Purpose–The efficient utilization of recycled concrete powder(RCP)has attracted much attention.To break through the limitation of single activation technology of RCP,this study investigates the effects of a mechanica...Purpose–The efficient utilization of recycled concrete powder(RCP)has attracted much attention.To break through the limitation of single activation technology of RCP,this study investigates the effects of a mechanical-microwave method on the reactivity of RCP.Design/methodology/approach–The mechanical properties,hydration products,and pore structure of RCP-incorporated mortar were evaluated.Findings–The results demonstrate that the combined activation reduces the median particle size of RCP and induces a low-frequency shift in the Si-O-T FT-IR characteristic peaks,signifying depolymerization of the silicate network and formation of highly reactive broken bond sites.Concurrently,decreased Si2p and Al2p binding energies in XPS spectra confirm enhanced surface reactivity.The 28-day strength activity index(SAI)of RCP mortar improved from 65.7(untreated)to 82.2%under optimal activation conditions(90-min ball milling followed by 10-min microwave irradiation),outperforming solely mechanical activation by 3.6–6.1%.Furthermore,combined activation increased chemically bound water content from 22.8 to 33.7%,accompanied by a low-wavenumber shift in FT-IR peaks of hydration products.The total porosity of RCP mortar decreased from 17.2 to 14.6%,indicating a denser pore structure.Originality/value–This study explores the feasibility and potential mechanism of mechanical-microwave activation of RCP,aiming to provide valuable insights for the sustainable development of materials.Using activated RCP in cement-based materials reduces the demand for cement and substantially cuts carbon emissions,thereby making a critical contribution to the construction industry’s green and low-carbon transition.展开更多
Optical frequency combs,as powerful tools for precision spectroscopy and research into optical frequency standards,have driven continuous progress and significant breakthroughs in applications such as time-frequency t...Optical frequency combs,as powerful tools for precision spectroscopy and research into optical frequency standards,have driven continuous progress and significant breakthroughs in applications such as time-frequency transfer,measurement of fundamental physical constants,and high-precision ranging,achieving a series of milestone results in ground-based environments.With the continuous maturation and evolution of femtosecond lasers and related technologies,optical frequency combs are moving from ground-based applications to astronomical and space-based applications,playing an increasingly important role in atomic clocks,exoplanet observations,gravitational wave measurements,and other areas.This paper,focusing on astronomical and space-based applications,reviews research progress on astronomical frequency combs,optical clock time-frequency networks,gravitational waves,dark matter measurement,dual-comb large-scale absolute ranging,and high-resolution atmospheric spectroscopy.With enhanced performance and their gradual application in the field of space-based research,optical frequency combs will undoubtedly provide more powerful support for astronomical science and cosmic exploration in the future.展开更多
Frequency combs with equally spaced frequency lines show great potentials for applications in spectroscopy,imag-ing,communications,and so on.In the terahertz frequency region,the quantum cascade laser(QCL)is an ideal ...Frequency combs with equally spaced frequency lines show great potentials for applications in spectroscopy,imag-ing,communications,and so on.In the terahertz frequency region,the quantum cascade laser(QCL)is an ideal radiation source for frequency comb and dual-comb operation.The systematic evaluation of phase noise characteristics of terahertz QCL frequency comb and dual-comb sources is of great importance for high precision measurements.In this work,we present detailed measurements and analysis of the phase noise characteristics of terahertz QCL frequency comb and dual-comb sources emitting around 4.2 THz with repetition frequencies of~6.2 GHz.The measurement results for the current noise of the direct current(DC)sources(that are used to electrically pump the terahertz QCLs)indicate that at 100 Hz,the current noise for DC-1 and DC-2 is 0.3895 and 0.0982 nA/Hz1/2,respectively.Such levels of current noise can be safely disregarded.The phase noise of radio frequency(RF)generators(that are employed for injection locking and phase locking),intermode beatnotes,and dual-comb signals with and without phase-locked loop(PLL)are all measured and compared.The experimental results show that in the free-running mode,the phase noise of the intermode beatnote signals is always lower than that of the dual-comb sig-nals across all frequencies.Additionally,the phase noise induced by the RF generators is negligible.By employing the phase lock-ing technique,the phase noise of the intermode beatnote and dual-comb signals in the low offset frequency band can be signifi-cantly suppressed.At an offset frequency of 100 Hz,the measured phase noise values of the dual-comb line without and with phase locking are 15.026 and-64.801 dBc/Hz,respectively.展开更多
