When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ a...When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ and the inside pressure changed about 14.6 Kpa, when the pottery soil was replaced by the sealing plug. When the soil water was relatively stable in the experimental salvers, the in-side pressure stil varied regularly with the temperature. When the inside temperature increased by 22.2 ℃, the inside pressure varied about 7.4 Kpa. Through com-pensation calculation of the inside tension, the temperature in the warming and cooling periods was compensated, which was useful to correct the tension measurement errors induced from the changing temperature. When the measuring interval was 4 hours and the temperature difference was 18.1 ℃, the tension difference of both points was only 0.278 Kpa, compared to the difference up to 6.5 Kpa before compensation.展开更多
Correction to“Liu QQ,Li YD,Chen JX,Zhang LL,Guan RC,Zhao W,Meng LY.Prognostic value of preoperative fibrinogen,neutrophil-to-lymphocyte ratio,serum alpha-fetoprotein,and prealbumin for patients with primary liver can...Correction to“Liu QQ,Li YD,Chen JX,Zhang LL,Guan RC,Zhao W,Meng LY.Prognostic value of preoperative fibrinogen,neutrophil-to-lymphocyte ratio,serum alpha-fetoprotein,and prealbumin for patients with primary liver cancer undergoing transarterial chemoembolization.World J Gastrointest Oncol 2025;17(6):103198 PMID:40547171 DOI:10.4251/wjgo.v17.i6.103198”.The funding number listed in the"Supported by"section of this article needs to be corrected.展开更多
基金Supported by Jiangsu Agricultural Self-innovation Fund[CX(13)3031]~~
文摘When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ and the inside pressure changed about 14.6 Kpa, when the pottery soil was replaced by the sealing plug. When the soil water was relatively stable in the experimental salvers, the in-side pressure stil varied regularly with the temperature. When the inside temperature increased by 22.2 ℃, the inside pressure varied about 7.4 Kpa. Through com-pensation calculation of the inside tension, the temperature in the warming and cooling periods was compensated, which was useful to correct the tension measurement errors induced from the changing temperature. When the measuring interval was 4 hours and the temperature difference was 18.1 ℃, the tension difference of both points was only 0.278 Kpa, compared to the difference up to 6.5 Kpa before compensation.
基金Supported by Health Commission of Heilongjiang Province,No.20230404080031.
文摘Correction to“Liu QQ,Li YD,Chen JX,Zhang LL,Guan RC,Zhao W,Meng LY.Prognostic value of preoperative fibrinogen,neutrophil-to-lymphocyte ratio,serum alpha-fetoprotein,and prealbumin for patients with primary liver cancer undergoing transarterial chemoembolization.World J Gastrointest Oncol 2025;17(6):103198 PMID:40547171 DOI:10.4251/wjgo.v17.i6.103198”.The funding number listed in the"Supported by"section of this article needs to be corrected.