fast alternating direction method of multipliers which contained linearized idea is employed to minimize the objective function.Simulation data and experimental results indicate that compared with other methods,the quality and speed of reconstructed images are markedly improved.Also,the dynamic experimental results indicate that the proposed algorithm can ful fill the real-time requirement of ECT systems in the application.展开更多
This study was conducted to investigate the characteristics of meso-scale combustion.The technique of electrical capacitance tomography(ECT) was used to locate flame position and monitor the effect corresponding to va...This study was conducted to investigate the characteristics of meso-scale combustion.The technique of electrical capacitance tomography(ECT) was used to locate flame position and monitor the effect corresponding to varied air/fuel ratio in a meso-scale combustor.Combustion phenomena including igniting,quenching and unsteady combustion have been visualized using ECT.The method of metallization protecting ECT sensor from high temperature damage and the novel calibration method adapted to ECT monitoring of unknown permittivity flame have been shown to be successful.At the same time,electrical nature of combustion and dielectric characteristics of hy-drocarbon flame were studied.The relationship between flame permittivity and state parameters of combustion gas was demonstrated preliminarily.展开更多
A new voidage measurement method based on electrical capacitance tomography (ECT) technique, Genetic Algo- rithm (GA) and Partial Least Square (PLS) method was proposed. The voidage measurement model, linear capacitan...A new voidage measurement method based on electrical capacitance tomography (ECT) technique, Genetic Algo- rithm (GA) and Partial Least Square (PLS) method was proposed. The voidage measurement model, linear capacitance combi- nation, was developed to measure on-line voidage. GA and PLS method were used to determine the coefficients of the voidage measurement model. GA was used to explore the optimal capacitance combination which gave significant contribution to the voidage measurement. PLS method was applied to determine the weight coefficient of the contribution of each capacitance to the voidage measurement. Flow pattern identification result was introduced to improve the voidage measurement accuracy. Experi- mental results showed that the proposed voidage measurement method is effective and that the measurement accuracy is satis- factory.展开更多
Identifying the flow patterns is vital for understanding the complicated physical mechanisms in multiphase flows.For this purpose,electrical capacitance tomography(ECT) technique is considered as a promising visualiza...Identifying the flow patterns is vital for understanding the complicated physical mechanisms in multiphase flows.For this purpose,electrical capacitance tomography(ECT) technique is considered as a promising visualization method for the flow pattern identification,in which image reconstruction algorithms play an important role.In this paper,a generalized dynamic reconstruction model,which integrates ECT measurement information and physical evolution information of the objects of interest,was presented.A generalized objective functional that simultaneously considers the spatial constraints,temporal constraints and dynamic evolution information of the objects of interest was proposed.Numerical simulations and experiments were implemented to evaluate the feasibility and efficiency of the proposed algorithm.For the cases considered in this paper,the proposed algorithm can well reconstruct the flow patterns,and the quality of the reconstructed images is improved,which indicates that the proposed algorithm is competent to reconstruct the flow patterns in the visualization of multiphase flows.展开更多
During mine filling,the caking in the pipeline and the waste rock in the filling slurry may cause serious safety accidents such as pipe blocking or explosion.Therefore,the visualization of the innermine filling of the...During mine filling,the caking in the pipeline and the waste rock in the filling slurry may cause serious safety accidents such as pipe blocking or explosion.Therefore,the visualization of the innermine filling of the solid-liquid two-phase flow in the pipeline is important.This paper proposes a method based on capacitance tomography for the visualization of the solid-liquid distribution on the section of a filling pipe.A feedback network is used for electrical capacitance tomography reconstruction.This reconstruction method uses radial basis function neural network fitting to determine the relationship between the capacitance vector and medium distribution error.In the reconstruction process,the error in the linear back projection is removed;thus,the reconstruction problem becomes an accurate linear problem.The simulation results showthat the reconstruction accuracy of this algorithm is better than that of many traditional algorithms;furthermore,the reconstructed image artifacts are fewer,and the phase distribution boundary is clearer.This method can help determine the location and size of the caking and waste rock in the cross section of the pipeline more accurately and has great application prospects in the visualization of filling pipelines in mines.展开更多
