Dear Editor,In this case,we discuss a teenager who experienced severe eye pain and elevated intraocular pressure(IOP)caused by reverse pupillary block,which was successfully resolved using Neodymium-doped yttrium alum...Dear Editor,In this case,we discuss a teenager who experienced severe eye pain and elevated intraocular pressure(IOP)caused by reverse pupillary block,which was successfully resolved using Neodymium-doped yttrium aluminum garnet(Nd:YAG)laser peripheral iridotomy(LPI).展开更多
AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: Th...AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: The seventeen patients (7 male and 10 female; mean age 67.8 years) with difficult common bile duct (CBD) stones were not amenable for conventional endoscopic maneuvers such as sphincterotomy and mechanical lithotripsy were included in this study. Laser wavelengths of 532 nm and 1064 nm as a double pulse were applied with pulse energy of 120 mJ. The laser fiber was advanced under fluoroscopic control through the ERCP balloon catheter. Laser lithotripsy was continued until the fragment size seemed to be less than 10 mm. Endoscopic extraction of the stones and fragments was performed with the use of the Dormia basket and balloon catheter. RESULTS: Bile duct clearance was achieved in 15 of 17 patients (88%). The mean number of treatment sessions was 1.7 ± 0.6. Endoscopic stone removal could not be achieved in 2 patients (7%). Adverse effects were noted in three patients (hemobilia, pancreatitis, and cholangitis). CONCLUSION: The Frequency Doubled Double Pulse Nd:YAG (FREDDY) laser may be an effective and safe technique in treatment of difficult bile duct stones.展开更多
YAG laser welding with surface activating flux has been investigated, and the influencing factors and mechanism are discussed. The results show that both surface activating flux and surface active element S have fanta...YAG laser welding with surface activating flux has been investigated, and the influencing factors and mechanism are discussed. The results show that both surface activating flux and surface active element S have fantastic effects on the YAG laser weld shape, that is to obviously increase the weld penetration and D/W ratio in various welding conditions. The mechanism is thought to be the change of weld pool surface tension temperature coefficient, thus, the change of fluid flow pattern in weld pool due to the flux.展开更多
Objective To prospectively evaluate the efficacy of Removing Stasis and Reducing Heat Formula in accelerating calculus clearance and improving lower urinary tract symptoms of patients with proximal ureteral calculi af...Objective To prospectively evaluate the efficacy of Removing Stasis and Reducing Heat Formula in accelerating calculus clearance and improving lower urinary tract symptoms of patients with proximal ureteral calculi after ureteroscopic Ho:YAG laser lithotripsy. Methods A total of 138 patients with proximal ureteral calculi underwent ureteroscopic Ho:YAG laser lithotripsy by a single endocrinologist. Stone size varied from 10 to 15 mm. After operation, the patients were randomly divided into three groups: the control group(group A), tamsulosin group(group B), and Removing Stasis and Reducing Heat Formula group(group C). The treatment lasted for 4 weeks or until stone clearance. The primary and secondary outcomes of the three groups at follow-up were assessed. Results Of the 131 patients available for follow-up, 44 cases were in the group A, 45 in the group B, and 42 in the group C, respectively. The stone free rate at 2 weeks in the groups B and C were significantly higher than that in the group A(95.56%, 97.62% vs. 79.55%; all P<0.05). The ureteral colic rate and mean time of fragment expulsion were significantly reduced in the groups B(4.44% and 7.86±4.99 days) and C(2.43% and 6.76±4.37 days) compared with the group A(22.73% and 11.54±9.89 days, all P<0.05). On the day of double-J ureteric stent removal, the group C differed significantly from the group A in the total International Prostate Symptom Score, irritative subscore, obstructive subscore, and quality of life score(all P<0.05). Conclusion Removing Stasis and Reducing Heat Formula in the medical expulsive therapy might be an effective modality for patients with calculus in the proximal uretera after ureteroscopic Ho:YAG laser lithotripsy.展开更多
AIM:To investigate the effects of a new opening pattern in neodymium:yttrium-aluminum-garnet(Nd:YAG)laser posterior capsulotomy on visual function.METHODS:This technique was conducted along a circular pattern.The ener...AIM:To investigate the effects of a new opening pattern in neodymium:yttrium-aluminum-garnet(Nd:YAG)laser posterior capsulotomy on visual function.METHODS:This technique was conducted along a circular pattern.The energy ranged between 0.8 and1.2 mJ/pulse was consumed and mean total energy levels were 74±21 mJ(mean±standard deviation:SD,from 40 to167)and laser shots aimed at 150μm away behind a datum point and went along an imaginary line which extends 0.5 mm inside from optic margin and into the circular en bloc pattern.Vitreous stands were attached with fragment and then they were cut off by the laser after circular application.The circular fragment was completely separated from vitreous,and then this fragment was quickly sunk in intravitreal space.RESULTS:The follow-up period ranges from at least a week to 40mo,making 15.8mo on average.The procedural outcome showed 96%(74 eyes out of the 77eyes)enhancement in patients’visual acuity.Cystoid macular edema or retinal detachment was not observed in any of the patients during follow-up periods.CONCLUSION:This new technique is expected to improve the weaknesses that the conventional procedures have by adding the process to cut off vitreous stands attached with the fragment by the laser to the circular application.展开更多