Dual-comb interferometric systems with high time accuracy have been realized for various applications.The flourishing ultralow noise dual-comb system promotes the measurement and characterization of relative timing ji...Dual-comb interferometric systems with high time accuracy have been realized for various applications.The flourishing ultralow noise dual-comb system promotes the measurement and characterization of relative timing jitter,thus improving time accuracy.With optical solutions,introducing an optical reference enables 105 harmonics measurements,thereby breaking the limit set by electrical methods;nonlinear processes or spectral interference schemes were also employed to track the relative timing jitter.However,such approaches operating in the time domain either require additional continuous references or impose stringent requirements on the amount of timing jitter.We propose a scheme to correct the relative timing jitter of a free-running dual-comb interferometry assisted by a Fabry-Pérot(F-P)cavity in the frequency domain.With high wavelength thermal stability provided by the F-P cavity,the absolute wavelength deviation in the operating bandwidth is compressed to<0.4 pm,corresponding to a subpicosecond sensitivity of pulse-to-pulse relative timing jitter.Also,Allan deviation of 10^(-10) is obtained under multiple coherent averaging,which lays the foundation for mode-resolved molecular spectroscopic applications.The spectral absorption features of hydrogen cyanide gas molecules at ambient temperature were measured and matched to the HITRAN database.Our scheme promises to provide new ideas on sensitive measurements of relative timing jitter.展开更多
Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of pre...Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)].展开更多
Laser absorption spectroscopy has proven to be an effective approach for gas sensing, which plays an important rolein the fields of military, industry, medicine and basic research. This paper presents a multiplexed ga...Laser absorption spectroscopy has proven to be an effective approach for gas sensing, which plays an important rolein the fields of military, industry, medicine and basic research. This paper presents a multiplexed gas sensing system basedon optical frequency comb (OFC) calibrated frequency-modulated continuous-wave (FMCW) tuning nonlinearity. Thesystem can be used for multi-parameter synchronous measurement of gas absorption spectrum and multiplexed opticalpath. Multi-channel parallel detection is realized by combining wavelength division multiplexing (WDM) and frequencydivision multiplexing (FDM) techniques. By introducing nonlinear optical crystals, broadband spectrum detection is simultaneouslyachieved over a bandwidth of hundreds of nanometers. An OFC with ultra-high frequency stability is used asthe frequency calibration source, which guarantees the measurement accuracy. The test samples involve H13C14N, C_(2)H_(2)and Rb vapor cells of varying densities and 5 parallel measurement experiments are designed. The results show that themeasurement accuracies of spectral absorption line and the optical path are 150 MHz and 20 m, respectively. The schemeoffers the advantages of multiplexed, multi-parameter, wide spectrum and high resolution detection, which can realize theidentification of multi-gas components and the high-precision inversion of absorption lines under different environments.The proposed sensor demonstrates great potential in the field of high-resolution absorption spectrum measurement for gassensing applications.展开更多
Optical frequency comb with evenly spaced lines over a broad bandwidth has revolutionized the fields of optical metrology and spectroscopy.Here,we propose a fast interleaved dual-comb spectroscopy with sub-femtometer-...Optical frequency comb with evenly spaced lines over a broad bandwidth has revolutionized the fields of optical metrology and spectroscopy.Here,we propose a fast interleaved dual-comb spectroscopy with sub-femtometer-resolution and absolute frequency,in which two electro-optic frequency combs are swept.Electrically-modulated stabilized laser enables ultrahigh resolution of 0.16 fm(or 20 k Hz in optical frequency)and single-shot measurement in 90 ms.Total 20 million points are recorded spanning 3.2 nm(or 400 GHz)bandwidth,corresponding to a spectral sampling rate of 2.5×10^(8)points/s under Nyquist-limitation.Besides,considering the trade-off between the measurement time and spectral resolution,a fast single-shot measurement is also realized in 1.6 ms with 8 fm(or 1 MHz)resolution.We demonstrate the 25-averaged result with 30.6 d B spectral measurement signal-to-noise ratio(SNR)by reducing the filter bandwidth in demodulation.The results show great prospect for precise measurement with flexibly fast refresh time,high spectral resolution,and high SNR.展开更多
