期刊文献+
共找到5,219篇文章
< 1 2 250 >
每页显示 20 50 100
Detection of distribution of copper inside and outside of lysosomes in cultured hepatolenticular degeneration fibroblasts by electron probe X-ray microanalysis
1
作者 Wen Liu Jin-Yan Li +1 位作者 Ji Jin Ji Zuo the Department of Medical Genetics, Scholl of Medicine, Fudan University, Shanghai 200032, China Department of Biology, Zhenjiang Medical College, Zhenjiang 212000, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2003年第2期586-589,共4页
OBJECTIVE: To observe the distribution of copper in the subcellular structure for the understanding of primary pathogenesis of hepatolenticular degeneration (HLD). METHODS: Skin fibroblasts taken from HLD patients wer... OBJECTIVE: To observe the distribution of copper in the subcellular structure for the understanding of primary pathogenesis of hepatolenticular degeneration (HLD). METHODS: Skin fibroblasts taken from HLD patients were cultured as an in vitro model of HLD, and the control cells taken from healthy volunteers were clutured in the same way. The distribution of copper inside and outside of lysosomes in fibroblasts was detected by quantitative electron probe X-ray microanalysis. The relationship between the subcellular location of copper and the genotype of the patients, and relationship between the distribution of copper and the course of the disease were analyzed. RESULTS: The content of Cu^(2+) inside lysosomes of HLD cells (14.6±2.1 mmol/kg) and of heterozygote cells (11.6±0.6 mmol/kg) was higher than that of normal cells (4.5±1.2 mmol/kg) (P<0.01). The content of Cu^(2+) outside lysosomes of HLD cells (17.5±4.2 mmol/kg) and of heterozygote cells (12.0±0.9 mmol/kg) was higher than that of normal cells (4.7±1.2 mmol/kg) (P<0.01). The distribution of copper in the subcellular structure was correlated with disease courses of HLD patients. With the progression of the disease, more copper was deposited in lysosomes (r=0.85, P<0.01). The content of copper in the diffused cytoplasmic compartment in HLD cells was correlated with that of sulfur (r=0.86, P<0.05), but not in heterozygote and normal cells. CONCLUSIONS: In the early stage of HLD, copper is accumulated outside lysosome, which is paralleled with increase of metallothionein-like proteins (copper and sulfur-binding proteins). With the development of the disease, more copper is deposited inside lysosome than outside lysosome. We conclude that the up-regulation expression of copper and sulfur-binding proteins and copper accumulation in lysosomes may play an important role in lowering the ATP7B gene mutation-induced toxic effects of free copper on the cell. 展开更多
关键词 hepatolenticular degeneration FIBROBLAST LYSOSOME electron probe x-ray microanalysis copper-binding protein
暂未订购
Response estimation and evaluation of direct-conversion dual-layer perovskite X-ray detectors:a numerical study with a cascaded signal model
2
作者 Han Cui Yu-Hang Tan +7 位作者 Xin Zhang Hao-Di Wu Ting Su Jiong-Tao Zhu Hai-Rong Zheng Dong Liang Xiang-Ming Sun Yong-Shuai Ge 《Nuclear Science and Techniques》 2026年第2期156-168,共13页
This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation ... This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation transfer function(MTF),and detective quantum efficiency(DQE)of the DL-FPD are evaluated numerically using a linear cascade model.In addition,both the single-crystal(SC)and polycrystalline(PC)structures of MAPbI_(3)are investigated,along with various other key parameters such as the material thickness,electric field strength,X-ray beam spectrum,and electronic readout noise.The results demonstrate that SC perovskite consistently exhibits better performance than PC perovskite owing to fewer material defects.Increasing the layer thickness may decrease the MTF,but can also enhance the sensitivity and DQE.Moreover,appropriately increasing the external electric field within the material can improve the sensitivity,MTF,and DQE.Finally,reducing the electronic readout noise can significantly enhance the DQE for low-dose imaging.This study demonstrates the potential of high-quality dual-energy X-ray imaging using direct-conversion perovskite DL-FPDs. 展开更多
