期刊文献+
共找到1,060篇文章
< 1 2 53 >
每页显示 20 50 100
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
1
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault Grounding protection Zero-sequence current ratio coefficient
在线阅读 下载PDF
High-Performance In0.23Ga0.77As Channel MOSFETs with High Current Ratio Ion/Ioff Grown on Semi-insulating GaAs Substrates by MOCVD
2
作者 孔祥挺 周旭亮 +4 位作者 李士颜 乔丽君 刘洪刚 王圩 潘教青 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第3期121-123,共3页
We demonstrate high-performance In0.23 Ga0.77 As channel metal-oxide-semiconductor field-effect transistors ( MOS- FETs) with high on-current to off-current (Ion/Ioff) ratio grown on semi-insulating GaAs wafers by... We demonstrate high-performance In0.23 Ga0.77 As channel metal-oxide-semiconductor field-effect transistors ( MOS- FETs) with high on-current to off-current (Ion/Ioff) ratio grown on semi-insulating GaAs wafers by metal-organic chemical vapor deposition (MOCVD). The 2μm channel-length devices exhibit a peak extrinsic transeonductance of 150 mS/mm and a drain current up to 500 mA/mm. The maximum effective mobility is 1680 cm2/Vs extracted by the split C-V method. Furthermore, the Ion/Ioff ratio is significantly improved from approximately 4.5 × 10^3 up to approximately 4.32 × 10^4 by controlling the etch thickness of In0.49Ga0.51P, The high drain current and high Ion/Ioff ratio of the In0.23Ga0.77As channel MOSFETs are achieved due to the high effective mobility and the low gate leakage current density. 展开更多
关键词 As Channel MOSFETs with High current ratio I MOSFET Ga Grown on Semi-insulating GaAs Substrates by MOCVD off
原文传递
Protection for HVDC Transmission Lines Based on Current Ratio of DC Filter and Smoothing Reactor
3
作者 Ningning Liu Yongli Li +3 位作者 Tao Li Song Li Jinghan He Xinzhou Dong 《CSEE Journal of Power and Energy Systems》 2025年第4期1625-1634,共10页
A new line protection for HVDC systems using the ratio of currents of a DC filter and smoothing reactor is presented.Characteristic analysis on a DC filter shows that it behaves like an inductor at a high frequency ba... A new line protection for HVDC systems using the ratio of currents of a DC filter and smoothing reactor is presented.Characteristic analysis on a DC filter shows that it behaves like an inductor at a high frequency band whose inductance is far less than the sum of smoothing reactor inductance plus converter equivalent inductance.Based on this characteristic,fault analysis shows that during high-frequency DC line faults(on either side),the DC filter current amplitude significantly exceeds that of the smoothing reactor,with a current ratio much greater than 1.Whereas for external faults,near faulty end,DC filter current amplitude is less than the one of a smoothing reactor and current ratio at this end is smaller than 1,while the current ratio at the distance faulty end is still far greater than 1.The effectiveness of the protection is verified by a large number of simulation experiments.It does not need synchronization of signals at both ends.In addition,it has high sensitivity for high-resistance faults,and is insensitive to the length of DC transmission line and power flow change. 展开更多
关键词 current ratio fault characteristic analysis highresistance fault HVDC system line protection
原文传递
Location of Asymmetric Ground Fault Using Virtual Injected Current Ratio and Two-stage Recovery Strategy in Distribution Networks 被引量:1
4
作者 Haiting Shan Luliang Zhang +1 位作者 Q.H.Wu Mengshi Li 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第1期151-161,共11页
