期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
DISTRIBUTED OPTIMAL LOCAL DOUBLE LOOP NETWORK
1
作者 李腊元 《Acta Mathematica Scientia》 SCIE CSCD 1992年第3期248-259,共12页
A distibuted optimal local double loop(DOLDL) network is presented. Emphasis is laid on the topology and distributed routing algorithms for the DOLDL. On the basis of building an abstract model, a set of definitions a... A distibuted optimal local double loop(DOLDL) network is presented. Emphasis is laid on the topology and distributed routing algorithms for the DOLDL. On the basis of building an abstract model, a set of definitions and theorems are described and proved. An algorithm which can optimize the double loop networks is presented. The optimal values of the topologic parameters for the DOLDL have been obtained by the algorithm, and these numerical results are analyzed. The study shows that the bounds of the optimal diameter (d) and average hop distance (a) for this class of networks are [square-root 3N -2] less-than-or-equal-to d less-than-or-equal-to [square-root 3N+1] and (5N/9(N-1)) (square-root 3N-1.8) < a < (5N/9 (N-1)). (square-root 3N - 0.23), respectively (N is the number of nodes in the network. (3 less-than-or-equal-to N less-than-or-equal-to 10(4)). A class of the distributed routing algorithms for the DOLDL and the implementation procedure of an adaptive fault-tolerant algorithm are proposed. The correctness of the algorithm has been also verified by simulating. 展开更多
关键词 NODE DISTRIBUTED OPTIMAL LOCAL double LOOP NETWORK LINK
在线阅读 下载PDF
Optimal Bandgap of Double Perovskite La-Substituted Bi2FeCrO6 for Solar Cells:an ab initio GGA+U Study
2
作者 B.Merabet H.Alamri +4 位作者 M.Djermouni A.Zaoui S.Kacimi A.Boukortt M.Bejar 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第1期81-85,共5页
The ab initio generalized gradient approximation (GGA)+U study of multiferroic (La Bi )<sub>2</sub>FeCrO<sub>6</sub> in pnma structure and ferri-magnetic order, including Hubbard corrections ( ... The ab initio generalized gradient approximation (GGA)+U study of multiferroic (La Bi )<sub>2</sub>FeCrO<sub>6</sub> in pnma structure and ferri-magnetic order, including Hubbard corrections ( eV) for transition metal/rare earth d-electrons with 20 atoms cell, shows optimum local magnetic moments of (Cr , Fe equal to (−2.56, 4.14) μB and an ideal spin-down band gap of 1.54 eV. Tuned-band gap La-substituted double oxide perovskites BFCO should exhibit enhanced visible-light absorption and carrier mobility, thus could be convenient light absorbers and then efficient alternatives to wide-gap chalcopyrite absorber-based solar cells failing to achieve highest power conversion efficiencies, and even compete with their metal-organic halide perovskites counterparts. 展开更多
关键词 Cr La Optimal Bandgap of double Perovskite La-Substituted Bi2FeCrO6 for Solar Cells:an ab initio GGA+U Study Fe Bi GGA
原文传递
Collaborative Fault Recovery and Network Reconstruction Method for Cyber-physical-systems Based on Double Layer Optimization 被引量:9
3
作者 Wanxing Sheng Keyan Liu +1 位作者 Zhao Li Xueshun Ye 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第1期380-392,共13页
For fault characteristics of cyber-physical-systems(CPS)based distribution network,a spatiotemporal incidence matrix to represent correlation of concurrent faults on cyberspace and physical space is proposed,and strat... For fault characteristics of cyber-physical-systems(CPS)based distribution network,a spatiotemporal incidence matrix to represent correlation of concurrent faults on cyberspace and physical space is proposed,and strategies of fault location,removal,and recovery of concurrent faults are analyzed in this paper.Considering the multiple objectives of minimum network loss,voltage deviation,and switching operation times,a collaborative power supply restoration model of a CPS-based distribution network with the strategy that restoration of the communication layer is prior to the physical layer is constructed using the Dijkstra’s dynamic routing algorithm and second-order cone relaxation distribution network reconfiguration method,to realize orderly recovery of a distribution network during CPS concurrent faults.Related investigations are made based on the DCPS-160 case,and the accuracy and effectiveness of the proposed model are also verified. 展开更多
关键词 Collaborative fault cyber-physical-systems distribution network double layer optimization
原文传递
上一页 1 下一页 到第