期刊文献+
共找到96篇文章
< 1 2 5 >
每页显示 20 50 100
Doubly-Fed Pumped Storage Units Participation in Frequency Regulation Control Strategy for New Energy Power Systems Based on Model Predictive Control 被引量:2
1
作者 Yuanxiang Luo Linshu Cai Nan Zhang 《Energy Engineering》 2025年第2期765-783,共19页
Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluct... Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluctuation caused by new energy units,this paper proposes a new energy power system frequency regulation strategy with multiple units including the doubly-fed pumped storage unit(DFPSU).Firstly,based on the model predictive control(MPC)theory,the state space equations are established by considering the operating characteristics of the units and the dynamic behavior of the system;secondly,the proportional-differential control link is introduced to minimize the frequency deviation to further optimize the frequency modulation(FM)output of the DFPSU and inhibit the rapid fluctuation of the frequency;lastly,it is verified on theMatlab/Simulink simulation platform,and the results show that the model predictive control with proportional-differential control link can further release the FM potential of the DFPSU,increase the depth of its FM,effectively reduce the frequency deviation of the system and its rate of change,realize the optimization of the active output of the DFPSU and that of other units,and improve the frequency response capability of the system. 展开更多
关键词 doubly-fed pumped storage unit model predictive control proportional-differential control link frequency regulation
在线阅读 下载PDF
A Low Common-Mode Voltage Virtual Space Vector Modulation of Three-Level Converters for Doubly-Fed Variable-Speed Pumped Storage Systems
2
作者 Ziqiang Man Lei Zhao +6 位作者 Zheng Tao Shiming Cheng Wei Yan Gaoyue Zhong Yu Lu Wenming Zhang Li Zhang 《Energy Engineering》 2025年第9期3555-3572,共18页
With the rapid integration of renewable energy sources,modern power systems are increasingly challenged by heightened volatility and uncertainty.Doubly-fed variable-speed pumped storage units(DFVS-PSUs)have emerged as... With the rapid integration of renewable energy sources,modern power systems are increasingly challenged by heightened volatility and uncertainty.Doubly-fed variable-speed pumped storage units(DFVS-PSUs)have emerged as promising technologies for mitigating grid oscillations and enhancing system flexibility.However,the excitation converters in DFVS-PSUs are prone to significant issues such as elevated common-mode voltage(CMV)and neutral-point voltage(NPV)fluctuations,which can lead to electromagnetic interference and degrade transient performance.To address these challenges,an optimized virtual space vector pulse width modulation(OVSVPWM)strategy is proposed,aiming to suppress CMV and NPV simultaneously through coordinated multi-objective control.Specifically,a dynamic feedback mechanism is introduced to adjust the balancing factor of basic vectors in the synthesized virtual small vector in real-time,achieving autonomous balancing of the NPV.To address the excessive switching actions introduced by the OVSVPWM strategy,a phase duty ratio-based sequence reconstruction method is adopted,which reduces the total number of switching actions to half of the original.A zero-level buffering scheme is employed to reconstruct the single-phase voltage-level output sequence,achieving peak CMV suppression down to udc/6.Simulation results demonstrate that the proposed strategy significantly improves electromagnetic compatibility and operational stability while maintaining high power quality. 展开更多
关键词 doubly-fed variable-speed pumped storage units three-level excitation converter common-mode voltage neutral-point voltage virtual space voltage vector
在线阅读 下载PDF
Modeling and small-signal stability analysis of doubly-fed induction generator integrated system 被引量:4
3
作者 Tianming Gu Puyu Wang +3 位作者 Dingyuan Liu Ao Sun Dejian Yang Gangui Yan 《Global Energy Interconnection》 EI CSCD 2023年第4期438-449,共12页
Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the w... Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the wind generation penetration rate in power systems.In this study,we investigate a DFIG integrated system comprising four modules:(1)a wind turbine that considers the maximum power point tracking and pitch-angle control,(2)induction generator,(3)rotor/grid-side converter with the corresponding control strategy,and(4)AC power grid.The detailed small-signal modeling of the entire system is performed by linearizing the dynamic characteristic equation at the steady-state value.Furthermore,a dichotomy method is proposed based on the maximum eigenvalue real part function to obtain the critical value of the parameters.Root-locus analysis is employed to analyze the impact of changes in the phase-locked loop,short-circuit ratio,and blade inertia on the system stability.Lastly,the accuracy of the small-signal model and the real and imaginary parts of the calculated dominant poles in the theoretical analysis are verified using PSCAD/EMTDC. 展开更多