BACKGROUND Routine preclinical interventions for patients with chronic periodontitis such as supragingival cleaning and subgingival curettage,establishing a balanced occlusal relationship,and irrigation with 3%hydroge...BACKGROUND Routine preclinical interventions for patients with chronic periodontitis such as supragingival cleaning and subgingival curettage,establishing a balanced occlusal relationship,and irrigation with 3%hydrogen peroxide can relieve the symptoms to some extent.However,there is room for improvement in the overall effect.For example,Er:YAG lasers can quickly increase the temperature of the irradiated tissue,effectively eliminate dental plaque and calculus,reduce periodontal pockets,adjust periodontal microecology,and reduce the gingival sulcus.The content of factors in the liquid,and then achieve the purpose of treatment.AIM The aim was evaluate the effect of Er:YAG laser-assisted routine therapy on the periodontal status in chronic periodontitis.METHODS Between October 2018 and January 2020,106 patients with chronic periodontitis in our hospital were randomly assigned to either the study or control group,with 53 patients in each group.The control group underwent routine therapy,and the study group underwent Er:YAG laser therapy in addition to routine therapy.We evaluated the treatment outcome in both groups.Periodontal status was determined by clinical attachment loss(CAL),gingival index(GI),periodontal probing depth(PD),dental plaque index(PLI),and sulcular bleeding index(SBI),inflammatory factors in the gingival crevicular fluid,tumor necrosis factor-α(TNF-α),interleukin-6(IL-6),IL-8],and colony forming units(CFUs).RESULTS Total effectiveness in the study group(94.34%)was higher than that in the control group(79.25%,P<0.05).The clinical parameters in the study group(PD,5.28±1.08 mm;CAL,4.81±0.79 mm;SBI,3.37±0.59;GI,1.38±0.40;PLI,2.05±0.65)were not significantly different from those in the control group(PD,5.51±1.14 mm;CAL,5.09±0.83 mm;SBI,3.51±0.62;GI,(1.41±0.37;PLI,1.98±0.70)before treatment(P>0.05).However,after treatment,the parameters in the study group(PD,2.97±0.38 mm;CAL,2.71±0.64 mm;SBI,2.07±0.32;GI,0.51±0.11;PLI,1.29±0.34)were lower than those in the control group(PD,3.71±0.42 mm;CAL,3.60±0.71 mm;SBI,2.80±0.44;GI,0.78±0.23;PLI,1.70±0.51)(P<0.05).Differences in crevicular TNF-α,IL-6,and IL-8 levels in the study(TNF-α,7.82±3.43 ng/mL;IL-6,11.67±2.59 ng/mL;IL-8,12.12±3.19 pg/mL)and control groups(TNF-α,9.06±3.89 ng/ml,IL-6,12.13±2.97 ng/mL,IL-8,10.99±3.30 pg/mL)before therapy(P>0.05)were not significant.Following treatment,the parameters were significantly lower in the study group(TNF-α,2.04±0.89 ng/mL;IL-6,4.60±1.26 ng/mL;IL-8,3.15±1.08 pg/mL)than in the control group(TNF-α,3.11±1.07 ng/mL;IL-6,6.25±1.41 ng/mL;IL-8,4.64±1.23 pg/mL,P<0.05).The difference in the CFU of the study group[(367.91±74.32)×104/mL and control group(371.09±80.25)×104/mL]before therapy was not significant(P>0.05).The CFU decreased in both groups following therapy,however,the CFU values were lower in the study group[(36.09±15.26)×104/mL]than in the control group[(45.89±18.08)×104/mL](P<0.05).CONCLUSION Combining Er:YAG lasers with routine measures significantly improved the overall periodontal therapy outcomes by improving periodontal status and reducing oral levels of inflammatory factors and CFUs.展开更多
A pulsed Nd:YAG (yttrium aluminum garnet) laser-based technique was employed to clad low silicon steel with preplaced Si and Fe mixed powders for high Si content. The surface morphology, microstructural evolution, ...A pulsed Nd:YAG (yttrium aluminum garnet) laser-based technique was employed to clad low silicon steel with preplaced Si and Fe mixed powders for high Si content. The surface morphology, microstructural evolution, phase composition, and Si distribution, within the obtained cladding coatings, were characterized by optical microscopy (OM), field emission scanning electron microscopy (FE-SEM), with associated energy dispersive spectroscopy (EDS), transmission electron microscopy (TEM), and X-ray diffraction (XRD). The microhardness was also measured along the depth direction of the specimens, A crack- and pore-free cladding coating through excellent metallurgical bonding with the substrate was successfully prepared on low silicon steel by means of optimized single-track and multi-track laser cladding. The phases of the coating are a-Fe, T-Fe, and FeSi. The high microhardness of the lasercladding zone is considered as an increase in Si content and as the refined microstructure produced by the laser treatment. The Si contents of the cladding coatings were about 5.8wt% in the single-track cladding and 6.5wt% in the multi-track cladding, respectively.展开更多
The objective of the this study is to investigate the effects of cutting parameters on thermal characteristics, including practical cutting regions, the formation of the kerfwidth and the heat transfer phenomenon, in ...The objective of the this study is to investigate the effects of cutting parameters on thermal characteristics, including practical cutting regions, the formation of the kerfwidth and the heat transfer phenomenon, in the cutting of Inconel 718 super-alloy sheets using a CW Nd:YAG laser. From the results of the experiments, the influence of process parameters on both the practical cutting region and the kerfwidth has been examined. In addition, it has been shown that the kerfwidth of the specimen lies in the range of 0.53-0.61 mm. In order to examine characteristics of the heat transfer during the laser cutting process, a three-dimensional quasi-steady heat transfer analysis has been performed using the commercial code SYSWELD V9.0. From the results of the analysis, the influence of cutting parameters on the temperature distribution in the vicinity of the cut section has been quantitatively evaluated. Based on these results, optimal cutting conditions have been estimated.展开更多
Summary: The effectiveness and safety of ureteroscopic holmium:YAG laser lithotripsy for managing ureteral calculi was evaluated. Ureteroscopic holmium:YAG laser lithotripsy was performed in 168 ureteral calculi (uppe...Summary: The effectiveness and safety of ureteroscopic holmium:YAG laser lithotripsy for managing ureteral calculi was evaluated. Ureteroscopic holmium:YAG laser lithotripsy was performed in 168 ureteral calculi (upper 27 cases, middle 33 cases and lower 108 cases). The results showed that the stone-free rate was 92.6 % in the upper ureteral calculi, 93.9 % in the middle ureteral calculi and 94.4 % in the lower ureteral calculi, respectively. The complication rate was 4.8 % (8 cases). It was suggested that ureteroscopic holmium:YAG laser lithotripsy is a highly effective and safe treatment modality for managing ureteral calculi.展开更多
