Small angle x-ray scattering(SAXS)is an advanced technique for characterizing the particle size distribution(PSD)of nanoparticles.However,the ill-posed nature of inverse problems in SAXS data analysis often reduces th...Small angle x-ray scattering(SAXS)is an advanced technique for characterizing the particle size distribution(PSD)of nanoparticles.However,the ill-posed nature of inverse problems in SAXS data analysis often reduces the accuracy of conventional methods.This article proposes a user-friendly software for PSD analysis,GranuSAS,which employs an algorithm that integrates truncated singular value decomposition(TSVD)with the Chahine method.This approach employs TSVD for data preprocessing,generating a set of initial solutions with noise suppression.A high-quality initial solution is subsequently selected via the L-curve method.This selected candidate solution is then iteratively refined by the Chahine algorithm,enforcing constraints such as non-negativity and improving physical interpretability.Most importantly,GranuSAS employs a parallel architecture that simultaneously yields inversion results from multiple shape models and,by evaluating the accuracy of each model's reconstructed scattering curve,offers a suggestion for model selection in material systems.To systematically validate the accuracy and efficiency of the software,verification was performed using both simulated and experimental datasets.The results demonstrate that the proposed software delivers both satisfactory accuracy and reliable computational efficiency.It provides an easy-to-use and reliable tool for researchers in materials science,helping them fully exploit the potential of SAXS in nanoparticle characterization.展开更多
β-ray-induced X-ray spectroscopy(BIXS)is a promising technique for tritium analysis that offers several unique advantages,including substantial detection depth,nondestructive testing capabilities,and ease of operatio...β-ray-induced X-ray spectroscopy(BIXS)is a promising technique for tritium analysis that offers several unique advantages,including substantial detection depth,nondestructive testing capabilities,and ease of operation.For thin solid tritium-containing samples with substrates,the currently used BIXS analysis method can measure the tritium depth profile and content when the sample thickness is known.In this study,a backpropagation(BP)neural network algorithm was used to predict the tritium content and thickness of a thin solid tritium-containing sample with substrates and a uniformly distributed tritium profile.A semi-analytical method was used to generate datasets for training and testing the BP neural network.A dataset ofβ-decay X-ray spectra from 420 tritium-containing zirconium models with different known thicknesses and tritium-tozirconium ratios was used as the input data.The corresponding zirconium thicknesses and tritium-to-zirconium ratios served as the output for training and testing the BP neural network.The mean relative errors(MREs)of the zirconium thickness in the training and test datasets were 0.56%and 0.42%,respectively,whereas the MREs of the tritium-to-zirconium ratio were 0.59%and 0.38%,respectively.Furthermore,the trained BP neural network demonstrates excellent predictive capability across various levels of statistical uncertainty.For the experimentalβ-decay X-ray spectra of two tritium-containing samples,the predicted zirconium thicknesses and tritium-to-zirconium ratios showed good agreement with the results obtained through the elastic backscattering spectrometry(EBS).展开更多
Synchrotron polychromatic X-ray microdiffraction(micro-XRD) was applied to study in situ deformation twinning of commercially AZ31(Mg-3Al-1Zn) strip subjected to uniaxial tension.The morphology and growth of twins...Synchrotron polychromatic X-ray microdiffraction(micro-XRD) was applied to study in situ deformation twinning of commercially AZ31(Mg-3Al-1Zn) strip subjected to uniaxial tension.The morphology and growth of twins were analyzed in situ under the load level from 64 to 73 MPa.The X-ray microdiffraction data,collected on beamline 12.3.2 at the Advanced Light Source,were then used to map an area of 396μm x 200μm within the region of interest.The experimental set-up and X-ray diffraction microscopy with a depth resolution allow the position and orientation of each illuminated grain to be determined at the submicron size.A list of parent grains sorted by crystallographic orientation were selected to examine their twinning behavior.The results depict twin variant selection,local misorientation fluctuation and mosaic spread for multi-twins within the same parent grain.As load increases,the amplitude of misorientation fluctuation along twin trace keeps increasing.This is attributable to the accumulation of geometrically necessary dislocations.展开更多
A method was developed for content determination of Na, Mg, A1, Si, P,S, C1, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Nb, Zr, Y, Sr, Rb, Ba, La and Ce etc. covering 26 major, minor, and trace elements in marine sedim...A method was developed for content determination of Na, Mg, A1, Si, P,S, C1, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Nb, Zr, Y, Sr, Rb, Ba, La and Ce etc. covering 26 major, minor, and trace elements in marine sediment samples using fused glass disc by X-ray Fluorescence spectrometry. Calibration was made using marine sediment certified reference materials and the synthetic standard samples prepared by mixing several marine sediments with stream sediment and carbonate standard samples in different proportions. The matrix effect was corrected using theoretical alpha coefficients, experience coefficients and the scattered radiation as the internal standard (for the trace elements). The accuracy of the method was evaluated by analysis of certified reference materials GBW07314, GBW07334 and GSMS6. The results are in good agreement with the certified values of the standards with RSD less than 2.60%, except for Y, Cr, Ga, Ce, La, Nb, Rb, and V with RSD less than 9.0% (n=12).展开更多