关键词 doubly-fed induction generator(DFIG) Maximum power point tracking DICHOTOMY Small-signal stability
在线阅读 下载PDF
Research on Control Strategy of Grid-connected Brushless Doubly-fed Wind Power System Based on Virtual Synchronous Generator Control 被引量:7
4
作者 Shuai Liang Shi Jin Long Shi 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期404-412,共9页
The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of ... The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of brushless doubly-fed reluctance generator(BDFRG) based on virtual synchronous generator(VSG) control is proposed to solve the problem in this paper.The output characteristics of BDFRG based on VSG are similar to a synchronous generator(SG),which can support the grid frequency and increase the system ‘inertia’.According to the mathematical model of BDFRG,the inner loop voltage source control of BDFRG is derived.In addition,the specific structure and parameter selection principle of outer loop VSG control are expounded.The voltage source control inner loop of BDFRG is combined with the VSG control outer loop to establish the overall architecture of BDFRG-VSG control strategy.Finally,the effectiveness and feasibility of the proposed strategy are verified in the simulation. 展开更多
关键词 Virtual synchronous generator Brushless doubly-fed relutance generator Grid support ability Voltage source control
在线阅读 下载PDF
Analytical Model and Topology Optimization of Doubly-fed Induction Generator 被引量:1
5
作者 Lu Sun Haoyu Kang +4 位作者 Jin Wang Zequan Li Jianjun Liu Yiming Ma Libing Zhou 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期162-169,共8页
As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and ... As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and accurate design optimization of DFIGs,this paper proposes a novel hybriddriven surrogate-assisted optimization method.It firstly establishes an accurate subdomain model of DFIGs to analytically predict performance indexes.Furthermore,taking the inexpensive analytical dataset produced by the subdomain model as the source domain and the expensive finite element analysis dataset as the target domain,a high-precision surrogate model is trained in a transfer learning way and used for the subsequent multi-objective optimization process.Based on this model,taking the total harmonic distortion of electromotive force,cogging torque,and iron loss as objectives,and the slot and inner/outer diameters as parameters for optimizing the topology,achieve a rapid and accurate electromagnetic design for DFIGs.Finally,experiments are carried out on a 3MW DFIG to validate the effectiveness of the proposed method. 展开更多
关键词 doubly-fed induction generators Accurate subdomain model Surrogate-assisted Transfer learning
在线阅读 下载PDF
Parameter Deviation Effect Study of the Power Generation Unit on a Doubly-Fed Induction Machine-based Shipboard Propulsion System 被引量:2
6
作者 Kai Ni Yihua Hu Chun Gan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期339-348,共10页
To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a syn... To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a synchronous generator(SG)is employed for power generation,and the accuracy of the parameters of power generation unit(PGU)plays an important role in SPS stable operation.In this paper,the PGU parameter deviations are studied to evaluate the effects on system performance.The models of salient-pole SG,type DC1A excitation system(EXS)and DFIM are illustrated first.Besides,the corresponding control scheme is explained.For the 16 important parameters of PGU,up to 40%of parameter deviations are applied to implement parameter sensitivity analysis.Then,simulation studies are carried out to evaluate the parameter deviation effects on system performance in detail.By defining three parameter deviation effect indicators(PDEIs),the effects on the PGU output variables,which are the terminal voltage and output active power,are studied.Moreover,the increasing rates of PDEIs with different degrees of parameter deviations for the key parameters are analyzed.Furthermore,the overall system performance is investigated for the two most influential PGU parameters.This paper provides some vital clues on SG and EXS parameter identification for DFIM-SPS. 展开更多
关键词 shipboard propulsion system partially power decoupled doubly-fed induction machine synchronous generator parameter deviation
在线阅读 下载PDF
Robust Position Observer for Sensorless Direct Voltage Control of Stand-Alone Ship Shaft Brushless Doubly-Fed Induction Generators 被引量:4
7
作者 Mohamed G.Hussien Yi Liu Wei Xu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期363-376,共14页
The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position obser... The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes. 展开更多
关键词 Brushless doubly-fed induction generator(BDFIG) direct voltage control(DVC) PW voltage-oriented vector control rotor position observer ship shaft applications.
