期刊文献+
共找到125,249篇文章
< 1 2 250 >
每页显示 20 50 100
Low-Density Pulsed Current Induced Refinement of Secondary α Phase for Strengthening Ti-6Al-4V-0.5Mo-0.5Zr Alloy Without Sacrificing Ductility
1
作者 Tu Yanni Luo Wei +2 位作者 Liu Huiqun Feng Weizhong Zhang Pinghui 《稀有金属材料与工程》 北大核心 2026年第1期78-91,共14页
Low-density short-duration pulsed current-assisted aging treatment was applied to the Ti-6Al-4V-0.5Mo-0.5Zr alloy subjected to different solution treatments.The results show that numerous α_(p) phases redissolve into... Low-density short-duration pulsed current-assisted aging treatment was applied to the Ti-6Al-4V-0.5Mo-0.5Zr alloy subjected to different solution treatments.The results show that numerous α_(p) phases redissolve into the new β phase during the pulsed current-assisted aging process,and then the newly formed β phase is mainly transformed into the β_(t) phase,with occasional transition to new α_(p) phase,leading to a remarkable grain refinement,especially for the lamellarαs phases.In comparison to conventional aging treatment,the pulsed current-assisted aging approach achieves a significant enhancement in strength without degrading ductility,yielding an excellent mechanical property combination:a yield strength of 932 MPa,a tensile strength of 1042 MPa,and an elongation of 12.2%.It is primarily ascribed to the increased fraction of β_(t) phases,the obvious grain refinement effect,and the slip block effect induced by the multiple-variantαs colonies distributed within β_(t) phases. 展开更多
关键词 titanium alloy pulsed current microstructure refinement strength DUCTILITY
原文传递
Robust current tracking control for three-phase grid-connected inverters with LCL filter
2
作者 LIU Wei WU Ben +2 位作者 SUN Wei-jie XUE Ying CAI Feng-huang 《控制理论与应用》 北大核心 2026年第1期41-51,共11页
This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons... This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters. 展开更多
关键词 grid-connected inverter internal model principle current tracking disturbance suppression robust control
在线阅读 下载PDF
Flame retardant polymer current collector for safer and higher energy density lithium-metal batteries
3
作者 Mintao Wan Huifang Fei +3 位作者 Haowen Liu Nae-Lih Wu Stefano Passerini Dominic Bresser 《Journal of Energy Chemistry》 2026年第3期799-807,共9页
Energy density and safety are two crucial parameters when evaluating lithium-metal batteries(LMBs).Herein,we present an ultralight polymer-based current collector,incorporating flame-retardant materials,designed speci... Energy density and safety are two crucial parameters when evaluating lithium-metal batteries(LMBs).Herein,we present an ultralight polymer-based current collector,incorporating flame-retardant materials,designed specifically for thin lithium-metal anodes.Compared to the traditional copper current collector(8.96 mg cm^(-2),10μm thick),the polymer-based current collector(12μm thick)has a significantly lower areal density of 1.41 mg cm^(-2),i.e.,only one-sixth of the copper collector,thus enabling substantially higher energy densities.Accordingly,when employed in Li||NMC_(622)full-cells,the polymer-based current collector enables a specific energy of 449 Wh kg^(-1),representing a notable improvement of about14.5%compared to cells employing a classic copper current collector.The inclusion of Al(OH)_(3) as a flame retardant into the current collector suppresses flammability and,thereby,significantly improves the safety of the resulting LMBs. 展开更多
关键词 current collector POLYMER Flame retardant Lithium-metal anode BATTERY
在线阅读 下载PDF
Recent progress in the modification of copper current collectors for lithium metal batteries
4
作者 Cheng Zhang Qitao Shi +7 位作者 Luwen Li Jiaqi Wang Zhipeng Wang Alicja Bachmatiuk Chen Lu Yanbin Shen Ruizhi Yang Mark H.Rümmeli 《Journal of Energy Chemistry》 2026年第3期848-867,共20页
Lithium metal batteries(LMBs)are promising candidates for next-generation high-energy-density storage devices.However,an unstable lithium metal anode poses significant issues that critically compromise battery safety ... Lithium metal batteries(LMBs)are promising candidates for next-generation high-energy-density storage devices.However,an unstable lithium metal anode poses significant issues that critically compromise battery safety and cycle life,including lithium dendrite formation,solid electrolyte interphase degradation,dead lithium accumulation,and substantial volume fluctuations during cycling.These problems can be addressed by regulating lithium deposition and suppressing side reactions through the modification of copper current collectors using three classes of materials:metal and metal oxide,carbon,and polymer materials.This review comprehensively examines recent advances in the application of these materials as current