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance.To quantify the mineral dissemination and pore space distribution of an ore particle,a...Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance.To quantify the mineral dissemination and pore space distribution of an ore particle,a cylindrical copper oxide ore sample(I center dot 4.6 mm x 5.6 mm)was scanned using high-resolution X-ray computed tomography(HRXCT),a nondestructive imaging technology,at a spatial resolution of 4.85 mu m.Combined with three-dimensional(3D)image analysis techniques,the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated.In addition,the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques.Furthermore,the pore phase features,including the pore size distribution,pore surface area,pore fractal dimension,pore centerline,and the pore connectivity,were investigated quantitatively.The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated,with a large surface area and low connectivity.This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data.展开更多
The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectr...The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.展开更多
A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample ...A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory.展开更多
To examine accuracy of body composition predicted by the Multi-Frequency Bioelectric Impedance Analysis (MF-BIA) compared with the Dual-energy X-ray Absorptiometry (DXA) in adults with obese. We measured body comp...To examine accuracy of body composition predicted by the Multi-Frequency Bioelectric Impedance Analysis (MF-BIA) compared with the Dual-energy X-ray Absorptiometry (DXA) in adults with obese. We measured body composition of 749 adults with obese both by the MF-BIA and DXA. The Lin's concordance correlation and the Bland-Altman plots were used to examine the consistency. The concordance correlation coefficient of %BF between the MF-BIA and DXA in men and women was 0.560, and 0.669, respectively. Compared with the DXA, the MF-BIA significantly underestimated %BF by 4.33% in men (P 〈 0.001), however overestimated %BF by 0.50% in women (P 〈 0.001). After corrected by the correction equations established in this study, the differences were significantly decreased. Therefore, the MF-BIA (TANITA MC-180) may need to be corrected in estimating body composition for adults with obese.展开更多
Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in therm...Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in thermal power plants,the measurement repeatability of LIBS needs to be further improved due to the difficulty in controlling the stability of the generated plasmas at present.In this paper,we propose a novel x-ray fluorescence(XRF) assisted LIBS method for high repeatability analysis of coal quality,which not only inherits the ability of LIBS to directly analyze organic elements such as C and H in coal,but also uses XRF to make up for the lack of stability of LIBS in determining other inorganic ash-forming elements.With the combination of elemental lines in LIBS and XRF spectra,the principal component analysis and the partial least squares are used to establish the prediction model and perform multi-elemental and proximate analysis of coal.Quantitative analysis results show that the relative standard deviation(RSD) of C is 0.15%,the RSDs of other elements are less than 4%,and the standard deviations of calorific value,ash content,sulfur content and volatile matter are 0.11 MJ kg,0.17%,0.79% and 0.41%respectively,indicating that the method has good repeatability in determination of coal quality.This work is helpful to accelerate the development of LIBS in the field of rapid measurement of coal entering the power plant and on-line monitoring of coal entering the furnace.展开更多
Stoichiometric hydroxyapatite(HA)nanoparticles were synthesized by a wet chemical method.Calcium nitrate tetra hydrate used as calcium source and dibasic ammonium phosphate used as phosphorous source.Calcium nitrate t...Stoichiometric hydroxyapatite(HA)nanoparticles were synthesized by a wet chemical method.Calcium nitrate tetra hydrate used as calcium source and dibasic ammonium phosphate used as phosphorous source.Calcium nitrate tetra hydrate and dibasic ammonium phosphate solutions were prepared by dissolving the salts in distilled water.Stoichiometric hydroxyapatite nanoparticles used by artificial bone powders and synthesized by a wet chemical method were analyzed using EDXRF method.The concentrations of K,Ca,Ti,V,Cr,Fe,Ni,Cu,Sr and Pb for artificial bone powders have been determined.Besides,Calcium contents were evaluated according to the agitation time and temperature in the production process.展开更多
