Superconducting kinetic inductance detectors(KIDs)are considered to be a highly promising technique for the large-scale imaging of millimeter and submillimeter waves in astronomy.As the pixel density and the array siz...Superconducting kinetic inductance detectors(KIDs)are considered to be a highly promising technique for the large-scale imaging of millimeter and submillimeter waves in astronomy.As the pixel density and the array size increase,the electromagnetic crosstalk inevitably becomes a problem that prevents increasing the multiplexing during the development of larger KIDs arrays.In this work,an effective method is introduced to suppress the electromagnetic crosstalk and achieve a compact pixel distribution and small frequency intervals.The electromagnetic crosstalk is first analyzed by simulating the behavior of two neighboring pixels,and the physical distance and the frequency interval are optimized.Then,the arrangement of the pixels on the whole array is redesigned using a genetic algorithm to satisfy the requirements.The simulation results reveal that the normalized electromagnetic crosstalk can be reduced to 0.5%on an 8×8 array.Larger arrays of 16×16 pixels have been fabricated and measured to validate this method,and the results reveal that both the resonance property and survival rate of pixels are improved effectively with this method.This method will be very helpful for designing high-multiplexing KIDs arrays within a limited bandwidth.展开更多
For permanent magnet synchronous machines(PMSMs),accurate inductance is critical for control design and condition monitoring.Owing to magnetic saturation,existing methods require nonlinear saturation model and measure...For permanent magnet synchronous machines(PMSMs),accurate inductance is critical for control design and condition monitoring.Owing to magnetic saturation,existing methods require nonlinear saturation model and measurements from multiple load/current conditions,and the estimation is relying on the accuracy of saturation model and other machine parameters in the model.Speed harmonic produced by harmonic currents is inductance-dependent,and thus this paper explores the use of magnitude and phase angle of the speed harmonic for accurate inductance estimation.Two estimation models are built based on either the magnitude or phase angle,and the inductances can be from d-axis voltage and the magnitude or phase angle,in which the filter influence in harmonic extraction is considered to ensure the estimation performance.The inductances can be estimated from the measurements under one load condition,which is free of saturation model.Moreover,the inductance estimation is robust to the change of other machine parameters.The proposed approach can effectively improve estimation accuracy especially under the condition with low current magnitude.Experiments and comparisons are conducted on a test PMSM to validate the proposed approach.展开更多
To advance the theoretical understanding,technological development,and field application of electric charge induction for monitoring rock deformation and failure,this study investigates the induced electric charge gen...To advance the theoretical understanding,technological development,and field application of electric charge induction for monitoring rock deformation and failure,this study investigates the induced electric charge generated during the deformation and failure of igneous rocks.The charge originates mainly from a combination of electrical polarization and triboelectric effects.Through laboratory experiments,we analyzed the time-frequency evolution of induced electric charge signals and identified relevant monitoring parameters.An online downhole electric charge induction monitoring system was developed and validated in the field.Experimental results show that the dominant frequency range of induced electric charge signals generated during igneous rock deformation and failure lies between 0 and 23 Hz,and a low-pass finite impulse response(FIR)filter effectively suppresses noise.Optimal sensor distances for monitoring cubic and cylindrical specimens were determined to be 17 mm and 13 mm,respectively.We proposed early warning indicators,including the maximum absolute value of the induced electric charge,the arithmetic mean value,the distribution dispersion coefficient,and the cumulative sum value.In field application,time-domain curves and spatial distribution charts of these warning indicators correspond well with changes in abutment stress ahead of the mining face,offering indirect insights into local stress evolution.This research provides technical and equipment support for the application of electric charge induction technology to monitoring and early warning of coal bursts.展开更多
BACKGROUND The use of induction immunosuppression agents has improved kidney transplant outcomes,but selecting the optimal agent remains a point of debate.AIM To compare the long-term outcomes of kidney transplant rec...BACKGROUND The use of induction immunosuppression agents has improved kidney transplant outcomes,but selecting the optimal agent remains a point of debate.AIM To compare the long-term outcomes of kidney transplant recipients receiving alemtuzumab vs basiliximab induction,focusing on graft function,acute rejection,infection,malignancy,post-transplant glomerulonephritis,and survival,using a propensity score matched cohort design.METHODS Kidney transplant recipients who received alemtuzumab or basiliximab induction from 2014 to 2019 across two nephrology centres in Northwest England were evaluated.Propensity score matching at a 1:1.5 ratio ensured comparability between cohorts.Baseline characteristics,immunosuppression regimens,and outcomes were analyzed.Linear,binary logistic and Cox proportional hazard regression models.RESULTS A total of 436 recipients were included,with a median follow-up of 5.2 years.The matched cohort(n=262)had a mean age of 51.1±13.5 years;39%were female and 92%were white.There was no significant difference in the cumulative incidence of acute rejection[odds ratio(OR)=2.10;95%CI:0.9-4.9;P=0.110].Compared with basiliximab,alemtuzumab was associated with lower estimated glomerular filtration rate at 12 months(-6.6 mL/minute/1.73 m2;95%CI:-10.5 to-2.7;P<0.001)and higher risks of cytomegalovirus viremia(OR=3.2;95%CI:1.6-6.5;P<0.001),BK viremia(OR=2.4;95%CI:1.1-5.5;P=0.02),post-transplant malignancy(OR=6.2;95%CI:1.6-29.9;P=0.013),and death-censored graft loss(hazard ratio=3.6;95%CI:1.2-11.4;P=0.03).No significant differences were observed in post-transplant glomerulonephritis or recipient mortality.CONCLUSION In this propensity score-matched analysis,alemtuzumab induction was associated with lower graft function at 12 months and higher risks of viral infection,post-transplant malignancy,and graft loss compared with basiliximab.These findings highlight the need for further studies to confirm the long-term safety and effectiveness of alemtuzumab in kidney transplantation.展开更多
