期刊文献+
共找到226篇文章
< 1 2 12 >
每页显示 20 50 100
10 kV小电源接入系统的保护配置及故障解列实例研究
1
作者 唐蕾蕾 《移动信息》 2025年第4期326-328,335,共4页
With the continuous development of distributed power sources,the number of 10kV small power sources connected to the grid is gradually increasing.It is necessary to pay attention to the relevant protection configurati... With the continuous development of distributed power sources,the number of 10kV small power sources connected to the grid is gradually increasing.It is necessary to pay attention to the relevant protection configurations and fault disconnection methods of their access systems to ensure the safe and stable operation of the local power grid in the region.This paper analyzes the relay protection configuration of a small power source connected to the power grid through an example of a 10kV energy switch station in Shanghai,at the same time,it analyzed how the fault disconnection device operates and how it cooperates with the backup automatic switch to ensure the safe and stable operation of the power grid and small power sources when faults occur on the power grid or small power source side. 展开更多
关键词 10 kV Small power supply protection configuration TROUBLESHOOTING Backup automatic switch
在线阅读 下载PDF
面向客舱系统的G.8032以太环网保护技术研究
2
作者 李俊生 杜稀晖 +2 位作者 刘毅 伍兴艳 胡林瑶 《民用飞机设计与研究》 2025年第1期81-88,共8页
以太环网具有减少飞机布线、易维护和易扩展等优点,已应用于飞机客舱系统网络中。但由于以太环网存在广播风暴风险,需引用以太环网保护技术。分析了国内外的以太环网保护技术特点和不足。由于当前客舱系统环网中采用的STP/RSTP以太环网... 以太环网具有减少飞机布线、易维护和易扩展等优点,已应用于飞机客舱系统网络中。但由于以太环网存在广播风暴风险,需引用以太环网保护技术。分析了国内外的以太环网保护技术特点和不足。由于当前客舱系统环网中采用的STP/RSTP以太环网保护技术不满足客舱系统网络承载旅客广播、客舱内话和乘客音视频等应用所需的毫秒级环网保护要求,因此,需要对客舱系统以太环网保护的收敛性能进行改进。提出了基于G.8032标准的客舱系统以太环网保护技术解决方案,介绍了ITU-T G.8032/Y1344(简称G.8032)以太环网保护协议的工作原理、消息和协议状态机,以及对环网保护的收敛性能进行了验证。最后针对G.8032协议中FDB(filtering database)刷新导致的数据洪泛,提出了减少过滤数据库刷新的方法,解决了客舱系统以太环网保护时存在的数据洪泛问题。G.8032协议支持单环网和多环互连的组网,支持备份链路,具有小于50 ms的环网保护性能。改进后的G.8032以太环网保护技术可以满足客舱系统应用需求。 展开更多
关键词 以太环网保护 环网保护链路 虚拟局域网 自动保护倒换 过滤数据库
在线阅读 下载PDF
基于智能站的远方链式备自投保护改造方案研究
3
作者 邓正臣 王彤彤 +2 位作者 李宝国 杨峥 韩晔 《农村电气化》 2025年第5期4-7,共4页
针对部分地区主网均采用就地备自投保护装置,且部分母线出线不具备互投功能的问题,提出了一种基于智能站体系下的新型远方链式备自投保护装置;考虑了变电站链式接线下多站间的备自投保护动作逻辑设计及改造方案,可以在不改动现有网络架... 针对部分地区主网均采用就地备自投保护装置,且部分母线出线不具备互投功能的问题,提出了一种基于智能站体系下的新型远方链式备自投保护装置;考虑了变电站链式接线下多站间的备自投保护动作逻辑设计及改造方案,可以在不改动现有网络架构的基础上实现信息流传输,同时可以进一步压缩某些特定故障后的停电时间,能够有效提高供电可靠性。 展开更多
关键词 链式接线 备自投 智能变电站 保护改造
在线阅读 下载PDF
