[Objective] The aim was to test the controlling effect of cleaning steriliza- tion system, material conveying system, and fermentation jar cooling system with equip- ments of fruit wine production line introduced in t...[Objective] The aim was to test the controlling effect of cleaning steriliza- tion system, material conveying system, and fermentation jar cooling system with equip- ments of fruit wine production line introduced in this study and its auto-control sys- tem field assembled and debugged. [Method] Based on controlling equipment and setting parameters on the configuration interface, the operation state of the control equipments could be real-time monitored and controlled with the help of configura- tion software. [Result] The result showed that the equipment system could reduce the temperature into 12 ℃ with the error of +0.5 ℃within 110 minutes when the fermentation temperature is set at 12 ℃ in real production. [Conclusion] The auto- control system of fruit wine production line was easy to be assembled and de- bugged to meet demands of different fruit wine productions.展开更多
This paper presents a debugging system for multi-pole array acoustic logging (MPAL) tools. The debugging system proposed in this study can debug the MPAL tool system, sub-system and local electronics. In the test eq...This paper presents a debugging system for multi-pole array acoustic logging (MPAL) tools. The debugging system proposed in this study can debug the MPAL tool system, sub-system and local electronics. In the test equipment, we have used principal and subordinate structures, and interconnected the host computer and the front-end machine via Ethernet. The front-end machine is based on the ARM7 (advanced reduced instruction set computing (RISC) machine) technique, the processor of which runs an embedded operating system, namely, uClinux OS. We have analyzed the system telecommunication, human-machine interface circuit, transmitter mandrel interface circuit, receiver mandrel interface circuit, and board-level test interface circuit. The software used in the system consists of the embedded front-computer software and the host application software. We have explained in detail the flow chart of the boot loader in the embedded front-computer software. The host application software is composed of four application subroutines, which match with the functional modules of the system hardware. A net communication program based on the server^client mode is implemented by means of socket programming and multi-thread programming. Test results indicate that the data transmission rate of the system is higher than 1 MB/s, which completely meets the current requirements of the data transmission rate between the tool system and the wireline telemetry device. Application of the debugging system, which includes multiple level test methods, shows that the proposed system can fully meet the test requirements of MPAL at various levels.展开更多
The electrical design of high-rise buildings usually involves many links, among which the low-voltage distribution system plays an irreplaceable role. From the current domestic development, high-rise buildings mainly ...The electrical design of high-rise buildings usually involves many links, among which the low-voltage distribution system plays an irreplaceable role. From the current domestic development, high-rise buildings mainly refer to buildings with more than 30 floors. At the same time, with the rise of the floor height, the complexity of the electrical system will increase significantly, which makes the electrical design face many difficulties. In the actual process of high-rise building electrical design, it is not only necessary to comprehensively control the reliability of the building power supply system, but also to ensure that the electrical devices can play an effective role. Therefore, in-depth study of low-voltage distribution system has practical significance. This paper analyzes the actual electrical design of high-rise buildings, discusses the stability and safety of the system, and explores how to better construct the electrical design scheme and apply it in practice, so as to lay a solid foundation for the construction of high-rise buildings.展开更多
Compressor is a large power supply, equipment installation and commissioning and equipment protection plays a very important role. On this basis, this paper introduces the installation of the control system of large c...Compressor is a large power supply, equipment installation and commissioning and equipment protection plays a very important role. On this basis, this paper introduces the installation of the control system of large compressor unit, analyzes the installation and commissioning of large compressor unit system, and comprehensively analyzes the application of commissioning technology in the installation of large compressor unit.展开更多
基金Supported by Fundamental Research Foundation of GXAAS(GNK2013YM02)~~
文摘[Objective] The aim was to test the controlling effect of cleaning steriliza- tion system, material conveying system, and fermentation jar cooling system with equip- ments of fruit wine production line introduced in this study and its auto-control sys- tem field assembled and debugged. [Method] Based on controlling equipment and setting parameters on the configuration interface, the operation state of the control equipments could be real-time monitored and controlled with the help of configura- tion software. [Result] The result showed that the equipment system could reduce the temperature into 12 ℃ with the error of +0.5 ℃within 110 minutes when the fermentation temperature is set at 12 ℃ in real production. [Conclusion] The auto- control system of fruit wine production line was easy to be assembled and de- bugged to meet demands of different fruit wine productions.
基金supported by National Science Foundation of China (61102102, 11134011, 11204380 and 11374371)Major National Science and Technology Projects (2011ZX05020-002)+2 种基金PetroChina Innovation Foundation (2014D-5006-0307)Science and Technology Project of CNPC (2014A-3912 and 2011B-4001)the Foundation of China University of Petroleum (KYJJ2012-05-07)
文摘This paper presents a debugging system for multi-pole array acoustic logging (MPAL) tools. The debugging system proposed in this study can debug the MPAL tool system, sub-system and local electronics. In the test equipment, we have used principal and subordinate structures, and interconnected the host computer and the front-end machine via Ethernet. The front-end machine is based on the ARM7 (advanced reduced instruction set computing (RISC) machine) technique, the processor of which runs an embedded operating system, namely, uClinux OS. We have analyzed the system telecommunication, human-machine interface circuit, transmitter mandrel interface circuit, receiver mandrel interface circuit, and board-level test interface circuit. The software used in the system consists of the embedded front-computer software and the host application software. We have explained in detail the flow chart of the boot loader in the embedded front-computer software. The host application software is composed of four application subroutines, which match with the functional modules of the system hardware. A net communication program based on the server^client mode is implemented by means of socket programming and multi-thread programming. Test results indicate that the data transmission rate of the system is higher than 1 MB/s, which completely meets the current requirements of the data transmission rate between the tool system and the wireline telemetry device. Application of the debugging system, which includes multiple level test methods, shows that the proposed system can fully meet the test requirements of MPAL at various levels.
文摘The electrical design of high-rise buildings usually involves many links, among which the low-voltage distribution system plays an irreplaceable role. From the current domestic development, high-rise buildings mainly refer to buildings with more than 30 floors. At the same time, with the rise of the floor height, the complexity of the electrical system will increase significantly, which makes the electrical design face many difficulties. In the actual process of high-rise building electrical design, it is not only necessary to comprehensively control the reliability of the building power supply system, but also to ensure that the electrical devices can play an effective role. Therefore, in-depth study of low-voltage distribution system has practical significance. This paper analyzes the actual electrical design of high-rise buildings, discusses the stability and safety of the system, and explores how to better construct the electrical design scheme and apply it in practice, so as to lay a solid foundation for the construction of high-rise buildings.
文摘Compressor is a large power supply, equipment installation and commissioning and equipment protection plays a very important role. On this basis, this paper introduces the installation of the control system of large compressor unit, analyzes the installation and commissioning of large compressor unit system, and comprehensively analyzes the application of commissioning technology in the installation of large compressor unit.