Sparse measurements challenge fault location in distribution networks.This paper proposes a method for asymmetric ground fault location in distribution networks with limited measurements.A virtual injected current vec... Sparse measurements challenge fault location in distribution networks.This paper proposes a method for asymmetric ground fault location in distribution networks with limited measurements.A virtual injected current vector is formulated to estimate the fault line,which can be reconstructed from voltage sags measured at a few buses using compressive sensing(CS).The relationship between the virtual injected current ratio(VICR)and fault position is deduced from circuit analysis to pinpoint the fault.Furthermore,a two-stage recovery strategy is proposed for improving reconstruction accuracy of the current vector,where two different sensing matrixes are utilized to improve the incoherence.The proposed method is validated in IEEE 34 node test feeder.Simulation results show asymmetric ground fault type,resistance,fault position and access of distributed generators(DGs)do not significantly influence performance of our method.In addition,it works effectively under various scenarios of noisy measurement and line parameter error.Validations on 134 node test feeders prove the proposed method is also suitable for systems with more complex structure. 展开更多
关键词 Distribution networks fault location reconstruction accuracy two-stage recovery virtual injected current ratio
原文传递
Flexible UV detectors based on in-situ hydrogen doped amorphous Ga_(2)O_(3) with high photo-to-dark current ratio 被引量:1
5
作者 Yanxin Sui Huili Liang +3 位作者 Wenxing Huo Xiaozhi Zhan Tao Zhu Zengxia Mei 《Materials Futures》 2024年第1期181-189,共9页
Amorphous Ga_(2)O_(3)(a-Ga_(2)O_(3))has been attracting more and more attention due to its unique merits such as wide bandgap(∼4.9 eV),low growth temperature,large-scale uniformity,low cost and energy efficient,makin... Amorphous Ga_(2)O_(3)(a-Ga_(2)O_(3))has been attracting more and more attention due to its unique merits such as wide bandgap(∼4.9 eV),low growth temperature,large-scale uniformity,low cost and energy efficient,making it a powerful competitor in flexible deep ultraviolet(UV)photodetection.Although the responsivity of the ever-reported a-Ga_(2)O_(3)UV photodetectors(PDs)is usually in the level of hundreds of A/W,it is often accompanied by a large dark current due to the presence of abundant oxygen vacancy(VO)defects,which severely limits the possibility to detect weak signals and achieve versatile applications.In this work,the VO defects in a-Ga_(2)O_(3)thin films are successfully passivated by in-situ hydrogen doping during the magnetron sputtering process.As a result,the dark current of a-Ga_(2)O_(3)UV PD is remarkably suppressed to 5.17×10^(-11) A at a bias of 5 V.Importantly,the photocurrent of the corresponding device is still as high as 1.37×10^(-3)A,leading to a high photo-to-dark current ratio of 2.65×107 and the capability to detect the UV light with the intensity below 10 nW cm^(-2).Moreover,the H-doped a-Ga_(2)O_(3)thin films have also been deposited on polyethylene naphtholate substrates to construct flexible UV PDs,which exhibit no great degradation in bending states and fatigue tests.These results demonstrate that hydrogen doping can effectively improve the performance of a-Ga_(2)O_(3)UV PDs,further promoting its practical application in various areas. 展开更多
关键词 Ga_(2)O_(3) hydrogen doping ultraviolet photodetector photo-to-dark current ratio neutron reflection
在线阅读 下载PDF
High peak-to-valley current ratio In_(0.53)Ga_(0.47)As/AlAs resonant tunneling diode with a high doping emitter
6
作者 王伟 孙浩 +1 位作者 滕腾 孙晓玮 《Journal of Semiconductors》 EI CAS CSCD 2012年第12期23-26,共4页
An In0.53Ga0.47As/AlAs resonant tunneling diode (RTD) with a high doping emitter is designed and fabricated using air bridge technology. The RTD exhibits a high peak-to-valley current ratio (PVCR) of more than 40 ... An In0.53Ga0.47As/AlAs resonant tunneling diode (RTD) with a high doping emitter is designed and fabricated using air bridge technology. The RTD exhibits a high peak-to-valley current ratio (PVCR) of more than 40 at room temperature, with a peak current density of 24 kA/cm2. The extraction of device parameters from DC and microwave measurements is presented together with an RTD equivalent circuit. The high PVCR RTD with small intrinsic capacitance is favorable for microwave/THz applications. 展开更多
关键词 resonant tunneling diode I-V characteristics peak-to-valley current ratio equivalent circuit S-PARAMETERS
原文传递
Improving electrical performance and fringe effect in p-type SnO_(x)thin film transistors via Ta incorporation
7