在线阅读 下载PDF
A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support
8
作者 沈阳武 柯德平 +3 位作者 孙元章 Daniel Kirschen 王轶申 胡元朝 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期52-63,共12页
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt... A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. 展开更多
关键词 doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support
原文传递
Coordinated Rotor-Side Control Strategy for Doubly-FedWind Turbine under Symmetrical and Asymmetrical Grid Faults
9
作者 Quanchun Yan Chao Yuan +2 位作者 WenGu Yanan Liu Yiming Tang 《Energy Engineering》 EI 2023年第1期49-68,共20页
In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of ro... In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy. 展开更多
关键词 doubly-fed wind turbines symmetrical faults asymmetrical faults low voltage ride through rotor side control fault type detection
在线阅读 下载PDF
Suppression of thrust fluctuation of doubly-fed linear motor
10
作者 Ying WANG Kunlun ZHANG Mi ZHOU 《Journal of Modern Transportation》 2012年第2期103-107,共5页
Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linea... Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linear motor is used in the linear driving system of trains, neither an overhead line nor a third rail is needed. However, the doubly- fed motor will lead to more severe thrust fluctuation than the unilateral motors. In order to overcome this shortcoming, the thrust fluctuation of the doubly-fed motor should be analyzed. In this paper, an expression for motor thrust is derived. It points out that the slot effect caused by the slotted structure is the main reason for the increase of thrust fluctuation. The method of adopting unequal pole pitch and unequal slot numbers per pole per phase of stator and mover, is proposed to weaken the slot effect when designing the motor slot parameters. Three different motor models are simulated by ANSOFT. The proposed method results in a motor thrust fluctuation coefficient of 8.4%, compared to 49.4% for the conventional method. Therefore, the motor's thrust fluctuation is effectively suppressed by the proposed method. 展开更多
关键词 doubly-fed linear motor thrust fluctuation slot effect fractional slot
在线阅读 下载PDF
Performance Analysis of Nested-loop Secondary Linear Doubly-fed Machine Considering End Effects
11
作者 Yaping Zhang Jian Ge +4 位作者 Wei Xu Weiye Li Yinglu Luo Shihu Su Yunfeng He 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期298-305,共8页
Nested-loop secondary linear doubly-fed machine(NLS-LDFM) is a novel linear machine evolved from rotary brushless doubly-fed induction machine, which has a good application prospect in linear metro. In order to analyz... Nested-loop secondary linear doubly-fed machine(NLS-LDFM) is a novel linear machine evolved from rotary brushless doubly-fed induction machine, which has a good application prospect in linear metro. In order to analyze the performance of NLS-LDFM, the mechanism and action rules of end effects are investigated in this paper. Firstly, the mechanism of static and dynamic end effects is analyzed in aspect of direct coupling, winding asymmetry and transient secondary current. Furthermore, based on the winding theory for short primary linear machines, the machine parameters are established qualitatively considering pulsating magnetic field of NLS-LDFM. Finally, the NLS-LDFM performance analysis is supplemented by the finite element algorithm(FEA) simulation and experiments under different operating conditions. 展开更多
关键词 Linear doubly-fed machine(LDFM) End effect Parameter analysis Finite element algorithm(FEA)
在线阅读 下载PDF
Brushless Doubly-Fed Induction Machine as a Variable Frequency Transformer
12
作者 Ayman Abdel-Khalik Ahmed Elserougi +1 位作者 Ahmed Massoud Shehab Ahmed 《Journal of Energy and Power Engineering》 2013年第1期110-117,共8页
VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a bac... VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torque controls the power flow from stator to rotor and vice versa. The main disadvantage of this VFT is the slip rings and brushes required for the rotor circuit, especially in bulk power transmission. The BDFM (brushless doubly-fed machine) with nested cage rotor machine is proved to be a comparable alternative to conventional DFIM in many applications with the advantage that all windings being in the stator frame with fixed output terminals. In this paper, the BDFM is used as a BVFT (brushless variable frequency transformer). A prototype machine is designed and simulated to verify the system validity. 展开更多
关键词 Variable frequency transformer brushless doubly-fed machines AC machines induction machine.