Due to the widespread use of carbon fiber reinforced polymer/plastic(CFRP),the nondestructive structural health monitoring for CFRP is playing an increasingly essential role.As a nonrad iative,noninvasive and nondestr...Due to the widespread use of carbon fiber reinforced polymer/plastic(CFRP),the nondestructive structural health monitoring for CFRP is playing an increasingly essential role.As a nonrad iative,noninvasive and nondestructive detection technique,planar electrical capacitance tomography(PECT)electrodes array is employed in this paper to reconstruct the damage image according to the calculated dielectric constant changes.The shape and duty ratio of PECT electro-des are optimized according to the relations between sensitivity distribution and the dielectric constant of different anisotropic degrees.The sensitivity matrix of optimized PECT sensor is more uniform as the result shows,because the sensitiv-ity of insensitivity area can be increased by adding rotation of optimized electro-des.The reconstructed image qualities due to different PECT arrays and different damage locations are investigated at last.The simulation results indicate that:PECT can be used to detect the surface damage of CFRP;the sensitivity matrix of PECT for CFRP is highly relevant with the degree of anisotropic dielectric con-stant;the rotatable PECT sensor with rotation has better performance in unifor-mity of sensitivity;for different damage locations,the rotatable sensor with rotation has better image quality in most cases.展开更多
In the long distance transportation of slurry filled for mining filling,there exist complex variation rules of pressure and flow velocity,pipe distribution location and other influencing factors.Electrical capacitance...In the long distance transportation of slurry filled for mining filling,there exist complex variation rules of pressure and flow velocity,pipe distribution location and other influencing factors.Electrical capacitance tomography(ECT)is a technique for visualizing two-phase flow in a pipe or closed container.In this paper,a visual detection method was proposed by image reconstruction of core,laminar,bubble and annular flow based on ECT technology,which reflects distribution of slurry in deep filling pipeline and measures the degree of blockage.There is an error between the measured and the real two-phase flow distribution due to two factors,which are immature image reconstruction algorithm of ECT and difference of flow patterns leading to degrees of error.In this paper,convolutional neural networks(CNN)is used to recognize flow patterns,and then the optimal image is calculated by the improved particle swarm optimization(PSO)algorithm with weights using simulated annealing strategy,and the fitness function is improved based on the results of the shallow neural network.Finally,the reconstructed binary image is further processed to obtain the position,size and direction of the blocked pipe.The realization of this method provides technical support for pipeline detection technology.展开更多
Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is ...Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is first application of the method to visualization of water flow in soil.We describe the principles behind the method,and then demonstrate its use with a simple laboratory infiltration experiment.32 ECVT sensors were installed on the sides of an empty PVC column.Water was poured into the column at a constant rate,and ECVT data were collected every second.The column was then packed with dry sand and again supplied with water at a constant rate with data collected every second.Data were analyzed to give bulk average water contents,which proved consistent with the water supply rates.Data were also analyzed to give 3D images(216 voxels) allowing visualization of the water distribution during the experiments.Result of this work shows that water infiltration into the soil,wall flow,progress of the unstable wetting front and the final water distribution are clearly visible.展开更多
We describe a new two phase flow electrical capacitance tomography algorithm of image reconstruction which is based on 12 electrode capacitance transducers. According to the result of computer simulation, this algor...We describe a new two phase flow electrical capacitance tomography algorithm of image reconstruction which is based on 12 electrode capacitance transducers. According to the result of computer simulation, this algorithm is able to greatly increase the imaging fidelity without decreasing the imaging velocity.展开更多
Electrical capacitance tomography technique reconstructs dielectric constant distribution in an object by measuring the capacitances between the eletrode pairs which are mounted around this object. Because of the limi...Electrical capacitance tomography technique reconstructs dielectric constant distribution in an object by measuring the capacitances between the eletrode pairs which are mounted around this object. Because of the limitation of measurement condition, the measured data are imcomplet. This paper describes a multiresolution reconstructive algorithm which is based on network theory for electrical capacitance tomography technique. The dielectric constant distribution of flow of two components in a pipeline is reconstructed. The algorithm is as follows: Firstly, construct a rough, first level system model, and assume the dielectric constant distribution of the region to be reconstructed. After iteration, the dielectic constant of each unit can be reconstructed. Secondly, construct a finer, second level the system model and determine the initial dielectric constant of each unit in the region to be reconstructed according to related information between two levels. After iteration, the image of the pipeline's cross section can be reconstructed. The results of simulated experiments about different kinds of medium distributions show that this algorithm is effective and can converge.展开更多