基于PCE的光层ASON网络可靠性提升策略研究
4
作者 周凌尧 《通信电源技术》 2025年第7期222-224,共3页
针对大规模自动交换光网络(Automatically Switched Optical Network,ASON)中传统分布式算路存在的资源冲突和性能瓶颈问题,提出基于路径计算节点(Path Computation Element,PCE)架构的优化方案。通过预置路径实时计算机制实现故障前全... 针对大规模自动交换光网络(Automatically Switched Optical Network,ASON)中传统分布式算路存在的资源冲突和性能瓶颈问题,提出基于路径计算节点(Path Computation Element,PCE)架构的优化方案。通过预置路径实时计算机制实现故障前全量与增量路径预规划,采用集中与分布式协同算路策略保障50 ms级响应时效,构建异地PCE容灾保护体系确保系统可靠性。该方案能够有效解决多业务重路由冲突,提高带宽利用率,并将主备切换时延控制在毫秒级,为光层ASON网络的智能化演进提供技术支撑。 展开更多
关键词 自动交换光网络(ASON) 路径计算节点(PCE) 预置路径 容灾保护
在线阅读 下载PDF
对消防电气几个问题的探讨
5
作者 宋建峰 《上海节能》 2025年第6期908-913,共6页
研究旨在按照GB 50016-2014《建筑设计防火规范》中与消防电气有关的条款内容,分析探讨火灾探测器及火灾自动报警系统的设置、阻燃电缆及三级负荷消防用电设备装置切换等几个方面的问题。当前业内对上述问题的处理协调的意见并不统一,... 研究旨在按照GB 50016-2014《建筑设计防火规范》中与消防电气有关的条款内容,分析探讨火灾探测器及火灾自动报警系统的设置、阻燃电缆及三级负荷消防用电设备装置切换等几个方面的问题。当前业内对上述问题的处理协调的意见并不统一,在实践中会遇到分歧,因此在遵循上述规定的前提下,结合工作经历,对其进行了阐述,并呼吁《建筑设计防火规范》编制组在后续的改进升级中,能够对一些技术和文字表达不当之处在充分调研的基础上进行精确修改,为中国建筑工程的消防安全保驾护航。 展开更多
关键词 建筑设计防火 宜设置 矿物绝缘电缆 三级负荷 自动切换装置
在线阅读 下载PDF
全自动运行线路人员安全防护策略应用研究
6
作者 赵文文 《铁道通信信号》 2025年第6期71-77,共7页
城市轨道交通全自动运行(FAO)线路严格划分了自动化区域与非自动化区域。为确保自动化区域内人员的作业安全,结合全自动运行系统的特点及运营场景需求,信号系统中设置有人员防护开关(SPKS),并将SPKS工作状态纳入信号联锁系统的控制检查... 城市轨道交通全自动运行(FAO)线路严格划分了自动化区域与非自动化区域。为确保自动化区域内人员的作业安全,结合全自动运行系统的特点及运营场景需求,信号系统中设置有人员防护开关(SPKS),并将SPKS工作状态纳入信号联锁系统的控制检查条件;同时,信号系统与门禁系统实现联动控制,结合运营组织管理模式,共同保障人员安全及运营效率。以西安地铁8号环线工程实施方案为例,结合不同运营场景,针对岛式、侧式车站布置和配线设置,以及车辆段站场型式,提出全自动运行线路SPKS的设置方式。经现场验证,在无人值守的全自动运行模式下该人员安全防护策略可解决轨旁作业人员的安全防护问题,有效规避行车过程人员误入自动化区域的风险,符合信号系统的故障导向安全原则。 展开更多
关键词 人员防护开关 城市轨道交通 全自动运行 信号系统 联动控制 人员安全防护策略
在线阅读 下载PDF
Active dynamic pre-protection mechanism for MPLS-TP network 被引量:1
7
作者 白晖峰 Ji Yuefeng 《High Technology Letters》 EI CAS 2011年第4期354-359,共6页
The active-fault-alarm (AFA) technologies and the dynamic protection mechanism of the optical network controlled by the multi-protocol label switching transport profile (MPLS-TP) are both studied in this article. ... The active-fault-alarm (AFA) technologies and the dynamic protection mechanism of the optical network controlled by the multi-protocol label switching transport profile (MPLS-TP) are both studied in this article. On this basis, an active dynamic pre-protection (ADPP) mechanism is proposed. This active dynamic pre-protection mechanism is allowed to establish a so called temporary protection path (TPP) for the work path before a