关键词 x-ray imaging Dual-layer flat-panel detector Perovskite x-ray detector
在线阅读 下载PDF
Impacts of X-ray energy and beam size on CD-SAXS measurement precision
3
作者 Xu-Yang Qin Bing Guo +7 位作者 Nan Pan Xin-Hao Gao Shu-Min Yang Chun-Xia Hong Ying Wang Xiu-Hong Li Chun-Ming Yang Feng-Gang Bian 《Nuclear Science and Techniques》 2026年第4期65-78,共14页
With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this ... With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this study,the effects of X-ray beam size and photon energy on the accuracy of critical dimension measurements were investigated.Critical dimensions measured using beams with different spot sizes showed different deviations from the expected values.Beam sizes that were either too large or too small did not improve confidence intervals.As the incident energy increased,the X-ray transmission rate increased,while the scattering cross section decreased,resulting in a gradual decrease in the signal-to-noise ratio of the diffraction peaks,which reduced the accuracy of the CD-SAXS measurements.An optimal accuracy was obtained at 12 keV with a smaller beam size.Using an effective trapezoid model,the results yielded an average pitch of 100.4±0.2 nm,width of 49.8±0.2 nm,height of 130.0±0.2 nm,and a sidewall angle below 1.1°±0.1°.These results provide crucial guidance for the future development of CD-SAXS laboratories and the construction of X-ray machines as well as robust support for research in related fields. 展开更多
关键词 Critical dimension small-angle x-ray scattering Nonlinear fitting Beam size x-ray energy Chip
在线阅读 下载PDF
Effect of measurement reduction on synthetic aperture x-ray ghost imaging
4
作者 Haipeng Zhang Jie Tang +4 位作者 Nixi Zhao Changzhe Zhao Jianwen Wu Zhongliang Li Tiqiao Xiao 《Chinese Physics B》 2026年第1期457-465,共9页
The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality.... The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality.Synthetic aperture x-ray ghost imaging(SAXGI)is invented to achieve megapixel XGI with limited measurements,which is expected to implement XGI simultaneously with large field of view and low radiation exposure.In this paper,we experimentally investigate the effect of measurements reduction on the spatial resolution and image quality of SAXGI with standard sample and biomedical specimen.The results with a resolution chart demonstrated that at 360 measurements,SAXGI successfully retrieved the sample image of 1960×1960 pixels with spatial resolution of 4μm.With measurement reduction,the spatial resolution deteriorates but the sparser structures are still discernable.Even with measurements reduced to 10,a spatial resolution of 10μm can still be achieved by SAXGI.A biomedical sample of a fish specimen is employed to evaluate the method and the fish image of 2000×1000 pixels with an SSIM of 0.962 is reconstructed by SAXGI with 770measurements,corresponding to an accumulative exposure reduction of more than 2 times.With the measurements reduced to 10 which corresponds to 1/160 of the accumulative radiation exposure for conventional radiology,bulky structure like the fish skeleton can still be definitely discerned and the SSIM for the reconstructed image still retained 0.9179.Results of this paper demonstrate that measurements reduction is practicable for the radiation exposure reduction of the sample,which implicates that SAXGI with limited measurements is an efficient solution for low dose radiology. 展开更多
关键词 x-ray ghost imaging synthetic aperture x-ray imaging low dose radiology compressed sensing algorithm
原文传递
Tracing equatorward and poleward boundaries of the magnetospheric cusp from a simulated X-ray image
5
作者 Xue Wang TianRan Sun +4 位作者 C.Philippe Escoubet Andy Read YiHong Guo Steve Sembay Chi Wang 《Earth and Planetary Physics》 2026年第1期144-155,共12页