Mesoporous polyethylene glycol-resorcinol and formaldehyde(PEG-RF) carbon xerogels were prepared by a new polymer blend method in which PEG-RF mixed organic xerogels were synthesized by blending thermally unstable p...Mesoporous polyethylene glycol-resorcinol and formaldehyde(PEG-RF) carbon xerogels were prepared by a new polymer blend method in which PEG-RF mixed organic xerogels were synthesized by blending thermally unstable polyethylene glycol with organic monomers, resorcinol and formaldehyde and then subjected to pyrolization at 1 000 ℃. The influences of mass ratio of PEG to the theoretical yield of RF xerogel, m(PEG)/m(RF) and the (relative) molecular mass of PEG on the pore structure and electric double layer capacitance(EDLC) performance of PEG-RF carbon xerogels were investigated. The results show that PEG under different conditions leads to the difference of phase separation structure of the polymer blend and thus the change of pore structure of PEG-RF carbon xerogels. Specific surface area and capacity of PEG-RF carbon xerogels in 30% H2SO4 solution can reach (755 m2/g) and 150 F/g, respectively. Their surface can be fully utilized to form electric double layer. However, the pore structure differences of PEG-RF carbon xerogels result in their different EDLC performances. The distributed capacitance effect increases with decreasing the pore size of PEG-RF carbon xerogels.展开更多
Electrical Capacitance Tomography (ECT) determines the dielectric permittivity of the interior object depending on the measurements of exterior capacitance. Generally, the electrodes are placed outside the PVC cylinde...Electrical Capacitance Tomography (ECT) determines the dielectric permittivity of the interior object depending on the measurements of exterior capacitance. Generally, the electrodes are placed outside the PVC cylinder where the medium to be imaged is present;but in ECT using inter-electrode capacitance measurements can be achieved by placing inside of the dielectric medium. In the proposed ECT system, the ECT sensor is modeled using ANSYS software and the model is implemented in real ECT system. For each step of measurement, a stable AC signal is applied to a pair of electrodes that form a capacitor. The novel system is to measure the capacitance range variation in picofarad and the corresponding voltage ranges from 1 volt to 4 volts. The switching speed of all combinational electrodes is implemented using embedded system to achieve higher speed performance of AC ECT system which eliminates the drift and stray capacitance error. This is yielding the original image of unknown multiphase medium inside the electrodes using Lab VIEW. This paper investigates several advantages such as improved overall system performance;simple structure, avoids stray capacitance effect, reduces the drift problem and achieves high signal to noise ratio.展开更多
Supercapacitors formed from porous carbon and graphene-oxide(GO)materials are usually dominated by either electric double-layer capacitance,pseudo-capacitance,or both.Due to these combined features,reduced GO material...Supercapacitors formed from porous carbon and graphene-oxide(GO)materials are usually dominated by either electric double-layer capacitance,pseudo-capacitance,or both.Due to these combined features,reduced GO materials have been shown to offer superior capacitance over typical nanoporous carbon materials;however,there is a significant variation in reported values,ranging between 25 and 350 F g^(−1).This undermines the structure(e.g.,oxygen functionality and/or surface area)-performance relationships for optimization of cost and scalable factors.This work demonstrates important structure-controlled charge storage relationships.For this,a series of exfoliated graphene(EG)derivatives are produced via thermal-shock exfoliation of GO precursors and following controlled graphitization of EG(GEG)generates materials with varied amounts of porosity,redox-active oxygen groups and graphitic components.Experimental results show significantly varied capacitance values between 30 and 250 F g^(−1)at 1.0 A g^(−1)in GEG structures;this suggests that for a given specific surface area the redox-active and hydrophilic oxygen content can boost the capacitance to 250–300%higher compared to typical mesoporous carbon materials.GEGs with identical oxygen functionality show a surface area governed capacitance.This allows to establish direct structure-performance relationships between 1)redox-active oxygen functional concentration and capacitance and 2)surface area and capacitance.展开更多