在线阅读 下载PDF
Step-Loading Characteristics of Gas Engine Cogeneration System Using Doubly-Fed Induction Generator in Stand-Alone Operation
13
作者 Tetsuji Daido Yushi Miura +1 位作者 Toshifumi Ise Yuki Sato 《Journal of Energy and Power Engineering》 2014年第3期530-542,共13页
Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supp... Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine eogeneration system. In the case of conventional constant speed of synchronous generator, the amount of the allowed step load is limited to around 30% of the rated power. On the other hand, DFIG is expected to increase the amount of step load during the stand-alone operation. In this paper, it has been demonstrated that an increase in the gas engine speed resulted in an increase in the maximum amount of step load using experimental equipment with a real gas engine. It has been concluded that the proposed system can improve the performance of an emergency power supply at step-loading. 展开更多
关键词 Step load change doubly-fed induction generator gas engine cogeneration system stand-alone operation.
在线阅读 下载PDF
Converters’Loading Balance and Stability Verification for Doubly-fed Induction Generators
14
作者 Shenghu Li 《CSEE Journal of Power and Energy Systems》 2025年第3期1131-1140,共10页
Back-to-back converters are the main components of a doubly-fed induction generator(DFIG).If the loadings of the rotor-side converter(RSC)and the grid-side converter(GSC)are balanced,the capacity and the cost of the D... Back-to-back converters are the main components of a doubly-fed induction generator(DFIG).If the loadings of the rotor-side converter(RSC)and the grid-side converter(GSC)are balanced,the capacity and the cost of the DFIG will be reduced.This paper balances the converters'loadings by adjusting reactive power of the GSC(Q_(g*)).The steady-state constraints of the DFIG are solved to quantify the imbalance degree.A sensitivity model of the unbalanced loading with respect to Q_(g*)is proposed to balance the loadings.To verify if loading adjustment reduces the stability of the DFIG,the eigen–sensitivity models,with respect to Q_(g*)and stator voltage,are newly proposed with the power flow Jacobian matrix.Numerical results verify the accuracy and efficiency of the proposed model.The loadings of the converters are balanced with a few adjustments.Loading balance has little negative impact on the stability of the DFIG. 展开更多
关键词 CONVERTER doubly-fed induction generator eigen-sensitivity loading balance sensitivity STABILITY