collector coatings.Particularly,their distinct roles in the lithium deposition process are analyzed to understand how they mitigate the issues associated with the lithium metal anode.Furthermore,their inherent limitations are considered to inform future research directions.While each class of materials offers specific advantages,multifunctionality is required to effectively regulate lithium deposition.In prospect,a novel composite copper current collector design that integrates the merits of the aforementioned advanced materials is proposed.The insights from this review provide valuable guidance for the rational design of modified copper current collectors,which would significantly improve the safety and cycle life of LMBs and advance their commercialization. 展开更多
关键词 Lithium metal battery Metal Metal oxide CARBON POLYMER Composite current collector
在线阅读 下载PDF
Parameter Optimization Strategy for VSC-HVDC Low-Voltage Ride-Through Considering Short-CIRCUIT Current and System Stability
5
作者 Zimin Zhu Yu Duan +3 位作者 Jian Ma Xiaoyun Wang Xiaoyu Deng Xiaofang Wu 《Energy Engineering》 2026年第4期321-340,共20页
When the converter bus voltage of a voltage source converter-based high voltage direct current(VSC-HVDC)system drops below a certain predetermined threshold,the system enters low-voltage ride-through(LVRT)mode to avoi... When the converter bus voltage of a voltage source converter-based high voltage direct current(VSC-HVDC)system drops below a certain predetermined threshold,the system enters low-voltage ride-through(LVRT)mode to avoid overcurrent and potential equipment failure,during which it operates as a controlled current source.The influence mechanism of LVRT control strategies on short-circuit current and overall system stability remains not yet fully and systematically investigated.First,this paper provides an overview of several LVRT strategies for VSC-HVDC systems and examines their effects on short-circuit current contribution.Next,it analyzes in detail the mechanisms through which active and reactive currents injected during LVRT impact system frequency stability,voltage stability,and synchronization stability.To address these interrelated issues,an optimized and comprehensive LVRT strategy incorporating short-circuit current constraints is proposed.The approach determines the active current ratio based on system frequency stability requirements and dynamically adjusts the active current recovery rate via phase control of the VSC-HVDC bus.The remaining capacity is allocated to reactive current support,thereby enhancing voltage and synchronization stability while maintaining sufficient short-circuit current margin and system frequency stability.Finally,simulations conducted on the PSS/E platform,using actual grid data from a selected cross-section system,validate convincingly the effectiveness of the proposed parameter optimization strategy for VSC-HVDC low-voltage ride-through. 展开更多
关键词 Short-circuit current VSC-HVDC systems LVRT voltage stability frequency stability synchronization stability
在线阅读 下载PDF
Current Situation of Application and Development Prospects of the Statistical Analysis of Big Data
6
作者 Zhuoran LI 《Meteorological and Environmental Research》 2026年第1期45-47,共3页
With the advent of the big data era,modern statistics has enjoyed unprecedented development opportunities and also faced numerous new challenges.Traditional statistical computing methods are often limited by issues su... With the advent of the big data era,modern statistics has enjoyed unprecedented development opportunities and also faced numerous new challenges.Traditional statistical computing methods are often limited by issues such as computer memory capacity and distributed storage of data across different locations,and are unable to directly apply to large-scale data sets.Therefore,in the context of big data,designing efficient and theoretically guaranteed statistical learning and inference algorithms has become a key issue that the current field of statistics urgently needs to address.In this paper,the application status of statistical analysis methods in the big data environment was systematically reviewed,and its future development directions were analyzed to provide reference and support for the further development of theory and methods of the statistical analysis of big data. 展开更多
关键词 Big data Statistical analysis current status Development prospects
在线阅读 下载PDF
Perspectives on Transcranial Direct Current Stimulation(tDCS)and Its Potential Integration With Nuclear Medicine as a Therapeutic Approach
7
作者 Suman Pradhan Subhasish Chatterjee Mousumi Saha 《Asia Pacific Journal of Clinical Medical Research》 2026年第1期1-4,共4页