[Purpose] Capacitive and resistive electric transfer (CRET) is becoming prevalent in sports settings. CRET is effective for improving pain and healing injured tissue;however, its influence on muscle function and morph...[Purpose] Capacitive and resistive electric transfer (CRET) is becoming prevalent in sports settings. CRET is effective for improving pain and healing injured tissue;however, its influence on muscle function and morphology is still unclear. This study confirmed the immediate effects of CRET on the duration of muscular stiffness and range of motion (ROM). [Method] This study describes the protocol for a single-arm trial with the non-blinding of participants and researchers. Twenty-four healthy men participated in the study. They received CRET therapy for their low back areas. The muscular stiffness of the multifidus muscle (superficial and deep) and the ROM using the active straight leg raise (ASLR) test were measured pre-intervention, post-intervention (immediately), and 15 and 30 min post-intervention. We compared these parameters using a one-way analysis of variance and Dunnett’s test (multiple comparison tests for subtests). [Results] The muscular stiffness of the superficial and deep multifidus muscles was significantly decreased, and the ASLR test showed a significant increase compared with the test performed pre-intervention. In addition, these effects persisted for 30 min. [Conclusion] Warm-up is vital for improving muscular stiffness and increasing the ROM. CRET is a useful device for achieving these aims, particularly as a passive warm-up method in sports settings.展开更多
A cryogenic visible calibration and image evaluation facility(VCCIEF) was constructed to assess the effectiveness of electrical capacitance tomography systems in cryogenic conditions,known as Cryo-ECT.This facility wa...A cryogenic visible calibration and image evaluation facility(VCCIEF) was constructed to assess the effectiveness of electrical capacitance tomography systems in cryogenic conditions,known as Cryo-ECT.This facility was utilized to conduct dynamic,real-time imaging trials with liquid nitrogen(LN2).The actual flow patterns were captured using a camera and contrasted with the imaging outcomes.The capacitance data collected from these experiments were subsequently processed using three distinct methods:linear back projection,Landweber iteration,a fully connected deep neural network,and a convolutional neural network.This allowed for a comparative analysis of the performance of these algorithms in practical scenarios.The findings from the LN2 experiments demonstrated that the Cryo-ECT system,when integrated with the VCCIEF,was capable of successfully executing calibration,generating flow patterns,and performing imaging tasks.The system provided observable,clear,and precise phase distributions of the liquid nitrogen-vaporous nitrogenflow within the pipeline.展开更多
The complex dense-phase pneumatic conveying of pulverized coal process was studied using an electrical capacitance tomography(ECT) signal that represented the motion characteristics of gas-solid two-phase flow. The fl...The complex dense-phase pneumatic conveying of pulverized coal process was studied using an electrical capacitance tomography(ECT) signal that represented the motion characteristics of gas-solid two-phase flow. The fluctuation characteristics of conveying process signals are inseparable from the flow pattern. The denoised ECT signal and noise signal were obtained by db2 wavelet analysis. It was found that all noise signals were white Gaussian noise. Based on the assumption of the equal probability distribution of pulverized coal concentration, this paper proved that the time series distribution of pulverized coal concentration in the pipeline should obey the normal distribution. Furthermore, through the analysis of the distribution characteristics of the power spectral density function of denoised ECT signals of four flow patterns, they were α-dimensional fractal Brownian motion(fBm) signals, and the parameter α was estimated by the detrended fluctuation analysis. Based on the fBm characteristics of denoised ECT signals and white Gaussian noise, this paper proposed a method for calculating the pulverized coal concentration in the dense-phase pneumatic conveying. In addition to the method of concentration estimation with the significance of engineering guidance, this research can help people to further understand essential characteristics of ECT signals in the dense-phase pneumatic conveying.展开更多
The heat capacity and the electric capacitance of the black p-branes(BPB) are generally defined,then they are calculated for some special processes.It is found that the Ruppeiner thermodynamic geometry of BPB is flat....The heat capacity and the electric capacitance of the black p-branes(BPB) are generally defined,then they are calculated for some special processes.It is found that the Ruppeiner thermodynamic geometry of BPB is flat.Finally,we give some discussions for the flatness of the Ruppeiner thermodynamic geometry of BPB and some black holes.展开更多
基金National Key Research and Development Program of China(2021YFA1501302)the National Natural Science Foundation of China(22121004,22122808)+1 种基金the Haihe Laboratory of Sustainable Chemical Transformations and the Program of Introducing Talents of Discipline to Universities(BP0618007)for financial supportsupported by the XPLORER PRIZE.
文摘Noise is inevitable in electrical capacitance tomography(ECT)measurements.This paper describes the influence of noise on ECT performance for measuring gas-solids fluidized bed characteristics.The noise distribution is approximated by the Gaussian distribution and added to experimental capacitance data with various intensities.The equivalent signal strength(Ф)that equals the signal-to-noise ratio of packed beds is used to evaluate noise levels.Results show that the Pearson correlation coefficient,which indicates the similarity of solids fraction distributions over pixels,increases with Ф,and reconstructed images are more deteriorated at lower Ф.Nevertheless,relative errors for average solids fraction and bubble size in each frame are less sensitive to noise,attributed to noise compromise caused by the process of pixel values.These findings provide useful guidance for assessing the accuracy of ECT measurements of multiphase flows.