作者 Yu Song Runtong Guo +6 位作者 Ruohao Hong Rui He Xuming Zou Benjamin Iñiguez Denis Flandre Lei Liao Guoli Li 《Journal of Semiconductors》 2025年第9期78-85,共8页
In this work,the incorporation of tantalum(Ta)into p-type metal-oxide(SnO_(x))semiconductor film is investigated to improve the electrical characteristics and suppress the fringe effect of thin film transistors(TFTs).... In this work,the incorporation of tantalum(Ta)into p-type metal-oxide(SnO_(x))semiconductor film is investigated to improve the electrical characteristics and suppress the fringe effect of thin film transistors(TFTs).The Ta-doped SnO_(x)(SnO_(x):Ta)film is deposited by radio-frequency(RF)magnetron sputtering with a Sn:Ta(3 at.%)target and thermally annealed at 270℃ for 30 min.Here,we observe that the SnO_(x):Ta film presents increased crystallinity,reduced defect density(3.25×10^(12)cm^(−2)·eV^(−1)),and widened bandgap(1.98 eV),in comparison with the undoped SnO_(x)film.As a result,the SnO_(x):Ta TFTs exhibit a lower off-state current(Ioff),an improved on/off current ratio(2.17×10^(4)),a remarkably decreased subthreshold swing(SS)by 41%,and enhanced device stability.Additionally,by introducing Ta dopants,the fringe effect as well as the impact of channel width-to-length ratio(W/L)on electrical performances of the p-type oxide TFTs can be effectively suppressed.These results shall contribute to further exploration and development of p-type SnO_(x)TFTs. 展开更多
关键词 tin monoxide p-type thin film transistors Ta doping fringe effect on/off current ratio
在线阅读 下载PDF
Relationship between the Current Account Balance Ratio and Salary Ratio in Japanese Municipal Hospitals
8
作者 Nozomu Mandai Mayumi Watanabe 《Health》 2019年第12期1591-1597,共7页
Background: While public municipal hospitals in Japan are supported by public financing and are less likely to fail than private hospitals, more than half are in financial deficit. Hospitals running at a deficit may h... Background: While public municipal hospitals in Japan are supported by public financing and are less likely to fail than private hospitals, more than half are in financial deficit. Hospitals running at a deficit may have poorer outcomes and less investment in maintenance of human or physical capital, as well as increased rates of patient adverse events. We sought to clarify the relationship between municipal hospital surpluses or deficits and salary expenditures. Methods: We extracted financial data for 253 general hospitals of 300 beds or more from financial statements for the 2013 fiscal year available in the Yearbook of Public Firms, Edition for Hospital. From these data, we calculated account balance ratios and compared the average value of the ratio of labor to the output (salary ratio) for each group using analysis of variance (ANOVA). Results: The salary ratios of hospitals in the surplus group were significantly lower than the salary ratios of hospitals in the deficit group (55.5% vs. 49.4%;p p = 0.342). In the surplus group, the average value of salary ratios was different among the three-bed count groups (mean salary ratio: 53.0% vs. 48.5% vs. 47.4%;ANOVA p = 0.012). In addition, there was a significant difference in mean value between the 300-bed group and ≥500 beds group (mean salary ratio: 53.0% vs. 47.4%;p = 0.002). Conclusion: This study suggests that maintaining a favorable salary ratio to the current account balance is a useful proxy of fiscal health, and interventions to improve the salary ratio may be effective in improving municipal hospital management. Furthermore, among well-managed municipal hospitals, larger hospital size may confer some advantage in purchasing power. 展开更多
关键词 HOSPITAL FINANCE SALARY ratio Public HOSPITAL current ACCOUNT Balance ratio
在线阅读 下载PDF
Effect of Distortion Ratio on Local Scour Under Tidal Currents and Waves
9
作者 窦希萍 董凤舞 《海洋工程:英文版》 EI 2004年第4期613-627,共15页