Matrix swelling effect will cause the change of microstructure of coal reservoir and its permeability,which is the key factor affecting the engineering effect of CO_(2)-ECBM technology.The Sihe and Yuwu collieries are...Matrix swelling effect will cause the change of microstructure of coal reservoir and its permeability,which is the key factor affecting the engineering effect of CO_(2)-ECBM technology.The Sihe and Yuwu collieries are taken as research objects.Firstly,visualization reconstruction of coal reservoir is realized.Secondly,the evolution of the pore/fracture structures under different swelling contents is discussed.Then,the influence of matrix phase with different swelling contents on permeability is discussed.Finally,the mechanism of swelling effect during the CO_(2)-ECBM process is further discussed.The results show that the intra-matrix pores and matrix-edge fractures are the focus of this study,and the contacting area between matrix and pore/fracture is the core area of matrix swelling.The number of matrix particles decreases with the increase of size,and the distribution of which is isolated with small size and interconnected with large size.The swelling effect of matrix particles with larger size has a great influence on the pore/fracture structures.The number of connected pores/fractures is limited and only interconnected in a certain direction.With the increase of matrix swelling content,the number,porosity,width,fractal dimension,surface area and volume of pores/fractures decrease,and their negative contribution to absolute permeability increases from 0.368% to 0.633% and 0.868%-1.404%,respectively.With the increase of swelling content,the number of intra-matrix pores gradually decreases and the pore radius becomes shorter during the CO_(2)-ECBM process.The matrix continuously expands to the connected fractures,and the width of connected fractures gradually shorten.Under the influence of matrix swelling,the bending degree of fluid flow increases gradually,so the resistance of fluid migration increases and the permeability gradually decreases.This study shows that the matrix swelling effect is the key factor affecting CBM recovery,and the application of this effect in CO_(2)-ECBM process can be discussed.展开更多
X-ray fluorescence (XRF) analysis utilizes particle size which is resulted from milling of a material. The milling ensures uniform and fine grained powder. The finer and more uniform the particle size is, the better t...X-ray fluorescence (XRF) analysis utilizes particle size which is resulted from milling of a material. The milling ensures uniform and fine grained powder. The finer and more uniform the particle size is, the better the result and easier it is for material quality control. To ensure uniformity in particle size and finer powder, a comparative analysis was conducted with different grinding aids and pressed pellet method was used in obtaining analysis results. Pressed pellets of cement raw meal sample milled with different grinding aids (graphite, aspirin and lithium borate) were subjected to XRF. Graphite produced better particle size uniformity with a corresponding standard deviation that made quality control of raw meal easier and better than aspirin and lithium borate.展开更多
The density,nature of the dislocations and distribution of the domain sizes in cold-deformed Pb-Ca-Sn solid solution were determined by X-ray diffraction profile analysis.The dislocation densities are of the order of ...The density,nature of the dislocations and distribution of the domain sizes in cold-deformed Pb-Ca-Sn solid solution were determined by X-ray diffraction profile analysis.The dislocation densities are of the order of 1010 cm-2.The strain broadening of diffraction profiles was accounted for by dislocation contrast factor.The coherent domain size was determined by the recently developed PM2K software package.Assuming that the domain size distribution is log-normal,the distribution function(median μ and variance σ) was calculated from the size parameters determined from X-ray diffraction profile analysis.展开更多
BACKGROUND Conventional plain X-ray images of rats,the most common animals used as degeneration models,exhibit unclear vertebral structure and blurry intervertebral disc spaces due to their small size,slender vertebra...BACKGROUND Conventional plain X-ray images of rats,the most common animals used as degeneration models,exhibit unclear vertebral structure and blurry intervertebral disc spaces due to their small size,slender vertebral bodies.AIM To apply molybdenum target X-ray photography in the evaluation of caudal intervertebral disc(IVD)degeneration in rat models.METHODS Two types of rat caudal IVD degeneration models(needle-punctured model and endplate-destructed model)were established,and their effectiveness was verified using nuclear magnetic resonance imaging.Molybdenum target inspection and routine plain X-ray were then performed on these models.Additionally,four observers were assigned to measure the intervertebral height of degenerated segments on molybdenum target plain X-ray images and routine plain X-ray images,respectively.The degeneration was evaluated and statistical analysis was subsequently conducted.RESULTS Nine rats in the needle-punctured model and 10 rats in the endplate-destructed model were effective.Compared with routine plain X-ray images,molybdenum target plain X-ray images showed higher clarity,stronger contrast,as well as clearer and more accurate structural development.The McNemar test confirmed that the difference was statistically significant(P=0.031).In the two models,the reliability of the intervertebral height measured by the four observers on routine plain X-ray images was poor(ICC<0.4),while the data obtained from the molybdenum target plain X-ray images were more reliable.CONCLUSIONMolybdenum target inspection can obtain clearer images and display fine calcification in the imaging evaluation of caudal IVD degeneration in rats,thus ensuring a more accurate evaluation of degeneration.展开更多