Transcranial direct current stimulation(tDCS)is a non-invasive technique that modifies cortical excitability and induces neuroplasticity using low-intensity electrical currents.Nuclear medicine technologies like posit... Transcranial direct current stimulation(tDCS)is a non-invasive technique that modifies cortical excitability and induces neuroplasticity using low-intensity electrical currents.Nuclear medicine technologies like positron emission tomography(PET)and single-photon emission computed tomography(SPECT)can quantify cerebral metabolism and other dynamics.Evidence suggests that combining tDCS with these imaging methods enhances understanding and outcomes for neurological and psychiatric conditions.This review highlights how nuclear medicine can objectively characterize tDCS eff ects,map network modulation,and identify predictive biomarkers.PET and SPECT indicate changes in glucose metabolism and neurotransmitter activity post-tDCS,demonstrating their value in validation.While the co-application of these methodologies is still in conceptual stages,their integration may advance precision neuromodulation and inform rehabilitation strategies. 展开更多
关键词 DEPRESSION Nuclear Medicine Transcranial Direct current Stimulation Cortical Excitability Neuronal Plasticity TOMOGRAPHY
暂未订购
Impacts of Reactive Power Control Dynamics on Transient Stability of Grid-forming Converters Considering Current Saturation:Analysis and Enhancement
8
作者 Jinming Xu Hanxu Diao +3 位作者 Zihan Ling Jiarong Kan Yunhu Luo Shaojun Xie 《CSEE Journal of Power and Energy Systems》 2026年第1期56-70,共15页
The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited ... The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited attention paid to the impacts of control loop dynamics.However,the complex control dynamics,especially the interactions between the active/reactive power control loops and the current saturation process(CSP),are crucial for accurately describing the transient behavior and evaluating the stability.Thus,in this study,a new large-signal GFMC model is established,considering the reactive power control(RPC)with different kinds of controllers and the CSP simultaneously.It is revealed that GFMC does not switch to the current-limited mode immediately,and the dynamics of RPC further affect the transient behavior before the current limiting significantly.Hence,the complex control dynamics can alter the mode switching point of current saturation,thereby increasing the risk of loss of synchronization(LOS).Based on the above findings,comprehensive comparisons of typical RPC controllers are presented to facilitate practical engineering applications.A unified stability enhancement method is proposed for solving the problem of LOS.Finally,experiments validate the correctness of the analysis and the effectiveness of the proposed control strategy. 展开更多
关键词 current limit grid-forming converter reactive power control transient stability
原文传递
Oxidation behaviors of 430 ferritic stainless steel under coupling of electrical current and high temperature:quantitative evaluation for SOFC interconnector
9
作者 Hao Xie Yu-Nong Lei +6 位作者 Guo-Zun Tang Lin Hu Xing-Yue Liu Ao Huang Hua-Zhi Gu Jin-Yu Wang Lu Gan 《Journal of Iron and Steel Research International》 2026年第1期15-23,共9页
To elucidate the accelerated degradation mechanisms of metallic interconnects in operational solid oxide fuel cells,the oxidation behavior of FSS430 ferritic stainless steel under the coupling of simultaneous electric... To elucidate the accelerated degradation mechanisms of metallic interconnects in operational solid oxide fuel cells,the oxidation behavior of FSS430 ferritic stainless steel under the coupling of simultaneous electrical current and high-temperature exposure is investigated.Isothermal thermogravimetric analysis was employed to quantify oxidation kinetics,complemented by microstructural characterization using X-ray diffraction,scanning electron microscopy with energy-dispersive spectroscopy and transmission electron microscopy.Experimental results demonstrate that the applied current dramatically enhances oxidation rates,increasing specific mass gain from 0.25 mg/cm^(2)(0 A/cm^(2))to 5.20 mg/cm^(2)(0.2 A/cm^(2))and oxide scale thickness from 1.87 to 15.62μm after 200 h.This acceleration originates from current-induced electromigration forces that promote cationic transport through the oxide layer.The quantitative relationships between current density and oxidation parameters are established,enabling predictive modeling of interconnector degradation in solid oxide fuel cell(SOFC)systems. 展开更多
关键词 Stainless steel Electrical current High-temperature oxidation Oxidation protection Solid oxide fuel cell
原文传递
Does transcranial direct current stimulation enhance the hypoalgesic effect of exercise?
