In the anticorrosive coating line of a welded tube plant, the current status and existing problems of the medium-frequency induction heating equipment were discussed.Partial renovations of the power control cabinet ha...In the anticorrosive coating line of a welded tube plant, the current status and existing problems of the medium-frequency induction heating equipment were discussed.Partial renovations of the power control cabinet have been conducted.Parameters such as the DC current, DC voltage, intermediate frequency power, heating temperature, and the positioning signal at the pipe end were collected.A data acquisition and processing system, which can process data according to user needs and provide convenient data processing functions, has been developed using LabVIEW software.This system has been successfully applied in the coating line for the automatic control of high-power induction heating equipment, production management, and digital steel tube and/or digital delivery.展开更多
A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nu...A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nuclei.The digital data acquisition system enables precise synchronization and processing of complex signals from various detectors,such as plastic scintillators,silicon detectors,and germaniumγdetectors.The system's performance was evaluated using theβdecay of^(32)Ar and its neighboring nuclei,produced via projectile fragmentation at the first Radioactive Ion Beam Line in Lanzhou(RIBLL1).Key measurements,including the half-life,charged-particle spectrum,andγ-ray spectrum,were obtained and compared with previous results for validation.Using the implantation–decay method,the isotopes of interest were implanted into two doublesided silicon strip detectors,where their subsequent decays were measured and correlated with preceding implantations using both position and time information.This detection system has potential for further applications,including the study ofβ-delayed charged-particle decay and direct proton emissions from even more exotic proton-rich nuclei.展开更多
This article introduces the methodologies and instrumentation for data measurement and propagation at the Back-n white neutron facility of the China Spallation Neutron Source.The Back-n facility employs backscattering...This article introduces the methodologies and instrumentation for data measurement and propagation at the Back-n white neutron facility of the China Spallation Neutron Source.The Back-n facility employs backscattering techniques to generate a broad spectrum of white neutrons.Equipped with advanced detectors such as the light particle detector array and the fission ionization chamber detector,the facility achieves high-precision data acquisition through a general-purpose electronics system.Data were managed and stored in a hierarchical system supported by the National High Energy Physics Science Data Center,ensuring long-term preservation and efficient access.The data from the Back-n experiments significantly contribute to nuclear physics,reactor design,astrophysics,and medical physics,enhancing the understanding of nuclear processes and supporting interdisciplinary research.展开更多
Opportunistic mobile crowdsensing(MCS)non-intrusively exploits human mobility trajectories,and the participants’smart devices as sensors have become promising paradigms for various urban data acquisition tasks.Howeve...Opportunistic mobile crowdsensing(MCS)non-intrusively exploits human mobility trajectories,and the participants’smart devices as sensors have become promising paradigms for various urban data acquisition tasks.However,in practice,opportunistic MCS has several challenges from both the perspectives of MCS participants and the data platform.On the one hand,participants face uncertainties in conducting MCS tasks,including their mobility and implicit interactions among participants,and participants’economic returns given by the MCS data platform are determined by not only their own actions but also other participants’strategic actions.On the other hand,the platform can only observe the participants’uploaded sensing data that depends on the unknown effort/action exerted by participants to the platform,while,for optimizing its overall objective,the platform needs to properly reward certain participants for incentivizing them to provide high-quality data.To address the challenge of balancing individual incentives and platform objectives in MCS,this paper proposes MARCS,an online sensing policy based on multi-agent deep reinforcement learning(MADRL)with centralized training and decentralized execution(CTDE).Specifically,the interactions between MCS participants and the data platform are modeled as a partially observable Markov game,where participants,acting as agents,use DRL-based policies to make decisions based on local observations,such as task trajectories and platform payments.To align individual and platform goals effectively,the platform leverages Shapley value to estimate the contribution of each participant’s sensed data,using these estimates as immediate rewards to guide agent training.The experimental results on real mobility trajectory datasets indicate that the revenue of MARCS reaches almost 35%,53%,and 100%higher than DDPG,Actor-Critic,and model predictive control(MPC)respectively on the participant side and similar results on the platform side,which show superior performance compared to baselines.展开更多