Results of researches on plastic deformation of steels were obtained by acoustic emission and X-ray methods.The new numerical-analytical method of the thin structure parameter determination on one diffraction line was...Results of researches on plastic deformation of steels were obtained by acoustic emission and X-ray methods.The new numerical-analytical method of the thin structure parameter determination on one diffraction line was offered.It is supposed that with a growth of the deformation the cubic lattice will be transformed in the orthorhombic lattice.It is shown that changes of a condition of crystal structure of austenitic steel occur in four stages and of carbonaceous steel occur in six stages.Existence of two types of acoustic emission sources in carbonaceous steel and one type of acoustic emission source in austenitic steel was proposed.展开更多
A new method for quantitative X-ray diffraction phase analysis of a powder misture has been developed according to Popovic's doping method. The weight fraction of amorphous material in the analysed sample is obtai...A new method for quantitative X-ray diffraction phase analysis of a powder misture has been developed according to Popovic's doping method. The weight fraction of amorphous material in the analysed sample is obtained. For a multicomponent system in which (n-2) pure phases are added into an n-phase compnent sample and theweight fractions of all n phases can be determined by the method. The test results of confirmation agree well with the theory.展开更多
BACKGROUND: Alpha-actinin ( a -actinin) plays a key role in neuronal growth cone migration during directional differentiation from neural stem cells (NSCs) to neurons. OBJECTIVE: To detect in situ microdistribut...BACKGROUND: Alpha-actinin ( a -actinin) plays a key role in neuronal growth cone migration during directional differentiation from neural stem cells (NSCs) to neurons. OBJECTIVE: To detect in situ microdistribution and quantitative expression of a -actinin during directional differentiation of NSCs to neurons in the temporal lobe cerebral cortex of neonatal rats. DESIGN, TIME AND SETTING: Between January 2006 and December 2008, culture and directional differentiation of NSCs were performed at Department of Histology and Embryology, Preclinical Medical College, China Medical University. Immune electron microscopy was performed at Department of Histology and Embryology and Department of Electron Micrology, Preclinical Medical College, China Medical University. Spectrum analysis was performed at Laboratory of Electron Microscopy, Mental Research Institute, Chinese Academy of Sciences. MATERIALS: Basic fibroblast growth factor, epidermal growth factor, brain-derived nerve growth factor, type-1 insulin like growth factor, and a -actinin antibody were provided by Gibco BRL, USA; rabbit-anti-rat nestin monoclonal antibody, rabbit-anti-rat neuron specific enolase polyclonal antibody, and EDAX-9100 energy dispersive X-ray analysis were provided by PHILIPS Company, Netherlands. METHODS: NSCs, following primary and passage culture, were differentiated with serum culture medium (DMEM/F12 + 10% fetal bovine serum + 2 ng/mL brain-derived nerve growth factor + 2 ng/mL type-1 insulin like growth factor). MAIN OUTCOME MEASURES: Expression of a -actinin in neuron-like cells was quantitatively and qualitatively detected with immunocytochemistry using energy dispersive X-ray analysis. RESULTS: Immunocytochemistry, combined with electron microscopy, indicated that positive α -actinin expression was like a spheroid particle with high electron density. In addition, the expression was gradually concentrated from the nuclear edge to the cytoplasm and expanded into developing neurites, during differentiation of neural stem cells to neurons. Conversely, energy dispersive X-ray analysis indicated that the more mature the neural differentiation was, and the greater the expression of α -actinin. CONCLUSION: The gradual increase of α -actinin expression is related to growth, development, and maturity of differentiated neuron-like cells, in neonatal rat frontal lobe cortex, at different differentiating time points of NSCs to neurons.展开更多
A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus.The criterion of standardless X-ray diffraction analysis was suggested,so as ...A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus.The criterion of standardless X-ray diffraction analysis was suggested,so as to separate the diffraction pattern of every phase from that of sample.The optimal solution could be obtained by the least squares regression.展开更多
A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus,The criterion of standardless X-ray diffraction analysis was suggested,so as ...A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus,The criterion of standardless X-ray diffraction analysis was suggested,so as to separate the diffraction pattern of every phase from that of sample.The optimal solution could be obtained by the least squares regression.展开更多