10
作者 Aidan Lewis Ben Rattray +1 位作者 Constantino Toufexis Andrew Flood 《Sports Medicine and Health Science》 2026年第1期102-109,共8页
Exercise produces a decrease in pain sensitivity via an effect called exercise-induced hypoalgesia(EIH).Transcranial direct current stimulation(tDCS),acting on similar analgesic mechanisms as EIH,represents a potentia... Exercise produces a decrease in pain sensitivity via an effect called exercise-induced hypoalgesia(EIH).Transcranial direct current stimulation(tDCS),acting on similar analgesic mechanisms as EIH,represents a potential complementary intervention that may amplify the effects of exercise on pain.This study aimed to explore if anodal tDCS could enhance the effect of exercise on pain compared to exercise alone.A total of 35 healthy participants aged 19–37 years completed a familiarisation session followed by two separate sessions where active and sham tDCS was applied in a randomised cross-over design.The familiarisation session involved familiarisation to the pain assessment and exercise tasks,while the subsequent tDCS sessions involved pain sensitivity assessment,exercise and either anodal tDCS or sham tDCS.tDCS doses were applied at 2 mA over the primary motor cortex for 10 min,with the reference electrode placed over the contralateral supraorbital area.The exercise task involved a sustained isometric grip strength contraction at 35%of maximal voluntary contraction(MVC)until volitional exhaustion.Pain sensitivity was evaluated as pressure pain threshold before tDCS,after tDCS,and after exercise.Across both tDCS conditions,pain threshold was higher after exercise when compared to pre-and post-tDCS measurement.This increase in pain threshold did not differ between active and sham tDCS conditions.Our findings suggest that the hypoalgesic effects of active anodal tDCS over the motor cortex prior to exercise are no greater than the effects of sham tDCS prior to exercise. 展开更多
关键词 Transcranial direct current stimulation Grip strength Pain sensitivity Time to exhaustion Pain pressure threshold TDCS
在线阅读 下载PDF
A Composite Multi-Port Hybrid DC Circuit Breaker with DC Power Flow and Fault Current Limitation Abilities
11
作者 Xiaoya Chen Chao Zhang +5 位作者 Xufeng Yuan Wei Xiong Zhiyang Lu Huajun Zheng Yutao Xu Zhukui Tan 《Energy Engineering》 2026年第3期306-325,共20页
To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distributio... To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distribution networks,this paper adopts a component sharing mechanism to propose a composite multi-port hybrid DC circuit breaker(CM-HCB)with DC power flow and fault current limitation abilities,as well as reduced component costs.The proposed CM-HCB topology enables the sharing of the main breaker branch(MB)and the energy dissipation branch,while the load commutation switches(LCSs)in the main branch are reused as power flow control components,enabling flexible regulation of power flow in multiple lines.Meanwhile,by reconstructing the current path during the fault process,the proposed CM-HCB can utilize the internal coupled inductor to limit the current rise rate at the initial stage of the fault,significantly reducing the requirement for breaking current.A detailed study on the topological structure,steady-state power flow regulation mechanism,transient fault isolation mechanism,control strategy and characteristic analysis of the proposed CM-HCB is presented.Then,a Matlab/Simulink-based meshed three-terminal DC grid simulation platform with the proposed CM-HCB is built.The results indicate that the proposed CM-HCB can not only achieve flexible power flow control during steady-state operation,but also obtain current rise limitation and fault isolation abilities under short-circuit fault conditions,verifying its correctness and effectiveness.Finally,a comparative economic analysis is conducted between the proposed CM-HCB and the other two existing solutions,confirming that its component sharing mechanism can significantly reduce the number of components,lower system costs,and improve component utilization. 展开更多
关键词 DC power grid DC power flow control fault current limiting fault isolation hybrid DC circuit breaker
在线阅读 下载PDF
Transient Overcurrent Suppression and Fault Ride-through Strategy for Grid-forming DFIGs Based on Flux Linkage Tracking Control