Dear Editor,Health management is essential to ensure battery performance and safety, while data-driven learning system is a promising solution to enable efficient state of health(SoH) estimation of lithium-ion(Liion) ...Dear Editor,Health management is essential to ensure battery performance and safety, while data-driven learning system is a promising solution to enable efficient state of health(SoH) estimation of lithium-ion(Liion) batteries. However, the time-consuming signal data acquisition and the lack of interpretability of model still hinder its efficient deployment. Motivated by this, this letter proposes a novel and interpretable data-driven learning strategy through combining the benefits of explainable AI and non-destructive ultrasonic detection for battery SoH estimation. Specifically, after equipping battery with advanced ultrasonic sensor to promise fast real-time ultrasonic signal measurement, an interpretable data-driven learning strategy named generalized additive neural decision ensemble(GANDE) is designed to rapidly estimate battery SoH and explain the effects of the involved ultrasonic features of interest.展开更多
The embedded data acquistition technology in vehicle electronic system was discussed. This technology adopts the parallel working mode, gets vehicle electronic system data by communication. This technology can provide...The embedded data acquistition technology in vehicle electronic system was discussed. This technology adopts the parallel working mode, gets vehicle electronic system data by communication. This technology can provide us a lot of information on the electronic control unit, is very useful for the development of the vehicle electronic system, and can be used in diagnosis. The key points to this technology are the timer interrupt, A/D interrupt, communication interrupt and real time operation. This technology has been validated by the application in the electronic control mechanism transmission shifting system of the tank.展开更多
A data acquisition system based on LabVIEW and NI PXI-5105 is presented for multi-channel data acquisition. It can realize the functions of parameter setting, data acquisition and storage, waveform display and data an...A data acquisition system based on LabVIEW and NI PXI-5105 is presented for multi-channel data acquisition. It can realize the functions of parameter setting, data acquisition and storage, waveform display and data analysis using LabVIEW and NI-SCOPE device driver. The advantages of the system are that the setting is convenient, the operation is easy, the interface is friendly and the functions are practical. The experiment results show that the system has good stability and high reliability and is a powerful tool for multi-channel data acquisition.展开更多
The interleaving/multiplexing technique was used to realize a 200?MHz real time data acquisition system. Two 100?MHz ADC modules worked parallelly and every ADC plays out data in ping pang fashion. The design improv...The interleaving/multiplexing technique was used to realize a 200?MHz real time data acquisition system. Two 100?MHz ADC modules worked parallelly and every ADC plays out data in ping pang fashion. The design improved the system conversion rata to 200?MHz and reduced the speed of data transporting and storing to 50?MHz. The high speed HDPLD and ECL logic parts were used to control system timing and the memory address. The multi layer print board and the shield were used to decrease interference produced by the high speed circuit. The system timing was designed carefully. The interleaving/multiplexing technique could improve the system conversion rata greatly while reducing the speed of external digital interfaces greatly. The design resolved the difficulties in high speed system effectively. The experiment proved the data acquisition system is stable and accurate.展开更多
Data acquisition, analysis and calibrating system affiliated with the vehicle is developed for the research on the automatic shift system (ASS). Considering the vehicle’s hard environment such as vibration, high and ...Data acquisition, analysis and calibrating system affiliated with the vehicle is developed for the research on the automatic shift system (ASS). Considering the vehicle’s hard environment such as vibration, high and low temperature, electromagnetic disturbance and so on, the most suitable project is selected. PC104 transfers data with ECU by serial communication and a solid state disk is used as a FLASH ROM. Some techniques including frequency division of data is adopted in the software design in order to ensure the sampling frequency. The analysis and debug software is also contrived according to the characteristic of the ASS. The system plays an important role in the development of the ASS because of the good reliability and practicability in the application.展开更多