potential fault occurs and to switch to TPP only after the fault occurs. It keeps the TPP flexibly only when it is in low- quality or fault state to realize dynamic protection even better and to achieve better resource utilization. Simulation results show that the proposed new mechanism has better performance in terms of the flexibility and the efficiency from the perspective of time. 展开更多
关键词 multiple protocol label switching transport profile (MPLS-TP) active-fault-alarm (AFA) network protection
在线阅读 下载PDF
Integrated dynamic shared protection algorithm for GMPLS networks
8
作者 Wang Yan Zeng Jiazhi 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第6期1264-1271,共8页
The path protection approach is widely investigated as a survivability solution for GMPLS networks, which has the advantage of efficient capacity utilization. However, there is a problem of the path protection approac... The path protection approach is widely investigated as a survivability solution for GMPLS networks, which has the advantage of efficient capacity utilization. However, there is a problem of the path protection approach that searching a disjoint backup path for a primary path is often unsuccessful. In order to resolve this problem, an integrated dynamic shared protection (IDSP) algorithm is proposed. The main idea of the proposed algorithm is that the path protection approach is first used to establish a backup path for the primary path; if the establishment is unsuccessful, then the primary path is dynamically divided into segments whose hop count are not fixed but not more than the limitation calculated by the equations introduced. In this proposal, backup bandwidth sharing is allowed to improve the capacity utilization ratio, which makes the link cost function quite different from previous ones. Simulation experiments are presented to demonstrate the efficiency of the proposed method compared with previous methods. Numerical results show that IDSP can not only achieve low protection failure probability but can also gain a better tradeoff between the protection overbuild and the average recovery time. 展开更多
关键词 generalized multi-protocol label switching protectION hop count primary path backup path
在线阅读 下载PDF
地下污水处理厂消防切非原则的讨论 被引量:1
9
作者 卢晔楠 郭韬 郑效文 《天津建设科技》 2024年第5期40-42,共3页