Spectroscopic properties of flashlamp pumped Nd^3+:YAG laser are studied as a function of temperature in a range from-30℃ to 60℃. The spectral width and shift of quasi three-level 946.0-nm inter-Stark emission wit...Spectroscopic properties of flashlamp pumped Nd^3+:YAG laser are studied as a function of temperature in a range from-30℃ to 60℃. The spectral width and shift of quasi three-level 946.0-nm inter-Stark emission within the respective intermanifold transitions of ^4F3/2→^4I9/2are investigated. The 946.0-nm line shifts toward the shorter wavelength and broadens. In addition, the threshold power and slope efficiency of the 946.0-nm laser line are quantified with temperature.The lower the temperature, the lower the threshold power is and the higher the slope efficiency of the 946.0-nm laser line is,thus the higher the laser output is. This phenomenon is attributed to the ion-phonon interaction and the thermal population in the ground state.展开更多
The main aim of this research is to optimize the tensile strength of laser welded FeCo-V alloy.A mathematicalrelationship was developed to predict tensile strength of the laser beam welded FeCo-V foils by incorporatin...The main aim of this research is to optimize the tensile strength of laser welded FeCo-V alloy.A mathematicalrelationship was developed to predict tensile strength of the laser beam welded FeCo-V foils by incorporating process parameterssuch as lamping current,welding speed,pulse duration and focused position.The procedure was established to improve the weldstrength and increase the productivity.The results indicate that the pulse duration and welding speed have the greatest influence ontensile strength.The obtained results showed that the tensile strength of the weld joints increase as a function of increasing pulseduration reaching to a maximum at a pulse duration value of2.25ms.Moreover,the tensile strength of joints increases with decreasein welding speed reaching to a maximum at a welding speed of125mm/min.It has been shown that increase in pulse duration anddecrease in welding speed result in increased effective peak power density and hence formation of more resistant welds.At higherpulse durations and lower welding speeds,the tensile strength of weld joints decreases because of formation of solidificationmicrocracks in the fusion zone.展开更多
AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, co...AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, comparative case series. Forty-five eyes of 34 patients underwent laser iridotomy. Twenty-two eyes underwent iridotomy using short duration PASCAL and Nd: YAG laser, and 23 eyes underwent iridotomy using conventional combined laser method. The average settings of PASCAL were60 μm and 700-900 m W with a short duration of 0.01 s to reduce the total applied energy. The conventional laser was 50 μm and 700-900 m W for 0.1s. After photocoagulation with these laser, the Nd: YAG laser was added in each group. Endothelial cell counts of preiridotomy and 2mo after iridotomy were measured and compared.RESULTS: All eyes completed iridotomy successfully.The total energy used in the PASCAL group was 1.85 ±1.17 J. Compared to conventional laser 13.25 ±1.67 J, the energy used was very small due to the short exposure time of PASCAL. Endothelial cell counts were reduced by0.88% in the PASCAL group and 6.72% in the conventional laser group(P =0.044). The change in corneal endothelial cell counts before and after iridotomy was significant in conventional combined laser iridotomy group(P =0.004).CONCLUSION: Combined PASCAL and Nd:YAG laseriridotomy is an effective and safe technique in the dark brown irides of Asians. Furthermore, the short duration of exposure in PASCAL offers the advantages of reducing the total energy used and minimizing the corneal damage.展开更多
A diode-end-pumped Q-switched high-efficiency Nd, Cr:YAG laser with simultaneous dual-wavelength emission at 946nm and 1.3μm is demonstrated. The maximum output power of 1.93 W with simultaneous dual-wavelength oper...A diode-end-pumped Q-switched high-efficiency Nd, Cr:YAG laser with simultaneous dual-wavelength emission at 946nm and 1.3μm is demonstrated. The maximum output power of 1.93 W with simultaneous dual-wavelength operation is achieved at an absorbed pump power of 13.32 W and an absorbed slope efficiency of 15.15%. The maximum optical-optical efficiency is 14.49% with pulse widths of 16.38ns at 946nm and 26.65ns at 1.3μm. A maximum total repetition rate of 43.25 kHz is obtained.展开更多
The effects of picosecond Nd:YAG laser irradiation on chemical and morphological surface characteristics of the commercially pure titanium and Ti–13Nb–13Zr alloy in air and argon atmospheres were studied under diffe...The effects of picosecond Nd:YAG laser irradiation on chemical and morphological surface characteristics of the commercially pure titanium and Ti–13Nb–13Zr alloy in air and argon atmospheres were studied under different laser output energy values.During the interaction of laser irradiation with the investigated materials,a part of the energy was absorbed on the target surface,influencing surface modifications.Laser beam interaction with the target surface resulted in various morphological alterations,resulting in crater formation and the presence of microcracks and hydrodynamic structures.Moreover,different chemical changes were induced on the target materials’surfaces,resulting in the titanium oxide formation in the irradiation-affected area and consequently increasing the irradiation energy absorption.Given the high energy absorption at the site of interaction,the dimensions of the surface damaged area increased.Consequently,surface roughness increased.The appearance of surface oxides also led to the increased material hardness in the surface-modified area.Observed chemical and morphological changes were pronounced after laser irradiation of the Ti–13Nb–13Zr alloy surface.展开更多