[Objective] The aim was to establish a rapid method for the determination of the content of total flavonoids in the honey comb. [Method] The content of total flavonoids weas determined based on samples including comb ...[Objective] The aim was to establish a rapid method for the determination of the content of total flavonoids in the honey comb. [Method] The content of total flavonoids weas determined based on samples including comb honey, propolis, royal jelly, linden tree honey, with a polyamide column chromatography by spectrophotometry at 360 nm wavelength. [Result] The recovery rate of the method was above 90%, and the variation coefficient was lower than 2%. Compared with the traditional method, this method has less reagent consumption, simple operation and so on.[Conclusion] The content of total flavonoids in comb honey was 14.97 mg/100 g, although is only 0.87% of the total flavone content in propolis. The contained total flavonoids at least doubled than that of others and comb honey is more valuable in the content of flavonoids.展开更多
The dropping scales is an important parameter for comber noil and combing quality. Because the rocking of the nipper shaft makes the nippers move backward and forward through a series of links, the original position o...The dropping scales is an important parameter for comber noil and combing quality. Because the rocking of the nipper shaft makes the nippers move backward and forward through a series of links, the original position of nipper frame is altered when changing the dropping scales, the other parameters of combing are changed accordingly. In this paper, the timing of opening-closing on nipper, the timing of cylinder’s combing, the timing of detaching-lapping and variation of nip pressure are calculated and their effects on combing are analyzed in different dropping scales on E7/6 comber.展开更多
An optical frequency comb comprises a cluster of equally spaced,phase-locked spectral lines.Replacing these classical components with correlated quantum light gives rise to cluster quantum frequency combs,providing ab...An optical frequency comb comprises a cluster of equally spaced,phase-locked spectral lines.Replacing these classical components with correlated quantum light gives rise to cluster quantum frequency combs,providing abundant quantum resources for measurement-based quantum computation,and multi-user quantum networks.We propose and generate cluster quantum microcombs within an on-chip optical microresonator driven by multi-frequency lasers.Through resonantly enhanced four-wave mixing processes,continuous-variable cluster states with 60 qumodes are deterministically created.The graph structures can be programmed into one-and two-dimensional lattices by adjusting the configurations of the pump lines,which are confirmed inseparable based on the measured covariance matrices.Our work demonstrates the largest-scale cluster states with unprecedented raw squeezing levels from a photonic chip,offering a compact and scalable platform for computational and communicational tasks with quantum advantages.展开更多
A three-part comb decimator is presented in this paper, for the applications with severe requirements of circuit performance and frequency response. Based on the modified prime factorization method and multistage poly...A three-part comb decimator is presented in this paper, for the applications with severe requirements of circuit performance and frequency response. Based on the modified prime factorization method and multistage polyphase decomposition, an efficient non-recursive structure for the cascaded integrator-comb (CIC) decimation filter is derived. Utilizing this structure as the core part, the proposed comb decimator can not only loosen the decimation ratio's limitation, but also balance the tradeoff among the overall power consumption, circuit area and maximum speed. Further, to improve the frequency response of the comb decimator, a cos-prefilter is introduced as the preprocessing part for increasing the aliasing rejection, and an optimum sin-based filter is used as the compensation part for decreasing the passband droop.展开更多
Frequency combs show various applications in molecular fingerprinting,imaging,communications,and so on.In the terahertz frequency range,semiconductor-based quantum cascade lasers(QCLs)are ideal platforms for realizing...Frequency combs show various applications in molecular fingerprinting,imaging,communications,and so on.In the terahertz frequency range,semiconductor-based quantum cascade lasers(QCLs)are ideal platforms for realizing the frequency comb operation.Although self-started frequency comb operation can be obtained in free-running terahertz QCLs due to the four-wave mixing locking effects,resonant/off-resonant microwave injection,phase locking,and femtosecond laser based locking techniques have been widely used to broaden and stabilize terahertz QCL combs.These active locking methods indeed show significant effects on the frequency stabilization of terahertz QCL combs,but they simultaneously have drawbacks,such as introducing large phase noise and requiring complex optical coupling and/or electrical circuits.Here,we demonstrate Farey tree locking of terahertz QCL frequency combs under microwave injection.The frequency competition between the Farey fraction frequency and the cavity round-trip frequency results in the frequency locking of terahertz QCL combs,and the Farey fraction frequencies can be accurately anticipated based on the downward trend of the Farey tree hierarchy.Furthermore,dual-comb experimental results show that the phase noise of the dual-comb spectral lines is significantly reduced by employing the Farey tree locking method.These results pave the way to deploying compact and low phase noise terahertz frequency comb sources.展开更多
