Low-density short-duration pulsed current-assisted aging treatment was applied to the Ti-6Al-4V-0.5Mo-0.5Zr alloy subjected to different solution treatments.The results show that numerous α_(p) phases redissolve into...Low-density short-duration pulsed current-assisted aging treatment was applied to the Ti-6Al-4V-0.5Mo-0.5Zr alloy subjected to different solution treatments.The results show that numerous α_(p) phases redissolve into the new β phase during the pulsed current-assisted aging process,and then the newly formed β phase is mainly transformed into the β_(t) phase,with occasional transition to new α_(p) phase,leading to a remarkable grain refinement,especially for the lamellarαs phases.In comparison to conventional aging treatment,the pulsed current-assisted aging approach achieves a significant enhancement in strength without degrading ductility,yielding an excellent mechanical property combination:a yield strength of 932 MPa,a tensile strength of 1042 MPa,and an elongation of 12.2%.It is primarily ascribed to the increased fraction of β_(t) phases,the obvious grain refinement effect,and the slip block effect induced by the multiple-variantαs colonies distributed within β_(t) phases.展开更多
This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons...This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.展开更多
Energy density and safety are two crucial parameters when evaluating lithium-metal batteries(LMBs).Herein,we present an ultralight polymer-based current collector,incorporating flame-retardant materials,designed speci...Energy density and safety are two crucial parameters when evaluating lithium-metal batteries(LMBs).Herein,we present an ultralight polymer-based current collector,incorporating flame-retardant materials,designed specifically for thin lithium-metal anodes.Compared to the traditional copper current collector(8.96 mg cm^(-2),10μm thick),the polymer-based current collector(12μm thick)has a significantly lower areal density of 1.41 mg cm^(-2),i.e.,only one-sixth of the copper collector,thus enabling substantially higher energy densities.Accordingly,when employed in Li||NMC_(622)full-cells,the polymer-based current collector enables a specific energy of 449 Wh kg^(-1),representing a notable improvement of about14.5%compared to cells employing a classic copper current collector.The inclusion of Al(OH)_(3) as a flame retardant into the current collector suppresses flammability and,thereby,significantly improves the safety of the resulting LMBs.展开更多
Lithium metal batteries(LMBs)are promising candidates for next-generation high-energy-density storage devices.However,an unstable lithium metal anode poses significant issues that critically compromise battery safety ...Lithium metal batteries(LMBs)are promising candidates for next-generation high-energy-density storage devices.However,an unstable lithium metal anode poses significant issues that critically compromise battery safety and cycle life,including lithium dendrite formation,solid electrolyte interphase degradation,dead lithium accumulation,and substantial volume fluctuations during cycling.These problems can be addressed by regulating lithium deposition and suppressing side reactions through the modification of copper current collectors using three classes of materials:metal and metal oxide,carbon,and polymer materials.This review comprehensively examines recent advances in the application of these materials as current collector coatings.Particularly,their distinct roles in the lithium deposition process are analyzed to understand how they mitigate the issues associated with the lithium metal anode.Furthermore,their inherent limitations are considered to inform future research directions.While each class of materials offers specific advantages,multifunctionality is required to effectively regulate lithium deposition.In prospect,a novel composite copper current collector design that integrates the merits of the aforementioned advanced materials is proposed.The insights from this review provide valuable guidance for the rational design of modified copper current collectors,which would significantly improve the safety and cycle life of LMBs and advance their commercialization.展开更多
When the converter bus voltage of a voltage source converter-based high voltage direct current(VSC-HVDC)system drops below a certain predetermined threshold,the system enters low-voltage ride-through(LVRT)mode to avoi...When the converter bus voltage of a voltage source converter-based high voltage direct current(VSC-HVDC)system drops below a certain predetermined threshold,the system enters low-voltage ride-through(LVRT)mode to avoid overcurrent and potential equipment failure,during which it operates as a controlled current source.The influence mechanism of LVRT control strategies on short-circuit current and overall system stability remains not yet fully and systematically investigated.First,this paper provides an overview of several LVRT strategies for VSC-HVDC systems and examines their effects on short-circuit current contribution.Next,it analyzes in detail the mechanisms through which active and reactive currents injected during LVRT impact system frequency stability,voltage stability,and synchronization stability.To address these interrelated issues,an optimized and comprehensive LVRT strategy incorporating short-circuit current constraints is proposed.The approach determines the active current ratio based on system frequency stability requirements and dynamically adjusts the active current recovery rate via phase control of the VSC-HVDC bus.The remaining capacity is allocated to reactive current support,thereby enhancing voltage and synchronization stability while maintaining sufficient short-circuit current margin and system frequency stability.Finally,simulations conducted on the PSS/E platform,using actual grid data from a selected cross-section system,validate convincingly the effectiveness of the proposed parameter optimization strategy for VSC-HVDC low-voltage ride-through.展开更多
With the advent of the big data era,modern statistics has enjoyed unprecedented development opportunities and also faced numerous new challenges.Traditional statistical computing methods are often limited by issues su...With the advent of the big data era,modern statistics has enjoyed unprecedented development opportunities and also faced numerous new challenges.Traditional statistical computing methods are often limited by issues such as computer memory capacity and distributed storage of data across different locations,and are unable to directly apply to large-scale data sets.Therefore,in the context of big data,designing efficient and theoretically guaranteed statistical learning and inference algorithms has become a key issue that the current field of statistics urgently needs to address.In this paper,the application status of statistical analysis methods in the big data environment was systematically reviewed,and its future development directions were analyzed to provide reference and support for the further development of theory and methods of the statistical analysis of big data.展开更多