A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-d... A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-dimensional cusp boundary from a two-dimensional X-ray image because the detected X-ray signals will be integrated along the line of sight.In this work,a global magnetohydrodynamic code was used to simulate the X-ray images and photon count images,assuming an interplanetary magnetic field with a pure Bz component.The assumption of an elliptic cusp boundary at a given altitude was used to trace the equatorward and poleward boundaries of the cusp from a simulated X-ray image.The average discrepancy was less than 0.1 RE.To reduce the influence of instrument effects and cosmic X-ray backgrounds,image denoising was considered before applying the method above to SXI photon count images.The cusp boundaries were reasonably reconstructed from the noisy X-ray image. 展开更多
关键词 SMILE mission x-ray image cusp boundary
在线阅读 下载PDF
Three-dimensional characterization of intermetallic compound formation in magnesium alloys with micro X-ray computed tomography
6
作者 SUN Wei HU Xiao-juan +5 位作者 DENG Yang-chao YANG Yang YAO Hu ZHANG Yong-hong ZHANG Rui-feng ZENG Guang 《Journal of Central South University》 2026年第1期160-174,共15页
This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both commo... This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both common industrial Mg-Al-Zn alloys and a novel rare earth-containing Mg-Ni-Gd-Y alloy,we aim to characterize the nucleation,growth,and distribution of Al-Mn and eutectic intermetallics across various stages of solidification.The non destructive imaging technique employed in this research provides high-resolution,three-dimensional insights into the microstructural development,allowing for a detailed examination of the morphology,spatial arrangement,and interconnectivity of intermetallic phases.This approach overcomes limitations of traditional two-dimensional metallographic methods,offering a more comprehensive understanding of the complex three-dimensional structures formed during solidification. 展开更多
关键词 magnesium alloy x-ray computed tomography SOLIDIFICATION INTERMETALLICS DEFECTS
在线阅读 下载PDF
Comparative evaluation of single-mask and single-shot X-ray phase-contrast and dual-energy computed tomography analyses on soft-tissue phantom
7
作者 Chang Li Xiao-Xuan Ren +6 位作者 Liang-Liang Lv Shu-Yi Sun Jian Zhang Yin-Qi Lei Xiao-Dong Pan Cui Zhang Gong-Ping Li 《Nuclear Science and Techniques》 2026年第5期241-251,共11页
In clinical diagnosis,conventional X-ray absorption-contrast computed tomography(XACT)technology cannot effectively differentiate diseased tissues from the healthy ones.X-ray phase-contrast CT(XPCT)and dual-energy CT(... In clinical diagnosis,conventional X-ray absorption-contrast computed tomography(XACT)technology cannot effectively differentiate diseased tissues from the healthy ones.X-ray phase-contrast CT(XPCT)and dual-energy CT(DECT),emerging X-ray imaging technologies with superior diagnostic capabilities,address this issue through different principles.While both XPCT and DECT have advantages and disadvantages in medical applications,their systematic comparison is lacking.Using GEANT4 and MATLAB,in this study,we established an X-ray phase-contrast imaging(XPCI)model based on single-mask and single-shot edge illumination for fast XPCT imaging,comparing it with DECT on soft-tissue phantom.XACT served as a reference for comparison.The study introduces an evaluation system using statistical measures including absolute error,mean absolute error,structure similarity index measure,peak signal-to-noise ratio,and contrast-to-noise ratio.Results show XPCT images are superior to DECT.The XPCI model can be improved on existing medical CT for widespread medical application. 展开更多
关键词 Comparative evaluation x-ray phase-contrast CT Edge illumination Dual-energy CT GEANT4
在线阅读 下载PDF
Enhancing Heat Transfer in X-ray Tube by van der Waals Heterostructures-based Thermionic Emission
8
作者 LI Qian-qian HUANG Sun-chao +8 位作者 CHEN Su-guo WANG Yue SHI Xi-hang ZHANG Xiao-qiu-yan HU Min ZHANG Ping WANG Shao-meng ZHANG Chao GONG Yu-bin 《真空电子技术》 2026年第1期21-27,共7页
Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics... Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics,and free electron radiation devices.Particularly,they are promising platforms for studying thermionic emission.It is illustrated that using vdW heterostructure-based thermionic emission can enhance heat transfer in vacuum devices.As a proof of concept,the approach is demonstrated to offer a promising solution for the long-standing overheating issue in X-ray tubes.Specifically,it is shown that the saturated target temperature of a 2000 W X-ray tube can be reduced from around 1200℃ to 490℃.Additionally,it is also demonstrated that by reducing the height of the Schottky barrier formed in the vdW heterostructures,the thermionic cooling performance can be enhanced.The findings pave the way for the development of high-power X-ray tubes. 展开更多
关键词 x-ray tube Heat transfer Thermionic emission Thermionic cooling Van der Waals Heterostructures
在线阅读 下载PDF
Noncovalent Interaction-Mediated Space Charge Transition Facilitated Isolated Copper(I)-Iodide Clusters:Enabling High-Resolution X-Ray Imaging and Dynamic Encryption
9
作者 Zhao-Xing Gao Wen-Fei Wang +3 位作者 Mian-He Xu Shuai-Hua Wang Fa-Kun Zheng Guo-Cong Guo 《Aggregate》 2026年第2期241-249,共9页
The exploration of solvent-driven reversible structural transformation in clusters is crucial for advanced stimulus-responsive optical applications and understanding of structure-property relationships.Herein,we repor... The exploration of solvent-driven reversible structural transformation in clusters is crucial for advanced stimulus-responsive optical applications and understanding of structure-property relationships.Herein,we report a solvent-driven reversible trans-formation between two copper(I)clusters:[Cu(totp)(CH_(3)CN)_(3)][Cu_(2)I_(3)(totp)(DPPPy)]·CH_(3)CN 1 and Cu_(4)I_(4)(DPPPy)_(2)·0.5CH_(2)Cl_(2)2(totp=tri-o-tolylphosphine,DPPPy=2-[diphenylphosphino]pyridine).X-ray radioluminescence and encryption applications were studied based on structure-dependent photophysical properties difference.The noncovalent interaction-mediated space charge transition between isolated ion units of 1 enables more efficient thermally activated delayed fluorescence by reverse intersystem crossing,accounting for structure-dependent luminescence.Notably,compared to 2,1 exhibits a higher scintillation light yield of 14832 photons MeV^(-1),exceeding that of the commercial scintillator Bi_(4)Ge_(3)O_(12)(8000 photons MeV^(-1)),and a low X-ray detection limit of 22.49 nGy s^(-1),far below the typical diagnostic dose(5.5μGy s^(-1)).Furthermore,scintillating film fabricated by 1 achieves X-ray imaging with a high spatial resolution of 16 lp/mm.The reversible structural interconversion enables solvent-responsive luminescent switches,and thus,the dynamic encryption system capable of multistage decryption was developed.This work not only offers new insight into solvent-regulated clusters transformations but also provides a promising strategy for developing high-performance copper(I)clusters-based scintillators and stimulus-responsive optical devices. 展开更多
关键词 copper(I)-iodide clusters information encryption solvent-driven structural transformation x-ray imaging
在线阅读 下载PDF
Lattice Anchoring Stabilizesα-FAPbI_(3) Perovskite for High-Performance X-Ray Detectors
10
作者 Yu-Hua Huang Su-Yan Zou +5 位作者 Cong-Yi Sheng Yu-Chuang Fang Xu-Dong Wang Wei Wei Wen-Guang Li Dai-Bin Kuang 《Nano-Micro Letters》 2026年第1期337-354,共18页
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl... Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses. 展开更多
关键词 α-FAPbI_(3)perovskite Conjugated organic cation Lattice anchoring Phase stability x-ray detectors
在线阅读 下载PDF
Ultralow dark current soft X-ray detectors based on lead-free double perovskite Cs_(2)AgBiBr_(6)
11
作者 Long Cheng Lijuan Huang +15 位作者 Mulin Sun Ying Meng Yuan Li Tianyu Liu Pengju Tan Mingzhu Hu Huaqing Yang Xiaolan Ma Shunjie Yu Xiaohu Hou Yong Guan Junfa Zhu Xiaosong Liu Yu Li Shibing Long Qin Hu 《Journal of Semiconductors》 2026年第1期109-116,共8页
Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stabi... Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors. 展开更多
关键词 soft x-ray detector lead-free double perovskite Cs_(2)AgBiBr_(6) ALLOYING IMAGING
在线阅读 下载PDF
Effect of Beam Current and Diameter on Electron Probe Microanalysis of Carbonate Minerals 被引量:7
12