Improving plasma uniformity is a critical issue in the development of large-area radio-frequency(RF)inductively coupled plasma(ICP)sources.In this work,the effects of coil structure and electromagnetic shielding on th...Improving plasma uniformity is a critical issue in the development of large-area radio-frequency(RF)inductively coupled plasma(ICP)sources.In this work,the effects of coil structure and electromagnetic shielding on the spatial distribution and uniformity of the plasma are systematically investigated using a three-dimensional fluid model.The model integrates plasma and electromagnetic field modules to simulate the discharge characteristics of a large-area RF ICP source with dimensions of 100 cm×50 cm.The results reveal that the electron density distribution varies significantly with the coil structure.For the rotating and translating coil structures,the electron density is high at off-axis positions and low at the center.In contrast,the mirror coil structure exhibits a significantly higher electron density at the chamber center,resulting in a high-center and low-edge density distribution.Among the three configurations,the rotating coil structure provides the best plasma uniformity.The incorporation of electromagnetic shielding further improves plasma uniformity,particularly for the mirror coil structure.For the rotating and translating coil structures,the electron density exhibits a saddle-shaped distribution regardless of electromagnetic shielding.However,introducing electromagnetic shielding into the mirror coil structure reduces the electron density at the chamber center and decreases the non-uniformity degree by 18.4%.Overall,the mirror coil structure with electromagnetic shielding achieves the highest uniformity,with an exceptional plasma uniformity of 94%.This work offers valuable insights for the design of large-area ICP sources in advanced plasma processing systems.展开更多
To ensure an uninterrupted power supply,mobile power sources(MPS)are widely deployed in power grids during emergencies.Comprising mobile emergency generators(MEGs)and mobile energy storage systems(MESS),MPS are capabl...To ensure an uninterrupted power supply,mobile power sources(MPS)are widely deployed in power grids during emergencies.Comprising mobile emergency generators(MEGs)and mobile energy storage systems(MESS),MPS are capable of supplying power to critical loads and serving as backup sources during grid contingencies,offering advantages such as flexibility and high resilience through electricity delivery via transportation networks.This paper proposes a design method for a 400 V–10 kV Dual-Winding Induction Generator(DWIG)intended for MEG applications,employing an improved particle swarmoptimization(PSO)algorithmbased on a back-propagation neural network(BPNN).A parameterized finite element(FE)model of the DWIG is established to derive constraints on its dimensional parameters,thereby simplifying the optimization space.Through sensitivity analysis between temperature rise and electromagnetic loss of the DWIG,the main factors influencing the machine’s temperature are identified,and electromagnetic loss is determined as the optimization objective.To obtain an accurate fitting function between electromagnetic loss and dimensional parameters,the BPNN is employed to predict the nonlinear relationship between the optimization objective and the parameters.The Latin hypercube sampling(LHS)method is used for random sampling in the FE model analysis for training,testing,and validation,which is then applied to compute the cost function in the PSO.Based on the relationships obtained by the BPNN,the PSO algorithm evaluates the fitness and cost functions to determine the optimal design point.The proposed optimization method is validated by comparing simulation results between the initial design and the optimized design.展开更多
Kidney transplantation(KT)accounts for nearly three-fourths of organ transplants in India,with living donors contributing to 82%of cases.Induction immunosuppression is essential to optimize initial immunosuppression,r...Kidney transplantation(KT)accounts for nearly three-fourths of organ transplants in India,with living donors contributing to 82%of cases.Induction immunosuppression is essential to optimize initial immunosuppression,reduce acute rejections,and enable tailored use of maintenance agents.Rabbit anti-thymocyte globulin(rATG)and interleukin-2 receptor anatagonists(IL-2RA/IL-2RBs)are the most widely used induction therapies.However,data on induction practices across India are limited.To evaluate induction immunosuppression practices across KT centers in India and establish a consensus for different subsets of KT recipients.A nationwide online survey was conducted by the Indian Society of Organ Transplantation(ISOT)among its members(400 KT centers).Responses were analyzed to assess induction practices across diverse donor types,age groups,and immunological risk profiles.Heterogeneity in practices prompted consensus building using a modified Delphi process.Literature review and expert panel discussions(April 2024)were followed by structured voting,and 16 consensus statements were finalized.Of 400 centers approached,254 participated.rATG was the most commonly used induction therapy,followed by IL-2RBs;alemtuzumab was least used.Significant heterogeneity was observed in type,dose,and duration of induction therapy.Consensus recommendations were framed:rATG for high immunological risk recipients and deceased donor KTs;IL-2RB or low-dose rATG for low immunological risk;rituximab in ABOincompatible KTs;and tailoring based on age,diabetes,donor type,infection risk,and affordability.This first ISOT consensus provides 16 India-specific statements on induction therapy in KT.It emphasizes risk-stratified,evidenceinformed,and context-appropriate induction strategies,supporting standardization of care across the country.展开更多
