AIM: To investigate the characteristics of postoperative central visual field defect(cVFD) in patients with macular hole(MH).METHODS: Eighteen eyes from 18 MH patients were involved in this retrospective study which r...AIM: To investigate the characteristics of postoperative central visual field defect(cVFD) in patients with macular hole(MH).METHODS: Eighteen eyes from 18 MH patients were involved in this retrospective study which reviewed square root of loss variance(sLV) and mean defect(MD) of the visual field test in all subjects. The relationship between cVFD and MH stage, as well as the postoperative ellipsoid zone disruption were evaluated using Spearman's correlation test. RESULTS: Our analysis determined Spearman coefficient is 0.705 for the correlation between sLV and MH stage(P<0.01), 0.877 for the correlation between sLV and postoperative ellipsoid zone disruption(P<0.01) and 0.721 for the correlation between MD and postoperative ellipsoid zone disruption(P<0.01). A significant relationship was also detected between postoperative ellipsoid zone disruption and MH stage(r=0.470, P<0.05). Univariate regression analysis indicated that sLV and MD were associated with postoperative ellipsoid zone disruption(P<0.01, P<0.01, respectively). CONCLUSION: Postoperative cVFD is highly correlated with MH stage and postoperative ellipsoid zone disruption in patients with MH.展开更多
In this paper, the X-ray nondestructive test method of small defects in precision weldments with complex structure was presented. To resolve the difficulty of defect segmentation in variable grey image, the image proc...In this paper, the X-ray nondestructive test method of small defects in precision weldments with complex structure was presented. To resolve the difficulty of defect segmentation in variable grey image, the image processing based on Visual Basic programming method was adopted. The methods of automatic contrast and partial grey stretch were used to enhance the X-ray detection image which has relatively low contrast, then automatic threshold method was carried out to segment the two high intensity zones, and weld zones which contain the small defects was extracted. Smoothing and sharpen processing were proceeded on the extracted weld zones, and small defects in X-ray detection image of weldments with complex structure were segmented by using the method of background subtraction in the end. The effects of raster were eliminated, and because of that the image processing was only proceeded on the extracted weld zones, the calculated speed using the above provided algorithm was improved.展开更多
AIM: To show the efficacy of reconstruction and rehabilitation of large acquired maxillofacial defects due to tumor resections and firearm injuries. METHODS: The study group comprised of 16 patients(10 men and 6 women...AIM: To show the efficacy of reconstruction and rehabilitation of large acquired maxillofacial defects due to tumor resections and firearm injuries. METHODS: The study group comprised of 16 patients(10 men and 6 women) who were operated on because of their maxillofacial defects under local and general anesthesia between June 2007 and June 2011. Prosthetic treatment with the aid of dental implants was performed for all of the patients. Eight patients received an implant supported fixed prosthesis; six patients received implant supported overdentures and two patients received both. Patients were followed up postoperatively for 1 to 4 years. Implant success and survival rates were recorded. Panoramic radiographs were taken preoperatively, immediately after surgery, immediately after loading and at every recall session. Peri-implant and prosthetic complications were recorded. Subjects were asked to grade their oral health satisfaction after treatment according to 100 mm visual analog scale(VAS) and the oral health related quality oflife of the patients was measured with the short-form Oral Health Impact Profile. RESULTS: Five implants(3 in the mandible, 2 in the maxilla) in five patients were lost, while the other 53 survived, which brings an overall survival rate of 91.37% on the implant basis, but 68.75% on patient basis. All the failed implants were lost before abutment connection and were therefore regarded as early failures. For all failed implants, new implants were placed after a 2 mo period and the planning was maintained. The mean marginal bone loss(MBL) was 1.4 mm on the mesial side and 1.6 mm on the distal side of the implants. Five of the implants showed MBL > 2 mm(mean MBL = 2.3 mm) but less than 1/2 of the implant bodies and therefore were regarded as not successful but surviving implants. The VAS General Comfort mean score was 85.07, the VAS Speech mean score was 75.25 and the VAS Esthetics mean score was 82.74. No patient reported low scores(score lower than 50) of satisfaction in any of the evaluated factors. The mean of OHIP-14 scores was 5.5. CONCLUSION: Although further follow up and larger case numbers will give more information about the success of dental implants as a treatment modality in maxillofacial defects patients, the actual results are encouraging and can be recommended for similar cases.展开更多