As the key ion source component of nuclear fusion auxiliary heating devices, the radio frequency (RF) ion source is developed and applied gradually to offer a source plasma with the advantages of ease of control and...As the key ion source component of nuclear fusion auxiliary heating devices, the radio frequency (RF) ion source is developed and applied gradually to offer a source plasma with the advantages of ease of control and high reliability. In addition, it easily achieves long-pulse steady-state operation. During the process of the development and testing of the RF ion source, a lot of original experimental data will be generated. Therefore, it is necessary to develop a stable and reliable computer data acquisition and processing application system for realizing the functions of data acquisition, storage, access, and real-time monitoring. In this paper, the development of a data acquisition and processing application system for the RF ion source is presented. The hardware platform is based on the PXI system and the software is programmed on the LabVIEW development environment. The key technologies that are used for the implementation of this software programming mainly include the long-pulse data acquisition technology, multi- threading processing technology, transmission control communication protocol, and the Lempel-Ziv-Oberhumer data compression algorithm. Now, this design has been tested and applied on the RF ion source. The test results show that it can work reliably and steadily. With the help of this design, the stable plasma discharge data of the RF ion source are collected, stored, accessed, and monitored in real-time. It is shown that it has a very practical application significance for the RF experiments.展开更多
A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cr...A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion.展开更多
Neutral beam injection (NBI) heating is one of the most efficient auxiliary plasma heating methods for fusion devices. The data acquisition control system (DACS) with PXI (pe- ripheral component interconnect exte...Neutral beam injection (NBI) heating is one of the most efficient auxiliary plasma heating methods for fusion devices. The data acquisition control system (DACS) with PXI (pe- ripheral component interconnect extensions for instrumentation) data acquisition card for the first NBI system in the experimental advanced superconducting tokamak (EAST) is presented in this paper. As an important sub-system, DACS is designed to obtain physical measurement signals in the EAST NBI system and to deal and store these data with the Lempel-Ziv-Oberhumer (LZO) lossless data compression algorithm, as well as offer convenient data call-back and access inter- faces to the user for examining and analyzing the data. Experimental results show that accurate data will ensure that researchers correctly analyze it and then properly adjust the experimental parameters or operation, so DACS should take a large step in improving experimental efficiency. Tile hardware and software sections are briefly presented in this paper, and now this system has been tested to be able to work reliably and steadily.展开更多
With the development of current electronic technology, numerous high-speed data acquisition systems provide a variety of potential benefits. This article describes a high-speed data acquisition system which consists o...With the development of current electronic technology, numerous high-speed data acquisition systems provide a variety of potential benefits. This article describes a high-speed data acquisition system which consists of ECL logic and TTL logic devices, samples and stores data with a 1 GHz clock. This system is accomplished easily and works stably. A performance test of this system has been undertaken and the results show that the effective number of bits (ENOB) is more than 6.5 bits.展开更多
The increasing network throughput challenges the current network traffic monitor systems to have compatible high-performance data processing.The design of packet processing systems is guided by the requirements of hig...The increasing network throughput challenges the current network traffic monitor systems to have compatible high-performance data processing.The design of packet processing systems is guided by the requirements of high packet processing throughput.In this paper,we depict an in-depth research on the related techniques and an implementation of a high-performance data acquisition mechanism.Through the bottleneck analysis with the aid of queuing network model,several performance optimising methods,such as service rate increasing,queue removing and model simplification,are integrated.The experiment results indicate that this approach is capable of reducing the CPU utilization ratio while improving the efficiency of data acquisition in high-speed networks.展开更多
A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and en...A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and energy,and visualization of various spectra.In comparison to the conventional resonance nuclear reaction system,the key technique is the precise synchronization of the detected counts with the actual scanning voltage(or probing laser frequency).The functions of the system were tested by measuring the hyperfine structure spectra of stable calcium(e.g.,^(40)Ca^(+))and radioactive potassium(e.g.,^(38)K)in the bunched and continuous modes,respectively.This system will be routinely applied and further improved in subsequent laser spectroscopy experiments on unstable isotopes at the Beijing Radioactive Ion-beam Facility(BRIF).展开更多