We demonstrate an optical frequency comb based on an erbium-doped-fiber femtosecond laser with the nonlinear polarization evolution scheme. The repetition rate of the laser is about 209 MHz. By controlling an intra-ca...We demonstrate an optical frequency comb based on an erbium-doped-fiber femtosecond laser with the nonlinear polarization evolution scheme. The repetition rate of the laser is about 209 MHz. By controlling an intra-cavity electro- optic modulator and a piezo-transducer, the repetition rate can be stabilized with a high-bandwidth servo in a frequency range of 3 kHz, enabling long-term repetition rate phase-locking. The in-loop frequency stability of repetition rate is about 1.6× 10-13 in an integration time of 1 s, limited by the measurement system; and it is inversely proportional to integration time in the short term. Furthermore, using a common path f-2f interferometer, the carrier envelope offset frequency of the comb is obtained with a signal-to-noise ratio of 40 dB in a 3-MHz resolution bandwidth. Stabilized cartier envelope offset frequency exhibits a deviation of 0.6 mHz in an integration time of 1 s.展开更多
基金sponsored by Science and Technology Research and Development Plan of China National Railway Group Co.,Ltd.(L2022G009)National Natural Science Foundation of China(52438002)+1 种基金Research Project of China Academy of Railway Science Corporation Limited(2024YJ254)New Cornerstone Science Foundation through the XPLORER PRIZE.
文摘Purpose–The efficient utilization of recycled concrete powder(RCP)has attracted much attention.To break through the limitation of single activation technology of RCP,this study investigates the effects of a mechanical-microwave method on the reactivity of RCP.Design/methodology/approach–The mechanical properties,hydration products,and pore structure of RCP-incorporated mortar were evaluated.Findings–The results demonstrate that the combined activation reduces the median particle size of RCP and induces a low-frequency shift in the Si-O-T FT-IR characteristic peaks,signifying depolymerization of the silicate network and formation of highly reactive broken bond sites.Concurrently,decreased Si2p and Al2p binding energies in XPS spectra confirm enhanced surface reactivity.The 28-day strength activity index(SAI)of RCP mortar improved from 65.7(untreated)to 82.2%under optimal activation conditions(90-min ball milling followed by 10-min microwave irradiation),outperforming solely mechanical activation by 3.6–6.1%.Furthermore,combined activation increased chemically bound water content from 22.8 to 33.7%,accompanied by a low-wavenumber shift in FT-IR peaks of hydration products.The total porosity of RCP mortar decreased from 17.2 to 14.6%,indicating a denser pore structure.Originality/value–This study explores the feasibility and potential mechanism of mechanical-microwave activation of RCP,aiming to provide valuable insights for the sustainable development of materials.Using activated RCP in cement-based materials reduces the demand for cement and substantially cuts carbon emissions,thereby making a critical contribution to the construction industry’s green and low-carbon transition.
基金support of the National Natural Sci-ence Foundation of China(NSFC)(62305373)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDA1502040404,XDB2101040004).
文摘Optical frequency combs,as powerful tools for precision spectroscopy and research into optical frequency standards,have driven continuous progress and significant breakthroughs in applications such as time-frequency transfer,measurement of fundamental physical constants,and high-precision ranging,achieving a series of milestone results in ground-based environments.With the continuous maturation and evolution of femtosecond lasers and related technologies,optical frequency combs are moving from ground-based applications to astronomical and space-based applications,playing an increasingly important role in atomic clocks,exoplanet observations,gravitational wave measurements,and other areas.This paper,focusing on astronomical and space-based applications,reviews research progress on astronomical frequency combs,optical clock time-frequency networks,gravitational waves,dark matter measurement,dual-comb large-scale absolute ranging,and high-resolution atmospheric spectroscopy.With enhanced performance and their gradual application in the field of space-based research,optical frequency combs will undoubtedly provide more powerful support for astronomical science and cosmic exploration in the future.