Objective To investigate the method of emergent relief of special renal colic and treatment of ureter diseases causing renal colic. Methods By analyzing 63 cases of special renal colic treated with ureteroscope and ...Objective To investigate the method of emergent relief of special renal colic and treatment of ureter diseases causing renal colic. Methods By analyzing 63 cases of special renal colic treated with ureteroscope and Holmium YAG laser. Results 61 cases of renal colic were relieved in a short period of time and the original ureter diseases causing renal colic were cured. Conclusion Special renal colic could be treated with ureteroscope and Holmium YAG laser in a quick and effective manner.展开更多
AIM:To assess the long-term efficacy and safety of yttrium-aluminum garnet(YAG)laser vitreolysis for vision degrading myodesopsia(VDM)caused by posterior vitreous detachment(PVD).METHODS:This retrospective study revie...AIM:To assess the long-term efficacy and safety of yttrium-aluminum garnet(YAG)laser vitreolysis for vision degrading myodesopsia(VDM)caused by posterior vitreous detachment(PVD).METHODS:This retrospective study reviewed VDM patients of PVD type undergoing YAG laser vitreolysis.The baseline demographic information,the patterns of floaters,the number of floaters,and the subjective improvement of floater sympotoms(ranging from 0 to 100%)from medical records were collected.Significant improvement was defined as a relief of floater symptoms of≥50%at the final visit.The long-term efficacy and safety of YAG laser vitreolysis were analyzed.The risk factors linked to significant improvement of floater symptoms were defined using univariate and multivariate logistic regression analyses.RESULTS:The final analysis included 221 patients with VDM.The mean age of patients was 61.08±7.74y,and the mean length of follow-up was 21.38±5.61mo.Totally 57.01%of patients experienced a significant improvement in their floater symptoms after YAG laser therapy,and none of them developed delayed retinal abnormalities such as retinal tears or detachments.Age(OR=1.049,95%CI=1.007-1.092,P=0.021)was identified as a significant risk factor for significant improvement in VDM.CONCLUSION:YAG laser vitreolysis is an effective and secure treatment for PVD-type VDM,and patients of advanced age are more likely to get favorable outcomes.展开更多
The effects of YAG laser welding conditions on mechanical properties andpress formability (bendability, stretch-formability and deep drawability) of high-strengthtransformation-induced plasticity-aided dual-phase (TDP...The effects of YAG laser welding conditions on mechanical properties andpress formability (bendability, stretch-formability and deep drawability) of high-strengthtransformation-induced plasticity-aided dual-phase (TDP) steel were investigated. Tensile tests andpress forming tests have been conducted for laser butt welded joints between two pieces of the samesteel. The tensile property and press formability were affected by the welding speed of 100 to1100mm/min and the energy of 6 to 9J/pulse. Excellent press formability was obtained with the energyof 6J/pulse and the welding speed of 300mm/min. It was concluded that the excellent weldability ofthe TDP steel can be ascribed to the weld joint formation.展开更多
By using a Nd: YAG laser welding system devised for transmitting continuous, rectangular and pulsed waveforms, comprehensive and deep investigation is focused on the effects of several parameters of rectangular wavefo...By using a Nd: YAG laser welding system devised for transmitting continuous, rectangular and pulsed waveforms, comprehensive and deep investigation is focused on the effects of several parameters of rectangular waveform and pulsed output wave superimposed on a rectangular waveform on the penetration depth of weld. Research results indicate that the average power, duty cycle, frequency and peak power of rectangular wave affect the weld penetration depth to different extent. Results of experiments and analysis also indicate that the pulse delay time, pulse width and the power ratio of pulse to rectangular waveform seriously influence the penetration when the pulsed wave is superimposed on a rectangular waveform.展开更多
This study deals with Nd:YAG laser cutting nonmetallic materials, which is one of the most important and popular industrial applications of laser. The main theme is to evaluate the effects of Nd:YAG laser beam power...This study deals with Nd:YAG laser cutting nonmetallic materials, which is one of the most important and popular industrial applications of laser. The main theme is to evaluate the effects of Nd:YAG laser beam power besides work piece scanning speed. For approximate cutting depth, a theoretical study is conducted in terms of material property and cutting speed. Results show a nonlinear relation between the cutting depth and input energy. There is no significant effect of speed on cutting depth with the speed being larger than 30 mm/s. An extra energy is utilized in the deep cutting. It is inferred that as the laser power increases, cutting depth increases. The experimental outcomes are in good agreement with theoretical results. This analysis will provide a guideline for laser-based industry to select a suitable laser for cutting, scribing, trimming, engraving, and marking nonmetallic materials.展开更多
A high-power passively Q-switched Nd:YAG laser operating at lll2nm with Cr4+:yAO as a saturable absorber is demonstrated. Under 808 nm diode-direct pumping, the maximum average output power of 2.73 W is achieved at...A high-power passively Q-switched Nd:YAG laser operating at lll2nm with Cr4+:yAO as a saturable absorber is demonstrated. Under 808 nm diode-direct pumping, the maximum average output power of 2.73 W is achieved at the pump power of 16.65 W, corresponding to an optical-to-optical conversion efficiency of 16.4%. At the same time, the pulse width, pulse repetition rate, single pulse energy and peak power are 27.2ns, 9 kHz, 303.3#3 and 11.2kW, respectively. As far as we know, the result gives the highest average output power at 1112nm generated by an 808 nm diode-end-pumped Nd:YAG laser.展开更多
文摘Dear Editor,In this case,we discuss a teenager who experienced severe eye pain and elevated intraocular pressure(IOP)caused by reverse pupillary block,which was successfully resolved using Neodymium-doped yttrium aluminum garnet(Nd:YAG)laser peripheral iridotomy(LPI).