原文传递
Enhancement of Frequency Regulation in AC-Excited Adjustable-Speed Pumped Storage Units during Pumping Operations
15
作者 Shuxin Tan Wei Yan +7 位作者 Lei Zhao Xianglin Zhang Ziqiang Man Yu Lu Teng Liu Gaoyue Zhong Weiqun Liu Linjun Shi 《Energy Engineering》 2025年第12期5175-5197,共23页
The integration of large-scale renewable energy introduces frequency instability challenges due to inherent intermittency.While doubly-fed pumped storage units(DFPSUs)offer frequency regulation potential in pumping mo... The integration of large-scale renewable energy introduces frequency instability challenges due to inherent intermittency.While doubly-fed pumped storage units(DFPSUs)offer frequency regulation potential in pumping mode,conventional strategies fail to address hydraulic-mechanical coupling dynamics and operational constraints,limiting their effectiveness.This paper presents an innovative primary frequency control strategy for double-fed pumped storage units(DFPSUs)operating in pumpingmode,integrating an adaptive parameter calculation method.This method is constrained by operational speed and power limits,addressing key performance factors.A dynamic model that incorporates the reversible pump-turbine characteristics is developed to translate frequency deviations into coordinated adjustments in speed and power during pumping operations.The research thoroughly analyzes the influence of control parameters on the frequency response dynamics.Additionally,the paper introduces a deep reinforcement learning(DRL)-based optimization framework,which enables real-time tuning of control parameters in response to changing rotor speed and frequency states.This method strategicallymanages the utilization of kinetic energy while ensuring compliance with operational safety constraints.The effectiveness of the proposed strategy is validated through simulation studies conducted on a four-machine,two-area DFPSU system.These studies demonstrate the strategy’s potential for improving frequency regulation performance under a variety of operating conditions,highlighting its effectiveness in optimizing energy storage and frequency control in power grids. 展开更多
关键词 doubly-fed pumped storage unit primary frequency control adaptive control variable coefficient deep reinforcement learning smart grid
在线阅读 下载PDF
大型风电场中不同位置的风机对次同步谐振特性影响程度的比较分析 被引量:45
16
作者 董晓亮 谢小荣 +1 位作者 李江 韩英铎 《中国电机工程学报》 EI CSCD 北大核心 2015年第20期5173-5180,共8页