Accuracy of coeffcient A_(isp) is related to the reference phase chosen during analysis. The cri- terion of choosing reference phase which may minimize the error of A_(isp) was deduced. The optimum results could be ob...Accuracy of coeffcient A_(isp) is related to the reference phase chosen during analysis. The cri- terion of choosing reference phase which may minimize the error of A_(isp) was deduced. The optimum results could be obtained by using the method of least squares if the number of sam- pies for analysis is more than the phase in samples. The procedure presented here is satisfacto- ryfor ordinary phase analysis.展开更多
基金Project supported by the Project of the Anhui Provincial Natural Science Foundation(Grant No.2308085MA19)Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDA0410401)+2 种基金the National Natural Science Foundation of China(Grant No.52202120)the National Key Research and Development Program of China(Grant No.2023YFA1609800)USTC Research Funds of the Double First-Class Initiative(Grant No.YD2310002013)。
文摘Small angle x-ray scattering(SAXS)is an advanced technique for characterizing the particle size distribution(PSD)of nanoparticles.However,the ill-posed nature of inverse problems in SAXS data analysis often reduces the accuracy of conventional methods.This article proposes a user-friendly software for PSD analysis,GranuSAS,which employs an algorithm that integrates truncated singular value decomposition(TSVD)with the Chahine method.This approach employs TSVD for data preprocessing,generating a set of initial solutions with noise suppression.A high-quality initial solution is subsequently selected via the L-curve method.This selected candidate solution is then iteratively refined by the Chahine algorithm,enforcing constraints such as non-negativity and improving physical interpretability.Most importantly,GranuSAS employs a parallel architecture that simultaneously yields inversion results from multiple shape models and,by evaluating the accuracy of each model's reconstructed scattering curve,offers a suggestion for model selection in material systems.To systematically validate the accuracy and efficiency of the software,verification was performed using both simulated and experimental datasets.The results demonstrate that the proposed software delivers both satisfactory accuracy and reliable computational efficiency.It provides an easy-to-use and reliable tool for researchers in materials science,helping them fully exploit the potential of SAXS in nanoparticle characterization.
基金supported by the National Natural Science Foundation of China(No.12175158)the Institute of Nuclear Physics and Chemistry,China Academy of Engineering Physics(No.HG2022022)。
文摘β-ray-induced X-ray spectroscopy(BIXS)is a promising technique for tritium analysis that offers several unique advantages,including substantial detection depth,nondestructive testing capabilities,and ease of operation.For thin solid tritium-containing samples with substrates,the currently used BIXS analysis method can measure the tritium depth profile and content when the sample thickness is known.In this study,a backpropagation(BP)neural network algorithm was used to predict the tritium content and thickness of a thin solid tritium-containing sample with substrates and a uniformly distributed tritium profile.A semi-analytical method was used to generate datasets for training and testing the BP neural network.A dataset ofβ-decay X-ray spectra from 420 tritium-containing zirconium models with different known thicknesses and tritium-tozirconium ratios was used as the input data.The corresponding zirconium thicknesses and tritium-to-zirconium ratios served as the output for training and testing the BP neural network.The mean relative errors(MREs)of the zirconium thickness in the training and test datasets were 0.56%and 0.42%,respectively,whereas the MREs of the tritium-to-zirconium ratio were 0.59%and 0.38%,respectively.Furthermore,the trained BP neural network demonstrates excellent predictive capability across various levels of statistical uncertainty.For the experimentalβ-decay X-ray spectra of two tritium-containing samples,the predicted zirconium thicknesses and tritium-to-zirconium ratios showed good agreement with the results obtained through the elastic backscattering spectrometry(EBS).
基金Project(DP140102355)supported by the Australian Research Council(ARC)Project supported by the China Scholarship Council(CSC)
文摘Synchrotron polychromatic X-ray microdiffraction(micro-XRD) was applied to study in situ deformation twinning of commercially AZ31(Mg-3Al-1Zn) strip subjected to uniaxial tension.The morphology and growth of twins were analyzed in situ under the load level from 64 to 73 MPa.The X-ray microdiffraction data,collected on beamline 12.3.2 at the Advanced Light Source,were then used to map an area of 396μm x 200μm within the region of interest.The experimental set-up and X-ray diffraction microscopy with a depth resolution allow the position and orientation of each illuminated grain to be determined at the submicron size.A list of parent grains sorted by crystallographic orientation were selected to examine their twinning behavior.The results depict twin variant selection,local misorientation fluctuation and mosaic spread for multi-twins within the same parent grain.As load increases,the amplitude of misorientation fluctuation along twin trace keeps increasing.This is attributable to the accumulation of geometrically necessary dislocations.
