High resolution Fresnel zone plates for nanoscale three-dimensional imaging of materials by both soft and hard x-rays are increasingly needed by the broad applications in nanoscience and nanotechnology.When the outmos...High resolution Fresnel zone plates for nanoscale three-dimensional imaging of materials by both soft and hard x-rays are increasingly needed by the broad applications in nanoscience and nanotechnology.When the outmost zone-width is shrinking down to 50 nm or even below,patterning the zone plates with high aspect ratio by electron beam lithography still remains a challenge because of the proximity effect.The uneven charge distribution in the exposed resist is still frequently observed even after standard proximity effect correction(PEC),because of the large variety in the line width.This work develops a new strategy,nicknamed as local proximity effect correction(LPEC),efficiently modifying the deposited energy over the whole zone plate on the top of proximity effect correction.By this way,50 nm zone plates with the aspect ratio from 4:1 up to 15:1 and the duty cycle close to 0.5 have been fabricated.Their imaging capability in soft(1.3 keV)and hard(9 keV)x-ray,respectively,has been demonstrated in Shanghai Synchrotron Radiation Facility(SSRF)with the resolution of 50 nm.The local proximity effect correction developed in this work should also be generally significant for the generation of zone plates with high resolutions beyond 50 nm.展开更多
Effects of tie beam length, width and overlap stress on settlement of foundations have been investigated. In this investigation square concrete footings have been used with dimensions (B × B × d) where (d) i...Effects of tie beam length, width and overlap stress on settlement of foundations have been investigated. In this investigation square concrete footings have been used with dimensions (B × B × d) where (d) is footing depth and (B) is footing width (1, 1.5,2 m). Width of tie beam (b) has been taken equal to 0.25, 0.30, 0.40, 0.50 and 0.75 (m). Tie beam length (L) has been taken varying from B till 3B with same footing depth = 0.50 m. Effect of overlap stress on settlement as well as effect of tie beam width and length on settlement has been determined. Also, the efficiency of tie beam length and width has been obtained. An equation is presented to compute the overlap stress zone in case of existing tie beam. It is found that the settlement increases with increasing the length of tie beam which is clear after the effect of the overlap stresses zone. The width of overlap stress zone case of existing tie beam has been found to be equal to (1.6 -1.75) B. The settlement of footings decreases with increasing tie beam width. It is found that the settlement after the effect of the overlap stress zone increases with increasing the length of tie beam.展开更多
This paper presents an experimental study investigating factors influencing the effective width of steel reinforced concrete (SRC) column-steel beam joints of building in order to calculate its resisting moment.Five 1...This paper presents an experimental study investigating factors influencing the effective width of steel reinforced concrete (SRC) column-steel beam joints of building in order to calculate its resisting moment.Five 1/2 scaled interior SRC column-steel beam joint specimens were made with considering parameters such as beam flange width,beam depth and SRC column width.One directional increasing moment was applied to the joint by acting forces to each ends of beam and the structural behavior of joint was studied.And previous design method suggested by Deierlein was reviewed and a modified equation was proposed from the analysis of test result.Test result indicated that the equation to calculate the effective width in Deierlein’s design method didn’t consider effectively the influence caused by the variation of beam depth so that a modified equation was suggested and the validation of it was confirmed in this paper.展开更多
Background Compared with the traditional monochromatic synchrotron radiation beam,a pink beam is a quasimonochromatic beam which can be obtained by screening a harmonic of the undulator.The energy bandwidth(E/E)of a ...Background Compared with the traditional monochromatic synchrotron radiation beam,a pink beam is a quasimonochromatic beam which can be obtained by screening a harmonic of the undulator.The energy bandwidth(E/E)of a pink beam is about 10−2.Despite the intensity gain from the quasi-monochromatic beam,the decrease in the energy resolution will lead the collected data to be smeared.Purpose To study the influence of the energy bandwidth on the small angle X-ray scattering(SAXS)by experiments and verify the feasibility of SAXS with a pink beam.Method Firstly,the influence of different energy bandwidths on SAXS has been studied by simulation and experiment.Then,TEM tests have been performed and compared with the experimental results.Result It has been shown that the scattering curves deviate slightly from the traditional monochromatic ones.This deviation does not influence the data processing for the maximum deviation of the results is just less than 2%.In return,the gain in the intensity(one to two orders of magnitude)makes the pink beam very important for the time-resolved SAXS.Further,the results of TEM and SAXS have shown an excellent agreement.Conclusion Thiswork proves that the pink beam could be used for SAXS directly without a desmearing procedure.Benefiting from the increase in the beam intensity,the exposure time can be greatly shortened,thus enhancing the utilization efficiency of the synchrotron radiation.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.U1732104)China Postdoctoral Science Foundation(Grant No.2017M611443)Shanghai STCSM2019-11-20 Grant,China(Grant No.19142202700)。