基金supported by the Innovation Program for Quantum Science and Technology (2023ZD0301000)the National Science Fund for Distinguished Young Scholars (62325509)+3 种基金the National Natural Science Foundation of China (62235019,61875220,61927813,61991430,62035005,62105351,62275258,62035014,and 62305364)Science and Technology Commission of Shanghai Municipality (21ZR1474600)the"From 0 to 1"Innovation Program of the Chinese Academy of Sciences (ZDBS-LY-JSC009)the CAS Project for Young Scientists in Basic Research (YSBR-069).
文摘Frequency combs with equally spaced frequency lines show great potentials for applications in spectroscopy,imag-ing,communications,and so on.In the terahertz frequency region,the quantum cascade laser(QCL)is an ideal radiation source for frequency comb and dual-comb operation.The systematic evaluation of phase noise characteristics of terahertz QCL frequency comb and dual-comb sources is of great importance for high precision measurements.In this work,we present detailed measurements and analysis of the phase noise characteristics of terahertz QCL frequency comb and dual-comb sources emitting around 4.2 THz with repetition frequencies of~6.2 GHz.The measurement results for the current noise of the direct current(DC)sources(that are used to electrically pump the terahertz QCLs)indicate that at 100 Hz,the current noise for DC-1 and DC-2 is 0.3895 and 0.0982 nA/Hz1/2,respectively.Such levels of current noise can be safely disregarded.The phase noise of radio frequency(RF)generators(that are employed for injection locking and phase locking),intermode beatnotes,and dual-comb signals with and without phase-locked loop(PLL)are all measured and compared.The experimental results show that in the free-running mode,the phase noise of the intermode beatnote signals is always lower than that of the dual-comb sig-nals across all frequencies.Additionally,the phase noise induced by the RF generators is negligible.By employing the phase lock-ing technique,the phase noise of the intermode beatnote and dual-comb signals in the low offset frequency band can be signifi-cantly suppressed.At an offset frequency of 100 Hz,the measured phase noise values of the dual-comb line without and with phase locking are 15.026 and-64.801 dBc/Hz,respectively.
基金supported by the National Key Research and Development Program of China(Grant No.2022YFF0705904)the National Natural Science Foundation of China(Grant Nos.61927817 and 62075072).
文摘Dual-comb interferometric systems with high time accuracy have been realized for various applications.The flourishing ultralow noise dual-comb system promotes the measurement and characterization of relative timing jitter,thus improving time accuracy.With optical solutions,introducing an optical reference enables 105 harmonics measurements,thereby breaking the limit set by electrical methods;nonlinear processes or spectral interference schemes were also employed to track the relative timing jitter.However,such approaches operating in the time domain either require additional continuous references or impose stringent requirements on the amount of timing jitter.We propose a scheme to correct the relative timing jitter of a free-running dual-comb interferometry assisted by a Fabry-Pérot(F-P)cavity in the frequency domain.With high wavelength thermal stability provided by the F-P cavity,the absolute wavelength deviation in the operating bandwidth is compressed to<0.4 pm,corresponding to a subpicosecond sensitivity of pulse-to-pulse relative timing jitter.Also,Allan deviation of 10^(-10) is obtained under multiple coherent averaging,which lays the foundation for mode-resolved molecular spectroscopic applications.The spectral absorption features of hydrogen cyanide gas molecules at ambient temperature were measured and matched to the HITRAN database.Our scheme promises to provide new ideas on sensitive measurements of relative timing jitter.
基金supported by the National Natural Science Foundation China(No.42022051,No.U21A2028)Youth Innovation Promotion Association of the Chinese Academy of Sciences(No.Y202089)the HFIPS Director's Fund(No.YZJJ202101,No.BJPY2023A02).
文摘Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)].
基金the National Natural Science Foun-dation of China(Grant No.52375546)the National Key Research and Development Program of China(Grant No.2022YFF0705701).