Small multi-turn coil devices are used with the transient electromagnetic method (TEM) in areas with limited space, particularly in underground environments such as coal mines roadways and engineering tunnels, and f...Small multi-turn coil devices are used with the transient electromagnetic method (TEM) in areas with limited space, particularly in underground environments such as coal mines roadways and engineering tunnels, and for detecting shallow geological targets in environmental and engineering fields. However, the equipment involved has strong mutual inductance coupling, which causes a lengthy turn-off time and a deep “blind zone”. This study proposes a new transmitter device with a conical-shape source and derives the radius formula of each coil and the mutual inductance coefficient of the cone. According to primary field characteristics, results of the two fields created, calculation of the conical-shaped source in a uniform medium using theoretical analysis, and a comparison of the inductance of the new device with that of the multi-turn coil, show that inductance of the multi-turn coil is nine times greater than that of the conical source with the same equivalent magnetic moment of 926.1 A·m2. This indicates that the new source leads to a much shallower “blind zone.” Furthermore, increasing the bottom radius and turn of the cone creates a larger mutual inductance but increasing the cone height results in a lower mutual inductance. Using the superposition principle, the primary and secondary magnetic fields for a conical source in a homogeneous medium are calculated; results indicate that the magnetic behavior of the cone is the same as that of the multi-turn coils, but the transient responses of the secondary field and the total field are more stronger than those of the multi-turn coils. To study the transient response characteristics using a cone-shaped source in a layered earth, a numerical filtering algorithm is then developed using the fast Hankel transform and the improved cosine transform, again using the superposition principle. During development, an average apparent resistivity inverted from the induced electromotive force using each coil is defined to represent the comprehensive resistivity of the conical source. To verify the forward calculation method, the transient responses of H type models and KH type models are calculated, and data are inverted using a “smoke ring” inversion. The results of inversion have good agreement with original models and show that the forward calculation method is effective. The results of this study provide an option for solving the problem of a deep “blind zone” and also provide a theoretical indicator for further research.展开更多
We study the quantization of mesoscopic inductance coupling circuit and discuss its time evolution. Bymeans of the thermal field dynamics theory we study the quantum fluctuation of the system at finite temperature.
We study the quantum fluctuations of the charge and current of two L-C dissipative mesoscopic circuit with the mutual inductance in the vacuum state.Our results show that the system state will evolve to a squeezed coh...We study the quantum fluctuations of the charge and current of two L-C dissipative mesoscopic circuit with the mutual inductance in the vacuum state.Our results show that the system state will evolve to a squeezed coherent state under the effect of external source.We find that the squeezing amplitude parameter is relative to the parameters of circuit and the mutual-inductance coefficient in the existence of dissipation.When the circuit has no dissipation or there is complete coupling between two meshes,the squeezing amplitude parameter only depends on the capacitance's ratio.展开更多
New electronically-controllable lossless grounded and floating inductance simulation circuits have been proposed employing Voltage Differencing Transconductance Amplifiers (VDTA). The proposed grounded inductance (GI)...New electronically-controllable lossless grounded and floating inductance simulation circuits have been proposed employing Voltage Differencing Transconductance Amplifiers (VDTA). The proposed grounded inductance (GI) circuit employs a single VDTA and one grounded capacitor whereas the floating inductance (FI) circuit employs two VDTAs and one grounded capacitor. The workability of the new circuits has been verified using SPICE simulation with TSMC CMOS 0.18 μm process parameters.展开更多
New Voltage Differencing Differential Input Buffered Amplifier (VD-DIBA) based lossless grounded and floating inductance simulation circuits have been proposed. The proposed grounded simulated inductance circuit emplo...New Voltage Differencing Differential Input Buffered Amplifier (VD-DIBA) based lossless grounded and floating inductance simulation circuits have been proposed. The proposed grounded simulated inductance circuit employs a single VD-DIBA, one floating resistance and one grounded capacitor. The floating simulated inductance (FI) circuits employ two VD-DIBAs with two passive components (one floating resistance and one grounded capacitor). The circuit for grounded inductance does not require any realization conditions where as in case of floating inductance circuits, a single matching condition is needed. Simulation results demonstrating the applications of the new simulated inductors using CMOS VD-DIBAs have been included to confirm the workability of the new circuits.展开更多
Low-frequency double-resonance quartz crystal oscillator was developed with active inductance circuit aiming the start-up of stable oscillation of tuning fork-type quartz crystal resonator at 32.768 kHz within 0.37 ms...Low-frequency double-resonance quartz crystal oscillator was developed with active inductance circuit aiming the start-up of stable oscillation of tuning fork-type quartz crystal resonator at 32.768 kHz within 0.37 ms. The initial oscillation is triggered by a part of crystal oscillator forming a CR oscillator. The negative resistance ranges to 4 MΩ at gmf of 4.1 μA/V. In a limited frequency range, the circuit shows negative reactance Ccci = -3.4 pF equivalent to inductance Lcc = 9.8 H. The Allan standard deviation indicated 10-11 to 10-10, showing high stability comparable to general quartz crystal oscillator.展开更多
This paper deals with an analytical method to effectively calculate the inductance of an exterior-rotor switched reluctance motor(SRM),which evaluates the winding inductance of both the active section and the end sect...This paper deals with an analytical method to effectively calculate the inductance of an exterior-rotor switched reluctance motor(SRM),which evaluates the winding inductance of both the active section and the end section,accounting for the influence of core saturation.According to the inductance calculated by the analytical model,the flux linkage table and torque table can be established,and the steady state performance such as phase current,flux linkage,copper loss and core loss can be predicted.Effectiveness of this method is verified by the finite element method as well as by experimental results of a 12/8 SRM prototype.展开更多
Polygonal coil systems are designed for increasing and more kinds of sensors and electromagnetic systems.This paper presents a method for calculating mutual inductance between polygonal coils including irregular polyg...Polygonal coil systems are designed for increasing and more kinds of sensors and electromagnetic systems.This paper presents a method for calculating mutual inductance between polygonal coils including irregular polygons.Based on the Biot-Savart law,the method calculates mutual inductance by dividing a polygonal coil into finite wires,and expresses the magnetic induction intensity generated by the excitation coil as a function of the spatial position of each vertex of the coil.The calculation method of the feasible region of the objective function is updated and the calculation process is simplified,so the calculation accuracy is improved.For octagon coils arbitrarily positioned in space,the accuracy of the algorithm is verified by the simulation and experiment.展开更多
