Objective:To explore the value and effect of contrast-enhanced ultrasound in the diagnosis of breast lesions.Methods:Seventy-two patients with breast lesions in Shaanxi Provincial People’s Hospital from June 2020 to ...Objective:To explore the value and effect of contrast-enhanced ultrasound in the diagnosis of breast lesions.Methods:Seventy-two patients with breast lesions in Shaanxi Provincial People’s Hospital from June 2020 to December 2021 were selected as the research subjects.All 72 patients met the diagnostic criteria of breast lesions.Two patients with incomplete clinical data were excluded;hence,there were 70 patients remaining.The diagnostic results of the two examination methods and the diagnostic value of the joint examination for breast lesions were analyzed and compared.Results:The results of benign,malignant,missed,and misdiagnosed breast lesions by contrast-enhanced ultrasound were 31,32,6,and 1 cases,respectively,accounting for 44.29%,45.71%,8.57%,and 1.43%,respectively.The results of benign,malignant,missed,and misdiagnosed breast lesions by ultrasound automatic volume imaging were 21,24,17,and 8 cases,respectively,accounting for 30.00%,34.28%,24.29%,and 11.43%,respectively.There were statistical differences between the two groups for missed diagnosis and misdiagnosis,but there was no significant difference between the two groups for benign and malignant lesions.The accuracy,sensitivity,and specificity of contrast-enhanced ultrasound were 87.69%,83.62%,and 83.45%,respectively;the accuracy,sensitivity,and specificity of ultrasound automatic volume imaging were 71.39%,68.99%,and 74.69%,respectively;the accuracy,sensitivity,and specificity of contrast-enhanced ultrasound combined with ultrasound automatic volume imaging were 96.29%,92.68%,and 91.78%,respectively.Conclusion:Contrast-enhanced ultrasonography has a high clinical application value and a low inspection error rate in the diagnosis of breast lesions.It merits clinical advancement since it helps doctors diagnose and treat breast lesions more effectively.展开更多
A set of fountain solution system is designed, which can automatically adjust the concentration, pH value, temperature of the fountain solution in the printing process to ensure that the fountain solution system mixes...A set of fountain solution system is designed, which can automatically adjust the concentration, pH value, temperature of the fountain solution in the printing process to ensure that the fountain solution system mixes stable and qualified fountain solution and maintains a good balance of ink and water, thus improving the quality of printed products. The structure of the new fountain solution system mainly comprises a water inlet and medicine inlet system, a water tank circulation system, a water bucket and collection tank system, a refrigeration circulation system, a temperature control system and an automatic pH value detection and adjustment system of the fountain solution. The working flow and electrical control principle of the fountain solution system are described in detail. This paper focuses on the automatic detection and adjustment system of pH value of fountain solution, including the analysis of the control principle and process of the adjustment system, and the design and research of the pH master control system circuit and pH electrode signal measurement circuit.展开更多
针对继电保护整定值依赖人工经验计算导致实时性不足、易受数据不完整影响的问题,设计一种基于5G的继电保护整定值自动计算系统。该系统通过多源数据融合与完整性校验提高输入信息的准确性,依托5G超可靠低时延通信(Ultra-Reliable and L...针对继电保护整定值依赖人工经验计算导致实时性不足、易受数据不完整影响的问题,设计一种基于5G的继电保护整定值自动计算系统。该系统通过多源数据融合与完整性校验提高输入信息的准确性,依托5G超可靠低时延通信(Ultra-Reliable and Low-Latency Communication,URLLC)切片构建低时延传输通道,实现继电保护参数的实时交互,并结合数学建模与优化算法完成整定值的快速计算与远程下发。实验结果表明,该系统能够有效提升继电保护装置的自适应性与运行安全性。展开更多
文摘Objective:To explore the value and effect of contrast-enhanced ultrasound in the diagnosis of breast lesions.Methods:Seventy-two patients with breast lesions in Shaanxi Provincial People’s Hospital from June 2020 to December 2021 were selected as the research subjects.All 72 patients met the diagnostic criteria of breast lesions.Two patients with incomplete clinical data were excluded;hence,there were 70 patients remaining.The diagnostic results of the two examination methods and the diagnostic value of the joint examination for breast lesions were analyzed and compared.Results:The results of benign,malignant,missed,and misdiagnosed breast lesions by contrast-enhanced ultrasound were 31,32,6,and 1 cases,respectively,accounting for 44.29%,45.71%,8.57%,and 1.43%,respectively.The results of benign,malignant,missed,and misdiagnosed breast lesions by ultrasound automatic volume imaging were 21,24,17,and 8 cases,respectively,accounting for 30.00%,34.28%,24.29%,and 11.43%,respectively.There were statistical differences between the two groups for missed diagnosis and misdiagnosis,but there was no significant difference between the two groups for benign and malignant lesions.The accuracy,sensitivity,and specificity of contrast-enhanced ultrasound were 87.69%,83.62%,and 83.45%,respectively;the accuracy,sensitivity,and specificity of ultrasound automatic volume imaging were 71.39%,68.99%,and 74.69%,respectively;the accuracy,sensitivity,and specificity of contrast-enhanced ultrasound combined with ultrasound automatic volume imaging were 96.29%,92.68%,and 91.78%,respectively.Conclusion:Contrast-enhanced ultrasonography has a high clinical application value and a low inspection error rate in the diagnosis of breast lesions.It merits clinical advancement since it helps doctors diagnose and treat breast lesions more effectively.
文摘A set of fountain solution system is designed, which can automatically adjust the concentration, pH value, temperature of the fountain solution in the printing process to ensure that the fountain solution system mixes stable and qualified fountain solution and maintains a good balance of ink and water, thus improving the quality of printed products. The structure of the new fountain solution system mainly comprises a water inlet and medicine inlet system, a water tank circulation system, a water bucket and collection tank system, a refrigeration circulation system, a temperature control system and an automatic pH value detection and adjustment system of the fountain solution. The working flow and electrical control principle of the fountain solution system are described in detail. This paper focuses on the automatic detection and adjustment system of pH value of fountain solution, including the analysis of the control principle and process of the adjustment system, and the design and research of the pH master control system circuit and pH electrode signal measurement circuit.
文摘针对继电保护整定值依赖人工经验计算导致实时性不足、易受数据不完整影响的问题,设计一种基于5G的继电保护整定值自动计算系统。该系统通过多源数据融合与完整性校验提高输入信息的准确性,依托5G超可靠低时延通信(Ultra-Reliable and Low-Latency Communication,URLLC)切片构建低时延传输通道,实现继电保护参数的实时交互,并结合数学建模与优化算法完成整定值的快速计算与远程下发。实验结果表明,该系统能够有效提升继电保护装置的自适应性与运行安全性。