文摘High resolution Fresnel zone plates for nanoscale three-dimensional imaging of materials by both soft and hard x-rays are increasingly needed by the broad applications in nanoscience and nanotechnology.When the outmost zone-width is shrinking down to 50 nm or even below,patterning the zone plates with high aspect ratio by electron beam lithography still remains a challenge because of the proximity effect.The uneven charge distribution in the exposed resist is still frequently observed even after standard proximity effect correction(PEC),because of the large variety in the line width.This work develops a new strategy,nicknamed as local proximity effect correction(LPEC),efficiently modifying the deposited energy over the whole zone plate on the top of proximity effect correction.By this way,50 nm zone plates with the aspect ratio from 4:1 up to 15:1 and the duty cycle close to 0.5 have been fabricated.Their imaging capability in soft(1.3 keV)and hard(9 keV)x-ray,respectively,has been demonstrated in Shanghai Synchrotron Radiation Facility(SSRF)with the resolution of 50 nm.The local proximity effect correction developed in this work should also be generally significant for the generation of zone plates with high resolutions beyond 50 nm.
文摘Effects of tie beam length, width and overlap stress on settlement of foundations have been investigated. In this investigation square concrete footings have been used with dimensions (B × B × d) where (d) is footing depth and (B) is footing width (1, 1.5,2 m). Width of tie beam (b) has been taken equal to 0.25, 0.30, 0.40, 0.50 and 0.75 (m). Tie beam length (L) has been taken varying from B till 3B with same footing depth = 0.50 m. Effect of overlap stress on settlement as well as effect of tie beam width and length on settlement has been determined. Also, the efficiency of tie beam length and width has been obtained. An equation is presented to compute the overlap stress zone in case of existing tie beam. It is found that the settlement increases with increasing the length of tie beam which is clear after the effect of the overlap stresses zone. The width of overlap stress zone case of existing tie beam has been found to be equal to (1.6 -1.75) B. The settlement of footings decreases with increasing tie beam width. It is found that the settlement after the effect of the overlap stress zone increases with increasing the length of tie beam.
基金supported by a grant from the Academic Research Program of Chungju National University in 2011
文摘This paper presents an experimental study investigating factors influencing the effective width of steel reinforced concrete (SRC) column-steel beam joints of building in order to calculate its resisting moment.Five 1/2 scaled interior SRC column-steel beam joint specimens were made with considering parameters such as beam flange width,beam depth and SRC column width.One directional increasing moment was applied to the joint by acting forces to each ends of beam and the structural behavior of joint was studied.And previous design method suggested by Deierlein was reviewed and a modified equation was proposed from the analysis of test result.Test result indicated that the equation to calculate the effective width in Deierlein’s design method didn’t consider effectively the influence caused by the variation of beam depth so that a modified equation was suggested and the validation of it was confirmed in this paper.
基金a grant from the National Key R&D Plan of China(Grant No.2016YFA0401300).
文摘Background Compared with the traditional monochromatic synchrotron radiation beam,a pink beam is a quasimonochromatic beam which can be obtained by screening a harmonic of the undulator.The energy bandwidth(E/E)of a pink beam is about 10−2.Despite the intensity gain from the quasi-monochromatic beam,the decrease in the energy resolution will lead the collected data to be smeared.Purpose To study the influence of the energy bandwidth on the small angle X-ray scattering(SAXS)by experiments and verify the feasibility of SAXS with a pink beam.Method Firstly,the influence of different energy bandwidths on SAXS has been studied by simulation and experiment.Then,TEM tests have been performed and compared with the experimental results.Result It has been shown that the scattering curves deviate slightly from the traditional monochromatic ones.This deviation does not influence the data processing for the maximum deviation of the results is just less than 2%.In return,the gain in the intensity(one to two orders of magnitude)makes the pink beam very important for the time-resolved SAXS.Further,the results of TEM and SAXS have shown an excellent agreement.Conclusion Thiswork proves that the pink beam could be used for SAXS directly without a desmearing procedure.Benefiting from the increase in the beam intensity,the exposure time can be greatly shortened,thus enhancing the utilization efficiency of the synchrotron radiation.