基金The 2007 research fund of Wonkwang University and Wonkwang Clinical Research Institute
文摘AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: The seventeen patients (7 male and 10 female; mean age 67.8 years) with difficult common bile duct (CBD) stones were not amenable for conventional endoscopic maneuvers such as sphincterotomy and mechanical lithotripsy were included in this study. Laser wavelengths of 532 nm and 1064 nm as a double pulse were applied with pulse energy of 120 mJ. The laser fiber was advanced under fluoroscopic control through the ERCP balloon catheter. Laser lithotripsy was continued until the fragment size seemed to be less than 10 mm. Endoscopic extraction of the stones and fragments was performed with the use of the Dormia basket and balloon catheter. RESULTS: Bile duct clearance was achieved in 15 of 17 patients (88%). The mean number of treatment sessions was 1.7 ± 0.6. Endoscopic stone removal could not be achieved in 2 patients (7%). Adverse effects were noted in three patients (hemobilia, pancreatitis, and cholangitis). CONCLUSION: The Frequency Doubled Double Pulse Nd:YAG (FREDDY) laser may be an effective and safe technique in treatment of difficult bile duct stones.
文摘YAG laser welding with surface activating flux has been investigated, and the influencing factors and mechanism are discussed. The results show that both surface activating flux and surface active element S have fantastic effects on the YAG laser weld shape, that is to obviously increase the weld penetration and D/W ratio in various welding conditions. The mechanism is thought to be the change of weld pool surface tension temperature coefficient, thus, the change of fluid flow pattern in weld pool due to the flux.
文摘Objective To prospectively evaluate the efficacy of Removing Stasis and Reducing Heat Formula in accelerating calculus clearance and improving lower urinary tract symptoms of patients with proximal ureteral calculi after ureteroscopic Ho:YAG laser lithotripsy. Methods A total of 138 patients with proximal ureteral calculi underwent ureteroscopic Ho:YAG laser lithotripsy by a single endocrinologist. Stone size varied from 10 to 15 mm. After operation, the patients were randomly divided into three groups: the control group(group A), tamsulosin group(group B), and Removing Stasis and Reducing Heat Formula group(group C). The treatment lasted for 4 weeks or until stone clearance. The primary and secondary outcomes of the three groups at follow-up were assessed. Results Of the 131 patients available for follow-up, 44 cases were in the group A, 45 in the group B, and 42 in the group C, respectively. The stone free rate at 2 weeks in the groups B and C were significantly higher than that in the group A(95.56%, 97.62% vs. 79.55%; all P<0.05). The ureteral colic rate and mean time of fragment expulsion were significantly reduced in the groups B(4.44% and 7.86±4.99 days) and C(2.43% and 6.76±4.37 days) compared with the group A(22.73% and 11.54±9.89 days, all P<0.05). On the day of double-J ureteric stent removal, the group C differed significantly from the group A in the total International Prostate Symptom Score, irritative subscore, obstructive subscore, and quality of life score(all P<0.05). Conclusion Removing Stasis and Reducing Heat Formula in the medical expulsive therapy might be an effective modality for patients with calculus in the proximal uretera after ureteroscopic Ho:YAG laser lithotripsy.
文摘AIM:To investigate the effects of a new opening pattern in neodymium:yttrium-aluminum-garnet(Nd:YAG)laser posterior capsulotomy on visual function.METHODS:This technique was conducted along a circular pattern.The energy ranged between 0.8 and1.2 mJ/pulse was consumed and mean total energy levels were 74±21 mJ(mean±standard deviation:SD,from 40 to167)and laser shots aimed at 150μm away behind a datum point and went along an imaginary line which extends 0.5 mm inside from optic margin and into the circular en bloc pattern.Vitreous stands were attached with fragment and then they were cut off by the laser after circular application.The circular fragment was completely separated from vitreous,and then this fragment was quickly sunk in intravitreal space.RESULTS:The follow-up period ranges from at least a week to 40mo,making 15.8mo on average.The procedural outcome showed 96%(74 eyes out of the 77eyes)enhancement in patients’visual acuity.Cystoid macular edema or retinal detachment was not observed in any of the patients during follow-up periods.CONCLUSION:This new technique is expected to improve the weaknesses that the conventional procedures have by adding the process to cut off vitreous stands attached with the fragment by the laser to the circular application.