12
作者 Meng Huang Sirui Shu +3 位作者 Yufei Hu Zhen Tian Xiaoming Zha Wenhe Wang 《CSEE Journal of Power and Energy Systems》 2026年第1期71-83,共13页
Virtor(VSG)technology is widely investigated and applied for dual synchronous generatoubly-fed induction generators(DFIGs)to provide virtual inertia.However,under grid faults,the conventional VSG-based DFIG faces chal... Virtor(VSG)technology is widely investigated and applied for dual synchronous generatoubly-fed induction generators(DFIGs)to provide virtual inertia.However,under grid faults,the conventional VSG-based DFIG faces challenges of transient overcurrent and instability.The critical limitation for grid-forming DFIGs to withstand serious grid faults is the rotor-side converter(RSC)’s inability to quickly generate proper rotor voltage to counteract transient electromotive force(EMF),which results in transient overcurrent and damage to the RSC.To fill this gap,this study introduces a novel low-voltage ride-through(LVRT)control strategy for the grid-forming DFIG under symmetrical grid fault conditions.To mitigate transient overcurrent,the core mechanism is to regulate the rotor flux linkage to align with the stator flux linkage in an optimal proportion.Under the proposed control strategy,both post-fault rotor current and required rotor voltage are constrained within operational limits.Moreover,fluctuations in electromagnetic torque are efficiently suppressed during grid disturbances.Consequently,the dynamic stability and power support capacity of the DFIG system remain intact throughout the transient process.Finally,simulation studies and experimental results are provided to verify the feasibility of the proposed approach. 展开更多
关键词 Doubly-fed induction generator(DFIG) grid-forming converter low-voltage ride through(LVRT) transient current virtual synchronous generator(VSG)
原文传递
Integrated Equipment with Functions of Current Flow Control and Fault Isolation for Multiterminal DC Grids 被引量:1
13
作者 Shuo Zhang Guibin Zou 《Energy Engineering》 EI 2025年第1期85-99,共15页
The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow ... The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract. 展开更多
关键词 Integrated equipment multiterminal direct current grid current flow control fault isolation
在线阅读 下载PDF
Currents from relativistic laser-plasma interaction as a novel metrology for the system stability of high-repetition-rate laser secondary sources 被引量:1
14
作者 Michael Ehret Iuliana-Mariana Vladisavlevici +16 位作者 Philip Wykeham Bradford Jakub Cikhardt Evgeny Filippov Jose Luis Henares Rubén Hernández Martín Diego de Luis JoséAntonio Pérez-Hernández Pablo Vicente Tomas Burian Enrique García-García Juan Hernández Cruz Mendez Marta Olivar Ruíz Óscar Varela Maria Dolores Rodríguez Frías João Jorge Santos Giancarlo Gatti 《Matter and Radiation at Extremes》 2025年第2期24-34,共11页
This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven second... This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven secondary sources,taking as an example ion acceleration by target normal sheath acceleration.The Pearson linear correlation of maximum return current amplitude and proton spectrum cutoff energy is found to be in the range from~0.70 to 0.94.kA-scale return currents rise in all interaction schemes where targets of any kind are charged by escaping laser-accelerated relativistic electrons.Their precise measurement is demonstrated using an inductive scheme that allows operation at high repetition rates.Thus,return currents can be used as a metrological online tool for the optimization of many laser-driven secondary sources and for diagnosing their stability.In particular,in two parametric studies of laser-driven ion acceleration,we carry out a noninvasive online measurement of return currents in a tape target system irradiated by the 1 PW VEGA-3 laser at Centro de Láseres Pulsados:first the size of the irradiated area is varied at best compression of the laser pulse;second,the pulse duration is varied by means of induced group delay dispersion at best focus.This work paves the way to the development of feedback systems that operate at the high repetition rates of PW-class lasers. 展开更多
关键词 relativistic laser plasma interaction pearson linear correlation proton spectrum cutoff energy interaction schemes ion acceleration target normal sheath accelerationthe return current return currents