A data acquisition system for testing gas sensor array response to multi-gas is presented.The testing system is based on the character of the gas response of metal oxide semiconductor gas sensor array.The data acquisi...A data acquisition system for testing gas sensor array response to multi-gas is presented.The testing system is based on the character of the gas response of metal oxide semiconductor gas sensor array.The data acquisition is realized automatically through the real time controlling of the data acquisition card PCI1711.This system is highly attractive for electronic nose,which is a powerful tool for the discrimination of gases.展开更多
A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of p...A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension positionsensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out(FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown.展开更多
To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber de...To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber detectors and fast controller technology,has been developed for neutron flux monitor in ITER Equatorial Port#7.The signal processing units which arc based on a field programmable gate array and the PXI Express platform arc designed to realize the neutron flux measurement with I ms time resolution and a fast response less than 0.2 ms,together with real-time timestamps provided by a timing hoard.The application of the wide-range algorithm allows the system to measure up to 10^10cps with a relative error of less than 5%.Furthermore,the system is managed and controlled by a software based on the Experimental Physics and Industrial Control System,compliant with COntrol.Data Access and Communication architecture.展开更多
In this paper,a monitoring and controlling system for the safety in production and environmental parameters of a small and medium-sized coal mine has been developed after analyzing the current domestic coal production...In this paper,a monitoring and controlling system for the safety in production and environmental parameters of a small and medium-sized coal mine has been developed after analyzing the current domestic coal production and security conditions. The client computer can convert the analog signal about the safety in production and environmental parameters detected from the monitoring terminal into digital signal,and then,send the signal to the coal mine safety monitoring centre. This information can be analyzed,judged,and diagnosed by the monitoring-management-controlling software for helping the manager and technical workers to control the actual underground production and security situations. The system has many advantages including high reliability,better performance of real-time monitoring,faster data communicating and good practicability,and it can effectively prevent the occurrence of safety incidents in coal mines.展开更多
Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physi...Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data acquisition is synchronized with a clock and trigger provided by the central timing system.展开更多
文摘In the anticorrosive coating line of a welded tube plant, the current status and existing problems of the medium-frequency induction heating equipment were discussed.Partial renovations of the power control cabinet have been conducted.Parameters such as the DC current, DC voltage, intermediate frequency power, heating temperature, and the positioning signal at the pipe end were collected.A data acquisition and processing system, which can process data according to user needs and provide convenient data processing functions, has been developed using LabVIEW software.This system has been successfully applied in the coating line for the automatic control of high-power induction heating equipment, production management, and digital steel tube and/or digital delivery.
基金supported by the National Key Research and Development Project,China(No.2023YFA1606404)the Strategic Priority Research Program of Chinese Academy of Sciences(No.XDB34010300)+5 种基金the National Natural Science Foundation of China(Nos.12022501,12105329,12475127)the Guangdong Major Project of Basic and Applied Basic Research(No.2021B0301030006)the Research Program of Heavy Ion Science and Technology Key Laboratory,Institute of Modern Physics,Chinese Academy of Sciences(Nos.HIST2024KS04,HIST2024CO04)Longyuan Youth Innovation and Entrepreneurship Talent Project of Gansu Province(No.2024GZT04)State Key Laboratory of Nuclear Physics and Technology,Peking University(No.NPT2023KFY01)the Major Science and Technology Projects in Gansu Province(No.24GD13GA005)。
文摘A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nuclei.The digital data acquisition system enables precise synchronization and processing of complex signals from various detectors,such as plastic scintillators,silicon detectors,and germaniumγdetectors.The system's performance was evaluated using theβdecay of^(32)Ar and its neighboring nuclei,produced via projectile fragmentation at the first Radioactive Ion Beam Line in Lanzhou(RIBLL1).Key measurements,including the half-life,charged-particle spectrum,andγ-ray spectrum,were obtained and compared with previous results for validation.Using the implantation–decay method,the isotopes of interest were implanted into two doublesided silicon strip detectors,where their subsequent decays were measured and correlated with preceding implantations using both position and time information.This detection system has potential for further applications,including the study ofβ-delayed charged-particle decay and direct proton emissions from even more exotic proton-rich nuclei.