Purpose: To report a rare case of visual allesthesia in a patient with glioblastoma multiforme. Material - Methods : A 46 – year old male presented in emergency ophthalmologic department complaining for difficulties ...Purpose: To report a rare case of visual allesthesia in a patient with glioblastoma multiforme. Material - Methods : A 46 – year old male presented in emergency ophthalmologic department complaining for difficulties in performing tasks related to color discrimination in his occupation (PC technician). The patient underwent a thorough ophthalmological examination and then he was referred to the neurological department for further evaluation. Results: The patient presented an atypical pattern of color perception disturbance. His best corrected visual acuity decreased progressively during hospitalization. He also experienced visual allesthesia paroxysmally (illusory left homonymous transpositions of subjects viewed in the right homonymous visual field). The visual field evaluation revealed homonymous left hemianopsia. Magnetic resonance imaging revealed glioblastoma multiforme confirmed by biopsy. Conclusions: A thorough ophthalmological and neuro-imaging control is suggested in patients with sudden color perception disturbance. Patients with temporal or occipital cortex damage may experience visual allesthesia.展开更多
Purpose : To investigate correlation of variation in the exon 5 of red and green pigment genes with color vision defects.Methods : Exon 5 of the red and green pigment genes in 11 protans, 19 deutans and 38 normal cont...Purpose : To investigate correlation of variation in the exon 5 of red and green pigment genes with color vision defects.Methods : Exon 5 of the red and green pigment genes in 11 protans, 19 deutans and 38 normal controls were analyzed by heteroduplux-SSCP analysis.Results : In all 11 protans and 8 of the 19 deutans, defects of the red or green pigment gene could be identified. The C polymorphism (A/C at codon 283) in green pigment gene was present in 8 of 44 trichromats and 5 of 24 dichromats. Specific electrophoretic bands were found in 2 normal controls and a deutan.Conclusions: Variation in the exon 5 of the red and green pigment genes is the most common cause for color vision defects. Heteroduplex-SSCP analysis is a suitable way in screening specific variation in visual pigment genes. Eye Science 1998; 14 : 130 - 133.展开更多
基金Supported by National Natural Science Foundation of China(No.81670865 No.81500743)Natural Science Foundation of Tianjin(No.16JCQNJC13000)
文摘AIM: To investigate the characteristics of postoperative central visual field defect(cVFD) in patients with macular hole(MH).METHODS: Eighteen eyes from 18 MH patients were involved in this retrospective study which reviewed square root of loss variance(sLV) and mean defect(MD) of the visual field test in all subjects. The relationship between cVFD and MH stage, as well as the postoperative ellipsoid zone disruption were evaluated using Spearman's correlation test. RESULTS: Our analysis determined Spearman coefficient is 0.705 for the correlation between sLV and MH stage(P<0.01), 0.877 for the correlation between sLV and postoperative ellipsoid zone disruption(P<0.01) and 0.721 for the correlation between MD and postoperative ellipsoid zone disruption(P<0.01). A significant relationship was also detected between postoperative ellipsoid zone disruption and MH stage(r=0.470, P<0.05). Univariate regression analysis indicated that sLV and MD were associated with postoperative ellipsoid zone disruption(P<0.01, P<0.01, respectively). CONCLUSION: Postoperative cVFD is highly correlated with MH stage and postoperative ellipsoid zone disruption in patients with MH.
文摘In this paper, the X-ray nondestructive test method of small defects in precision weldments with complex structure was presented. To resolve the difficulty of defect segmentation in variable grey image, the image processing based on Visual Basic programming method was adopted. The methods of automatic contrast and partial grey stretch were used to enhance the X-ray detection image which has relatively low contrast, then automatic threshold method was carried out to segment the two high intensity zones, and weld zones which contain the small defects was extracted. Smoothing and sharpen processing were proceeded on the extracted weld zones, and small defects in X-ray detection image of weldments with complex structure were segmented by using the method of background subtraction in the end. The effects of raster were eliminated, and because of that the image processing was only proceeded on the extracted weld zones, the calculated speed using the above provided algorithm was improved.
