A distibuted optimal local double loop(DOLDL) network is presented. Emphasis is laid on the topology and distributed routing algorithms for the DOLDL. On the basis of building an abstract model, a set of definitions a...A distibuted optimal local double loop(DOLDL) network is presented. Emphasis is laid on the topology and distributed routing algorithms for the DOLDL. On the basis of building an abstract model, a set of definitions and theorems are described and proved. An algorithm which can optimize the double loop networks is presented. The optimal values of the topologic parameters for the DOLDL have been obtained by the algorithm, and these numerical results are analyzed. The study shows that the bounds of the optimal diameter (d) and average hop distance (a) for this class of networks are [square-root 3N -2] less-than-or-equal-to d less-than-or-equal-to [square-root 3N+1] and (5N/9(N-1)) (square-root 3N-1.8) < a < (5N/9 (N-1)). (square-root 3N - 0.23), respectively (N is the number of nodes in the network. (3 less-than-or-equal-to N less-than-or-equal-to 10(4)). A class of the distributed routing algorithms for the DOLDL and the implementation procedure of an adaptive fault-tolerant algorithm are proposed. The correctness of the algorithm has been also verified by simulating.展开更多
The ab initio generalized gradient approximation (GGA)+U study of multiferroic (La Bi )<sub>2</sub>FeCrO<sub>6</sub> in pnma structure and ferri-magnetic order, including Hubbard corrections ( ...The ab initio generalized gradient approximation (GGA)+U study of multiferroic (La Bi )<sub>2</sub>FeCrO<sub>6</sub> in pnma structure and ferri-magnetic order, including Hubbard corrections ( eV) for transition metal/rare earth d-electrons with 20 atoms cell, shows optimum local magnetic moments of (Cr , Fe equal to (−2.56, 4.14) μB and an ideal spin-down band gap of 1.54 eV. Tuned-band gap La-substituted double oxide perovskites BFCO should exhibit enhanced visible-light absorption and carrier mobility, thus could be convenient light absorbers and then efficient alternatives to wide-gap chalcopyrite absorber-based solar cells failing to achieve highest power conversion efficiencies, and even compete with their metal-organic halide perovskites counterparts.展开更多
For fault characteristics of cyber-physical-systems(CPS)based distribution network,a spatiotemporal incidence matrix to represent correlation of concurrent faults on cyberspace and physical space is proposed,and strat...For fault characteristics of cyber-physical-systems(CPS)based distribution network,a spatiotemporal incidence matrix to represent correlation of concurrent faults on cyberspace and physical space is proposed,and strategies of fault location,removal,and recovery of concurrent faults are analyzed in this paper.Considering the multiple objectives of minimum network loss,voltage deviation,and switching operation times,a collaborative power supply restoration model of a CPS-based distribution network with the strategy that restoration of the communication layer is prior to the physical layer is constructed using the Dijkstra’s dynamic routing algorithm and second-order cone relaxation distribution network reconfiguration method,to realize orderly recovery of a distribution network during CPS concurrent faults.Related investigations are made based on the DCPS-160 case,and the accuracy and effectiveness of the proposed model are also verified.展开更多
文摘A distibuted optimal local double loop(DOLDL) network is presented. Emphasis is laid on the topology and distributed routing algorithms for the DOLDL. On the basis of building an abstract model, a set of definitions and theorems are described and proved. An algorithm which can optimize the double loop networks is presented. The optimal values of the topologic parameters for the DOLDL have been obtained by the algorithm, and these numerical results are analyzed. The study shows that the bounds of the optimal diameter (d) and average hop distance (a) for this class of networks are [square-root 3N -2] less-than-or-equal-to d less-than-or-equal-to [square-root 3N+1] and (5N/9(N-1)) (square-root 3N-1.8) < a < (5N/9 (N-1)). (square-root 3N - 0.23), respectively (N is the number of nodes in the network. (3 less-than-or-equal-to N less-than-or-equal-to 10(4)). A class of the distributed routing algorithms for the DOLDL and the implementation procedure of an adaptive fault-tolerant algorithm are proposed. The correctness of the algorithm has been also verified by simulating.
文摘The ab initio generalized gradient approximation (GGA)+U study of multiferroic (La Bi )<sub>2</sub>FeCrO<sub>6</sub> in pnma structure and ferri-magnetic order, including Hubbard corrections ( eV) for transition metal/rare earth d-electrons with 20 atoms cell, shows optimum local magnetic moments of (Cr , Fe equal to (−2.56, 4.14) μB and an ideal spin-down band gap of 1.54 eV. Tuned-band gap La-substituted double oxide perovskites BFCO should exhibit enhanced visible-light absorption and carrier mobility, thus could be convenient light absorbers and then efficient alternatives to wide-gap chalcopyrite absorber-based solar cells failing to achieve highest power conversion efficiencies, and even compete with their metal-organic halide perovskites counterparts.
基金This work is supported by Funds for International Cooperation and Exchange of the National Natural Science Foundation of China(Grant No.52061635104,Sustainable urban power supply through intelligent control and enhanced restoration of AC/DC networks).
文摘For fault characteristics of cyber-physical-systems(CPS)based distribution network,a spatiotemporal incidence matrix to represent correlation of concurrent faults on cyberspace and physical space is proposed,and strategies of fault location,removal,and recovery of concurrent faults are analyzed in this paper.Considering the multiple objectives of minimum network loss,voltage deviation,and switching operation times,a collaborative power supply restoration model of a CPS-based distribution network with the strategy that restoration of the communication layer is prior to the physical layer is constructed using the Dijkstra’s dynamic routing algorithm and second-order cone relaxation distribution network reconfiguration method,to realize orderly recovery of a distribution network during CPS concurrent faults.Related investigations are made based on the DCPS-160 case,and the accuracy and effectiveness of the proposed model are also verified.