基金supported by the National Key Research and Development Plan(No.2023YFA1606602)。
文摘This article introduces the methodologies and instrumentation for data measurement and propagation at the Back-n white neutron facility of the China Spallation Neutron Source.The Back-n facility employs backscattering techniques to generate a broad spectrum of white neutrons.Equipped with advanced detectors such as the light particle detector array and the fission ionization chamber detector,the facility achieves high-precision data acquisition through a general-purpose electronics system.Data were managed and stored in a hierarchical system supported by the National High Energy Physics Science Data Center,ensuring long-term preservation and efficient access.The data from the Back-n experiments significantly contribute to nuclear physics,reactor design,astrophysics,and medical physics,enhancing the understanding of nuclear processes and supporting interdisciplinary research.
基金sponsored by Qinglan Project of Jiangsu Province,and Jiangsu Provincial Key Research and Development Program(No.BE2020084-1).
文摘Opportunistic mobile crowdsensing(MCS)non-intrusively exploits human mobility trajectories,and the participants’smart devices as sensors have become promising paradigms for various urban data acquisition tasks.However,in practice,opportunistic MCS has several challenges from both the perspectives of MCS participants and the data platform.On the one hand,participants face uncertainties in conducting MCS tasks,including their mobility and implicit interactions among participants,and participants’economic returns given by the MCS data platform are determined by not only their own actions but also other participants’strategic actions.On the other hand,the platform can only observe the participants’uploaded sensing data that depends on the unknown effort/action exerted by participants to the platform,while,for optimizing its overall objective,the platform needs to properly reward certain participants for incentivizing them to provide high-quality data.To address the challenge of balancing individual incentives and platform objectives in MCS,this paper proposes MARCS,an online sensing policy based on multi-agent deep reinforcement learning(MADRL)with centralized training and decentralized execution(CTDE).Specifically,the interactions between MCS participants and the data platform are modeled as a partially observable Markov game,where participants,acting as agents,use DRL-based policies to make decisions based on local observations,such as task trajectories and platform payments.To align individual and platform goals effectively,the platform leverages Shapley value to estimate the contribution of each participant’s sensed data,using these estimates as immediate rewards to guide agent training.The experimental results on real mobility trajectory datasets indicate that the revenue of MARCS reaches almost 35%,53%,and 100%higher than DDPG,Actor-Critic,and model predictive control(MPC)respectively on the participant side and similar results on the platform side,which show superior performance compared to baselines.
基金supported by the National Natural Science Foundation of China(62373224,62333013,U23A20327)the Natural Science Foundation of Shandong Province(ZR2024JQ021)
文摘Dear Editor,Health management is essential to ensure battery performance and safety, while data-driven learning system is a promising solution to enable efficient state of health(SoH) estimation of lithium-ion(Liion) batteries. However, the time-consuming signal data acquisition and the lack of interpretability of model still hinder its efficient deployment. Motivated by this, this letter proposes a novel and interpretable data-driven learning strategy through combining the benefits of explainable AI and non-destructive ultrasonic detection for battery SoH estimation. Specifically, after equipping battery with advanced ultrasonic sensor to promise fast real-time ultrasonic signal measurement, an interpretable data-driven learning strategy named generalized additive neural decision ensemble(GANDE) is designed to rapidly estimate battery SoH and explain the effects of the involved ultrasonic features of interest.
文摘The embedded data acquistition technology in vehicle electronic system was discussed. This technology adopts the parallel working mode, gets vehicle electronic system data by communication. This technology can provide us a lot of information on the electronic control unit, is very useful for the development of the vehicle electronic system, and can be used in diagnosis. The key points to this technology are the timer interrupt, A/D interrupt, communication interrupt and real time operation. This technology has been validated by the application in the electronic control mechanism transmission shifting system of the tank.
文摘A data acquisition system based on LabVIEW and NI PXI-5105 is presented for multi-channel data acquisition. It can realize the functions of parameter setting, data acquisition and storage, waveform display and data analysis using LabVIEW and NI-SCOPE device driver. The advantages of the system are that the setting is convenient, the operation is easy, the interface is friendly and the functions are practical. The experiment results show that the system has good stability and high reliability and is a powerful tool for multi-channel data acquisition.