Magnetorheological(MR)materials are a class of smart material,whose the mechanical/rheological state can be controlled under a magnetic field.Magnetorheological materials are typically fluids,gels,or elastomers.In thi...Magnetorheological(MR)materials are a class of smart material,whose the mechanical/rheological state can be controlled under a magnetic field.Magnetorheological materials are typically fluids,gels,or elastomers.In this study,anisotropic and isotropic magneto-rheological elastomer(MRE)samples were fabricated using a silicone rubber matrix with carbonyl iron particles as filler particles.The magnetic field-dependent inductance properties of these samples were studied using inductors specially designed for the analysis.The effect of the filler particle content,fabrication conditions,and inductance properties were characterized using a self-built system in both constant and transient magnetic fields.These factors show a significant effect on the inductance properties of the MRE inductor under an applied magnetic field.The anisotropic MRE inductor was more sensitive than the inductor based on an isotropic MRE.Owing to the presence of a constant magnetic field,the inductance value of the MRE inductor decreased with an increase in the external magnetic field.An attempt in elucidation of the mechanism is reported here.This study may enable the MRE to be widely used in practical applications such as monitoring magnetic field or detecting the filler particle content inside MR materials.展开更多
A configuration using current feedback amplifiers AD844 and multiplier AD534 has been presented, which is capable of realizing Voltage Controlled Floating Inductance (proportional and in-verse proportional). The appli...A configuration using current feedback amplifiers AD844 and multiplier AD534 has been presented, which is capable of realizing Voltage Controlled Floating Inductance (proportional and in-verse proportional). The application of band pass filter in Figure 4(a), notch filter in Figure 5(a) and Hartley oscillator in Figure 6(a) and simulation result in Figures 4(b)-(d), Figures 5(b)-(d), Figures 6(b)-(d) shows the workability of proposed configuration.展开更多
Inductance asymmetry,which is brought by inherent asymmetric parameters,manufacture tolerance,winding fault,cables with unequal lengths,etc.,of permanent-magnet synchronous machines(PMSMs)can cause current harmonics a...Inductance asymmetry,which is brought by inherent asymmetric parameters,manufacture tolerance,winding fault,cables with unequal lengths,etc.,of permanent-magnet synchronous machines(PMSMs)can cause current harmonics and inaccurate position estimation.This paper proposes an enhanced fundamental model based sensorless control strategy for PMSMs with asymmetric inductances.The proportional-integral-resonant current regulator is introduced to reduce the second-order harmonics of currents,but there are still negative sequence components in the estimated back-electromotive forces(EMFs),which can cause the position estimated error.Differing from conventional methods in which negative sequences are filtered out before the phase-locked loop(PLL)module,the proposed method directly applies the estimated back-EMF with negative sequences as the reference input of PLL.An improved PLL with a bi-quad filter is proposed to attenuate the arising second harmonic position error and heighten the steady-state accuracy.Then,this position error is used for asymmetric inductance identification and its result is utilized to update the observer model.Furthermore,the dynamic performance is improved by the output limitation on the bi-quad filter as well as the implementation of a fast-locking technique in the PLL.The effectiveness of the proposed scheme is verified by experimental results.展开更多
In order to achieve high precision measurement of inductance in a wide frequency range,a method of inductance measurement based on double-excitation auto-balancing bridge is proposed.In this method,the direct digital ...In order to achieve high precision measurement of inductance in a wide frequency range,a method of inductance measurement based on double-excitation auto-balancing bridge is proposed.In this method,the direct digital synthesizer(DDS)as signal generator is used as the bridge excitation source,and the bridge is automatically balanced by adjusting and measuring the voltage ratio.Using standard resistors,the system can achieve high precision measurement of four-terminal pair inductors in the frequency range of 100Hz-100kHz.Aiming at the low efficiency of bridge balancing,an iterative balancing algorithm based on the steepest descent method is proposed.In order to suppress the interference caused by the initial phase change and non-integer periodic sampling,the high-precision measurement of the complex impedance of inductance is realized based on the all-phase fast Fourier transform(apFFT).Finally,the corresponding measurement system is built and the inductance measurement experiment is carried out.The experimental results show that the relative error of the system for inductance measurement can be as low as 0.009%,and the optimal relative measurement uncertainty of the system can reach 9.89×10^(-4)compared with 5×10^(-5)of commercial impedance analyzer.展开更多
Three-dimensional(3D) single-layer microcoils have always been a key element for electromagnetic systems;but they lack an easy and accurate method to calculate the inductance value for their complex 3D micro-structure...Three-dimensional(3D) single-layer microcoils have always been a key element for electromagnetic systems;but they lack an easy and accurate method to calculate the inductance value for their complex 3D micro-structures. This paper employed a curve-fitting process to obtain the associated equation for the inductance value and geometric parameters based on the simulation results. The correction factors regarding helical pitch and wire diameter were reviewed,which are used for compensation in the Nagaoka formula. The simulation process numerically simulated the performance of the 3D microcoils using a FEM electro-magnetic-coupled analysis method. Comparison of the simulated inductance value and the Nagaoka formula was undertaken,which shows that the helical pitch and wire diameter contribute a main role in the calculation error. The derived formula was expressed in a concise form to precisely calculate the inductance value of 3D microsolenoids with single-layer coils.展开更多
基金supported by the National Key Research and Development Program of China(2023YFC2206601)the National Natural Science Foundation of China(12273024,62205211)the Science and Technology Commission of Shanghai Municipality(23010503900,22590780100).