基金by Qiqihar Science and Technology Bureau Social Development General Instruction Project,No.SFGG-201965.
文摘BACKGROUND Routine preclinical interventions for patients with chronic periodontitis such as supragingival cleaning and subgingival curettage,establishing a balanced occlusal relationship,and irrigation with 3%hydrogen peroxide can relieve the symptoms to some extent.However,there is room for improvement in the overall effect.For example,Er:YAG lasers can quickly increase the temperature of the irradiated tissue,effectively eliminate dental plaque and calculus,reduce periodontal pockets,adjust periodontal microecology,and reduce the gingival sulcus.The content of factors in the liquid,and then achieve the purpose of treatment.AIM The aim was evaluate the effect of Er:YAG laser-assisted routine therapy on the periodontal status in chronic periodontitis.METHODS Between October 2018 and January 2020,106 patients with chronic periodontitis in our hospital were randomly assigned to either the study or control group,with 53 patients in each group.The control group underwent routine therapy,and the study group underwent Er:YAG laser therapy in addition to routine therapy.We evaluated the treatment outcome in both groups.Periodontal status was determined by clinical attachment loss(CAL),gingival index(GI),periodontal probing depth(PD),dental plaque index(PLI),and sulcular bleeding index(SBI),inflammatory factors in the gingival crevicular fluid,tumor necrosis factor-α(TNF-α),interleukin-6(IL-6),IL-8],and colony forming units(CFUs).RESULTS Total effectiveness in the study group(94.34%)was higher than that in the control group(79.25%,P<0.05).The clinical parameters in the study group(PD,5.28±1.08 mm;CAL,4.81±0.79 mm;SBI,3.37±0.59;GI,1.38±0.40;PLI,2.05±0.65)were not significantly different from those in the control group(PD,5.51±1.14 mm;CAL,5.09±0.83 mm;SBI,3.51±0.62;GI,(1.41±0.37;PLI,1.98±0.70)before treatment(P>0.05).However,after treatment,the parameters in the study group(PD,2.97±0.38 mm;CAL,2.71±0.64 mm;SBI,2.07±0.32;GI,0.51±0.11;PLI,1.29±0.34)were lower than those in the control group(PD,3.71±0.42 mm;CAL,3.60±0.71 mm;SBI,2.80±0.44;GI,0.78±0.23;PLI,1.70±0.51)(P<0.05).Differences in crevicular TNF-α,IL-6,and IL-8 levels in the study(TNF-α,7.82±3.43 ng/mL;IL-6,11.67±2.59 ng/mL;IL-8,12.12±3.19 pg/mL)and control groups(TNF-α,9.06±3.89 ng/ml,IL-6,12.13±2.97 ng/mL,IL-8,10.99±3.30 pg/mL)before therapy(P>0.05)were not significant.Following treatment,the parameters were significantly lower in the study group(TNF-α,2.04±0.89 ng/mL;IL-6,4.60±1.26 ng/mL;IL-8,3.15±1.08 pg/mL)than in the control group(TNF-α,3.11±1.07 ng/mL;IL-6,6.25±1.41 ng/mL;IL-8,4.64±1.23 pg/mL,P<0.05).The difference in the CFU of the study group[(367.91±74.32)×104/mL and control group(371.09±80.25)×104/mL]before therapy was not significant(P>0.05).The CFU decreased in both groups following therapy,however,the CFU values were lower in the study group[(36.09±15.26)×104/mL]than in the control group[(45.89±18.08)×104/mL](P<0.05).CONCLUSION Combining Er:YAG lasers with routine measures significantly improved the overall periodontal therapy outcomes by improving periodontal status and reducing oral levels of inflammatory factors and CFUs.
基金the National Natural Science Foundation of China (No.50474084).
文摘A pulsed Nd:YAG (yttrium aluminum garnet) laser-based technique was employed to clad low silicon steel with preplaced Si and Fe mixed powders for high Si content. The surface morphology, microstructural evolution, phase composition, and Si distribution, within the obtained cladding coatings, were characterized by optical microscopy (OM), field emission scanning electron microscopy (FE-SEM), with associated energy dispersive spectroscopy (EDS), transmission electron microscopy (TEM), and X-ray diffraction (XRD). The microhardness was also measured along the depth direction of the specimens, A crack- and pore-free cladding coating through excellent metallurgical bonding with the substrate was successfully prepared on low silicon steel by means of optimized single-track and multi-track laser cladding. The phases of the coating are a-Fe, T-Fe, and FeSi. The high microhardness of the lasercladding zone is considered as an increase in Si content and as the refined microstructure produced by the laser treatment. The Si contents of the cladding coatings were about 5.8wt% in the single-track cladding and 6.5wt% in the multi-track cladding, respectively.