基金Supported by the National Natural Science Foundation of China (60672151, 60532020).
文摘Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computational models. Online measurements can be used for active control. Electrical capacitance tomography (ECT) is a unique measuring technique with great potential in multiphase flow measurement. Experimental studies are carried out on a solid concentration measurement in a cyclone separator dipleg, using ECT. In this experiment eight electrodes are selected for the ECT sensor that is placed on the straight tube of the dipleg. The fluctuating characteristics according to the screw feeder and the effect of the airflow rate from the top of the cyclone are analyzed. The feasibility andreliability of the method are verified by the experimental results.
基金the National High Technology Research and Development Program of China (863 Program) (No. 2002AA616050).
文摘To measure the void fraction online in oil-gas pipeline, an improved electrical capacitance tomography (ECT) system has been designed. The capacitance sensor with new structure has twelve internal electrodes and overcomes the influence of the pipe wall. The data collection system is improved by using high performance IC (integrated circuit). Static tests of bubble flow, stratified flow and annular flow regime are carried out. Measurements are taken on bubble flow, stratified flow and slug flow. Results show that the new ECT system performs well on void fraction measurement of bubble flow and stratified flow, but the error of measurement for slug flow is more than 10%.
基金Supported by the National Natural Science Foundation of China(61203021)the Key Science and Technology Program of Liaoning Province(2011216011)+1 种基金the Natural Science Foundation of Liaoning Province(2013020024)the Program for Liaoning Excellent Talents in Universities(LJQ2015061)
文摘Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed and nonlinear inverse problem of ECT image reconstruction,a new ECT image reconstruction method based on fast linearized alternating direction method of multipliers(FLADMM)is proposed in this paper.On the basis of theoretical analysis of compressed sensing(CS),the data acquisition of ECT is regarded as a linear measurement process of permittivity distribution signal of pipe section.A new measurement matrix is designed and L1 regularization method is used to convert ECT inverse problem to a convex relaxation problem which contains prior knowledge.A new fast alternating direction method of multipliers which contained linearized idea is employed to minimize the objective function.Simulation data and experimental results indicate that compared with other methods,the quality and speed of reconstructed images are markedly improved.Also,the dynamic experimental results indicate that the proposed algorithm can ful fill the real-time requirement of ECT systems in the application.
基金Supported by the National Natural Science Foundation of China (50806005,50736002,61072005)
文摘This study was conducted to investigate the characteristics of meso-scale combustion.The technique of electrical capacitance tomography(ECT) was used to locate flame position and monitor the effect corresponding to varied air/fuel ratio in a meso-scale combustor.Combustion phenomena including igniting,quenching and unsteady combustion have been visualized using ECT.The method of metallization protecting ECT sensor from high temperature damage and the novel calibration method adapted to ECT monitoring of unknown permittivity flame have been shown to be successful.At the same time,electrical nature of combustion and dielectric characteristics of hy-drocarbon flame were studied.The relationship between flame permittivity and state parameters of combustion gas was demonstrated preliminarily.
基金Project (No. 2001AA13210) supported by the Hi-Tech Research andDevelopment Program (863) of China
文摘A new voidage measurement method based on electrical capacitance tomography (ECT) technique, Genetic Algo- rithm (GA) and Partial Least Square (PLS) method was proposed. The voidage measurement model, linear capacitance combi- nation, was developed to measure on-line voidage. GA and PLS method were used to determine the coefficients of the voidage measurement model. GA was used to explore the optimal capacitance combination which gave significant contribution to the voidage measurement. PLS method was applied to determine the weight coefficient of the contribution of each capacitance to the voidage measurement. Flow pattern identification result was introduced to improve the voidage measurement accuracy. Experi- mental results showed that the proposed voidage measurement method is effective and that the measurement accuracy is satis- factory.
基金Supported by the National Natural Science Foundation of China (50736002,50806005,51006106)the Program for Changjiang Scholars and Innovative Research Team in University (IRT0952)
文摘Identifying the flow patterns is vital for understanding the complicated physical mechanisms in multiphase flows.For this purpose,electrical capacitance tomography(ECT) technique is considered as a promising visualization method for the flow pattern identification,in which image reconstruction algorithms play an important role.In this paper,a generalized dynamic reconstruction model,which integrates ECT measurement information and physical evolution information of the objects of interest,was presented.A generalized objective functional that simultaneously considers the spatial constraints,temporal constraints and dynamic evolution information of the objects of interest was proposed.Numerical simulations and experiments were implemented to evaluate the feasibility and efficiency of the proposed algorithm.For the cases considered in this paper,the proposed algorithm can well reconstruct the flow patterns,and the quality of the reconstructed images is improved,which indicates that the proposed algorithm is competent to reconstruct the flow patterns in the visualization of multiphase flows.