文摘Superconducting kinetic inductance detectors(KIDs)are considered to be a highly promising technique for the large-scale imaging of millimeter and submillimeter waves in astronomy.As the pixel density and the array size increase,the electromagnetic crosstalk inevitably becomes a problem that prevents increasing the multiplexing during the development of larger KIDs arrays.In this work,an effective method is introduced to suppress the electromagnetic crosstalk and achieve a compact pixel distribution and small frequency intervals.The electromagnetic crosstalk is first analyzed by simulating the behavior of two neighboring pixels,and the physical distance and the frequency interval are optimized.Then,the arrangement of the pixels on the whole array is redesigned using a genetic algorithm to satisfy the requirements.The simulation results reveal that the normalized electromagnetic crosstalk can be reduced to 0.5%on an 8×8 array.Larger arrays of 16×16 pixels have been fabricated and measured to validate this method,and the results reveal that both the resonance property and survival rate of pixels are improved effectively with this method.This method will be very helpful for designing high-multiplexing KIDs arrays within a limited bandwidth.
基金supported in part by the National Natural Science Foundation of China(62473387)the Southern Marine Science and Engineering Guangdong Laboratory(Zhuhai)(SML2023SP241)the Department of Science and Technology of Guangdong Province(2021QN020085)。
文摘For permanent magnet synchronous machines(PMSMs),accurate inductance is critical for control design and condition monitoring.Owing to magnetic saturation,existing methods require nonlinear saturation model and measurements from multiple load/current conditions,and the estimation is relying on the accuracy of saturation model and other machine parameters in the model.Speed harmonic produced by harmonic currents is inductance-dependent,and thus this paper explores the use of magnitude and phase angle of the speed harmonic for accurate inductance estimation.Two estimation models are built based on either the magnitude or phase angle,and the inductances can be from d-axis voltage and the magnitude or phase angle,in which the filter influence in harmonic extraction is considered to ensure the estimation performance.The inductances can be estimated from the measurements under one load condition,which is free of saturation model.Moreover,the inductance estimation is robust to the change of other machine parameters.The proposed approach can effectively improve estimation accuracy especially under the condition with low current magnitude.Experiments and comparisons are conducted on a test PMSM to validate the proposed approach.
基金supported by the National Key Research and Development Project of the National Natural Science Foundation of China(Grant No.2022YFC3004605)the National Natural Science Foundation of China Youth Science Fund(Grant No.52104087).
文摘To advance the theoretical understanding,technological development,and field application of electric charge induction for monitoring rock deformation and failure,this study investigates the induced electric charge generated during the deformation and failure of igneous rocks.The charge originates mainly from a combination of electrical polarization and triboelectric effects.Through laboratory experiments,we analyzed the time-frequency evolution of induced electric charge signals and identified relevant monitoring parameters.An online downhole electric charge induction monitoring system was developed and validated in the field.Experimental results show that the dominant frequency range of induced electric charge signals generated during igneous rock deformation and failure lies between 0 and 23 Hz,and a low-pass finite impulse response(FIR)filter effectively suppresses noise.Optimal sensor distances for monitoring cubic and cylindrical specimens were determined to be 17 mm and 13 mm,respectively.We proposed early warning indicators,including the maximum absolute value of the induced electric charge,the arithmetic mean value,the distribution dispersion coefficient,and the cumulative sum value.In field application,time-domain curves and spatial distribution charts of these warning indicators correspond well with changes in abutment stress ahead of the mining face,offering indirect insights into local stress evolution.This research provides technical and equipment support for the application of electric charge induction technology to monitoring and early warning of coal bursts.