基金supported by a grant-in-aid for Regional Innovation Center (RIC), New Technology Development and Research Center of Laser Application in Chosun University, from ITEP and MOICEpartly supported by the National Core Research Center Program from MOST and KOSEF (No.R15-2006-022-01001-0)
文摘The objective of the this study is to investigate the effects of cutting parameters on thermal characteristics, including practical cutting regions, the formation of the kerfwidth and the heat transfer phenomenon, in the cutting of Inconel 718 super-alloy sheets using a CW Nd:YAG laser. From the results of the experiments, the influence of process parameters on both the practical cutting region and the kerfwidth has been examined. In addition, it has been shown that the kerfwidth of the specimen lies in the range of 0.53-0.61 mm. In order to examine characteristics of the heat transfer during the laser cutting process, a three-dimensional quasi-steady heat transfer analysis has been performed using the commercial code SYSWELD V9.0. From the results of the analysis, the influence of cutting parameters on the temperature distribution in the vicinity of the cut section has been quantitatively evaluated. Based on these results, optimal cutting conditions have been estimated.
文摘Summary: The effectiveness and safety of ureteroscopic holmium:YAG laser lithotripsy for managing ureteral calculi was evaluated. Ureteroscopic holmium:YAG laser lithotripsy was performed in 168 ureteral calculi (upper 27 cases, middle 33 cases and lower 108 cases). The results showed that the stone-free rate was 92.6 % in the upper ureteral calculi, 93.9 % in the middle ureteral calculi and 94.4 % in the lower ureteral calculi, respectively. The complication rate was 4.8 % (8 cases). It was suggested that ureteroscopic holmium:YAG laser lithotripsy is a highly effective and safe treatment modality for managing ureteral calculi.
基金Project supported by Estahban Branch,Islamic Azad University
文摘Spectroscopic properties of flashlamp pumped Nd^3+:YAG laser are studied as a function of temperature in a range from-30℃ to 60℃. The spectral width and shift of quasi three-level 946.0-nm inter-Stark emission within the respective intermanifold transitions of ^4F3/2→^4I9/2are investigated. The 946.0-nm line shifts toward the shorter wavelength and broadens. In addition, the threshold power and slope efficiency of the 946.0-nm laser line are quantified with temperature.The lower the temperature, the lower the threshold power is and the higher the slope efficiency of the 946.0-nm laser line is,thus the higher the laser output is. This phenomenon is attributed to the ion-phonon interaction and the thermal population in the ground state.
文摘The main aim of this research is to optimize the tensile strength of laser welded FeCo-V alloy.A mathematicalrelationship was developed to predict tensile strength of the laser beam welded FeCo-V foils by incorporating process parameterssuch as lamping current,welding speed,pulse duration and focused position.The procedure was established to improve the weldstrength and increase the productivity.The results indicate that the pulse duration and welding speed have the greatest influence ontensile strength.The obtained results showed that the tensile strength of the weld joints increase as a function of increasing pulseduration reaching to a maximum at a pulse duration value of2.25ms.Moreover,the tensile strength of joints increases with decreasein welding speed reaching to a maximum at a welding speed of125mm/min.It has been shown that increase in pulse duration anddecrease in welding speed result in increased effective peak power density and hence formation of more resistant welds.At higherpulse durations and lower welding speeds,the tensile strength of weld joints decreases because of formation of solidificationmicrocracks in the fusion zone.
文摘AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, comparative case series. Forty-five eyes of 34 patients underwent laser iridotomy. Twenty-two eyes underwent iridotomy using short duration PASCAL and Nd: YAG laser, and 23 eyes underwent iridotomy using conventional combined laser method. The average settings of PASCAL were60 μm and 700-900 m W with a short duration of 0.01 s to reduce the total applied energy. The conventional laser was 50 μm and 700-900 m W for 0.1s. After photocoagulation with these laser, the Nd: YAG laser was added in each group. Endothelial cell counts of preiridotomy and 2mo after iridotomy were measured and compared.RESULTS: All eyes completed iridotomy successfully.The total energy used in the PASCAL group was 1.85 ±1.17 J. Compared to conventional laser 13.25 ±1.67 J, the energy used was very small due to the short exposure time of PASCAL. Endothelial cell counts were reduced by0.88% in the PASCAL group and 6.72% in the conventional laser group(P =0.044). The change in corneal endothelial cell counts before and after iridotomy was significant in conventional combined laser iridotomy group(P =0.004).CONCLUSION: Combined PASCAL and Nd:YAG laseriridotomy is an effective and safe technique in the dark brown irides of Asians. Furthermore, the short duration of exposure in PASCAL offers the advantages of reducing the total energy used and minimizing the corneal damage.
基金Supported by the National Basic Research Program of China under Grant No 2013CB632704
文摘A diode-end-pumped Q-switched high-efficiency Nd, Cr:YAG laser with simultaneous dual-wavelength emission at 946nm and 1.3μm is demonstrated. The maximum output power of 1.93 W with simultaneous dual-wavelength operation is achieved at an absorbed pump power of 13.32 W and an absorbed slope efficiency of 15.15%. The maximum optical-optical efficiency is 14.49% with pulse widths of 16.38ns at 946nm and 26.65ns at 1.3μm. A maximum total repetition rate of 43.25 kHz is obtained.
基金This work was financially supported by the Ministry of Education,Science and Technological Development of the Republic of Serbia through Project Nos.ON174004 and ON172019the PhD fellowship of Slađana Laketić.