在线阅读 下载PDF
A FPGA-based high-order harmonic current control of resonant power supply system in rapid-cycling synchrotron
15
作者 Ran Li Jun Li +4 位作者 Guo‑Dong Zhao Wen‑Qing Zhang Yun‑Tao Liu Yuan Huang Xin Qi 《Nuclear Science and Techniques》 2025年第8期111-125,共15页
The rapid-cycling synchrotron(RCS)is a crucial device for proton beam acceleration at the China Spallation Neutron Source,operating at a repetition frequency of 25 Hz.The beam power was increased from 100 kW to 140 kW... The rapid-cycling synchrotron(RCS)is a crucial device for proton beam acceleration at the China Spallation Neutron Source,operating at a repetition frequency of 25 Hz.The beam power was increased from 100 kW to 140 kW.This increase makes the on-orbit beam more sensitive to disturbances in various parts of the accelerator,including the RCS magnet power supply system.This paper presents a method for reducing the high-order harmonic current error in resonant power supplies for dipole magnets and examines its impact on the horizontal orbit offset of the beam.It adopts a control scheme that combines high-order harmonic current compensation with PI double-loop control of the resonant power supply.By utilizing the existing digital controller hardware in the RCS power supply system,this study demonstrates how to achieve precise control of the 50 Hz harmonic current output in a cost-effective manner.Ultimately,it enhances performance by reducing the current error by up to 50%and provides methodological support for future upgrades to the power supply system.Such improvements enhance the stability of the RCS,reducing the beam horizontal orbit deviation by at least 19.8%. 展开更多
关键词 current error analysis Magnets saturation White resonant circuit FPGA Harmonic current compensation algorithm
在线阅读 下载PDF
Experimental demonstration and mechanism study of single-event gate leakage current in 4H-SiC power MOSFET with top oxide and double P-well structures
16
作者 Yin Luo Keyu Liu +5 位作者 Hao Yuan Zhiwen Zhang Chao Han Xiaoyan Tang Qingwen Song Yuming Zhang 《Chinese Physics B》 2025年第9期609-613,共5页
This work proposes and fabricates the 4H-SiC power MOSFET with top oxide and double P-well(TODP-MOSFET)to enhance the single-event radiation tolerance of the gate oxide.Simulation results suggest that the proposed TOD... This work proposes and fabricates the 4H-SiC power MOSFET with top oxide and double P-well(TODP-MOSFET)to enhance the single-event radiation tolerance of the gate oxide.Simulation results suggest that the proposed TODP structure reduces the peak electric field within the oxide and minimizes the sensitive region by more than 70%compared to C-MOSFETs.Experimental results show that the gate degradation voltage of the TODP-MOSFET is higher than that of the C-MOSFET,and the gate leakage current is reduced by 95%compared to the C-MOSFET under heavy-ion irradiation with a linear energy transfer(LET)value exceeding 75 MeV·cm^(2)/mg. 展开更多
关键词 silicon carbide single-event leakage current(SELC) gate oxide electricfield gate leakage current velocity
原文传递
Calculation of Commutation Failure Overvoltage in High-Voltage Direct Current Transmission Terminal Systems with Grid-Forming Renewable Energy Sources
17
作者 Weibing Xu Bo Yao +5 位作者 Xiangjun Quan Xunyou Zhang Ning Zou Shuo Liu Jia Wang Jiansuo Zhang 《Energy Engineering》 2025年第10期4225-4243,共19页
The integration of large-scale new energy and high-capacity DC transmission leads to a reduction in system inertia.Grid-forming renewable energy sources(GF-RES)has a significant improvement effect on system inertia.Co... The integration of large-scale new energy and high-capacity DC transmission leads to a reduction in system inertia.Grid-forming renewable energy sources(GF-RES)has a significant improvement effect on system inertia.Commutation failure faults may cause a short-term reactive power surplus at the sending end and trigger transient overvoltage,threatening the safe and stable operation of the power grid.However,there is a lack of research on the calculation method of transient overvoltage caused by commutation failure in high-voltage DC transmission systems with grid-forming renewable energy sources integration.Based on the existing equivalent model