Transcranial direct current stimulation(tDCS)is a non-invasive technique that modifies cortical excitability and induces neuroplasticity using low-intensity electrical currents.Nuclear medicine technologies like posit...Transcranial direct current stimulation(tDCS)is a non-invasive technique that modifies cortical excitability and induces neuroplasticity using low-intensity electrical currents.Nuclear medicine technologies like positron emission tomography(PET)and single-photon emission computed tomography(SPECT)can quantify cerebral metabolism and other dynamics.Evidence suggests that combining tDCS with these imaging methods enhances understanding and outcomes for neurological and psychiatric conditions.This review highlights how nuclear medicine can objectively characterize tDCS eff ects,map network modulation,and identify predictive biomarkers.PET and SPECT indicate changes in glucose metabolism and neurotransmitter activity post-tDCS,demonstrating their value in validation.While the co-application of these methodologies is still in conceptual stages,their integration may advance precision neuromodulation and inform rehabilitation strategies.展开更多
The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited ...The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited attention paid to the impacts of control loop dynamics.However,the complex control dynamics,especially the interactions between the active/reactive power control loops and the current saturation process(CSP),are crucial for accurately describing the transient behavior and evaluating the stability.Thus,in this study,a new large-signal GFMC model is established,considering the reactive power control(RPC)with different kinds of controllers and the CSP simultaneously.It is revealed that GFMC does not switch to the current-limited mode immediately,and the dynamics of RPC further affect the transient behavior before the current limiting significantly.Hence,the complex control dynamics can alter the mode switching point of current saturation,thereby increasing the risk of loss of synchronization(LOS).Based on the above findings,comprehensive comparisons of typical RPC controllers are presented to facilitate practical engineering applications.A unified stability enhancement method is proposed for solving the problem of LOS.Finally,experiments validate the correctness of the analysis and the effectiveness of the proposed control strategy.展开更多
To elucidate the accelerated degradation mechanisms of metallic interconnects in operational solid oxide fuel cells,the oxidation behavior of FSS430 ferritic stainless steel under the coupling of simultaneous electric...To elucidate the accelerated degradation mechanisms of metallic interconnects in operational solid oxide fuel cells,the oxidation behavior of FSS430 ferritic stainless steel under the coupling of simultaneous electrical current and high-temperature exposure is investigated.Isothermal thermogravimetric analysis was employed to quantify oxidation kinetics,complemented by microstructural characterization using X-ray diffraction,scanning electron microscopy with energy-dispersive spectroscopy and transmission electron microscopy.Experimental results demonstrate that the applied current dramatically enhances oxidation rates,increasing specific mass gain from 0.25 mg/cm^(2)(0 A/cm^(2))to 5.20 mg/cm^(2)(0.2 A/cm^(2))and oxide scale thickness from 1.87 to 15.62μm after 200 h.This acceleration originates from current-induced electromigration forces that promote cationic transport through the oxide layer.The quantitative relationships between current density and oxidation parameters are established,enabling predictive modeling of interconnector degradation in solid oxide fuel cell(SOFC)systems.展开更多
Exercise produces a decrease in pain sensitivity via an effect called exercise-induced hypoalgesia(EIH).Transcranial direct current stimulation(tDCS),acting on similar analgesic mechanisms as EIH,represents a potentia...Exercise produces a decrease in pain sensitivity via an effect called exercise-induced hypoalgesia(EIH).Transcranial direct current stimulation(tDCS),acting on similar analgesic mechanisms as EIH,represents a potential complementary intervention that may amplify the effects of exercise on pain.This study aimed to explore if anodal tDCS could enhance the effect of exercise on pain compared to exercise alone.A total of 35 healthy participants aged 19–37 years completed a familiarisation session followed by two separate sessions where active and sham tDCS was applied in a randomised cross-over design.The familiarisation session involved familiarisation to the pain assessment and exercise tasks,while the subsequent tDCS sessions involved pain sensitivity assessment,exercise and either anodal tDCS or sham tDCS.tDCS doses were applied at 2 mA over the primary motor cortex for 10 min,with the reference electrode placed over the contralateral supraorbital area.The exercise task involved a sustained isometric grip strength contraction at 35%of maximal voluntary contraction(MVC)until volitional exhaustion.Pain sensitivity was evaluated as pressure pain threshold before tDCS,after tDCS,and after exercise.Across both tDCS conditions,pain threshold was higher after exercise when compared to pre-and post-tDCS measurement.This increase in pain threshold did not differ between active and sham tDCS conditions.Our findings suggest that the hypoalgesic effects of active anodal tDCS over the motor cortex prior to exercise are no greater than the effects of sham tDCS prior to exercise.展开更多
To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distributio...To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distribution networks,this paper adopts a component sharing mechanism to propose a composite multi-port hybrid DC circuit breaker(CM-HCB)with DC power flow and fault current limitation abilities,as well as reduced component costs.The proposed CM-HCB topology enables the sharing of the main breaker branch(MB)and the energy dissipation branch,while the load commutation switches(LCSs)in the main branch are reused as power flow control components,enabling flexible regulation of power flow in multiple lines.Meanwhile,by reconstructing the current path during the fault process,the proposed CM-HCB can utilize the internal coupled inductor to limit the current rise rate at the initial stage of the fault,significantly reducing the requirement for breaking current.A detailed study on the topological structure,steady-state power flow regulation mechanism,transient fault isolation mechanism,control strategy and characteristic analysis of the proposed CM-HCB is presented.Then,a Matlab/Simulink-based meshed three-terminal DC grid simulation platform with the proposed CM-HCB is built.The results indicate that the proposed CM-HCB can not only achieve flexible power flow control during steady-state operation,but also obtain current rise limitation and fault isolation abilities under short-circuit fault conditions,verifying its correctness and effectiveness.Finally,a comparative economic analysis is conducted between the proposed CM-HCB and the other two existing solutions,confirming that its component sharing mechanism can significantly reduce the number of components,lower system costs,and improve component utilization.展开更多