文摘The effects of picosecond Nd:YAG laser irradiation on chemical and morphological surface characteristics of the commercially pure titanium and Ti–13Nb–13Zr alloy in air and argon atmospheres were studied under different laser output energy values.During the interaction of laser irradiation with the investigated materials,a part of the energy was absorbed on the target surface,influencing surface modifications.Laser beam interaction with the target surface resulted in various morphological alterations,resulting in crater formation and the presence of microcracks and hydrodynamic structures.Moreover,different chemical changes were induced on the target materials’surfaces,resulting in the titanium oxide formation in the irradiation-affected area and consequently increasing the irradiation energy absorption.Given the high energy absorption at the site of interaction,the dimensions of the surface damaged area increased.Consequently,surface roughness increased.The appearance of surface oxides also led to the increased material hardness in the surface-modified area.Observed chemical and morphological changes were pronounced after laser irradiation of the Ti–13Nb–13Zr alloy surface.
文摘Objective To investigate the method of emergent relief of special renal colic and treatment of ureter diseases causing renal colic. Methods By analyzing 63 cases of special renal colic treated with ureteroscope and Holmium YAG laser. Results 61 cases of renal colic were relieved in a short period of time and the original ureter diseases causing renal colic were cured. Conclusion Special renal colic could be treated with ureteroscope and Holmium YAG laser in a quick and effective manner.
基金Supported in part by the Shenyang Young and Middle-aged Science and Technology Innovation Talent Support Program(No.RC210267).
文摘AIM:To assess the long-term efficacy and safety of yttrium-aluminum garnet(YAG)laser vitreolysis for vision degrading myodesopsia(VDM)caused by posterior vitreous detachment(PVD).METHODS:This retrospective study reviewed VDM patients of PVD type undergoing YAG laser vitreolysis.The baseline demographic information,the patterns of floaters,the number of floaters,and the subjective improvement of floater sympotoms(ranging from 0 to 100%)from medical records were collected.Significant improvement was defined as a relief of floater symptoms of≥50%at the final visit.The long-term efficacy and safety of YAG laser vitreolysis were analyzed.The risk factors linked to significant improvement of floater symptoms were defined using univariate and multivariate logistic regression analyses.RESULTS:The final analysis included 221 patients with VDM.The mean age of patients was 61.08±7.74y,and the mean length of follow-up was 21.38±5.61mo.Totally 57.01%of patients experienced a significant improvement in their floater symptoms after YAG laser therapy,and none of them developed delayed retinal abnormalities such as retinal tears or detachments.Age(OR=1.049,95%CI=1.007-1.092,P=0.021)was identified as a significant risk factor for significant improvement in VDM.CONCLUSION:YAG laser vitreolysis is an effective and secure treatment for PVD-type VDM,and patients of advanced age are more likely to get favorable outcomes.
基金The author thanks the Die and Mold Technology Promotion Foundation and the Amada Foundation for Metal Work Technology for their financial support.
文摘The effects of YAG laser welding conditions on mechanical properties andpress formability (bendability, stretch-formability and deep drawability) of high-strengthtransformation-induced plasticity-aided dual-phase (TDP) steel were investigated. Tensile tests andpress forming tests have been conducted for laser butt welded joints between two pieces of the samesteel. The tensile property and press formability were affected by the welding speed of 100 to1100mm/min and the energy of 6 to 9J/pulse. Excellent press formability was obtained with the energyof 6J/pulse and the welding speed of 300mm/min. It was concluded that the excellent weldability ofthe TDP steel can be ascribed to the weld joint formation.
基金Sponsored by National Science Fund!( 59881 0 0 2 )
文摘By using a Nd: YAG laser welding system devised for transmitting continuous, rectangular and pulsed waveforms, comprehensive and deep investigation is focused on the effects of several parameters of rectangular waveform and pulsed output wave superimposed on a rectangular waveform on the penetration depth of weld. Research results indicate that the average power, duty cycle, frequency and peak power of rectangular wave affect the weld penetration depth to different extent. Results of experiments and analysis also indicate that the pulse delay time, pulse width and the power ratio of pulse to rectangular waveform seriously influence the penetration when the pulsed wave is superimposed on a rectangular waveform.
基金supported by the Science Foundation of the Ministry of Science and Technology Malaysiathe Islamic Development Bank Jeddahsupport of the Universiti Teknologi Malaysia for this research work
文摘This study deals with Nd:YAG laser cutting nonmetallic materials, which is one of the most important and popular industrial applications of laser. The main theme is to evaluate the effects of Nd:YAG laser beam power besides work piece scanning speed. For approximate cutting depth, a theoretical study is conducted in terms of material property and cutting speed. Results show a nonlinear relation between the cutting depth and input energy. There is no significant effect of speed on cutting depth with the speed being larger than 30 mm/s. An extra energy is utilized in the deep cutting. It is inferred that as the laser power increases, cutting depth increases. The experimental outcomes are in good agreement with theoretical results. This analysis will provide a guideline for laser-based industry to select a suitable laser for cutting, scribing, trimming, engraving, and marking nonmetallic materials.
基金Supported by the Natural Science Foundation of Shandong Province under Grant Nos ZR2015FM018 and ZR2014FM028the National Natural Science Foundation of China under Grant No 61475086
文摘A high-power passively Q-switched Nd:YAG laser operating at lll2nm with Cr4+:yAO as a saturable absorber is demonstrated. Under 808 nm diode-direct pumping, the maximum average output power of 2.73 W is achieved at the pump power of 16.65 W, corresponding to an optical-to-optical conversion efficiency of 16.4%. At the same time, the pulse width, pulse repetition rate, single pulse energy and peak power are 27.2ns, 9 kHz, 303.3#3 and 11.2kW, respectively. As far as we know, the result gives the highest average output power at 1112nm generated by an 808 nm diode-end-pumped Nd:YAG laser.