Five generalized physical models of different distortion ratios were built according to DOU Guo-ren's similarity theory of total sediment transport modeling for estuarine and coastal regions. Experiments on local ... Five generalized physical models of different distortion ratios were built according to DOU Guo-ren's similarity theory of total sediment transport modeling for estuarine and coastal regions. Experiments on local scour in front of groins were made under the actions of tidal currents and waves with clear and sediment entraining water. The scour depths under different dynamic actions are compared. The effect of the distortion ratio on the depth of scour hole is discussed. A relationship between scour depths for distorted and undistorted models is given. 展开更多
关键词 physical model distortion ratio tidal currents WAVES local scour
在线阅读 下载PDF
A DBRTD with a High PVCR and a Peak Current Density at Room Temperature
10
作者 易里成荣 谢常青 +2 位作者 王从舜 刘明 叶甜春 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2005年第10期1871-1874,共4页
AlAs/GaAs/In0.1Ga0.9As/GaAs/AlAs double-barrier resonant tunneling diodes (DBRTDs) grown on a semi-insulated GaAs substrate with molecular beam epitaxy is demonstrated. By sandwiching the In0.1 Ga0.9 As layer betwee... AlAs/GaAs/In0.1Ga0.9As/GaAs/AlAs double-barrier resonant tunneling diodes (DBRTDs) grown on a semi-insulated GaAs substrate with molecular beam epitaxy is demonstrated. By sandwiching the In0.1 Ga0.9 As layer between GaAs layers, potential wells beside the two sides of barrier are deepened, resulting in an increase of the peak-to-valley current ratio (PVCR) and a peak current density. A special shape of collector is designed in order to reduce contact resistance and non-uniformity of the current;as a result the total chrrent density in the device is increased. The use of thin barriers is also helpful for the improvement of the PVCR and the peak current density in DBRTDs. The devices exhibit a maximum PVCR of 13.98 and a peak current density of 89kA/cm^2 at room temperature. 展开更多
关键词 resonant tunneling diode peak-to-valley current ratio peak current density
在线阅读 下载PDF
Saturation Ion Current Densities in Inductively Coupled Hydrogen Plasma Produced by Large-Power Radio Frequency Generator
11
作者 WANG Songbai LEI Guangjiu +3 位作者 BI Zhenhua H. GHOMI YANG Size LIU Dongping 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第9期907-911,共5页
An experimental investigation of the saturation ion current densities (Jions) in hydrogen inductively coupled plasma (ICP) produced by a large-power (2-32 kW) radio frequency (RF) generator is reported, then s... An experimental investigation of the saturation ion current densities (Jions) in hydrogen inductively coupled plasma (ICP) produced by a large-power (2-32 kW) radio frequency (RF) generator is reported, then some reasonable explanations are given out. With the increase of RF power, the experimental results show three stages: in the first stage (2-14 kW), the electron temperature will rise with the increase of RF power in the ICP, thus, the Jions increases continually as the electron temperature rises in the ICP. In the second stage (14 20 kW), as some H- ions lead to the mutual neutralization (MN), the slope of Jio^s variation firstly decreases then increases. In the third stage (20-32 kW), both the electronic detachment (ED) and the associative detachment (AD) in the ICP result in the destruction of H- ions, therefore, the increased amplitude of the Jions in the third stage is weaker than the one in the first stage. In addition, with the equivalent transformer model, we successfully Explain that the Jions at different radial locations in ICP has the same rule. Finally, it is found that the Jions has nothing to do with the outer/inner puffing gas pressure ratio, which is attributed to the high-speed movement of hydrogen molecules. 展开更多
关键词 saturation ion current densities large-power RF generator outer/innerpuffing gas pressure ratio H- ion transformer model
在线阅读 下载PDF
Electrodeposition of Gold to Conformally Fill High-Aspect-Ratio Nanometric Silicon Grating Trenches: A Comparison of Pulsed and Direct Current Protocols 被引量:2
12
作者 Sami Znati Nicholas Chedid +3 位作者 Houxun Miao Lei Chen Eric E. Bennett Han Wen 《Journal of Surface Engineered Materials and Advanced Technology》 2015年第4期207-213,共7页