Virtor(VSG)technology is widely investigated and applied for dual synchronous generatoubly-fed induction generators(DFIGs)to provide virtual inertia.However,under grid faults,the conventional VSG-based DFIG faces chal...Virtor(VSG)technology is widely investigated and applied for dual synchronous generatoubly-fed induction generators(DFIGs)to provide virtual inertia.However,under grid faults,the conventional VSG-based DFIG faces challenges of transient overcurrent and instability.The critical limitation for grid-forming DFIGs to withstand serious grid faults is the rotor-side converter(RSC)’s inability to quickly generate proper rotor voltage to counteract transient electromotive force(EMF),which results in transient overcurrent and damage to the RSC.To fill this gap,this study introduces a novel low-voltage ride-through(LVRT)control strategy for the grid-forming DFIG under symmetrical grid fault conditions.To mitigate transient overcurrent,the core mechanism is to regulate the rotor flux linkage to align with the stator flux linkage in an optimal proportion.Under the proposed control strategy,both post-fault rotor current and required rotor voltage are constrained within operational limits.Moreover,fluctuations in electromagnetic torque are efficiently suppressed during grid disturbances.Consequently,the dynamic stability and power support capacity of the DFIG system remain intact throughout the transient process.Finally,simulation studies and experimental results are provided to verify the feasibility of the proposed approach.展开更多
The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow ...The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract.展开更多
This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven second...This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven secondary sources,taking as an example ion acceleration by target normal sheath acceleration.The Pearson linear correlation of maximum return current amplitude and proton spectrum cutoff energy is found to be in the range from~0.70 to 0.94.kA-scale return currents rise in all interaction schemes where targets of any kind are charged by escaping laser-accelerated relativistic electrons.Their precise measurement is demonstrated using an inductive scheme that allows operation at high repetition rates.Thus,return currents can be used as a metrological online tool for the optimization of many laser-driven secondary sources and for diagnosing their stability.In particular,in two parametric studies of laser-driven ion acceleration,we carry out a noninvasive online measurement of return currents in a tape target system irradiated by the 1 PW VEGA-3 laser at Centro de Láseres Pulsados:first the size of the irradiated area is varied at best compression of the laser pulse;second,the pulse duration is varied by means of induced group delay dispersion at best focus.This work paves the way to the development of feedback systems that operate at the high repetition rates of PW-class lasers.展开更多
The rapid-cycling synchrotron(RCS)is a crucial device for proton beam acceleration at the China Spallation Neutron Source,operating at a repetition frequency of 25 Hz.The beam power was increased from 100 kW to 140 kW...The rapid-cycling synchrotron(RCS)is a crucial device for proton beam acceleration at the China Spallation Neutron Source,operating at a repetition frequency of 25 Hz.The beam power was increased from 100 kW to 140 kW.This increase makes the on-orbit beam more sensitive to disturbances in various parts of the accelerator,including the RCS magnet power supply system.This paper presents a method for reducing the high-order harmonic current error in resonant power supplies for dipole magnets and examines its impact on the horizontal orbit offset of the beam.It adopts a control scheme that combines high-order harmonic current compensation with PI double-loop control of the resonant power supply.By utilizing the existing digital controller hardware in the RCS power supply system,this study demonstrates how to achieve precise control of the 50 Hz harmonic current output in a cost-effective manner.Ultimately,it enhances performance by reducing the current error by up to 50%and provides methodological support for future upgrades to the power supply system.Such improvements enhance the stability of the RCS,reducing the beam horizontal orbit deviation by at least 19.8%.展开更多
This work proposes and fabricates the 4H-SiC power MOSFET with top oxide and double P-well(TODP-MOSFET)to enhance the single-event radiation tolerance of the gate oxide.Simulation results suggest that the proposed TOD...This work proposes and fabricates the 4H-SiC power MOSFET with top oxide and double P-well(TODP-MOSFET)to enhance the single-event radiation tolerance of the gate oxide.Simulation results suggest that the proposed TODP structure reduces the peak electric field within the oxide and minimizes the sensitive region by more than 70%compared to C-MOSFETs.Experimental results show that the gate degradation voltage of the TODP-MOSFET is higher than that of the C-MOSFET,and the gate leakage current is reduced by 95%compared to the C-MOSFET under heavy-ion irradiation with a linear energy transfer(LET)value exceeding 75 MeV·cm^(2)/mg.展开更多
The integration of large-scale new energy and high-capacity DC transmission leads to a reduction in system inertia.Grid-forming renewable energy sources(GF-RES)has a significant improvement effect on system inertia.Co...The integration of large-scale new energy and high-capacity DC transmission leads to a reduction in system inertia.Grid-forming renewable energy sources(GF-RES)has a significant improvement effect on system inertia.Commutation failure faults may cause a short-term reactive power surplus at the sending end and trigger transient overvoltage,threatening the safe and stable operation of the power grid.However,there is a lack of research on the calculation method of transient overvoltage caused by commutation failure in high-voltage DC transmission systems with grid-forming renewable energy sources integration.Based on the existing equivalent model of highvoltage DC transmission systems at the sending end,this paper proposes to construct a model of the high-voltage DC transmission system at the sending end with grid-forming renewable energy sources.The paper first clarifies the mechanism of overvoltage generation,then considers the reactive power droop control characteristics of GF-RES,and derives the transient voltage calculation model of theDC transmission system with GF-RES integration.It also proposes a calculation method for transient overvoltage at the sending-end converter bus with GF-RES integration.Based on the PSCAD/EMTDC simulation platform,this paper builds an experimental simulation model.By constructing three different experimental scenarios,the accuracy and effectiveness of the proposed transient overvoltage calculation method are verified,with a calculation error within 5%.At the same time,this paper quantitatively analyzes the impact of grid strength,new energy proportion,and rated transmission power on transient overvoltage from three different perspectives.展开更多