文摘Laser absorption spectroscopy has proven to be an effective approach for gas sensing, which plays an important rolein the fields of military, industry, medicine and basic research. This paper presents a multiplexed gas sensing system basedon optical frequency comb (OFC) calibrated frequency-modulated continuous-wave (FMCW) tuning nonlinearity. Thesystem can be used for multi-parameter synchronous measurement of gas absorption spectrum and multiplexed opticalpath. Multi-channel parallel detection is realized by combining wavelength division multiplexing (WDM) and frequencydivision multiplexing (FDM) techniques. By introducing nonlinear optical crystals, broadband spectrum detection is simultaneouslyachieved over a bandwidth of hundreds of nanometers. An OFC with ultra-high frequency stability is used asthe frequency calibration source, which guarantees the measurement accuracy. The test samples involve H13C14N, C_(2)H_(2)and Rb vapor cells of varying densities and 5 parallel measurement experiments are designed. The results show that themeasurement accuracies of spectral absorption line and the optical path are 150 MHz and 20 m, respectively. The schemeoffers the advantages of multiplexed, multi-parameter, wide spectrum and high resolution detection, which can realize theidentification of multi-gas components and the high-precision inversion of absorption lines under different environments.The proposed sensor demonstrates great potential in the field of high-resolution absorption spectrum measurement for gassensing applications.
基金funding from National Natural Science Foundation of China(NSFC)under Grant Nos.61775132,61735015,61620106015supported by the Major Key Project of Peng Cheng Laboratory(PCL)。
文摘Optical frequency comb with evenly spaced lines over a broad bandwidth has revolutionized the fields of optical metrology and spectroscopy.Here,we propose a fast interleaved dual-comb spectroscopy with sub-femtometer-resolution and absolute frequency,in which two electro-optic frequency combs are swept.Electrically-modulated stabilized laser enables ultrahigh resolution of 0.16 fm(or 20 k Hz in optical frequency)and single-shot measurement in 90 ms.Total 20 million points are recorded spanning 3.2 nm(or 400 GHz)bandwidth,corresponding to a spectral sampling rate of 2.5×10^(8)points/s under Nyquist-limitation.Besides,considering the trade-off between the measurement time and spectral resolution,a fast single-shot measurement is also realized in 1.6 ms with 8 fm(or 1 MHz)resolution.We demonstrate the 25-averaged result with 30.6 d B spectral measurement signal-to-noise ratio(SNR)by reducing the filter bandwidth in demodulation.The results show great prospect for precise measurement with flexibly fast refresh time,high spectral resolution,and high SNR.
基金Supported by Guangzhou Municipal Colleges and Universities with Research Base Project in 2014(14CXY07)Institute of Scientific Research Projects in 2014(LK14002)the Transverse Research Project in 2014(w14001)~~
文摘[Objective] The aim was to establish a rapid method for the determination of the content of total flavonoids in the honey comb. [Method] The content of total flavonoids weas determined based on samples including comb honey, propolis, royal jelly, linden tree honey, with a polyamide column chromatography by spectrophotometry at 360 nm wavelength. [Result] The recovery rate of the method was above 90%, and the variation coefficient was lower than 2%. Compared with the traditional method, this method has less reagent consumption, simple operation and so on.[Conclusion] The content of total flavonoids in comb honey was 14.97 mg/100 g, although is only 0.87% of the total flavone content in propolis. The contained total flavonoids at least doubled than that of others and comb honey is more valuable in the content of flavonoids.
文摘The dropping scales is an important parameter for comber noil and combing quality. Because the rocking of the nipper shaft makes the nippers move backward and forward through a series of links, the original position of nipper frame is altered when changing the dropping scales, the other parameters of combing are changed accordingly. In this paper, the timing of opening-closing on nipper, the timing of cylinder’s combing, the timing of detaching-lapping and variation of nip pressure are calculated and their effects on combing are analyzed in different dropping scales on E7/6 comber.
基金supported by the National Key R&D Plan of China(Grant No.2021ZD0301500)Beijing Natural Science Foundation(Z210004,Z240007)+2 种基金National Natural Science Foundation of China(92150108,62222515,12125402,12174438)the High-performance Computing Platform of Peking Universitysupported by the Micro/nano Fabrication Laboratory of Synergetic Extreme Condition User Facility(SECUF).