作者 Xing Zhang Shuiyuan Yang +3 位作者 He Zhao Shaoyong Jiang Ruoxi Zhang Jing Xie 《Journal of Earth Science》 SCIE CAS CSCD 2019年第4期834-842,共9页
The effect of operating conditions on the time-dependent X-ray intensity variation is of great importance for the optimal EPMA conditions for accurate determinations of various elements in carbonate minerals. Beam dia... The effect of operating conditions on the time-dependent X-ray intensity variation is of great importance for the optimal EPMA conditions for accurate determinations of various elements in carbonate minerals. Beam diameters of 0, 1, 2, 5, 10, 15, and 20 μm, and beam currents of 3, 5, 10, 20,and 50 nA were tested. Ca, Mg, Zn, and Sr were found to be more sensitive to electron beam irradiation as compared to other elements, and small currents and large beam diameters minimized the timedependent X-ray intensity variations. We determined the optimal EPMA operating conditions for elements in carbonate: 10 μm and 5 nA for calcite;10 μm and 10 nA for dolomite;5 μm and 10 nA or 10 μm and 20 nA for strontianite;and 20 nA and 5 μm for other carbonate. Elements sensitive to electron beam irradiation should be determined first. In addition, silicate minerals are preferred as standards rather than carbonate minerals. 展开更多
关键词 CARBONATE minerals:electron probe microanalysis characteristic x-ray TIME-DEPENDENT intensity BEAM current BEAM DIAMETER
原文传递
Electron probe microanalysis for revealing occurrence mode of scandium in Bayer red mud 被引量:7
13
作者 Na Zhang Hong-Xu Li +1 位作者 Hui-Jing Cheng Xiao-Ming Liu 《Rare Metals》 SCIE EI CAS CSCD 2017年第4期295-303,共9页
Red mud is a bauxite residue generated during the process of alumina production. In this research, the occur- rence mode of scandium in the Bayer red mud was investi- gated mainly by electron probe microanalysis (EPM... Red mud is a bauxite residue generated during the process of alumina production. In this research, the occur- rence mode of scandium in the Bayer red mud was investi- gated mainly by electron probe microanalysis (EPMA). The Bayer red mud used in this work is composed of 21.47 wt% hematite, 12.13 wt% goethite, 8.86 wt% gibbsite, 5.02 wt% perovskite, 9.70 wt% quartz, 3.23 wt% anhydrite, 29.92 wt% Na_2Al_2Si_5O_14 and 9.67 wt% Al_3Fe_5O_12. Besides, the scandium content in the Bayer red mud is 84.32 × 10-6, indicating that this Bayer red mud is an important scandium resource deserving exploitation. The EPMA results show that the scandium within the Bayer red mud is mainly occurring in the iron minerals of hematite and goethite with the isomorphism form, but its distribution is not homogeneous in these iron minerals with the Sc_2O_3 content between 330 × 10-6 and 2040 × 10-6. This study provides a theoretical base for the further experimental work on the scandium extraction from this Bayer red mud. 展开更多
关键词 SCANDIUM Occurrence mode Bayer red mud Electron probe microanalysis
原文传递
Microanalysis of Multi-Element in Juncus effusus L. by LIBS Technique 被引量:3
14
作者 刘晓娜 黄建梅 +5 位作者 吴志生 张乔 史新元 赵娜 贾帅芸 乔延江 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期904-908,共5页
Laser-induced breakdown spectroscopy (LIBS) was used to decipher the unique multi-elemental characteristics of Juncus effusus L. The spectral fingerprints of Juncus effusus L. were established based on elemental mic... Laser-induced breakdown spectroscopy (LIBS) was used to decipher the unique multi-elemental characteristics of Juncus effusus L. The spectral fingerprints of Juncus effusus L. were established based on elemental microanalysis via LIBS. Microanalysis and multimode sampling methodologies were designed in this study. The relative standard deviation (RSD) approach was performed to optimize the multi-shot measurements. Taking advantage of the capability with no or minimal sample pre-treatment of LIBS, a thermodynamic chart of four elements (Mg, Ca, Ba, and Na) was created from twelve collection regions. The diagram of elemental distribution on a micro-scale was generated to explore the nature of Juncus effusus L. by LIBS. The results demon- strated that LIBS is a promising technique for rapid elemental microanalysis of heterogeneous samples. 展开更多