文摘BACKGROUND The use of induction immunosuppression agents has improved kidney transplant outcomes,but selecting the optimal agent remains a point of debate.AIM To compare the long-term outcomes of kidney transplant recipients receiving alemtuzumab vs basiliximab induction,focusing on graft function,acute rejection,infection,malignancy,post-transplant glomerulonephritis,and survival,using a propensity score matched cohort design.METHODS Kidney transplant recipients who received alemtuzumab or basiliximab induction from 2014 to 2019 across two nephrology centres in Northwest England were evaluated.Propensity score matching at a 1:1.5 ratio ensured comparability between cohorts.Baseline characteristics,immunosuppression regimens,and outcomes were analyzed.Linear,binary logistic and Cox proportional hazard regression models.RESULTS A total of 436 recipients were included,with a median follow-up of 5.2 years.The matched cohort(n=262)had a mean age of 51.1±13.5 years;39%were female and 92%were white.There was no significant difference in the cumulative incidence of acute rejection[odds ratio(OR)=2.10;95%CI:0.9-4.9;P=0.110].Compared with basiliximab,alemtuzumab was associated with lower estimated glomerular filtration rate at 12 months(-6.6 mL/minute/1.73 m2;95%CI:-10.5 to-2.7;P<0.001)and higher risks of cytomegalovirus viremia(OR=3.2;95%CI:1.6-6.5;P<0.001),BK viremia(OR=2.4;95%CI:1.1-5.5;P=0.02),post-transplant malignancy(OR=6.2;95%CI:1.6-29.9;P=0.013),and death-censored graft loss(hazard ratio=3.6;95%CI:1.2-11.4;P=0.03).No significant differences were observed in post-transplant glomerulonephritis or recipient mortality.CONCLUSION In this propensity score-matched analysis,alemtuzumab induction was associated with lower graft function at 12 months and higher risks of viral infection,post-transplant malignancy,and graft loss compared with basiliximab.These findings highlight the need for further studies to confirm the long-term safety and effectiveness of alemtuzumab in kidney transplantation.
基金supported by the National Natural Science Foundation of China(Grant Nos.12075049 and 11935005)。
文摘Improving plasma uniformity is a critical issue in the development of large-area radio-frequency(RF)inductively coupled plasma(ICP)sources.In this work,the effects of coil structure and electromagnetic shielding on the spatial distribution and uniformity of the plasma are systematically investigated using a three-dimensional fluid model.The model integrates plasma and electromagnetic field modules to simulate the discharge characteristics of a large-area RF ICP source with dimensions of 100 cm×50 cm.The results reveal that the electron density distribution varies significantly with the coil structure.For the rotating and translating coil structures,the electron density is high at off-axis positions and low at the center.In contrast,the mirror coil structure exhibits a significantly higher electron density at the chamber center,resulting in a high-center and low-edge density distribution.Among the three configurations,the rotating coil structure provides the best plasma uniformity.The incorporation of electromagnetic shielding further improves plasma uniformity,particularly for the mirror coil structure.For the rotating and translating coil structures,the electron density exhibits a saddle-shaped distribution regardless of electromagnetic shielding.However,introducing electromagnetic shielding into the mirror coil structure reduces the electron density at the chamber center and decreases the non-uniformity degree by 18.4%.Overall,the mirror coil structure with electromagnetic shielding achieves the highest uniformity,with an exceptional plasma uniformity of 94%.This work offers valuable insights for the design of large-area ICP sources in advanced plasma processing systems.
基金funded by the Science and Technology Projects of State Grid Corporation of China(Project No.J2024136).
文摘To ensure an uninterrupted power supply,mobile power sources(MPS)are widely deployed in power grids during emergencies.Comprising mobile emergency generators(MEGs)and mobile energy storage systems(MESS),MPS are capable of supplying power to critical loads and serving as backup sources during grid contingencies,offering advantages such as flexibility and high resilience through electricity delivery via transportation networks.This paper proposes a design method for a 400 V–10 kV Dual-Winding Induction Generator(DWIG)intended for MEG applications,employing an improved particle swarmoptimization(PSO)algorithmbased on a back-propagation neural network(BPNN).A parameterized finite element(FE)model of the DWIG is established to derive constraints on its dimensional parameters,thereby simplifying the optimization space.Through sensitivity analysis between temperature rise and electromagnetic loss of the DWIG,the main factors influencing the machine’s temperature are identified,and electromagnetic loss is determined as the optimization objective.To obtain an accurate fitting function between electromagnetic loss and dimensional parameters,the BPNN is employed to predict the nonlinear relationship between the optimization objective and the parameters.The Latin hypercube sampling(LHS)method is used for random sampling in the FE model analysis for training,testing,and validation,which is then applied to compute the cost function in the PSO.Based on the relationships obtained by the BPNN,the PSO algorithm evaluates the fitness and cost functions to determine the optimal design point.The proposed optimization method is validated by comparing simulation results between the initial design and the optimized design.
文摘Kidney transplantation(KT)accounts for nearly three-fourths of organ transplants in India,with living donors contributing to 82%of cases.Induction immunosuppression is essential to optimize initial immunosuppression,reduce acute rejections,and enable tailored use of maintenance agents.Rabbit anti-thymocyte globulin(rATG)and interleukin-2 receptor anatagonists(IL-2RA/IL-2RBs)are the most widely used induction therapies.However,data on induction practices across India are limited.To evaluate induction immunosuppression practices across KT centers in India and establish a consensus for different subsets of KT recipients.A nationwide online survey was conducted by the Indian Society of Organ Transplantation(ISOT)among its members(400 KT centers).Responses were analyzed to assess induction practices across diverse donor types,age groups,and immunological risk profiles.Heterogeneity in practices prompted consensus building using a modified Delphi process.Literature review and expert panel discussions(April 2024)were followed by structured voting,and 16 consensus statements were finalized.Of 400 centers approached,254 participated.rATG was the most commonly used induction therapy,followed by IL-2RBs;alemtuzumab was least used.Significant heterogeneity was observed in type,dose,and duration of induction therapy.Consensus recommendations were framed:rATG for high immunological risk recipients and deceased donor KTs;IL-2RB or low-dose rATG for low immunological risk;rituximab in ABOincompatible KTs;and tailoring based on age,diabetes,donor type,infection risk,and affordability.This first ISOT consensus provides 16 India-specific statements on induction therapy in KT.It emphasizes risk-stratified,evidenceinformed,and context-appropriate induction strategies,supporting standardization of care across the country.