文摘An optical frequency comb comprises a cluster of equally spaced,phase-locked spectral lines.Replacing these classical components with correlated quantum light gives rise to cluster quantum frequency combs,providing abundant quantum resources for measurement-based quantum computation,and multi-user quantum networks.We propose and generate cluster quantum microcombs within an on-chip optical microresonator driven by multi-frequency lasers.Through resonantly enhanced four-wave mixing processes,continuous-variable cluster states with 60 qumodes are deterministically created.The graph structures can be programmed into one-and two-dimensional lattices by adjusting the configurations of the pump lines,which are confirmed inseparable based on the measured covariance matrices.Our work demonstrates the largest-scale cluster states with unprecedented raw squeezing levels from a photonic chip,offering a compact and scalable platform for computational and communicational tasks with quantum advantages.
基金Supported by the China Postdoctoral Science Foundation (20080431379).
文摘A three-part comb decimator is presented in this paper, for the applications with severe requirements of circuit performance and frequency response. Based on the modified prime factorization method and multistage polyphase decomposition, an efficient non-recursive structure for the cascaded integrator-comb (CIC) decimation filter is derived. Utilizing this structure as the core part, the proposed comb decimator can not only loosen the decimation ratio's limitation, but also balance the tradeoff among the overall power consumption, circuit area and maximum speed. Further, to improve the frequency response of the comb decimator, a cos-prefilter is introduced as the preprocessing part for increasing the aliasing rejection, and an optimum sin-based filter is used as the compensation part for decreasing the passband droop.
基金supported by the Innovation Program for Quantum Science and Technology(2023ZD0301000)the National Science Fund for Distinguished Young Scholars(62325509)+2 种基金the National Natural Science Foundation of China(62235019,61875220,61927813,61991430,62035005,62105351,and 62305364)the“From 0 to 1”Innovation Program of the Chinese Academy of Sciences(ZDBS-LY-JSC009)the CAS Project for Young Scientists in Basic Research(YSBR-069).
文摘Frequency combs show various applications in molecular fingerprinting,imaging,communications,and so on.In the terahertz frequency range,semiconductor-based quantum cascade lasers(QCLs)are ideal platforms for realizing the frequency comb operation.Although self-started frequency comb operation can be obtained in free-running terahertz QCLs due to the four-wave mixing locking effects,resonant/off-resonant microwave injection,phase locking,and femtosecond laser based locking techniques have been widely used to broaden and stabilize terahertz QCL combs.These active locking methods indeed show significant effects on the frequency stabilization of terahertz QCL combs,but they simultaneously have drawbacks,such as introducing large phase noise and requiring complex optical coupling and/or electrical circuits.Here,we demonstrate Farey tree locking of terahertz QCL frequency combs under microwave injection.The frequency competition between the Farey fraction frequency and the cavity round-trip frequency results in the frequency locking of terahertz QCL combs,and the Farey fraction frequencies can be accurately anticipated based on the downward trend of the Farey tree hierarchy.Furthermore,dual-comb experimental results show that the phase noise of the dual-comb spectral lines is significantly reduced by employing the Farey tree locking method.These results pave the way to deploying compact and low phase noise terahertz frequency comb sources.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.91336101 and 61127901)West Light Foundation of the Chinese Academy of Sciences(Grant No.2013ZD02)
文摘We demonstrate an optical frequency comb based on an erbium-doped-fiber femtosecond laser with the nonlinear polarization evolution scheme. The repetition rate of the laser is about 209 MHz. By controlling an intra-cavity electro- optic modulator and a piezo-transducer, the repetition rate can be stabilized with a high-bandwidth servo in a frequency range of 3 kHz, enabling long-term repetition rate phase-locking. The in-loop frequency stability of repetition rate is about 1.6× 10-13 in an integration time of 1 s, limited by the measurement system; and it is inversely proportional to integration time in the short term. Furthermore, using a common path f-2f interferometer, the carrier envelope offset frequency of the comb is obtained with a signal-to-noise ratio of 40 dB in a 3-MHz resolution bandwidth. Stabilized cartier envelope offset frequency exhibits a deviation of 0.6 mHz in an integration time of 1 s.