文摘AIM: To show the efficacy of reconstruction and rehabilitation of large acquired maxillofacial defects due to tumor resections and firearm injuries. METHODS: The study group comprised of 16 patients(10 men and 6 women) who were operated on because of their maxillofacial defects under local and general anesthesia between June 2007 and June 2011. Prosthetic treatment with the aid of dental implants was performed for all of the patients. Eight patients received an implant supported fixed prosthesis; six patients received implant supported overdentures and two patients received both. Patients were followed up postoperatively for 1 to 4 years. Implant success and survival rates were recorded. Panoramic radiographs were taken preoperatively, immediately after surgery, immediately after loading and at every recall session. Peri-implant and prosthetic complications were recorded. Subjects were asked to grade their oral health satisfaction after treatment according to 100 mm visual analog scale(VAS) and the oral health related quality oflife of the patients was measured with the short-form Oral Health Impact Profile. RESULTS: Five implants(3 in the mandible, 2 in the maxilla) in five patients were lost, while the other 53 survived, which brings an overall survival rate of 91.37% on the implant basis, but 68.75% on patient basis. All the failed implants were lost before abutment connection and were therefore regarded as early failures. For all failed implants, new implants were placed after a 2 mo period and the planning was maintained. The mean marginal bone loss(MBL) was 1.4 mm on the mesial side and 1.6 mm on the distal side of the implants. Five of the implants showed MBL > 2 mm(mean MBL = 2.3 mm) but less than 1/2 of the implant bodies and therefore were regarded as not successful but surviving implants. The VAS General Comfort mean score was 85.07, the VAS Speech mean score was 75.25 and the VAS Esthetics mean score was 82.74. No patient reported low scores(score lower than 50) of satisfaction in any of the evaluated factors. The mean of OHIP-14 scores was 5.5. CONCLUSION: Although further follow up and larger case numbers will give more information about the success of dental implants as a treatment modality in maxillofacial defects patients, the actual results are encouraging and can be recommended for similar cases.
文摘Purpose: To report a rare case of visual allesthesia in a patient with glioblastoma multiforme. Material - Methods : A 46 – year old male presented in emergency ophthalmologic department complaining for difficulties in performing tasks related to color discrimination in his occupation (PC technician). The patient underwent a thorough ophthalmological examination and then he was referred to the neurological department for further evaluation. Results: The patient presented an atypical pattern of color perception disturbance. His best corrected visual acuity decreased progressively during hospitalization. He also experienced visual allesthesia paroxysmally (illusory left homonymous transpositions of subjects viewed in the right homonymous visual field). The visual field evaluation revealed homonymous left hemianopsia. Magnetic resonance imaging revealed glioblastoma multiforme confirmed by biopsy. Conclusions: A thorough ophthalmological and neuro-imaging control is suggested in patients with sudden color perception disturbance. Patients with temporal or occipital cortex damage may experience visual allesthesia.
基金This work was supported by the National Natural Science Foundation of China (39670776 Qingjiong Zhang) and the Returnee Startup Foundation of National Educational Committee of China (Qingjiong Zhang)
文摘Purpose : To investigate correlation of variation in the exon 5 of red and green pigment genes with color vision defects.Methods : Exon 5 of the red and green pigment genes in 11 protans, 19 deutans and 38 normal controls were analyzed by heteroduplux-SSCP analysis.Results : In all 11 protans and 8 of the 19 deutans, defects of the red or green pigment gene could be identified. The C polymorphism (A/C at codon 283) in green pigment gene was present in 8 of 44 trichromats and 5 of 24 dichromats. Specific electrophoretic bands were found in 2 normal controls and a deutan.Conclusions: Variation in the exon 5 of the red and green pigment genes is the most common cause for color vision defects. Heteroduplex-SSCP analysis is a suitable way in screening specific variation in visual pigment genes. Eye Science 1998; 14 : 130 - 133.