基金This research was supported by the National Natural Science Foundation of China(No.51704229)Outstanding Youth Science Fund of Xi’an University of Science and Technology(No.2018YQ2-01).
文摘During mine filling,the caking in the pipeline and the waste rock in the filling slurry may cause serious safety accidents such as pipe blocking or explosion.Therefore,the visualization of the innermine filling of the solid-liquid two-phase flow in the pipeline is important.This paper proposes a method based on capacitance tomography for the visualization of the solid-liquid distribution on the section of a filling pipe.A feedback network is used for electrical capacitance tomography reconstruction.This reconstruction method uses radial basis function neural network fitting to determine the relationship between the capacitance vector and medium distribution error.In the reconstruction process,the error in the linear back projection is removed;thus,the reconstruction problem becomes an accurate linear problem.The simulation results showthat the reconstruction accuracy of this algorithm is better than that of many traditional algorithms;furthermore,the reconstructed image artifacts are fewer,and the phase distribution boundary is clearer.This method can help determine the location and size of the caking and waste rock in the cross section of the pipeline more accurately and has great application prospects in the visualization of filling pipelines in mines.
基金This work is supported by the National Natural Science Foundation of China(Grant No.61871379).
文摘Due to the widespread use of carbon fiber reinforced polymer/plastic(CFRP),the nondestructive structural health monitoring for CFRP is playing an increasingly essential role.As a nonrad iative,noninvasive and nondestructive detection technique,planar electrical capacitance tomography(PECT)electrodes array is employed in this paper to reconstruct the damage image according to the calculated dielectric constant changes.The shape and duty ratio of PECT electro-des are optimized according to the relations between sensitivity distribution and the dielectric constant of different anisotropic degrees.The sensitivity matrix of optimized PECT sensor is more uniform as the result shows,because the sensitiv-ity of insensitivity area can be increased by adding rotation of optimized electro-des.The reconstructed image qualities due to different PECT arrays and different damage locations are investigated at last.The simulation results indicate that:PECT can be used to detect the surface damage of CFRP;the sensitivity matrix of PECT for CFRP is highly relevant with the degree of anisotropic dielectric con-stant;the rotatable PECT sensor with rotation has better performance in unifor-mity of sensitivity;for different damage locations,the rotatable sensor with rotation has better image quality in most cases.
基金Project(51704229)supported by the National Natural Science Foundation of ChinaProject(2018YQ2-01)supported by the Outstanding Youth Science Fund of Xi’an University of Science and Technology,China。
文摘In the long distance transportation of slurry filled for mining filling,there exist complex variation rules of pressure and flow velocity,pipe distribution location and other influencing factors.Electrical capacitance tomography(ECT)is a technique for visualizing two-phase flow in a pipe or closed container.In this paper,a visual detection method was proposed by image reconstruction of core,laminar,bubble and annular flow based on ECT technology,which reflects distribution of slurry in deep filling pipeline and measures the degree of blockage.There is an error between the measured and the real two-phase flow distribution due to two factors,which are immature image reconstruction algorithm of ECT and difference of flow patterns leading to degrees of error.In this paper,convolutional neural networks(CNN)is used to recognize flow patterns,and then the optimal image is calculated by the improved particle swarm optimization(PSO)algorithm with weights using simulated annealing strategy,and the fitness function is improved based on the results of the shallow neural network.Finally,the reconstructed binary image is further processed to obtain the position,size and direction of the blocked pipe.The realization of this method provides technical support for pipeline detection technology.
文摘Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is first application of the method to visualization of water flow in soil.We describe the principles behind the method,and then demonstrate its use with a simple laboratory infiltration experiment.32 ECVT sensors were installed on the sides of an empty PVC column.Water was poured into the column at a constant rate,and ECVT data were collected every second.The column was then packed with dry sand and again supplied with water at a constant rate with data collected every second.Data were analyzed to give bulk average water contents,which proved consistent with the water supply rates.Data were also analyzed to give 3D images(216 voxels) allowing visualization of the water distribution during the experiments.Result of this work shows that water infiltration into the soil,wall flow,progress of the unstable wetting front and the final water distribution are clearly visible.