基金supported by the National Natural Science Foundation of China(Nos.41564001 and 41572185)the Natural Science Foundation of Jiangxi Province(No.20151BAB203045)
文摘Small multi-turn coil devices are used with the transient electromagnetic method (TEM) in areas with limited space, particularly in underground environments such as coal mines roadways and engineering tunnels, and for detecting shallow geological targets in environmental and engineering fields. However, the equipment involved has strong mutual inductance coupling, which causes a lengthy turn-off time and a deep “blind zone”. This study proposes a new transmitter device with a conical-shape source and derives the radius formula of each coil and the mutual inductance coefficient of the cone. According to primary field characteristics, results of the two fields created, calculation of the conical-shaped source in a uniform medium using theoretical analysis, and a comparison of the inductance of the new device with that of the multi-turn coil, show that inductance of the multi-turn coil is nine times greater than that of the conical source with the same equivalent magnetic moment of 926.1 A·m2. This indicates that the new source leads to a much shallower “blind zone.” Furthermore, increasing the bottom radius and turn of the cone creates a larger mutual inductance but increasing the cone height results in a lower mutual inductance. Using the superposition principle, the primary and secondary magnetic fields for a conical source in a homogeneous medium are calculated; results indicate that the magnetic behavior of the cone is the same as that of the multi-turn coils, but the transient responses of the secondary field and the total field are more stronger than those of the multi-turn coils. To study the transient response characteristics using a cone-shaped source in a layered earth, a numerical filtering algorithm is then developed using the fast Hankel transform and the improved cosine transform, again using the superposition principle. During development, an average apparent resistivity inverted from the induced electromotive force using each coil is defined to represent the comprehensive resistivity of the conical source. To verify the forward calculation method, the transient responses of H type models and KH type models are calculated, and data are inverted using a “smoke ring” inversion. The results of inversion have good agreement with original models and show that the forward calculation method is effective. The results of this study provide an option for solving the problem of a deep “blind zone” and also provide a theoretical indicator for further research.
文摘We study the quantization of mesoscopic inductance coupling circuit and discuss its time evolution. Bymeans of the thermal field dynamics theory we study the quantum fluctuation of the system at finite temperature.
文摘We study the quantum fluctuations of the charge and current of two L-C dissipative mesoscopic circuit with the mutual inductance in the vacuum state.Our results show that the system state will evolve to a squeezed coherent state under the effect of external source.We find that the squeezing amplitude parameter is relative to the parameters of circuit and the mutual-inductance coefficient in the existence of dissipation.When the circuit has no dissipation or there is complete coupling between two meshes,the squeezing amplitude parameter only depends on the capacitance's ratio.
文摘New electronically-controllable lossless grounded and floating inductance simulation circuits have been proposed employing Voltage Differencing Transconductance Amplifiers (VDTA). The proposed grounded inductance (GI) circuit employs a single VDTA and one grounded capacitor whereas the floating inductance (FI) circuit employs two VDTAs and one grounded capacitor. The workability of the new circuits has been verified using SPICE simulation with TSMC CMOS 0.18 μm process parameters.
文摘New Voltage Differencing Differential Input Buffered Amplifier (VD-DIBA) based lossless grounded and floating inductance simulation circuits have been proposed. The proposed grounded simulated inductance circuit employs a single VD-DIBA, one floating resistance and one grounded capacitor. The floating simulated inductance (FI) circuits employ two VD-DIBAs with two passive components (one floating resistance and one grounded capacitor). The circuit for grounded inductance does not require any realization conditions where as in case of floating inductance circuits, a single matching condition is needed. Simulation results demonstrating the applications of the new simulated inductors using CMOS VD-DIBAs have been included to confirm the workability of the new circuits.
文摘Low-frequency double-resonance quartz crystal oscillator was developed with active inductance circuit aiming the start-up of stable oscillation of tuning fork-type quartz crystal resonator at 32.768 kHz within 0.37 ms. The initial oscillation is triggered by a part of crystal oscillator forming a CR oscillator. The negative resistance ranges to 4 MΩ at gmf of 4.1 μA/V. In a limited frequency range, the circuit shows negative reactance Ccci = -3.4 pF equivalent to inductance Lcc = 9.8 H. The Allan standard deviation indicated 10-11 to 10-10, showing high stability comparable to general quartz crystal oscillator.
文摘This paper deals with an analytical method to effectively calculate the inductance of an exterior-rotor switched reluctance motor(SRM),which evaluates the winding inductance of both the active section and the end section,accounting for the influence of core saturation.According to the inductance calculated by the analytical model,the flux linkage table and torque table can be established,and the steady state performance such as phase current,flux linkage,copper loss and core loss can be predicted.Effectiveness of this method is verified by the finite element method as well as by experimental results of a 12/8 SRM prototype.
文摘Polygonal coil systems are designed for increasing and more kinds of sensors and electromagnetic systems.This paper presents a method for calculating mutual inductance between polygonal coils including irregular polygons.Based on the Biot-Savart law,the method calculates mutual inductance by dividing a polygonal coil into finite wires,and expresses the magnetic induction intensity generated by the excitation coil as a function of the spatial position of each vertex of the coil.The calculation method of the feasible region of the objective function is updated and the calculation process is simplified,so the calculation accuracy is improved.For octagon coils arbitrarily positioned in space,the accuracy of the algorithm is verified by the simulation and experiment.