针对地下污水处理厂在发生火灾时切断非消防用电源的关键问题,从分类消防负荷及分析工艺流程的角度出发,通过对多个实际工程案例的分析和国家规范的探讨,提出了相应的设计原则和解决方案。
关键词 地下污水处理厂 消防切非 火灾自动报警系统 电气设计
在线阅读 下载PDF
继电保护测试仪自动检测系统设计
10
作者 韩春雪 李艳萍 +1 位作者 罗东岳 刘业春 《自动化仪表》 CAS 2024年第3期45-48,54,共5页
继电保护测试仪是对继电保护装置调试和检验的重要仪器。为了进一步提高继电保护测试仪的检测精度、稳定性和检测效率,设计了基于LabVIEW的继电保护测试仪自动检测系统。该系统采用LabVIEW模块化的编程思想,实现继电保护测试仪的自动检... 继电保护测试仪是对继电保护装置调试和检验的重要仪器。为了进一步提高继电保护测试仪的检测精度、稳定性和检测效率,设计了基于LabVIEW的继电保护测试仪自动检测系统。该系统采用LabVIEW模块化的编程思想,实现继电保护测试仪的自动检测、手动检测、保存报告等功能。为了解决继电保护测试仪的输出为三相,而万用表和示波器仅支持单相测试的问题,设计了输出转换装置。基于转换装置,可以在测试开始前一次性完成所有接线,并在测试过程中根据不同校准项目进行测试回路自动切换。功能测试结果表明,该系统能满足检验标准化、报告标准化和闭环自动测试要求。该系统对其他二次测量设备的自动检测校准有一定的借鉴意义。 展开更多
关键词 继电保护测试仪 LABVIEW 自动检测 自动回路切换 输出转换装置
在线阅读 下载PDF
卫星导航抗干扰射频单板自动化测试系统 设计与实现 被引量:3
11
作者 吴海龙 宋合 杨坤 《计算技术与自动化》 2024年第2期1-9,共9页
针对卫星导航抗干扰射频单板人工测试过程较复杂且难以快速批量测试的问题,提出了基于C#与STM32的卫星导航抗干扰射频单板自动化测试系统。首先,通过自动化测试软件与STM32主控制器数据通信控制射频开关电路进行数据采集,然后将采集数... 针对卫星导航抗干扰射频单板人工测试过程较复杂且难以快速批量测试的问题,提出了基于C#与STM32的卫星导航抗干扰射频单板自动化测试系统。首先,通过自动化测试软件与STM32主控制器数据通信控制射频开关电路进行数据采集,然后将采集数据与多次人工测试结果对比分析,形成多项校准参数并应用于测试系统,最后通过批量测试验证系统测试结果准确性。通过批量试验数据证明各项测量指标误差均小于2.5%,测试效率较人工测试提升至少3.3倍,具有较高测量精度和效率。同时,该自动化测试系统对测试单板有过压过流保护功能,能有效保护被测单板不被损坏,综合整体性能具有良好的应用前景。 展开更多
关键词 过流保护 射频开关 数据采集 数据通信 自动化测试
在线阅读 下载PDF
主变低压侧区内单相接地保护分析及引起负荷损失的思考 被引量:2
12
作者 朱晓东 冯宗建 +1 位作者 王其林 郑润蓝 《农村电气化》 2024年第2期39-42,共4页
110 kV主变10 kV低压侧母线桥发生一起区内单相接地,仅有接地变保护动作跳闸变低开关且闭锁备自投,造成负荷损失。母线桥接地故障一直持续至运行人员手动切除主变高压侧断路器,故障存在扩大的隐患。文章对故障期间主变差动、主变高低后... 110 kV主变10 kV低压侧母线桥发生一起区内单相接地,仅有接地变保护动作跳闸变低开关且闭锁备自投,造成负荷损失。母线桥接地故障一直持续至运行人员手动切除主变高压侧断路器,故障存在扩大的隐患。文章对故障期间主变差动、主变高低后备保护、接地变和备自投动作行为进行分析,确认相关保护动作行为的正确性。为避免主变区内故障引起负荷损失,提出备自投采用变低自产零序电流反闭锁的判据优化方案。为及时切除故障避免故障扩大,提出备自投跳闸变低联跳变高的动作优化,对提高电源可靠性和设备安全性具有积极参考意义。 展开更多
关键词 主变 单相接地 接地变 备自投 差动保护 后备保护
在线阅读 下载PDF
适应分布式新能源并网的变电站备自投及保护方式改进 被引量:1
13
作者 石琳琳 《电站系统工程》 2024年第5期57-59,共3页
随着油田建设的持续发展,对电力供应的稳定性提出了更高要求。为解决油田变电站高度分散和供电稳定性问题,分布式新能源并网方式因其自身优势得到广泛的应用。随着我国石油领域分布式电源装机及并网容量迅速增大,其相关建设和保障问题... 随着油田建设的持续发展,对电力供应的稳定性提出了更高要求。为解决油田变电站高度分散和供电稳定性问题,分布式新能源并网方式因其自身优势得到广泛的应用。随着我国石油领域分布式电源装机及并网容量迅速增大,其相关建设和保障问题也日益受到业内重视。目前,变电站备自投以及保护方式的完善等,成为油田电力保障的关键性技术,是避免变电站发生合闸不同步、进而引发故障的一种重要手段。通过深入分析,对相关内容能够有更准确认识和把握。 展开更多
关键词 分布式新能源并网 变电站备自投 保护 改进
原文传递
关于消防供电末端双切在核电厂核岛的适用性分析
14
作者 刘千里 孙辉 《智能建筑电气技术》 2024年第5期3-7,共5页
《建筑防火通用规范》GB 55037—2022要求重要消防设备应在其配电线路的最末一级配电箱内设置自动切换装置。对核电厂核岛和常规民用建筑消防供电的现状进行对比分析,阐述核电厂核岛消防供电设置末端自动切换装置可能带来的风险,结合对... 《建筑防火通用规范》GB 55037—2022要求重要消防设备应在其配电线路的最末一级配电箱内设置自动切换装置。对核电厂核岛和常规民用建筑消防供电的现状进行对比分析,阐述核电厂核岛消防供电设置末端自动切换装置可能带来的风险,结合对规范条文的溯源及各行业执行情况和经验反馈,提出替代性满足通规的建议。 展开更多