文摘We describe a new two phase flow electrical capacitance tomography algorithm of image reconstruction which is based on 12 electrode capacitance transducers. According to the result of computer simulation, this algorithm is able to greatly increase the imaging fidelity without decreasing the imaging velocity.
文摘Electrical capacitance tomography technique reconstructs dielectric constant distribution in an object by measuring the capacitances between the eletrode pairs which are mounted around this object. Because of the limitation of measurement condition, the measured data are imcomplet. This paper describes a multiresolution reconstructive algorithm which is based on network theory for electrical capacitance tomography technique. The dielectric constant distribution of flow of two components in a pipeline is reconstructed. The algorithm is as follows: Firstly, construct a rough, first level system model, and assume the dielectric constant distribution of the region to be reconstructed. After iteration, the dielectic constant of each unit can be reconstructed. Secondly, construct a finer, second level the system model and determine the initial dielectric constant of each unit in the region to be reconstructed according to related information between two levels. After iteration, the image of the pipeline's cross section can be reconstructed. The results of simulated experiments about different kinds of medium distributions show that this algorithm is effective and can converge.
文摘Mesoporous polyethylene glycol-resorcinol and formaldehyde(PEG-RF) carbon xerogels were prepared by a new polymer blend method in which PEG-RF mixed organic xerogels were synthesized by blending thermally unstable polyethylene glycol with organic monomers, resorcinol and formaldehyde and then subjected to pyrolization at 1 000 ℃. The influences of mass ratio of PEG to the theoretical yield of RF xerogel, m(PEG)/m(RF) and the (relative) molecular mass of PEG on the pore structure and electric double layer capacitance(EDLC) performance of PEG-RF carbon xerogels were investigated. The results show that PEG under different conditions leads to the difference of phase separation structure of the polymer blend and thus the change of pore structure of PEG-RF carbon xerogels. Specific surface area and capacity of PEG-RF carbon xerogels in 30% H2SO4 solution can reach (755 m2/g) and 150 F/g, respectively. Their surface can be fully utilized to form electric double layer. However, the pore structure differences of PEG-RF carbon xerogels result in their different EDLC performances. The distributed capacitance effect increases with decreasing the pore size of PEG-RF carbon xerogels.
文摘Electrical Capacitance Tomography (ECT) determines the dielectric permittivity of the interior object depending on the measurements of exterior capacitance. Generally, the electrodes are placed outside the PVC cylinder where the medium to be imaged is present;but in ECT using inter-electrode capacitance measurements can be achieved by placing inside of the dielectric medium. In the proposed ECT system, the ECT sensor is modeled using ANSYS software and the model is implemented in real ECT system. For each step of measurement, a stable AC signal is applied to a pair of electrodes that form a capacitor. The novel system is to measure the capacitance range variation in picofarad and the corresponding voltage ranges from 1 volt to 4 volts. The switching speed of all combinational electrodes is implemented using embedded system to achieve higher speed performance of AC ECT system which eliminates the drift and stray capacitance error. This is yielding the original image of unknown multiphase medium inside the electrodes using Lab VIEW. This paper investigates several advantages such as improved overall system performance;simple structure, avoids stray capacitance effect, reduces the drift problem and achieves high signal to noise ratio.
基金supported by EPSRC(grants of EP/R511638/1,EP/S018204/2,EP/R023581/1,EP/W03395X/1,EP/W033321/1)the Science Specialty Program of Sichuan University(Grant.No.2020SCUNL210)+2 种基金The Royal Academy of Engineering is acknowledged for the financial support of Shearing(Ci ET171859)Brett(RCSRF2021/13/53)under the Research Chairs and Senior Research Fel owships schemethe National Physical Laboratory(NPL)and HORIBA MIRA for the support of his RAEng Research Chair
文摘Supercapacitors formed from porous carbon and graphene-oxide(GO)materials are usually dominated by either electric double-layer capacitance,pseudo-capacitance,or both.Due to these combined features,reduced GO materials have been shown to offer superior capacitance over typical nanoporous carbon materials;however,there is a significant variation in reported values,ranging between 25 and 350 F g^(−1).This undermines the structure(e.g.,oxygen functionality and/or surface area)-performance relationships for optimization of cost and scalable factors.This work demonstrates important structure-controlled charge storage relationships.For this,a series of exfoliated graphene(EG)derivatives are produced via thermal-shock exfoliation of GO precursors and following controlled graphitization of EG(GEG)generates materials with varied amounts of porosity,redox-active oxygen groups and graphitic components.Experimental results show significantly varied capacitance values between 30 and 250 F g^(−1)at 1.0 A g^(−1)in GEG structures;this suggests that for a given specific surface area the redox-active and hydrophilic oxygen content can boost the capacitance to 250–300%higher compared to typical mesoporous carbon materials.GEGs with identical oxygen functionality show a surface area governed capacitance.This allows to establish direct structure-performance relationships between 1)redox-active oxygen functional concentration and capacitance and 2)surface area and capacitance.