基金Supported by China Ministry of Science and Technology (2000DEB20081)China Ocean Mineral Resources R&D Association (COMRA) (No.DY105-05-01-05)+1 种基金China Ministry of Education(No.205089)China National Natural Science Foundation (No.40076015)
文摘A method was developed for content determination of Na, Mg, A1, Si, P,S, C1, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Nb, Zr, Y, Sr, Rb, Ba, La and Ce etc. covering 26 major, minor, and trace elements in marine sediment samples using fused glass disc by X-ray Fluorescence spectrometry. Calibration was made using marine sediment certified reference materials and the synthetic standard samples prepared by mixing several marine sediments with stream sediment and carbonate standard samples in different proportions. The matrix effect was corrected using theoretical alpha coefficients, experience coefficients and the scattered radiation as the internal standard (for the trace elements). The accuracy of the method was evaluated by analysis of certified reference materials GBW07314, GBW07334 and GSMS6. The results are in good agreement with the certified values of the standards with RSD less than 2.60%, except for Y, Cr, Ga, Ce, La, Nb, Rb, and V with RSD less than 9.0% (n=12).
基金financially supported by the National Natural Science Foundation of China(No.51304076)the Natural Science Foundation of Hunan Province,China(No.14JJ4064)
文摘Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance.To quantify the mineral dissemination and pore space distribution of an ore particle,a cylindrical copper oxide ore sample(I center dot 4.6 mm x 5.6 mm)was scanned using high-resolution X-ray computed tomography(HRXCT),a nondestructive imaging technology,at a spatial resolution of 4.85 mu m.Combined with three-dimensional(3D)image analysis techniques,the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated.In addition,the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques.Furthermore,the pore phase features,including the pore size distribution,pore surface area,pore fractal dimension,pore centerline,and the pore connectivity,were investigated quantitatively.The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated,with a large surface area and low connectivity.This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data.
基金supported by the National Key R&D Project of China(No.2017YFC0602100)the National Natural Science Foundation of China(No.41774147)Sichuan Science and Technology Support Program(No.2015GZ0272)
文摘The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.
文摘A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory.
文摘To examine accuracy of body composition predicted by the Multi-Frequency Bioelectric Impedance Analysis (MF-BIA) compared with the Dual-energy X-ray Absorptiometry (DXA) in adults with obese. We measured body composition of 749 adults with obese both by the MF-BIA and DXA. The Lin's concordance correlation and the Bland-Altman plots were used to examine the consistency. The concordance correlation coefficient of %BF between the MF-BIA and DXA in men and women was 0.560, and 0.669, respectively. Compared with the DXA, the MF-BIA significantly underestimated %BF by 4.33% in men (P 〈 0.001), however overestimated %BF by 0.50% in women (P 〈 0.001). After corrected by the correction equations established in this study, the differences were significantly decreased. Therefore, the MF-BIA (TANITA MC-180) may need to be corrected in estimating body composition for adults with obese.
基金supported by National Energy R&D Center of Petroleum Refining Technology of China(RIPP,SINOPEC)National Key Research and Development Program of China(No.2017YFA0304203)+5 种基金Changjiang Scholars and Innovative Research Team in University of Ministry of Education of China(No.IRT_17R70)National Natural Science Foundation of China(Nos.61975103,61875108,61775125 and 11434007)Industrial Application Innovation Project(No.627010407)Scientific and Technological Innovation Project of Shanxi Gemeng US-China Clean Energy R&D Center Co.,Ltd111 Project(D18001)Fund for Shanxi‘1331KSC’。
文摘Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in thermal power plants,the measurement repeatability of LIBS needs to be further improved due to the difficulty in controlling the stability of the generated plasmas at present.In this paper,we propose a novel x-ray fluorescence(XRF) assisted LIBS method for high repeatability analysis of coal quality,which not only inherits the ability of LIBS to directly analyze organic elements such as C and H in coal,but also uses XRF to make up for the lack of stability of LIBS in determining other inorganic ash-forming elements.With the combination of elemental lines in LIBS and XRF spectra,the principal component analysis and the partial least squares are used to establish the prediction model and perform multi-elemental and proximate analysis of coal.Quantitative analysis results show that the relative standard deviation(RSD) of C is 0.15%,the RSDs of other elements are less than 4%,and the standard deviations of calorific value,ash content,sulfur content and volatile matter are 0.11 MJ kg,0.17%,0.79% and 0.41%respectively,indicating that the method has good repeatability in determination of coal quality.This work is helpful to accelerate the development of LIBS in the field of rapid measurement of coal entering the power plant and on-line monitoring of coal entering the furnace.