Recent various experiments have provided evidence supporting the emergence of loop-current order in kagome metals. Particularly superconductivity in AV_(3)Sb_(5) is significantly enhanced when this charge order is sup...Recent various experiments have provided evidence supporting the emergence of loop-current order in kagome metals. Particularly superconductivity in AV_(3)Sb_(5) is significantly enhanced when this charge order is suppressed by pressure or doping. Distinct from magnetic order, loop-current order does not couple directly to spin and thus whether such fluctuations can enhance superconductivity remains elusive. We design a sign problem-free bilayer kagome model coupled to quantum Ising spins through bond currents and perform determinant quantum Monte Carlo simulations to explore single-particle properties and superconductivity arising from 2 × 2 loopcurrent fluctuations. We find that this loop-current order induces intriguing band folding, band broadening,and gap opening around saddle points. Remarkably, our pairing susceptibility analysis identifies a dominant enhancement of superconductivity due to loop-current fluctuations, with the dominant pairing being the chiral d-wave channel. This pairing primarily occurs within the intra-sublattice channel and involves third nearestneighbor sites, attributed to the unique sublattice texture associated with van Hove singularities. We also discuss potential experimental implications for kagome superconductors.展开更多
Magnon spin currents in insulating magnets are useful for low-power spintronics. However, in magnets stacked by antiferromagnetic(AFM) exchange coupling, which have recently aroused significant interest for potential ...Magnon spin currents in insulating magnets are useful for low-power spintronics. However, in magnets stacked by antiferromagnetic(AFM) exchange coupling, which have recently aroused significant interest for potential applications in spintronics, Bose–Einstein distribution populates magnon states across all energies from opposite eigenmodes, and hence the magnon spin current is largely compensated. Contrary to this common observation,here, we show that magnets with X-type AFM stacking, where opposite magnetic sublattices form orthogonal intersecting chains, support giant magnon spin currents with minimal compensation. Our model Hamiltonian calculations predict magnetic chain locking of magnon spin currents in these X-type magnets, significantly reducing their compensation ratio. In addition, the one-dimensional nature of the chain-like magnetic sublattices enhances magnon spin conductivities surpassing those of two-dimensional ferromagnets and canonical altermagnets. Notably, uncompensated X-type magnets, such as odd-layer antiferromagnets and ferrimagnets, can exhibit magnon spin currents polarized opposite to those expected by their net magnetization. These unprecedented properties of X-type magnets, combined with their inherent advantages resulting from AFM coupling, offer a promising new path for low-power high-performance spintronics.展开更多
Background Pain sensitivity is critical for preventing non-suicidal self-injury(NSSI)behaviours;however,individuals engaging in such behaviours often exhibit decreased pain sensitivity,which may undermine this natural...Background Pain sensitivity is critical for preventing non-suicidal self-injury(NSSI)behaviours;however,individuals engaging in such behaviours often exhibit decreased pain sensitivity,which may undermine this natural safeguard.The dorsolateral prefrontal cortex(DLPFC)is a key region involved in pain regulation,and recent approaches using transcranial direct current stimulation(tDCS)to target the DLPFC have shown potential for modulating pain processing and restoring normal pain perception for individuals engaging in NSSI behaviours.Aims This study aimed to explore the immediate and short-term effects of a single session of tDCS on pain sensitivity in individuals with NSSI,as well as its secondary effects on mood and NSSI-related factors.Methods In this randomised,double-blind,parallel,sham-controlled clinical trial,participants with a history of NSSI were randomly assigned to receive either active or sham tDCS.The intervention consisted of a single 20 min tDCS session targeting the left DLPFC.The primary outcome was pain sensitivity,measured by the pressure pain threshold(PPT)and heat pain score(HPS).Secondary and additional outcomes included NSSI urges,NSSI resistance,self-efficacy in resisting NSSI,mood-related variables and exploratory cognitive-affective processes such as rumination,self-criticism and self-perceived pain sensitivity,assessed at baseline,immediately post-intervention,and at 24 hours,1 week and 2 weeks follow-ups.Results For the primary outcomes,no significant differences between groups were observed for pain sensitivity(PPT,padj=0.812;HPS,padj=0.608).However,an exploratory sensitivity analysis treating each trial as an individual observation revealed a significant effect on HPS(padj=0.036).For the secondary and additional outcomes,although there were initial improvements in joyful feelings and reductions in negative affect at 2 weeks post-intervention,these effects did not remain significant after multiple comparison corrections.Notably,reductions in rumination were statistically significant at both 1-week and 2-week follow-ups(1 week,p_(adj)=0.040;2 weeks,p_(adj)=0.042).There were no significant effects on NSSI urges,NSSI resistance,self-efficacy in resisting NSSI or self-criticism.Conclusions A single session of tDCS over the left DLPFC did not produce significant changes in pain sensitivity in individuals with NSSI.A sensitivity analysis indicated an effect on heat pain sensitivity,possibly reflecting changes in brain activity,warranting confirmation through neuroimaging.These findings suggest that tDCS warrants further investigation for its potential to influence pain-related cognitive-affective processes in individuals with NSSI.展开更多
基金National Key Research and Development Program of China(2021YFB3700801)。
文摘Low-density short-duration pulsed current-assisted aging treatment was applied to the Ti-6Al-4V-0.5Mo-0.5Zr alloy subjected to different solution treatments.The results show that numerous α_(p) phases redissolve into the new β phase during the pulsed current-assisted aging process,and then the newly formed β phase is mainly transformed into the β_(t) phase,with occasional transition to new α_(p) phase,leading to a remarkable grain refinement,especially for the lamellarαs phases.In comparison to conventional aging treatment,the pulsed current-assisted aging approach achieves a significant enhancement in strength without degrading ductility,yielding an excellent mechanical property combination:a yield strength of 932 MPa,a tensile strength of 1042 MPa,and an elongation of 12.2%.It is primarily ascribed to the increased fraction of β_(t) phases,the obvious grain refinement effect,and the slip block effect induced by the multiple-variantαs colonies distributed within β_(t) phases.