针对双馈风机串补系统的次同步谐振问题,现有文献大都将整个风电场等效为单台风机进行研究,而忽略不同位置风机的风速、输出功率及其间线电缆参数对系统次同步特性的影响。该文将整个风电场划分为两个子风电场,分别等效为一台风机,建立... 针对双馈风机串补系统的次同步谐振问题,现有文献大都将整个风电场等效为单台风机进行研究,而忽略不同位置风机的风速、输出功率及其间线电缆参数对系统次同步特性的影响。该文将整个风电场划分为两个子风电场,分别等效为一台风机,建立两机串补系统模型,然后分别改变每台风机的转速、输出功率和电缆参数,比较对整个系统次同步特性的影响程度。结果表明:在同样风速条件下,不同位置的风机,对系统的次同步特性影响程度不同,离汇流母线近端的风机对系统稳定性的影响大于远端的风机。当整个风电场的输出功率给定,两子风电场输出容量配置比例不同,系统表现出的次同步特性不同,远端风电场输出功率越高系统稳定性越好。风机与汇流变母线之间的输电线路阻抗越大,系统的稳定性越强。 展开更多
关键词 多风电场 双馈风机 串补系统 次同步谐振 影响因素
原文传递
矩阵变换器励磁的双馈型发电机软并网控制 被引量:13
17
作者 李辉 阳春华 +1 位作者 邓文浪 马学亮 《中国电机工程学报》 EI CSCD 北大核心 2010年第15期75-79,共5页
双馈型风力发电机并网时,将不可避免对电网产生冲击电流,过大的冲击电流不仅会缩短电机的使用寿命,增加电网电压波动,甚至可能会造成并网的失败。采用矩阵变换器作为交流励磁系统,把矩阵变换器等效为虚拟整流器和虚拟逆变器,直接将电网... 双馈型风力发电机并网时,将不可避免对电网产生冲击电流,过大的冲击电流不仅会缩短电机的使用寿命,增加电网电压波动,甚至可能会造成并网的失败。采用矩阵变换器作为交流励磁系统,把矩阵变换器等效为虚拟整流器和虚拟逆变器,直接将电网电压的幅值和相位作为给定值,定子电压作为反馈值,简化了复杂的解耦控制,实现对矩阵变换器虚拟逆变侧的电压幅值和相位控制,使双馈型风力发电机定子电压跟随电网电压,从而减少并网时的冲击电流,实现与电网软并网。实验结果表明,并网时冲击电流较小,验证了控制策略的可行性。 展开更多
关键词 矩阵变换器 双馈电机 交流励磁 并网控制
原文传递
12/3相双绕组感应发电机直流侧突然短路电流分析 被引量:14
18
作者 王东 马伟明 +3 位作者 刘德志 傅立军 肖飞 张波涛 《中国电机工程学报》 EI CSCD 北大核心 2005年第15期133-139,共7页
通过适当简化分析,表明12/3相双绕组感应发电机直流侧突然短路不需要考虑辅助励磁绕组,等效为单独的十二相功率绕组直流侧突然短路,据此导出了交直流侧短路电流表达式。在此基础上,针对大容量的感应发电机,给出了估算交、直流侧最大冲... 通过适当简化分析,表明12/3相双绕组感应发电机直流侧突然短路不需要考虑辅助励磁绕组,等效为单独的十二相功率绕组直流侧突然短路,据此导出了交直流侧短路电流表达式。在此基础上,针对大容量的感应发电机,给出了估算交、直流侧最大冲击电流的简化计算公式,并论证其最大电流的到达时刻小于交流周期的二分之一,且随负载的增加其最大电流的到达时刻有所提前的结论。通过实验和仿真对比验证了该文所得结果的正确性,为系统保护装置的设计提供了理论依据。 展开更多
关键词 12/3相双绕组感应发电机 突然短路 理论依据
在线阅读 下载PDF
含双馈感应发电机的电网多步长快速暂态仿真 被引量:7
19
作者 周野 吴政球 陈波 《中国电机工程学报》 EI CSCD 北大核心 2012年第16期115-121,共7页
为提高含双馈感应发电机(doubly-fed inductiongenerator,DFIG)的电网暂态仿真效率,提出一种多步长快速暂态仿真方法。该方法在系统积分步长不变的情况下,通过可变参数改变双馈感应发电机模型的积分步长。对双馈感应发电机模型在改变后... 为提高含双馈感应发电机(doubly-fed inductiongenerator,DFIG)的电网暂态仿真效率,提出一种多步长快速暂态仿真方法。该方法在系统积分步长不变的情况下,通过可变参数改变双馈感应发电机模型的积分步长。对双馈感应发电机模型在改变后的步长下进行数值计算,此过程无需求解电力系统网络方程,当双馈感应发电机模型的积分时间和系统积分时间同步时,双馈感应发电机模型与系统其他元件统一进行精确的数值计算。简单系统和经典电力系统的仿真计算结果表明,所提仿真方法计算速度快、精度高,是一种有效、实用的计算方法。 展开更多
关键词 电力系统 暂态 双馈感应发电机:多步长 数值 计算
原文传递
电网短路时双馈感应发电机转子电流的分析与计算 被引量:77
20
作者 熊小伏 欧阳金鑫 《中国电机工程学报》 EI CSCD 北大核心 2012年第28期114-121,11,共8页
双馈风电机组对机端电压跌落比较敏感,随着风电装机容量的不断增加,电网故障时双馈风电机组转子电流的准确分析与评估变得十分重要,关系着双馈风电机组低电压穿越的实现以及故障电气量的分析与计算。从电网短路时双馈感应发电机的暂态... 双馈风电机组对机端电压跌落比较敏感,随着风电装机容量的不断增加,电网故障时双馈风电机组转子电流的准确分析与评估变得十分重要,关系着双馈风电机组低电压穿越的实现以及故障电气量的分析与计算。从电网短路时双馈感应发电机的暂态过程出发,分析了双馈感应发电机定子动态过程以及变流器调控对转子电流的影响,采用空间矢量法和坐标变换方法推导了电网对称短路和不对称短路时转子电流的表达式,通过时域仿真和算例结果验证了表达式的正确性。所提出的表达式利用机端电压以及变流器控制参数即可计算得到电网短路时任意时刻的转子电流,具有清晰的物理意义以及较好的实用性。 展开更多
关键词 电网 短路电流 风力发电 故障分析 低电压穿 双馈感应发电机
原文传递
上一页 1 2 5 下一页 到第
使用帮助 返回顶部