文摘Stoichiometric hydroxyapatite(HA)nanoparticles were synthesized by a wet chemical method.Calcium nitrate tetra hydrate used as calcium source and dibasic ammonium phosphate used as phosphorous source.Calcium nitrate tetra hydrate and dibasic ammonium phosphate solutions were prepared by dissolving the salts in distilled water.Stoichiometric hydroxyapatite nanoparticles used by artificial bone powders and synthesized by a wet chemical method were analyzed using EDXRF method.The concentrations of K,Ca,Ti,V,Cr,Fe,Ni,Cu,Sr and Pb for artificial bone powders have been determined.Besides,Calcium contents were evaluated according to the agitation time and temperature in the production process.
基金This work was financially supported by the National Natural Science Foundation of China(No.42102217)the University Synergy Innovation Program of Anhui Province(No.GXXT-2021-018)+3 种基金the Natural Science Research Project of Anhui University(No.KJ2020A0315No.KJ2020A0317)the Natural Science Foundation of Anhui Province(No.2108085MD134)the Foundation of State Key Laboratory of Petroleum Resources and Prospecting,China University of Petroleum,Beijing(No.PRP/open-2005).
文摘Matrix swelling effect will cause the change of microstructure of coal reservoir and its permeability,which is the key factor affecting the engineering effect of CO_(2)-ECBM technology.The Sihe and Yuwu collieries are taken as research objects.Firstly,visualization reconstruction of coal reservoir is realized.Secondly,the evolution of the pore/fracture structures under different swelling contents is discussed.Then,the influence of matrix phase with different swelling contents on permeability is discussed.Finally,the mechanism of swelling effect during the CO_(2)-ECBM process is further discussed.The results show that the intra-matrix pores and matrix-edge fractures are the focus of this study,and the contacting area between matrix and pore/fracture is the core area of matrix swelling.The number of matrix particles decreases with the increase of size,and the distribution of which is isolated with small size and interconnected with large size.The swelling effect of matrix particles with larger size has a great influence on the pore/fracture structures.The number of connected pores/fractures is limited and only interconnected in a certain direction.With the increase of matrix swelling content,the number,porosity,width,fractal dimension,surface area and volume of pores/fractures decrease,and their negative contribution to absolute permeability increases from 0.368% to 0.633% and 0.868%-1.404%,respectively.With the increase of swelling content,the number of intra-matrix pores gradually decreases and the pore radius becomes shorter during the CO_(2)-ECBM process.The matrix continuously expands to the connected fractures,and the width of connected fractures gradually shorten.Under the influence of matrix swelling,the bending degree of fluid flow increases gradually,so the resistance of fluid migration increases and the permeability gradually decreases.This study shows that the matrix swelling effect is the key factor affecting CBM recovery,and the application of this effect in CO_(2)-ECBM process can be discussed.
文摘X-ray fluorescence (XRF) analysis utilizes particle size which is resulted from milling of a material. The milling ensures uniform and fine grained powder. The finer and more uniform the particle size is, the better the result and easier it is for material quality control. To ensure uniformity in particle size and finer powder, a comparative analysis was conducted with different grinding aids and pressed pellet method was used in obtaining analysis results. Pressed pellets of cement raw meal sample milled with different grinding aids (graphite, aspirin and lithium borate) were subjected to XRF. Graphite produced better particle size uniformity with a corresponding standard deviation that made quality control of raw meal easier and better than aspirin and lithium borate.
文摘The density,nature of the dislocations and distribution of the domain sizes in cold-deformed Pb-Ca-Sn solid solution were determined by X-ray diffraction profile analysis.The dislocation densities are of the order of 1010 cm-2.The strain broadening of diffraction profiles was accounted for by dislocation contrast factor.The coherent domain size was determined by the recently developed PM2K software package.Assuming that the domain size distribution is log-normal,the distribution function(median μ and variance σ) was calculated from the size parameters determined from X-ray diffraction profile analysis.
基金Supported by the National Key Research and Development Program of China,No.2017YFA0105404。
文摘BACKGROUND Conventional plain X-ray images of rats,the most common animals used as degeneration models,exhibit unclear vertebral structure and blurry intervertebral disc spaces due to their small size,slender vertebral bodies.AIM To apply molybdenum target X-ray photography in the evaluation of caudal intervertebral disc(IVD)degeneration in rat models.METHODS Two types of rat caudal IVD degeneration models(needle-punctured model and endplate-destructed model)were established,and their effectiveness was verified using nuclear magnetic resonance imaging.Molybdenum target inspection and routine plain X-ray were then performed on these models.Additionally,four observers were assigned to measure the intervertebral height of degenerated segments on molybdenum target plain X-ray images and routine plain X-ray images,respectively.The degeneration was evaluated and statistical analysis was subsequently conducted.RESULTS Nine rats in the needle-punctured model and 10 rats in the endplate-destructed model were effective.Compared with routine plain X-ray images,molybdenum target plain X-ray images showed higher clarity,stronger contrast,as well as clearer and more accurate structural development.The McNemar test confirmed that the difference was statistically significant(P=0.031).In the two models,the reliability of the intervertebral height measured by the four observers on routine plain X-ray images was poor(ICC<0.4),while the data obtained from the molybdenum target plain X-ray images were more reliable.CONCLUSIONMolybdenum target inspection can obtain clearer images and display fine calcification in the imaging evaluation of caudal IVD degeneration in rats,thus ensuring a more accurate evaluation of degeneration.