基金Supported by the Fundamental Research Funds for the Central Universities(2024ZYGXZR047)the National Natural Science Foundation of China(62373156)the Guangdong Basic and Applied Basic Research Foundation(2024A1515011736)。
文摘This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.
基金financial support from the Helmholtz Association and the German Federal Ministry of Education and Research(BMBF)within the ExcellBattUlm project(03XP0257D)the HighSafe-3 project(03XP0568A)。
文摘Energy density and safety are two crucial parameters when evaluating lithium-metal batteries(LMBs).Herein,we present an ultralight polymer-based current collector,incorporating flame-retardant materials,designed specifically for thin lithium-metal anodes.Compared to the traditional copper current collector(8.96 mg cm^(-2),10μm thick),the polymer-based current collector(12μm thick)has a significantly lower areal density of 1.41 mg cm^(-2),i.e.,only one-sixth of the copper collector,thus enabling substantially higher energy densities.Accordingly,when employed in Li||NMC_(622)full-cells,the polymer-based current collector enables a specific energy of 449 Wh kg^(-1),representing a notable improvement of about14.5%compared to cells employing a classic copper current collector.The inclusion of Al(OH)_(3) as a flame retardant into the current collector suppresses flammability and,thereby,significantly improves the safety of the resulting LMBs.
基金supported by the National Natural Science Foundation of China(grant numbers 52071225,22179143,and 22002176)the European Union’s Horizon Europe research and innovation program Electron Beam Emergent Additive Manufacturing(EBEAM)(grant number 101087143)+2 种基金a Norway Grant through the National Science Centre(project number 2019/34/H/ST8/00547)the National Key R&D Program of China(grant number 2021YFB3800300)the Jiangsu Funding Program for Excellent Postdoctoral Talent。
文摘Lithium metal batteries(LMBs)are promising candidates for next-generation high-energy-density storage devices.However,an unstable lithium metal anode poses significant issues that critically compromise battery safety and cycle life,including lithium dendrite formation,solid electrolyte interphase degradation,dead lithium accumulation,and substantial volume fluctuations during cycling.These problems can be addressed by regulating lithium deposition and suppressing side reactions through the modification of copper current collectors using three classes of materials:metal and metal oxide,carbon,and polymer materials.This review comprehensively examines recent advances in the application of these materials as current collector coatings.Particularly,their distinct roles in the lithium deposition process are analyzed to understand how they mitigate the issues associated with the lithium metal anode.Furthermore,their inherent limitations are considered to inform future research directions.While each class of materials offers specific advantages,multifunctionality is required to effectively regulate lithium deposition.In prospect,a novel composite copper current collector design that integrates the merits of the aforementioned advanced materials is proposed.The insights from this review provide valuable guidance for the rational design of modified copper current collectors,which would significantly improve the safety and cycle life of LMBs and advance their commercialization.
基金funded by State Grid Corporation of China,grant number DQ30DK24001L。
文摘When the converter bus voltage of a voltage source converter-based high voltage direct current(VSC-HVDC)system drops below a certain predetermined threshold,the system enters low-voltage ride-through(LVRT)mode to avoid overcurrent and potential equipment failure,during which it operates as a controlled current source.The influence mechanism of LVRT control strategies on short-circuit current and overall system stability remains not yet fully and systematically investigated.First,this paper provides an overview of several LVRT strategies for VSC-HVDC systems and examines their effects on short-circuit current contribution.Next,it analyzes in detail the mechanisms through which active and reactive currents injected during LVRT impact system frequency stability,voltage stability,and synchronization stability.To address these interrelated issues,an optimized and comprehensive LVRT strategy incorporating short-circuit current constraints is proposed.The approach determines the active current ratio based on system frequency stability requirements and dynamically adjusts the active current recovery rate via phase control of the VSC-HVDC bus.The remaining capacity is allocated to reactive current support,thereby enhancing voltage and synchronization stability while maintaining sufficient short-circuit current margin and system frequency stability.Finally,simulations conducted on the PSS/E platform,using actual grid data from a selected cross-section system,validate convincingly the effectiveness of the proposed parameter optimization strategy for VSC-HVDC low-voltage ride-through.
文摘With the advent of the big data era,modern statistics has enjoyed unprecedented development opportunities and also faced numerous new challenges.Traditional statistical computing methods are often limited by issues such as computer memory capacity and distributed storage of data across different locations,and are unable to directly apply to large-scale data sets.Therefore,in the context of big data,designing efficient and theoretically guaranteed statistical learning and inference algorithms has become a key issue that the current field of statistics urgently needs to address.In this paper,the application status of statistical analysis methods in the big data environment was systematically reviewed,and its future development directions were analyzed to provide reference and support for the further development of theory and methods of the statistical analysis of big data.
文摘Transcranial direct current stimulation(tDCS)is a non-invasive technique that modifies cortical excitability and induces neuroplasticity using low-intensity electrical currents.Nuclear medicine technologies like positron emission tomography(PET)and single-photon emission computed tomography(SPECT)can quantify cerebral metabolism and other dynamics.Evidence suggests that combining tDCS with these imaging methods enhances understanding and outcomes for neurological and psychiatric conditions.This review highlights how nuclear medicine can objectively characterize tDCS eff ects,map network modulation,and identify predictive biomarkers.PET and SPECT indicate changes in glucose metabolism and neurotransmitter activity post-tDCS,demonstrating their value in validation.While the co-application of these methodologies is still in conceptual stages,their integration may advance precision neuromodulation and inform rehabilitation strategies.
基金supported by the National Natural Science Foundation of China under Grant 52277184 and Grant 52277183.