Filling high-aspect-ratio trenches with gold is a frequent requirement in the fabrication of X-ray optics as well as micro-electronic components and other fabrication processes. Conformal electrodeposition of gold in ... Filling high-aspect-ratio trenches with gold is a frequent requirement in the fabrication of X-ray optics as well as micro-electronic components and other fabrication processes. Conformal electrodeposition of gold in sub-micron-width silicon trenches with an aspect ratio greater than 35 over a grating area of several square centimeters is challenging and has not been described in the literature previously. A comparison of pulsed plating and constant current plating led to a gold electroplating protocol that reliably filled trenches for such structures. 展开更多
关键词 PULSED ELECTROPLATING Gold ELECTROPLATING High Aspect ratio TRENCHES Gold Electrodepostion Di-rect current Electrodeposition PULSED vs. Direct current ELECTROPLATING Atomic LAYER Deposition Platinum Seed LAYER Silicon TRENCH Gratings TRENCH FILLING Grating FILLING ALD Adhesive LAYER
在线阅读 下载PDF
Correlation between current and cross-sectional area of parallel fixed-movable dual electrodes in ESC
13
作者 Li-ting Zhao Yun-long Xiong +2 位作者 Rui Chen Zeng-rui Wang An-guo Wang 《China Foundry》 SCIE 2020年第3期245-249,共5页
Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to desc... Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to describe the ideal correlation between the current ratio(y)and the cross-sectional area ratio(x)of the dual electrodes,where k is the filling ratio.Investigation was conducted on the electroslag casting process with dual electrodes of various cross-sectional areas,but at a constant k value.The experimental results indicated that the ideal correlation was obtained at the stable casting stage,and the fitting results were consistent with the experimental results at certain k values.The experimental findings show that better castings can be obtained when the current ratio is greater than 1.536 and the cross-sectional area ratio is greater than 0.5. 展开更多
关键词 electroslag casting fixed-movable dual electrode current ratio cross-sectional area ratio
在线阅读 下载PDF
基于Fisher Ratio的RBF网络在涡流定量检测中的应用
14
作者 孙晓云 刘东辉 李爱华 《无损检测》 北大核心 2008年第12期892-894,905,共4页
采用改进的RBF网络完成涡流定量检测。针对正交最小二乘法不能使网络结构得到最大优化这一缺点,提出应用Fisher Ratio方法选择RBF网络隐层节点数及径向基函数中心,正交变换及前向搜索算法完成结构优化。结果表明,能极大地简化网络结构,... 采用改进的RBF网络完成涡流定量检测。针对正交最小二乘法不能使网络结构得到最大优化这一缺点,提出应用Fisher Ratio方法选择RBF网络隐层节点数及径向基函数中心,正交变换及前向搜索算法完成结构优化。结果表明,能极大地简化网络结构,提高了分类能力和收敛精度,为神经网络在实时在线检测中的应用提供可能。 展开更多
关键词 涡流定量检测 改进RBF网络 FISHER ratio方法 在线检测
在线阅读 下载PDF
Signal processing for all fiber optical current transducer 被引量:1
15
作者 裴焕斗 祖静 陈鸿 《Journal of Central South University》 SCIE EI CAS 2008年第S2期404-408,共5页
The work principle of all fiber optical current transducer (AFOCT) was introduced. By analyzing the characteristic of photo-detector's output, a measurement and signal processing scheme based on sine wave modulati... The work principle of all fiber optical current transducer (AFOCT) was introduced. By analyzing the characteristic of photo-detector's output, a measurement and signal processing scheme based on sine wave modulation and demodulation was put forward for eliminating the influence of light intensity change and modulation degree change. A digital signal processing system and a calibration scheme were also advanced. The experimental data show that the mean ratio error is 0.016 74% for direct current and 0.035% for alternating current, and the correlation coefficient of linearity is up to 0.999 982 4, meeting the precision requirement of 0.2 grade. Stability experiments and temperature drift experiments show the AFOCT has a better stable capability. 展开更多
关键词 fiber OPTICAL current TRANSDUCER DEMODULATION SIGNAL processing ratio ERROR
在线阅读 下载PDF
高准确度电流比较仪研制及校验方法研究 被引量:1
16
作者 王维 刘夏 +1 位作者 黄璐 杨雁 《计量学报》 北大核心 2025年第1期112-118,共7页
介绍一种新型高准确度电流比较仪的结构及工作原理,提出了“屏蔽定向引流”线路结构。该结构可基本消除二次绕组容性泄漏误差,并可消除二次绕组各段组合使用时引入的附加误差,提高了电流比较仪的准确度。在电流比率5 A/5 A~5000 A/5 A... 介绍一种新型高准确度电流比较仪的结构及工作原理,提出了“屏蔽定向引流”线路结构。该结构可基本消除二次绕组容性泄漏误差,并可消除二次绕组各段组合使用时引入的附加误差,提高了电流比较仪的准确度。在电流比率5 A/5 A~5000 A/5 A范围内,达到的技术指标优于1×10-6。结合“屏蔽定向引流”线路结构的特点,进一步提出了多比率电流比较仪自校准方法,其校准不确定度优于2×10^(-7)。该校准方法准确度高,稳定性好,操作简单,耗时短,可有效解决过去长期困扰的互感器长途运输送检问题。 展开更多
