The current technical standards primarily relied on experience to judge the interfacial bonding properties between the self-compacting concrete filling layer and the steam-cured concrete precast slab in CRTS Ⅲ slab b...The current technical standards primarily relied on experience to judge the interfacial bonding properties between the self-compacting concrete filling layer and the steam-cured concrete precast slab in CRTS Ⅲ slab ballastless track structure.This study sought to enhance technical standards for evaluating interfacial bonding properties by suggesting the use of the splitting tensile strength to evaluate the impact of bubble defects.Specimens were fabricated through on-site experiment.The percent of each area of 6 cm^(2)or more bubble defect was 0 in most of specimens.When the cumulative area of all bub-ble defects reached 12%,the splitting tensile strength value was 0.67 MPa,which exceeded the minimum required value of 0.5 MPa for ensuring bonding interface adhesion.Furthermore,when the cumulative area of all bubble defects reached 8%,the splitting tensile strength value was 0.85 MPa,which exceeded the minimum required value of 0.8 MPa,thereby over-coming the negative impact of each area of 10 cm^(2) or more bubble defect.Additionally,keeping the cumulative area of each area of 6 cm^(2) or more bubble defect below 6%ensured adequate bonding strength and reduced the occurrence of specimens with lower splitting tensile strength values.展开更多
基金supported by a grant from China railway corporation science and technology research and development plan project(Grant No.2017G005-B)funding support by Wuyi University’s Hong Kong and Macao Joint Research and Development Fund(Grants No.2021WGALH15)funding support by the Innovation and Technology Commission of Hong Kong SAR Government to the Hong Kong Branch of National Rail Transit Electrification and Automation Engineering Technology Research Center(Grant No.K-BBY1).
文摘The current technical standards primarily relied on experience to judge the interfacial bonding properties between the self-compacting concrete filling layer and the steam-cured concrete precast slab in CRTS Ⅲ slab ballastless track structure.This study sought to enhance technical standards for evaluating interfacial bonding properties by suggesting the use of the splitting tensile strength to evaluate the impact of bubble defects.Specimens were fabricated through on-site experiment.The percent of each area of 6 cm^(2)or more bubble defect was 0 in most of specimens.When the cumulative area of all bub-ble defects reached 12%,the splitting tensile strength value was 0.67 MPa,which exceeded the minimum required value of 0.5 MPa for ensuring bonding interface adhesion.Furthermore,when the cumulative area of all bubble defects reached 8%,the splitting tensile strength value was 0.85 MPa,which exceeded the minimum required value of 0.8 MPa,thereby over-coming the negative impact of each area of 10 cm^(2) or more bubble defect.Additionally,keeping the cumulative area of each area of 6 cm^(2) or more bubble defect below 6%ensured adequate bonding strength and reduced the occurrence of specimens with lower splitting tensile strength values.