文摘The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited attention paid to the impacts of control loop dynamics.However,the complex control dynamics,especially the interactions between the active/reactive power control loops and the current saturation process(CSP),are crucial for accurately describing the transient behavior and evaluating the stability.Thus,in this study,a new large-signal GFMC model is established,considering the reactive power control(RPC)with different kinds of controllers and the CSP simultaneously.It is revealed that GFMC does not switch to the current-limited mode immediately,and the dynamics of RPC further affect the transient behavior before the current limiting significantly.Hence,the complex control dynamics can alter the mode switching point of current saturation,thereby increasing the risk of loss of synchronization(LOS).Based on the above findings,comprehensive comparisons of typical RPC controllers are presented to facilitate practical engineering applications.A unified stability enhancement method is proposed for solving the problem of LOS.Finally,experiments validate the correctness of the analysis and the effectiveness of the proposed control strategy.
基金supported by Natural Science Foundation of Wuhan(2024040701010051)Natural Science Foundation of Hubei(2023AFB111)and National Natural Science Foundation of China(52401108).
文摘To elucidate the accelerated degradation mechanisms of metallic interconnects in operational solid oxide fuel cells,the oxidation behavior of FSS430 ferritic stainless steel under the coupling of simultaneous electrical current and high-temperature exposure is investigated.Isothermal thermogravimetric analysis was employed to quantify oxidation kinetics,complemented by microstructural characterization using X-ray diffraction,scanning electron microscopy with energy-dispersive spectroscopy and transmission electron microscopy.Experimental results demonstrate that the applied current dramatically enhances oxidation rates,increasing specific mass gain from 0.25 mg/cm^(2)(0 A/cm^(2))to 5.20 mg/cm^(2)(0.2 A/cm^(2))and oxide scale thickness from 1.87 to 15.62μm after 200 h.This acceleration originates from current-induced electromigration forces that promote cationic transport through the oxide layer.The quantitative relationships between current density and oxidation parameters are established,enabling predictive modeling of interconnector degradation in solid oxide fuel cell(SOFC)systems.
文摘Exercise produces a decrease in pain sensitivity via an effect called exercise-induced hypoalgesia(EIH).Transcranial direct current stimulation(tDCS),acting on similar analgesic mechanisms as EIH,represents a potential complementary intervention that may amplify the effects of exercise on pain.This study aimed to explore if anodal tDCS could enhance the effect of exercise on pain compared to exercise alone.A total of 35 healthy participants aged 19–37 years completed a familiarisation session followed by two separate sessions where active and sham tDCS was applied in a randomised cross-over design.The familiarisation session involved familiarisation to the pain assessment and exercise tasks,while the subsequent tDCS sessions involved pain sensitivity assessment,exercise and either anodal tDCS or sham tDCS.tDCS doses were applied at 2 mA over the primary motor cortex for 10 min,with the reference electrode placed over the contralateral supraorbital area.The exercise task involved a sustained isometric grip strength contraction at 35%of maximal voluntary contraction(MVC)until volitional exhaustion.Pain sensitivity was evaluated as pressure pain threshold before tDCS,after tDCS,and after exercise.Across both tDCS conditions,pain threshold was higher after exercise when compared to pre-and post-tDCS measurement.This increase in pain threshold did not differ between active and sham tDCS conditions.Our findings suggest that the hypoalgesic effects of active anodal tDCS over the motor cortex prior to exercise are no greater than the effects of sham tDCS prior to exercise.
基金funded by Youth Talent Growth Project of Guizhou Provincial Department of Education(No.Qianjiaoji[2024]21)National Natural Science Foundation of China(No.62461008 and No.52507211)Guizhou Provincial Key Technology R&D Program(No.[2024]General 049).
文摘To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distribution networks,this paper adopts a component sharing mechanism to propose a composite multi-port hybrid DC circuit breaker(CM-HCB)with DC power flow and fault current limitation abilities,as well as reduced component costs.The proposed CM-HCB topology enables the sharing of the main breaker branch(MB)and the energy dissipation branch,while the load commutation switches(LCSs)in the main branch are reused as power flow control components,enabling flexible regulation of power flow in multiple lines.Meanwhile,by reconstructing the current path during the fault process,the proposed CM-HCB can utilize the internal coupled inductor to limit the current rise rate at the initial stage of the fault,significantly reducing the requirement for breaking current.A detailed study on the topological structure,steady-state power flow regulation mechanism,transient fault isolation mechanism,control strategy and characteristic analysis of the proposed CM-HCB is presented.Then,a Matlab/Simulink-based meshed three-terminal DC grid simulation platform with the proposed CM-HCB is built.The results indicate that the proposed CM-HCB can not only achieve flexible power flow control during steady-state operation,but also obtain current rise limitation and fault isolation abilities under short-circuit fault conditions,verifying its correctness and effectiveness.Finally,a comparative economic analysis is conducted between the proposed CM-HCB and the other two existing solutions,confirming that its component sharing mechanism can significantly reduce the number of components,lower system costs,and improve component utilization.
基金supported by the National Natural Science Foundation of China(No.52477195,No.U25B20204,No.52437009).
文摘Virtor(VSG)technology is widely investigated and applied for dual synchronous generatoubly-fed induction generators(DFIGs)to provide virtual inertia.However,under grid faults,the conventional VSG-based DFIG faces challenges of transient overcurrent and instability.The critical limitation for grid-forming DFIGs to withstand serious grid faults is the rotor-side converter(RSC)’s inability to quickly generate proper rotor voltage to counteract transient electromotive force(EMF),which results in transient overcurrent and damage to the RSC.To fill this gap,this study introduces a novel low-voltage ride-through(LVRT)control strategy for the grid-forming DFIG under symmetrical grid fault conditions.To mitigate transient overcurrent,the core mechanism is to regulate the rotor flux linkage to align with the stator flux linkage in an optimal proportion.Under the proposed control strategy,both post-fault rotor current and required rotor voltage are constrained within operational limits.Moreover,fluctuations in electromagnetic torque are efficiently suppressed during grid disturbances.Consequently,the dynamic stability and power support capacity of the DFIG system remain intact throughout the transient process.Finally,simulation studies and experimental results are provided to verify the feasibility of the proposed approach.