文摘The interleaving/multiplexing technique was used to realize a 200?MHz real time data acquisition system. Two 100?MHz ADC modules worked parallelly and every ADC plays out data in ping pang fashion. The design improved the system conversion rata to 200?MHz and reduced the speed of data transporting and storing to 50?MHz. The high speed HDPLD and ECL logic parts were used to control system timing and the memory address. The multi layer print board and the shield were used to decrease interference produced by the high speed circuit. The system timing was designed carefully. The interleaving/multiplexing technique could improve the system conversion rata greatly while reducing the speed of external digital interfaces greatly. The design resolved the difficulties in high speed system effectively. The experiment proved the data acquisition system is stable and accurate.
文摘Data acquisition, analysis and calibrating system affiliated with the vehicle is developed for the research on the automatic shift system (ASS). Considering the vehicle’s hard environment such as vibration, high and low temperature, electromagnetic disturbance and so on, the most suitable project is selected. PC104 transfers data with ECU by serial communication and a solid state disk is used as a FLASH ROM. Some techniques including frequency division of data is adopted in the software design in order to ensure the sampling frequency. The analysis and debug software is also contrived according to the characteristic of the ASS. The system plays an important role in the development of the ASS because of the good reliability and practicability in the application.
基金the NBI team and the partial support of National Natural Science Foundation of China (No. 61363019)National Natural Science Foundation of Qinghai Province (No. 2014-ZJ-718)
文摘As the key ion source component of nuclear fusion auxiliary heating devices, the radio frequency (RF) ion source is developed and applied gradually to offer a source plasma with the advantages of ease of control and high reliability. In addition, it easily achieves long-pulse steady-state operation. During the process of the development and testing of the RF ion source, a lot of original experimental data will be generated. Therefore, it is necessary to develop a stable and reliable computer data acquisition and processing application system for realizing the functions of data acquisition, storage, access, and real-time monitoring. In this paper, the development of a data acquisition and processing application system for the RF ion source is presented. The hardware platform is based on the PXI system and the software is programmed on the LabVIEW development environment. The key technologies that are used for the implementation of this software programming mainly include the long-pulse data acquisition technology, multi- threading processing technology, transmission control communication protocol, and the Lempel-Ziv-Oberhumer data compression algorithm. Now, this design has been tested and applied on the RF ion source. The test results show that it can work reliably and steadily. With the help of this design, the stable plasma discharge data of the RF ion source are collected, stored, accessed, and monitored in real-time. It is shown that it has a very practical application significance for the RF experiments.
基金supported by the National Key R&D Program of China(No.2018YFA0404403)the National Natural Science Foundation of China(Nos.12035001,12075006,11675003)the State Key Laboratory of Nuclear Physics and Technology,PKU(No.NPT2020KFY18)。
文摘A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion.
基金supported by National Natural Science Foundation of China(No.11075183)
文摘Neutral beam injection (NBI) heating is one of the most efficient auxiliary plasma heating methods for fusion devices. The data acquisition control system (DACS) with PXI (pe- ripheral component interconnect extensions for instrumentation) data acquisition card for the first NBI system in the experimental advanced superconducting tokamak (EAST) is presented in this paper. As an important sub-system, DACS is designed to obtain physical measurement signals in the EAST NBI system and to deal and store these data with the Lempel-Ziv-Oberhumer (LZO) lossless data compression algorithm, as well as offer convenient data call-back and access inter- faces to the user for examining and analyzing the data. Experimental results show that accurate data will ensure that researchers correctly analyze it and then properly adjust the experimental parameters or operation, so DACS should take a large step in improving experimental efficiency. Tile hardware and software sections are briefly presented in this paper, and now this system has been tested to be able to work reliably and steadily.
文摘With the development of current electronic technology, numerous high-speed data acquisition systems provide a variety of potential benefits. This article describes a high-speed data acquisition system which consists of ECL logic and TTL logic devices, samples and stores data with a 1 GHz clock. This system is accomplished easily and works stably. A performance test of this system has been undertaken and the results show that the effective number of bits (ENOB) is more than 6.5 bits.