of highvoltage DC transmission systems at the sending end,this paper proposes to construct a model of the high-voltage DC transmission system at the sending end with grid-forming renewable energy sources.The paper first clarifies the mechanism of overvoltage generation,then considers the reactive power droop control characteristics of GF-RES,and derives the transient voltage calculation model of theDC transmission system with GF-RES integration.It also proposes a calculation method for transient overvoltage at the sending-end converter bus with GF-RES integration.Based on the PSCAD/EMTDC simulation platform,this paper builds an experimental simulation model.By constructing three different experimental scenarios,the accuracy and effectiveness of the proposed transient overvoltage calculation method are verified,with a calculation error within 5%.At the same time,this paper quantitatively analyzes the impact of grid strength,new energy proportion,and rated transmission power on transient overvoltage from three different perspectives. 展开更多
关键词 Grid-forming renewable energy commutation failure transient overvoltage high-voltage direct current sending-end direct current system
在线阅读 下载PDF
Loop-Current Fluctuations Mediated Chiral d-Wave Pairing in Kagome Lattice
18
作者 Qi-Fang Li Gaopei Pan +4 位作者 Xu Zhang Satoru Nakatsuji Weilun Jiang Xiao Yan Xu Xianxin Wu 《Chinese Physics Letters》 2025年第5期123-139,共17页
Recent various experiments have provided evidence supporting the emergence of loop-current order in kagome metals. Particularly superconductivity in AV_(3)Sb_(5) is significantly enhanced when this charge order is sup... Recent various experiments have provided evidence supporting the emergence of loop-current order in kagome metals. Particularly superconductivity in AV_(3)Sb_(5) is significantly enhanced when this charge order is suppressed by pressure or doping. Distinct from magnetic order, loop-current order does not couple directly to spin and thus whether such fluctuations can enhance superconductivity remains elusive. We design a sign problem-free bilayer kagome model coupled to quantum Ising spins through bond currents and perform determinant quantum Monte Carlo simulations to explore single-particle properties and superconductivity arising from 2 × 2 loopcurrent fluctuations. We find that this loop-current order induces intriguing band folding, band broadening,and gap opening around saddle points. Remarkably, our pairing susceptibility analysis identifies a dominant enhancement of superconductivity due to loop-current fluctuations, with the dominant pairing being the chiral d-wave channel. This pairing primarily occurs within the intra-sublattice channel and involves third nearestneighbor sites, attributed to the unique sublattice texture associated with van Hove singularities. We also discuss potential experimental implications for kagome superconductors. 展开更多
关键词 kagome metals quantum ising spins quantum monte carlo simulations bond current enhance superconductivity chiral d wave pairing loop current fluctuations kagome lattice
原文传递
Giant Uncompensated Magnon Spin Currents in X-Type Magnets
19
作者 Zi-An Wang Bo Li +7 位作者 Shui-Sen Zhang Wen-Jian Lu Mingliang Tian Yu-Ping Sun Evgeny Y.Tsymbal Kaiyou Wang Haifeng Du Ding-Fu Shao 《Chinese Physics Letters》 2025年第11期354-374,共21页
Magnon spin currents in insulating magnets are useful for low-power spintronics. However, in magnets stacked by antiferromagnetic(AFM) exchange coupling, which have recently aroused significant interest for potential ... Magnon spin currents in insulating magnets are useful for low-power spintronics. However, in magnets stacked by antiferromagnetic(AFM) exchange coupling, which have recently aroused significant interest for potential applications in spintronics, Bose–Einstein distribution populates magnon states across all energies from opposite eigenmodes, and hence the magnon spin current is largely compensated. Contrary to this common observation,here, we show that magnets with X-type AFM stacking, where opposite magnetic sublattices form orthogonal intersecting chains, support giant magnon spin currents with minimal compensation. Our model Hamiltonian calculations predict magnetic chain locking of magnon spin currents in these X-type magnets, significantly reducing their compensation ratio. In addition, the one-dimensional nature of the chain-like magnetic sublattices enhances magnon spin conductivities surpassing those of two-dimensional ferromagnets and canonical altermagnets. Notably, uncompensated X-type magnets, such as odd-layer antiferromagnets and ferrimagnets, can exhibit magnon spin currents polarized opposite to those expected by their net magnetization. These unprecedented properties of X-type magnets, combined with their inherent advantages resulting from AFM coupling, offer a promising new path for low-power high-performance spintronics. 展开更多