基金supported in part by Natural Science Foundation of Jiangsu Province under Grant BK20230255Natural Science Foundation of Shandong Province under Grant ZR2023QE281.
文摘The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract.
基金funding from the European Union’s Horizon 2020 research and innovation program through the European IMPULSE project under Grant Agreement No.871161from LASERLAB-EUROPE V under Grant Agreement No.871124+6 种基金from the Grant Agency of the Czech Republic(Grant No.GM23-05027M)Grant No.PDC2021120933-I00 funded by MCIN/AEI/10.13039/501100011033by the European Union Next Generation EU/PRTRsupported by funding from the Ministerio de Ciencia,Innovación y Universidades in Spain through ICTS Equipment Grant No.EQC2018-005230-Pfrom Grant No.PID2021-125389O A-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER,UEby“ERDF A Way of Making Europe”by the European Unionfrom grants of the Junta de Castilla y León with Grant Nos.CLP263P20 and CLP087U16。
文摘This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven secondary sources,taking as an example ion acceleration by target normal sheath acceleration.The Pearson linear correlation of maximum return current amplitude and proton spectrum cutoff energy is found to be in the range from~0.70 to 0.94.kA-scale return currents rise in all interaction schemes where targets of any kind are charged by escaping laser-accelerated relativistic electrons.Their precise measurement is demonstrated using an inductive scheme that allows operation at high repetition rates.Thus,return currents can be used as a metrological online tool for the optimization of many laser-driven secondary sources and for diagnosing their stability.In particular,in two parametric studies of laser-driven ion acceleration,we carry out a noninvasive online measurement of return currents in a tape target system irradiated by the 1 PW VEGA-3 laser at Centro de Láseres Pulsados:first the size of the irradiated area is varied at best compression of the laser pulse;second,the pulse duration is varied by means of induced group delay dispersion at best focus.This work paves the way to the development of feedback systems that operate at the high repetition rates of PW-class lasers.
基金supported by the Guangdong Basic and Applied Basic Research Foundation(No.2023B1515120030).
文摘The rapid-cycling synchrotron(RCS)is a crucial device for proton beam acceleration at the China Spallation Neutron Source,operating at a repetition frequency of 25 Hz.The beam power was increased from 100 kW to 140 kW.This increase makes the on-orbit beam more sensitive to disturbances in various parts of the accelerator,including the RCS magnet power supply system.This paper presents a method for reducing the high-order harmonic current error in resonant power supplies for dipole magnets and examines its impact on the horizontal orbit offset of the beam.It adopts a control scheme that combines high-order harmonic current compensation with PI double-loop control of the resonant power supply.By utilizing the existing digital controller hardware in the RCS power supply system,this study demonstrates how to achieve precise control of the 50 Hz harmonic current output in a cost-effective manner.Ultimately,it enhances performance by reducing the current error by up to 50%and provides methodological support for future upgrades to the power supply system.Such improvements enhance the stability of the RCS,reducing the beam horizontal orbit deviation by at least 19.8%.
基金supported by the Joint Funds of the National Natural Science Foundation of China(Grant No.U2341220)the Hefei Comprehensive National Science Center。
文摘This work proposes and fabricates the 4H-SiC power MOSFET with top oxide and double P-well(TODP-MOSFET)to enhance the single-event radiation tolerance of the gate oxide.Simulation results suggest that the proposed TODP structure reduces the peak electric field within the oxide and minimizes the sensitive region by more than 70%compared to C-MOSFETs.Experimental results show that the gate degradation voltage of the TODP-MOSFET is higher than that of the C-MOSFET,and the gate leakage current is reduced by 95%compared to the C-MOSFET under heavy-ion irradiation with a linear energy transfer(LET)value exceeding 75 MeV·cm^(2)/mg.
基金supported by Key Natural Science Research Projects of Colleges and Universities in Anhui Province(2022AH051831).
文摘The integration of large-scale new energy and high-capacity DC transmission leads to a reduction in system inertia.Grid-forming renewable energy sources(GF-RES)has a significant improvement effect on system inertia.Commutation failure faults may cause a short-term reactive power surplus at the sending end and trigger transient overvoltage,threatening the safe and stable operation of the power grid.However,there is a lack of research on the calculation method of transient overvoltage caused by commutation failure in high-voltage DC transmission systems with grid-forming renewable energy sources integration.Based on the existing equivalent model of highvoltage DC transmission systems at the sending end,this paper proposes to construct a model of the high-voltage DC transmission system at the sending end with grid-forming renewable energy sources.The paper first clarifies the mechanism of overvoltage generation,then considers the reactive power droop control characteristics of GF-RES,and derives the transient voltage calculation model of theDC transmission system with GF-RES integration.It also proposes a calculation method for transient overvoltage at the sending-end converter bus with GF-RES integration.Based on the PSCAD/EMTDC simulation platform,this paper builds an experimental simulation model.By constructing three different experimental scenarios,the accuracy and effectiveness of the proposed transient overvoltage calculation method are verified,with a calculation error within 5%.At the same time,this paper quantitatively analyzes the impact of grid strength,new energy proportion,and rated transmission power on transient overvoltage from three different perspectives.