关键词 LIBS Juncus effusus L. RSD approach thermodynamic chart elemental microanalysis MICRO-SCALE
在线阅读 下载PDF
Microanalysis and preliminary pharmacokinetic studies of a sulfated polysaccharide from Laminariajaponica 被引量:4
15
作者 张文静 孙德林 +3 位作者 赵峡 金维华 王晶 张全斌 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2016年第1期177-185,共9页
A rapid, sensitive and reproducible high performance liquid chromatography (HPLC) method with post-column fluorescence derivatization has been developed to determine the amount of low-molecular- weight sulfated poly... A rapid, sensitive and reproducible high performance liquid chromatography (HPLC) method with post-column fluorescence derivatization has been developed to determine the amount of low-molecular- weight sulfated polysaccharide (GFS) in vivo. The metabolism of GFS has been shown to fit a two component model following its administration by intravenous injection, and its pharmacokinetic parameters were determined to be as follows: half-time of distribution phase (t1/2α)=11.2±2.93 min, half-time of elimination phase (tl/2α)=98.20±25.78 min, maximum concentration (Cmax)=110.53 gg/mL and peak time (Tmax)=5 min. The pharmacokinetic behavior of GFS was also investigated following intragastric administration. However, the concentration of GFS found in serum was too low for detection, and GFS could only be detected for up to 2 h after intragastric administration (200 mg/kg body weight). Thus, the bioavailability of GFS was low following intragastric administration because of the metabolism of GFS. In conclusion, HPLC with post-column derivatization could be used for quantitative microanalysis and pharmacokinetic studies to determine the presence of polysaccharides in the serum following intravenous injection. 展开更多
关键词 sulfated polysaccharide HPLC post-column derivatization microanalysis PHARMACOKINETICS
原文传递
Microanalysis on the Hydrogen Ion Irradiated 50 wt pct TiC-C Films 被引量:1
16
作者 Hui JIANG Yaoguang LIU Ningkang HUANG 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2007年第1期127-130,共4页
The 50 wt pct TiC-C films were prepared on stainless steel substrates by using a technique of ion beam mixing. These films were irradiated by hydrogen ion beam with a dose of 1×10^18 ions/cm^2 and an energy of 5 ... The 50 wt pct TiC-C films were prepared on stainless steel substrates by using a technique of ion beam mixing. These films were irradiated by hydrogen ion beam with a dose of 1×10^18 ions/cm^2 and an energy of 5 keV. Microanalysis of X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectroscopy (SIMS) were used to analyze the films before and after hydrogen ion irradiation and to study the mechanism of hydrogen resistance. 展开更多
关键词 Titanium carbide Hydrogen ion irradiation microanalysis
在线阅读 下载PDF
Ore Microscopy and Microanalysis of the Nickeliferous Iron Ores from Komnina Vermion Area (N.W. Greece) 被引量:3
17
作者 Georgios Alevizos Eftychia Repouskou 《Geomaterials》 2011年第2期46-50,共5页
Nickel laterites are considerable sources of nickel. To be successfully exploited it is important to know the mineralogical and microstructural characteristics of the ore. Besides, the identification of the mineralogi... Nickel laterites are considerable sources of nickel. To be successfully exploited it is important to know the mineralogical and microstructural characteristics of the ore. Besides, the identification of the mineralogical components as well as the fabric description, can lead to the interpretation of the mechanism of deposit genesis. The aim of the present study is the microscopic and microanalytical investigation of the Fe-Ni ores from Komnina Vermion area (N.W. Greece). The mineralogical composition of the ore is mainly hematite, quartz, chromite and chlorite, while in minor quantities goethite, nickeliferous chlorite, serpentine, talc and calcite are also present. The ore structure is allotriomorphic inequigranular and the texture is oolitic-pisolitic. According to microscopic examination the deposit can be registered as a secondary pseudo-autochthonous. 展开更多
关键词 ORE MICROSCOPY microanalysis Fe-Ni-Ores Komnina-Vermion (Greece).