关键词 magnon spin currents giant magnon spin currents antiferromagnetic exchange coupling magnetic chain locking bose einstein distribution insulating magnets x type magnets
原文传递
Short-term effects of transcranial direct current stimulation on pain sensitivity, emotional and cognitive processes in non-suicidal self-injury: a randomised controlled trial
20
作者 Chang Lei Diyang Qu +4 位作者 Dennis Chong Yangyang Yi Weijian Wu Yiheng Tu Runsen Chen 《General Psychiatry》 2025年第3期176-185,共10页
Background Pain sensitivity is critical for preventing non-suicidal self-injury(NSSI)behaviours;however,individuals engaging in such behaviours often exhibit decreased pain sensitivity,which may undermine this natural... Background Pain sensitivity is critical for preventing non-suicidal self-injury(NSSI)behaviours;however,individuals engaging in such behaviours often exhibit decreased pain sensitivity,which may undermine this natural safeguard.The dorsolateral prefrontal cortex(DLPFC)is a key region involved in pain regulation,and recent approaches using transcranial direct current stimulation(tDCS)to target the DLPFC have shown potential for modulating pain processing and restoring normal pain perception for individuals engaging in NSSI behaviours.Aims This study aimed to explore the immediate and short-term effects of a single session of tDCS on pain sensitivity in individuals with NSSI,as well as its secondary effects on mood and NSSI-related factors.Methods In this randomised,double-blind,parallel,sham-controlled clinical trial,participants with a history of NSSI were randomly assigned to receive either active or sham tDCS.The intervention consisted of a single 20 min tDCS session targeting the left DLPFC.The primary outcome was pain sensitivity,measured by the pressure pain threshold(PPT)and heat pain score(HPS).Secondary and additional outcomes included NSSI urges,NSSI resistance,self-efficacy in resisting NSSI,mood-related variables and exploratory cognitive-affective processes such as rumination,self-criticism and self-perceived pain sensitivity,assessed at baseline,immediately post-intervention,and at 24 hours,1 week and 2 weeks follow-ups.Results For the primary outcomes,no significant differences between groups were observed for pain sensitivity(PPT,padj=0.812;HPS,padj=0.608).However,an exploratory sensitivity analysis treating each trial as an individual observation revealed a significant effect on HPS(padj=0.036).For the secondary and additional outcomes,although there were initial improvements in joyful feelings and reductions in negative affect at 2 weeks post-intervention,these effects did not remain significant after multiple comparison corrections.Notably,reductions in rumination were statistically significant at both 1-week and 2-week follow-ups(1 week,p_(adj)=0.040;2 weeks,p_(adj)=0.042).There were no significant effects on NSSI urges,NSSI resistance,self-efficacy in resisting NSSI or self-criticism.Conclusions A single session of tDCS over the left DLPFC did not produce significant changes in pain sensitivity in individuals with NSSI.A sensitivity analysis indicated an effect on heat pain sensitivity,possibly reflecting changes in brain activity,warranting confirmation through neuroimaging.These findings suggest that tDCS warrants further investigation for its potential to influence pain-related cognitive-affective processes in individuals with NSSI. 展开更多
关键词 Non Suicidal Self Injury MOOD Dorsolateral Prefrontal Cortex modulating pain processing Transcranial Direct current Stimulation Cognitive Processes dorsolateral prefrontal cortex dlpfc transcranial direct current stimulation tdcs
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部