基金supported by the National Natural Science Foundation of China (Grant No. 12447103)financial support from the MERIT-WINGS course provided by the University of Tokyo+10 种基金the Fellowship for Integrated Materials Science and Career Development provided by the Japan Science and Technology Agencysupport from the computational resource of Wisteria/BDEC-01 provided by Information Technology Center, the University of Tokyo, for the Monte Carlo simulationthe support by the National Natural Science Foundation of China (Grant No. 12404275)the Fundamental Research Program of Shanxi Province (Grant No. 202403021212015)support from the Würzburg-Dresden Cluster of Excellence on Complexity and Topology in Quantum Matter-ct.qmat (EXC 2147, Project No. 390858490)supported by the National Natural Science Foundation of China (Grant No. 12274289)the National Key R&D Program of China (Grant Nos. 2022YFA1402702 and 2021YFA1401400)the Innovation Program for Quantum Science and Technology (Grant No. 2021ZD0301902)Yangyang Development Fund, and Startup Funds from SJTUsupported by the National Key R&D Program of China (Grant No. 2023YFA1407300)the National Natural Science Foundation of China (Grant No. 12047503)。
文摘Recent various experiments have provided evidence supporting the emergence of loop-current order in kagome metals. Particularly superconductivity in AV_(3)Sb_(5) is significantly enhanced when this charge order is suppressed by pressure or doping. Distinct from magnetic order, loop-current order does not couple directly to spin and thus whether such fluctuations can enhance superconductivity remains elusive. We design a sign problem-free bilayer kagome model coupled to quantum Ising spins through bond currents and perform determinant quantum Monte Carlo simulations to explore single-particle properties and superconductivity arising from 2 × 2 loopcurrent fluctuations. We find that this loop-current order induces intriguing band folding, band broadening,and gap opening around saddle points. Remarkably, our pairing susceptibility analysis identifies a dominant enhancement of superconductivity due to loop-current fluctuations, with the dominant pairing being the chiral d-wave channel. This pairing primarily occurs within the intra-sublattice channel and involves third nearestneighbor sites, attributed to the unique sublattice texture associated with van Hove singularities. We also discuss potential experimental implications for kagome superconductors.
基金supported by the National Key R&D Program of China (Grant No.2022YFA1403203)the National Natural Science Funds for Distinguished Young Scholar (Grant No.52325105)+2 种基金the National Natural Science Foundation of China (Grant Nos.12274411,12241405,52250418,and12404185)the Basic Research Program of the Chinese Academy of Sciences (CAS) Based on Major Scientific Infrastructures (Grant No.JZHKYPT-2021-08)the CAS Project for Young Scientists in Basic Research (Grant No.YSBR-084)。
文摘Magnon spin currents in insulating magnets are useful for low-power spintronics. However, in magnets stacked by antiferromagnetic(AFM) exchange coupling, which have recently aroused significant interest for potential applications in spintronics, Bose–Einstein distribution populates magnon states across all energies from opposite eigenmodes, and hence the magnon spin current is largely compensated. Contrary to this common observation,here, we show that magnets with X-type AFM stacking, where opposite magnetic sublattices form orthogonal intersecting chains, support giant magnon spin currents with minimal compensation. Our model Hamiltonian calculations predict magnetic chain locking of magnon spin currents in these X-type magnets, significantly reducing their compensation ratio. In addition, the one-dimensional nature of the chain-like magnetic sublattices enhances magnon spin conductivities surpassing those of two-dimensional ferromagnets and canonical altermagnets. Notably, uncompensated X-type magnets, such as odd-layer antiferromagnets and ferrimagnets, can exhibit magnon spin currents polarized opposite to those expected by their net magnetization. These unprecedented properties of X-type magnets, combined with their inherent advantages resulting from AFM coupling, offer a promising new path for low-power high-performance spintronics.
基金supported by National Natural Science Foundation of China(82471564)YT is supported by National Natural Science Foundation of China(32322035,32171078).
文摘Background Pain sensitivity is critical for preventing non-suicidal self-injury(NSSI)behaviours;however,individuals engaging in such behaviours often exhibit decreased pain sensitivity,which may undermine this natural safeguard.The dorsolateral prefrontal cortex(DLPFC)is a key region involved in pain regulation,and recent approaches using transcranial direct current stimulation(tDCS)to target the DLPFC have shown potential for modulating pain processing and restoring normal pain perception for individuals engaging in NSSI behaviours.Aims This study aimed to explore the immediate and short-term effects of a single session of tDCS on pain sensitivity in individuals with NSSI,as well as its secondary effects on mood and NSSI-related factors.Methods In this randomised,double-blind,parallel,sham-controlled clinical trial,participants with a history of NSSI were randomly assigned to receive either active or sham tDCS.The intervention consisted of a single 20 min tDCS session targeting the left DLPFC.The primary outcome was pain sensitivity,measured by the pressure pain threshold(PPT)and heat pain score(HPS).Secondary and additional outcomes included NSSI urges,NSSI resistance,self-efficacy in resisting NSSI,mood-related variables and exploratory cognitive-affective processes such as rumination,self-criticism and self-perceived pain sensitivity,assessed at baseline,immediately post-intervention,and at 24 hours,1 week and 2 weeks follow-ups.Results For the primary outcomes,no significant differences between groups were observed for pain sensitivity(PPT,padj=0.812;HPS,padj=0.608).However,an exploratory sensitivity analysis treating each trial as an individual observation revealed a significant effect on HPS(padj=0.036).For the secondary and additional outcomes,although there were initial improvements in joyful feelings and reductions in negative affect at 2 weeks post-intervention,these effects did not remain significant after multiple comparison corrections.Notably,reductions in rumination were statistically significant at both 1-week and 2-week follow-ups(1 week,p_(adj)=0.040;2 weeks,p_(adj)=0.042).There were no significant effects on NSSI urges,NSSI resistance,self-efficacy in resisting NSSI or self-criticism.Conclusions A single session of tDCS over the left DLPFC did not produce significant changes in pain sensitivity in individuals with NSSI.A sensitivity analysis indicated an effect on heat pain sensitivity,possibly reflecting changes in brain activity,warranting confirmation through neuroimaging.These findings suggest that tDCS warrants further investigation for its potential to influence pain-related cognitive-affective processes in individuals with NSSI.