文摘Results of researches on plastic deformation of steels were obtained by acoustic emission and X-ray methods.The new numerical-analytical method of the thin structure parameter determination on one diffraction line was offered.It is supposed that with a growth of the deformation the cubic lattice will be transformed in the orthorhombic lattice.It is shown that changes of a condition of crystal structure of austenitic steel occur in four stages and of carbonaceous steel occur in six stages.Existence of two types of acoustic emission sources in carbonaceous steel and one type of acoustic emission source in austenitic steel was proposed.
文摘A new method for quantitative X-ray diffraction phase analysis of a powder misture has been developed according to Popovic's doping method. The weight fraction of amorphous material in the analysed sample is obtained. For a multicomponent system in which (n-2) pure phases are added into an n-phase compnent sample and theweight fractions of all n phases can be determined by the method. The test results of confirmation agree well with the theory.
基金Supported by:the National Natural Science Foundation of China,No.39970383the Project for Science and Technology from Educational Committee of Liaoning Province,No.202013132Technological Program for Colleges and Universities of Liaoning Educational Committee,No.[2008]84
文摘BACKGROUND: Alpha-actinin ( a -actinin) plays a key role in neuronal growth cone migration during directional differentiation from neural stem cells (NSCs) to neurons. OBJECTIVE: To detect in situ microdistribution and quantitative expression of a -actinin during directional differentiation of NSCs to neurons in the temporal lobe cerebral cortex of neonatal rats. DESIGN, TIME AND SETTING: Between January 2006 and December 2008, culture and directional differentiation of NSCs were performed at Department of Histology and Embryology, Preclinical Medical College, China Medical University. Immune electron microscopy was performed at Department of Histology and Embryology and Department of Electron Micrology, Preclinical Medical College, China Medical University. Spectrum analysis was performed at Laboratory of Electron Microscopy, Mental Research Institute, Chinese Academy of Sciences. MATERIALS: Basic fibroblast growth factor, epidermal growth factor, brain-derived nerve growth factor, type-1 insulin like growth factor, and a -actinin antibody were provided by Gibco BRL, USA; rabbit-anti-rat nestin monoclonal antibody, rabbit-anti-rat neuron specific enolase polyclonal antibody, and EDAX-9100 energy dispersive X-ray analysis were provided by PHILIPS Company, Netherlands. METHODS: NSCs, following primary and passage culture, were differentiated with serum culture medium (DMEM/F12 + 10% fetal bovine serum + 2 ng/mL brain-derived nerve growth factor + 2 ng/mL type-1 insulin like growth factor). MAIN OUTCOME MEASURES: Expression of a -actinin in neuron-like cells was quantitatively and qualitatively detected with immunocytochemistry using energy dispersive X-ray analysis. RESULTS: Immunocytochemistry, combined with electron microscopy, indicated that positive α -actinin expression was like a spheroid particle with high electron density. In addition, the expression was gradually concentrated from the nuclear edge to the cytoplasm and expanded into developing neurites, during differentiation of neural stem cells to neurons. Conversely, energy dispersive X-ray analysis indicated that the more mature the neural differentiation was, and the greater the expression of α -actinin. CONCLUSION: The gradual increase of α -actinin expression is related to growth, development, and maturity of differentiated neuron-like cells, in neonatal rat frontal lobe cortex, at different differentiating time points of NSCs to neurons.
文摘A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus.The criterion of standardless X-ray diffraction analysis was suggested,so as to separate the diffraction pattern of every phase from that of sample.The optimal solution could be obtained by the least squares regression.
文摘A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus,The criterion of standardless X-ray diffraction analysis was suggested,so as to separate the diffraction pattern of every phase from that of sample.The optimal solution could be obtained by the least squares regression.
文摘Accuracy of coeffcient A_(isp) is related to the reference phase chosen during analysis. The cri- terion of choosing reference phase which may minimize the error of A_(isp) was deduced. The optimum results could be obtained by using the method of least squares if the number of sam- pies for analysis is more than the phase in samples. The procedure presented here is satisfacto- ryfor ordinary phase analysis.