基金Project(cstc2019jcyj-msxm X0005)supported by General Program of Chongqing Natural Science Foundation,ChinaProject(51905062)supported by the National Natural Science Foundation of China。
文摘Magnetorheological(MR)materials are a class of smart material,whose the mechanical/rheological state can be controlled under a magnetic field.Magnetorheological materials are typically fluids,gels,or elastomers.In this study,anisotropic and isotropic magneto-rheological elastomer(MRE)samples were fabricated using a silicone rubber matrix with carbonyl iron particles as filler particles.The magnetic field-dependent inductance properties of these samples were studied using inductors specially designed for the analysis.The effect of the filler particle content,fabrication conditions,and inductance properties were characterized using a self-built system in both constant and transient magnetic fields.These factors show a significant effect on the inductance properties of the MRE inductor under an applied magnetic field.The anisotropic MRE inductor was more sensitive than the inductor based on an isotropic MRE.Owing to the presence of a constant magnetic field,the inductance value of the MRE inductor decreased with an increase in the external magnetic field.An attempt in elucidation of the mechanism is reported here.This study may enable the MRE to be widely used in practical applications such as monitoring magnetic field or detecting the filler particle content inside MR materials.
文摘A configuration using current feedback amplifiers AD844 and multiplier AD534 has been presented, which is capable of realizing Voltage Controlled Floating Inductance (proportional and in-verse proportional). The application of band pass filter in Figure 4(a), notch filter in Figure 5(a) and Hartley oscillator in Figure 6(a) and simulation result in Figures 4(b)-(d), Figures 5(b)-(d), Figures 6(b)-(d) shows the workability of proposed configuration.
基金supported in part by the National Key R&D Program of China under Grant 2019YFB1503700in part by the National Natural Science Foundation of China under Grant 51977191。
文摘Inductance asymmetry,which is brought by inherent asymmetric parameters,manufacture tolerance,winding fault,cables with unequal lengths,etc.,of permanent-magnet synchronous machines(PMSMs)can cause current harmonics and inaccurate position estimation.This paper proposes an enhanced fundamental model based sensorless control strategy for PMSMs with asymmetric inductances.The proportional-integral-resonant current regulator is introduced to reduce the second-order harmonics of currents,but there are still negative sequence components in the estimated back-electromotive forces(EMFs),which can cause the position estimated error.Differing from conventional methods in which negative sequences are filtered out before the phase-locked loop(PLL)module,the proposed method directly applies the estimated back-EMF with negative sequences as the reference input of PLL.An improved PLL with a bi-quad filter is proposed to attenuate the arising second harmonic position error and heighten the steady-state accuracy.Then,this position error is used for asymmetric inductance identification and its result is utilized to update the observer model.Furthermore,the dynamic performance is improved by the output limitation on the bi-quad filter as well as the implementation of a fast-locking technique in the PLL.The effectiveness of the proposed scheme is verified by experimental results.
基金National Key Research and Development Plan Project(No.2020YFB2010800)National Natural Science Foundation of China(Nos.61905175,51775377,61971307)+4 种基金Fok Ying Tung Education Foundation(No.171055)China Postdoctoral Science Foundation(No.2020M680878)Guangdong Province Key Research and Development Plan Project(No.2020B0404030001)Tianjin Science and Technology Plan Project(No.20YDTPJC01660)Project of Foreign Affairs Committee of China Aviation Development Sichuan Gas Turbine Research Institute(Nos.GJCZ-2020-0040,GJCZ-2020-0041)。
文摘In order to achieve high precision measurement of inductance in a wide frequency range,a method of inductance measurement based on double-excitation auto-balancing bridge is proposed.In this method,the direct digital synthesizer(DDS)as signal generator is used as the bridge excitation source,and the bridge is automatically balanced by adjusting and measuring the voltage ratio.Using standard resistors,the system can achieve high precision measurement of four-terminal pair inductors in the frequency range of 100Hz-100kHz.Aiming at the low efficiency of bridge balancing,an iterative balancing algorithm based on the steepest descent method is proposed.In order to suppress the interference caused by the initial phase change and non-integer periodic sampling,the high-precision measurement of the complex impedance of inductance is realized based on the all-phase fast Fourier transform(apFFT).Finally,the corresponding measurement system is built and the inductance measurement experiment is carried out.The experimental results show that the relative error of the system for inductance measurement can be as low as 0.009%,and the optimal relative measurement uncertainty of the system can reach 9.89×10^(-4)compared with 5×10^(-5)of commercial impedance analyzer.
基金supported by the National Science Foundation of China under the Grant No.61176113 and 51335008the Special-funded program on national key scientific instruments and equipment development of China under the Grant No.2012YQ12004706the Program for Changjiang Scholars and Innovative Research Team in University(IRT1033)。
文摘Three-dimensional(3D) single-layer microcoils have always been a key element for electromagnetic systems;but they lack an easy and accurate method to calculate the inductance value for their complex 3D micro-structures. This paper employed a curve-fitting process to obtain the associated equation for the inductance value and geometric parameters based on the simulation results. The correction factors regarding helical pitch and wire diameter were reviewed,which are used for compensation in the Nagaoka formula. The simulation process numerically simulated the performance of the 3D microcoils using a FEM electro-magnetic-coupled analysis method. Comparison of the simulated inductance value and the Nagaoka formula was undertaken,which shows that the helical pitch and wire diameter contribute a main role in the calculation error. The derived formula was expressed in a concise form to precisely calculate the inductance value of 3D microsolenoids with single-layer coils.