暂未订购
Seasonal variation and chemical composition of particulate matter: A study by XPS, ICP-AES and sequential microanalysis using Raman with SEM/EDS 被引量:5
18
作者 Lucy T.González Francisco E.Longoria-Rodríguez +5 位作者 Margarita Sánchez-Domínguez Cesar Leyva-Porras Karim Acuna-Askar Boris I.Kharissov Alejandro Arizpe-Zapata Juan M.Alfaro-Barbosa 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第12期32-49,共18页
During the winter period(January–March 2016), the total suspended particles(TSP) and particulate matter smaller than 2.5 μm(PM2.5) were characterized by the application of various analytical techniques in four... During the winter period(January–March 2016), the total suspended particles(TSP) and particulate matter smaller than 2.5 μm(PM2.5) were characterized by the application of various analytical techniques in four zones of the Metropolitan Area of Monterrey in Mexico. To evaluate the seasonal variation of some elements in the particulate matter, the results of this study were compared with those obtained during the summer season(July–September 2015). The speciation of the C_(1s) signal by X-ray photoelectron spectroscopy revealed the contribution of aromatic and aliphatic hydrocarbons as the main components in both seasons. Conversely, carboxylic groups associated with biogenic emissions were detected only in winter. The percentages of SO_4^(2-) ions were lower in winter, possibly caused by the decrease in the solar radiation, and relative humidity recorded. The results of the ICP analysis revealed that Fe, Zn and Cu were the most abundant metals in both TSP and PM2.5 in the two seasons. There were significant seasonal variations for concentrations of As, Ni and Zn in the urban area and for Fe, As, Cd, Ni and Zn in the industrial zone. This was attributed to the greater burning of fuels as well as to an increase in vehicular traffic, the effect of thermal inversion and changes in some meteorological parameters. The results of the sequential microanalysis by Raman spectroscopy and SEM/EDS allowed observation of deposits of carbonaceous material on the particles and to perform the speciation of particles rich in Fe and Pb, which helped infer their possible emission sources. 展开更多
关键词 Seasonal variation Total suspended particles PM2.5 x-ray photoelectron spectroscopy Micro-Raman spectroscopy
原文传递
Electron probe microanalysis оf experimentally stimulated osteoarthrosis in dogs
19
作者 Tatyana Stupina Michael Shchudlo Michael Stepanov 《World Journal of Orthopedics》 2017年第9期681-687,共7页
AIM To develop methods of articular cartilage preparation for X-ray-electron probe microanalysis and to study its elements content in experimental osteoarthrosis.METHODS Twenty dogs aged 2-8 years were divided in rese... AIM To develop methods of articular cartilage preparation for X-ray-electron probe microanalysis and to study its elements content in experimental osteoarthrosis.METHODS Twenty dogs aged 2-8 years were divided in research(aged 2 years, induction of osteoarthrosis-IOA) and intact group. Intact group included three subgroups(aged 2, 5 and 8 years). Samples of cartilage after araldite saturation and pouring were partially cut into semithin sections stained with methylene blue and with methylene blue-basic fuchsin. Their smooth surfaces were investigated by X-ray-electron probe microanalysis. Spatial distribution of sulfur, calcium and phosphorus and their concentrations(weight %) were investigated.RESULTS X-ray electron probe microanalysis revealed non-uniformsulfur distribution in cartilage of intact animals: Its content increases from superficial zone to deep one, this regularity was preserved in animals with IOA. Differences of IOA with spontaneous chondropathy were revealed. Spontaneous aging was characterized by calcium and phosphorus storage in deep and calcified zones and compensatory increase of sulfated glycosaminoglycans in intermediate and deep cartilage zones as evidenced by the metachromatic reaction and microanalysis data. Unlike spontaneous chondropathy connected with aging in experimentally stimulated osteoarthrosis more intensive storage of calcium but minor phosphorus in intermediate zone were marked. In IOA the calcified cartilage thinning and osteoclastic resorption are apparent with few changes of elements composition; the only difference from control is minority phosphorus content.CONCLUSION The obtained results demonstrate specific tricks of X-ray electron probe microanalysis and its possibility in the research of mechanisms of articular cartilage alterations in osteoarthrosis. 展开更多
关键词 OSTEOARTHROSIS ARTICULAR CARTILAGE DOG x-ray electron probe microanalysis
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部