关键词 电学计量 电流比例 电流比较仪 屏蔽定向引流 自校准方法
在线阅读 下载PDF
Feasibility study on buoyancy-weight ratios of a submerged floating tunnel prototype subjected to hydrodynamic loads 被引量:7
17
作者 Xu Long Fei Ge Youshi Hong 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2015年第5期750-761,共12页
The research progress of a novel traffic solution,a submerged floating tunnel(SFT),is reviewed in terms of a study approach and loading scenario.Among existing publications,the buoyancy-weight ratio(BWR) is usuall... The research progress of a novel traffic solution,a submerged floating tunnel(SFT),is reviewed in terms of a study approach and loading scenario.Among existing publications,the buoyancy-weight ratio(BWR) is usually predefined.However,BWR is a critical structural parameter that tremendously affects the dynamic behaviour of not only the tunnel tube itself but also the cable system.In the context of a SFT prototype(SFTP) project in Qiandao Lake(Zhejiang Province,China),the importance of BWR is illustrated by finite element analysis and subsequently,an optimized BWR is proposed within a reasonable range in the present study.In the numerical model,structural damping is identified to be of importance.Rayleigh damping and the corresponding Rayleigh coefficients are attained through a sensitivity study,which shows that the adopted damping ratios are fairly suitable for SFTP.Lastly,the human sense of security is considered by quantifying the comfort index,which helps further optimize BWR in the SFTP structural parameter design. 展开更多
关键词 Submerged floating tunnel Buoyancy-weight ratio Water wave and current loads Dynamic response Human security sense Comfort index
在线阅读 下载PDF
Feasibility study of a large-scale tuned mass damper with eddy current damping mechanism 被引量:22
18
作者 Wang Zhihao Chen Zhengqing Wang Jianhui 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第3期391-401,共11页
Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-kno... Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-known disadvantages, such as oil leakage and difficult adjustment of damping ratio for an operating TMD. Alternatively, eddy current damping (ECD) that does not require any contact with the main structure is a potential solution. This paper discusses the design, analysis, manufacture and testing of a large-scale horizontal TMD based on ECD. First, the theoretical model of ECD is formulated, then one large-scale horizontal TMD using ECD is constructed, and finally performance tests of the TMD are conducted. The test results show that the proposed TMD has a very low intrinsic damping ratio, while the damping ratio due to ECD is the dominant damping source, which can be as large as 15% in a proper configuration. In addition, the damping ratios estimated with the theoretical model are roughly consistent with those identified from the test results, and the source of this error is investigated. Moreover, it is demonstrated that the damping ratio in the proposed TMD can be easily adjusted by varying the air gap between permanent magnets and conductive plates. In view of practical applications, possible improvements and feasibility considerations for the proposed TMD are then discussed. It is confirmed that the proposed TMD with ECD is reliable and feasible for use in structural vibration control. 展开更多
关键词 tuned mass damper eddy current damping permanent magnets conductive plate modal damping ratio
在线阅读 下载PDF
基于零序电流幅值比的灵活接地系统高阻接地故障选线方法 被引量:1
19
作者 李晓波 张世乐 +4 位作者 刘栩鹏 刘硕 谢剑锋 袁璐健 彭超红 《电网技术》 北大核心 2025年第6期2595-2604,I0136-I0141,共16页
零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,... 零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,系统感知永久性接地故障后,于中性点投入并联小电阻,使得配电网接地方式发生转变,从而导致同一电气信号量呈现两种完全不同的故障特征,故障信息量增加了一倍,综合利用两阶段故障特征有望突破现有故障选线装置性能极限,摆脱选线装置对零序CT测量精度的依赖。为此,该文首先分析了灵活接地系统不同阶段各电气量的故障特征,之后结合灵活接地系统特点提出了一种基于零序电流幅值比的高阻接地故障选线方法,最后通过合理设计选线算法,剔除误差较大数据,最大程度降低保护对零序CT测量精度的依赖。实时数字仿真系统(real time digital simulation system,RTDS)以及低压实验平台实验结果表明,该方法不受零序CT极性反接与相位测量误差影响,且无需故障信息间的横向比较,具有耐过渡电阻能力强、可靠性高、对零序CT测量精度要求低、易实现等优点。 展开更多
关键词 零序电流互感器 灵活接地系统 零序电流幅值比 故障信息量 高阻接地故障
原文传递
上一页 1 2 53 下一页 到第
使用帮助 返回顶部