文摘[Purpose] Capacitive and resistive electric transfer (CRET) is becoming prevalent in sports settings. CRET is effective for improving pain and healing injured tissue;however, its influence on muscle function and morphology is still unclear. This study confirmed the immediate effects of CRET on the duration of muscular stiffness and range of motion (ROM). [Method] This study describes the protocol for a single-arm trial with the non-blinding of participants and researchers. Twenty-four healthy men participated in the study. They received CRET therapy for their low back areas. The muscular stiffness of the multifidus muscle (superficial and deep) and the ROM using the active straight leg raise (ASLR) test were measured pre-intervention, post-intervention (immediately), and 15 and 30 min post-intervention. We compared these parameters using a one-way analysis of variance and Dunnett’s test (multiple comparison tests for subtests). [Results] The muscular stiffness of the superficial and deep multifidus muscles was significantly decreased, and the ASLR test showed a significant increase compared with the test performed pre-intervention. In addition, these effects persisted for 30 min. [Conclusion] Warm-up is vital for improving muscular stiffness and increasing the ROM. CRET is a useful device for achieving these aims, particularly as a passive warm-up method in sports settings.
基金supported by the National Natural Science Foundation of China(51976177)the National Key Research and Development Program of China(2022YFB4000047)。
文摘A cryogenic visible calibration and image evaluation facility(VCCIEF) was constructed to assess the effectiveness of electrical capacitance tomography systems in cryogenic conditions,known as Cryo-ECT.This facility was utilized to conduct dynamic,real-time imaging trials with liquid nitrogen(LN2).The actual flow patterns were captured using a camera and contrasted with the imaging outcomes.The capacitance data collected from these experiments were subsequently processed using three distinct methods:linear back projection,Landweber iteration,a fully connected deep neural network,and a convolutional neural network.This allowed for a comparative analysis of the performance of these algorithms in practical scenarios.The findings from the LN2 experiments demonstrated that the Cryo-ECT system,when integrated with the VCCIEF,was capable of successfully executing calibration,generating flow patterns,and performing imaging tasks.The system provided observable,clear,and precise phase distributions of the liquid nitrogen-vaporous nitrogenflow within the pipeline.
基金funding from Shanghai Sailing Program (22YF1417600)Guangxi Science and Technology Major Program (AA23062019)
文摘The complex dense-phase pneumatic conveying of pulverized coal process was studied using an electrical capacitance tomography(ECT) signal that represented the motion characteristics of gas-solid two-phase flow. The fluctuation characteristics of conveying process signals are inseparable from the flow pattern. The denoised ECT signal and noise signal were obtained by db2 wavelet analysis. It was found that all noise signals were white Gaussian noise. Based on the assumption of the equal probability distribution of pulverized coal concentration, this paper proved that the time series distribution of pulverized coal concentration in the pipeline should obey the normal distribution. Furthermore, through the analysis of the distribution characteristics of the power spectral density function of denoised ECT signals of four flow patterns, they were α-dimensional fractal Brownian motion(fBm) signals, and the parameter α was estimated by the detrended fluctuation analysis. Based on the fBm characteristics of denoised ECT signals and white Gaussian noise, this paper proposed a method for calculating the pulverized coal concentration in the dense-phase pneumatic conveying. In addition to the method of concentration estimation with the significance of engineering guidance, this research can help people to further understand essential characteristics of ECT signals in the dense-phase pneumatic conveying.
基金Supported by National Natural Science Foundation of China under Grant No.201210782
文摘The heat capacity and the electric capacitance of the black p-branes(BPB) are generally defined,then they are calculated for some special processes.It is found that the Ruppeiner thermodynamic geometry of BPB is flat.Finally,we give some discussions for the flatness of the Ruppeiner thermodynamic geometry of BPB and some black holes.