关键词 可靠性 消防供电 自动切换装置 供电通道 共模点
原文传递
继电保护系统在变电系统失压中的智能自动切换策略分析
15
作者 符光凯 《集成电路应用》 2024年第12期96-97,共2页
阐述变电站继电保护系统在全站失压情景下的智能自动切换策略。提出一种基于智能算法的自动切换方案,能够在全站失压时高效地保护电力设备和维持系统稳定运行,并通过仿真实验进行验证。
关键词 继电保护系统 全站失压 智能自动切换
在线阅读 下载PDF
基于自动交换光网络的电力通信传输网络优化方法
16
作者 单志伟 《通信电源技术》 2024年第17期119-121,共3页
针对电力系统智能化发展对电力通信网络提出的新需求,文章提出一种基于自动交换光网络(Automatic Switched Optical Network,ASON)的电力通信传输网络优化方法。该方法涵盖网络拓扑发现与管理、智能路由与波长分配、动态连接管理以及网... 针对电力系统智能化发展对电力通信网络提出的新需求,文章提出一种基于自动交换光网络(Automatic Switched Optical Network,ASON)的电力通信传输网络优化方法。该方法涵盖网络拓扑发现与管理、智能路由与波长分配、动态连接管理以及网络保护与恢复等环节,通过将智能控制与高速传输紧密结合,实现网络资源的灵活调度和业务的可靠承载。 展开更多
关键词 自动交换光网络(ASON) 动态连接管理 网络保护与恢复
在线阅读 下载PDF
基于冷凝水再利用的空调器散热方法研究
17
作者 石磊 《电子测试》 2024年第6期83-86,共4页
为响应国家“双碳”战略,解决传统空调器冷凝器风冷散热效率低、冷凝水浪费严重的问题,提出一种基于冷凝水再利用的空调器散热优化方法。该方法集成冷凝水淋洒、风扇打水蒸发冷却和底盘水腔浸泡3种散热方式,设计以浮子开关和电磁阀为核... 为响应国家“双碳”战略,解决传统空调器冷凝器风冷散热效率低、冷凝水浪费严重的问题,提出一种基于冷凝水再利用的空调器散热优化方法。该方法集成冷凝水淋洒、风扇打水蒸发冷却和底盘水腔浸泡3种散热方式,设计以浮子开关和电磁阀为核心的自动控制逻辑,实现冷凝水按需分流与循环利用。通过热力学建模(如蒸发潜热换热模型、风扇风速与蒸发速率关系模型)与控制策略优化,搭建实验系统验证。结果表明,在典型高温高湿环境下,冷凝器散热效率提升15.6%,整机能耗降低约8.3%。系统具备完善的故障保护(如水位预警、压缩机启停控制)与容错恢复功能,且改造成本低(批量采购下80~120元/台)、适配主流空调机型,为绿色制冷设备研发提供可行路径,对空调行业节能转型具有重要推动作用。 展开更多
关键词 冷凝水回收再利用 空调器 冷凝器 节能散热 自动控制(浮子开关-电磁阀联动) 热力学建模 故障保护
在线阅读 下载PDF
基于IEC61850标准的网络化备自投功能 被引量:25
18
作者 李海星 王政涛 +1 位作者 王锐 曹丽璐 《电力系统保护与控制》 EI CSCD 北大核心 2009年第14期82-85,共4页
当前在电力系统中,备自投功能大多采用专门的备自投装置完成。通过信号电缆获得开关、刀闸位置信息,通过交流采集回路将交流量传给备自投装置,最后由备自投装置完成运行方式的识别和动作逻辑判别,动作逻辑输出经电缆传输给相应的开关,... 当前在电力系统中,备自投功能大多采用专门的备自投装置完成。通过信号电缆获得开关、刀闸位置信息,通过交流采集回路将交流量传给备自投装置,最后由备自投装置完成运行方式的识别和动作逻辑判别,动作逻辑输出经电缆传输给相应的开关,完成开关的分合。在传统的保护方案中,需要在现场安装较多的信号电缆以及交流采集回路,接线复杂,并且每一个备投点都需要设置独立的保护装置,成本较高。提出一种基于GOOSE方式的网络化备自投功能,能够直接应用到以IEC61850标准为基础建立起来的数字化变电站中,具有较大的实用价值。 展开更多
关键词 GOOSE 备自投 IEC61850 数字化变电站 网络化保护
在线阅读 下载PDF
WDM环形网络保护时间评估与优化分析 被引量:5
19
作者 林绵锋 刘雪原 +1 位作者 方来付 顾畹仪 《光子学报》 EI CAS CSCD 2000年第7期626-632,共7页
本文用逻辑等效方法分析了使用 1∶ 1保护配置的 WDM环行网络的保护倒换规程 ,并且对需要信令协调的 WDM环行网络的保护时间进行了分析 ,得到了保护时间的表达式 .在分析各种因素对保护时间影响的基础上 ,提出了优化的思路 .
关键词 WDM环形网络 优化设计 全光网络 保护时间
在线阅读 下载PDF
基于GMPLS的自动交换光网络生存性技术研究 被引量:3
20
作者 崔延军 胡秀兰 +1 位作者 陈晓益 顾婉仪 《量子电子学报》 CAS CSCD 北大核心 2005年第5期794-798,共5页
能够提供高效快速的生存性是自动交换光网络的重要特点。介绍了自动交换光网络的生存性实现的过程和各种生存性机制,提出了基于通用多协议标签交换的自动交换光网络中标签交换路径端到端生存性的实现方案,并对恢复的时间具体的分析。
关键词 光通信 自动交换光网络 通用多协议标签交换 保护 恢复
在线阅读 下载PDF
上一页 1 2 12 下一页 到第
使用帮助 返回顶部