基金ACKNOWLEDGEMENT This project was supported by the National Natural Science Foundation of China under Grant No. 61170262 the National High Tech- nology Research and Development Program of China (863 Program) under Grants No. 2012AA012506, No. 2012AA012901, No. 2012- AA012903+5 种基金 the Specialised Research Fund for the Doctoral Program of Higher Education of China under Grant No. 20121103120032 the Humanity and Social Science Youth Founda- tion of Ministry of Education of China under Grant No. 13YJCZH065 the Opening Project of Key Lab of Information Network Security of Ministry of Public Security (The Third Re- search Institute of Ministry of Public Security) under Grant No. C13613 the China Postdoc- toral Science Foundation, General Program of Science and Technology Development Project of Beijing Municipal Education Commission of China under Grant No. km201410005012 the Research on Education and Teaching of Beijing University of Technology under Grant No. ER2013C24 the Beijing Municipal Natu- ral Science Foundation, Sponsored by Hunan Postdoctoral Scientific Program, Open Re- search Fund of Beijing Key Laboratory of Trusted Computing.
文摘The increasing network throughput challenges the current network traffic monitor systems to have compatible high-performance data processing.The design of packet processing systems is guided by the requirements of high packet processing throughput.In this paper,we depict an in-depth research on the related techniques and an implementation of a high-performance data acquisition mechanism.Through the bottleneck analysis with the aid of queuing network model,several performance optimising methods,such as service rate increasing,queue removing and model simplification,are integrated.The experiment results indicate that this approach is capable of reducing the CPU utilization ratio while improving the efficiency of data acquisition in high-speed networks.
基金supported by the National Natural Science Foundation of China (Nos.12027809,U1967201,11875073,11875074 and 11961141003)National Key R&D Program of China (No.2018YFA0404403)the State Key Laboratory of Nuclear Physics and Technology,Peking University (Nos.NPT2019ZZ02,NPT2020KFY17).
文摘A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and energy,and visualization of various spectra.In comparison to the conventional resonance nuclear reaction system,the key technique is the precise synchronization of the detected counts with the actual scanning voltage(or probing laser frequency).The functions of the system were tested by measuring the hyperfine structure spectra of stable calcium(e.g.,^(40)Ca^(+))and radioactive potassium(e.g.,^(38)K)in the bunched and continuous modes,respectively.This system will be routinely applied and further improved in subsequent laser spectroscopy experiments on unstable isotopes at the Beijing Radioactive Ion-beam Facility(BRIF).
文摘A data acquisition system for testing gas sensor array response to multi-gas is presented.The testing system is based on the character of the gas response of metal oxide semiconductor gas sensor array.The data acquisition is realized automatically through the real time controlling of the data acquisition card PCI1711.This system is highly attractive for electronic nose,which is a powerful tool for the discrimination of gases.
基金National Natural Science Foundation of China (Nos. 10134010 and 10004010)
文摘A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension positionsensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out(FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown.
文摘To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber detectors and fast controller technology,has been developed for neutron flux monitor in ITER Equatorial Port#7.The signal processing units which arc based on a field programmable gate array and the PXI Express platform arc designed to realize the neutron flux measurement with I ms time resolution and a fast response less than 0.2 ms,together with real-time timestamps provided by a timing hoard.The application of the wide-range algorithm allows the system to measure up to 10^10cps with a relative error of less than 5%.Furthermore,the system is managed and controlled by a software based on the Experimental Physics and Industrial Control System,compliant with COntrol.Data Access and Communication architecture.
基金supported by Technologies R&D of State Administration of Work Safety (06-399)Technologies R&D of Hunan Province ( No.05FJ4071)
文摘In this paper,a monitoring and controlling system for the safety in production and environmental parameters of a small and medium-sized coal mine has been developed after analyzing the current domestic coal production and security conditions. The client computer can convert the analog signal about the safety in production and environmental parameters detected from the monitoring terminal into digital signal,and then,send the signal to the coal mine safety monitoring centre. This information can be analyzed,judged,and diagnosed by the monitoring-management-controlling software for helping the manager and technical workers to control the actual underground production and security situations. The system has many advantages including high reliability,better performance of real-time monitoring,faster data communicating and good practicability,and it can effectively prevent the occurrence of safety incidents in coal mines.
文摘Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data acquisition is synchronized with a clock and trigger provided by the central timing system.