Rainfall monitoring is one of the most important meteorological observation elements for the disaster weather. The maintenance of current tipping bucket rain gauge and weighing type rain gauge is a critical issue. The...Rainfall monitoring is one of the most important meteorological observation elements for the disaster weather. The maintenance of current tipping bucket rain gauge and weighing type rain gauge is a critical issue. The optical rainfall sensor based on CCD linear array is mainly studied in this paper. Because of the maintenance-free time and good adaptability,it can be widely used in the automatic rainfall monitoring in severe environment and have a good perspective in using.展开更多
Crossed grating stuck to metal surface was used as a strain sensor in the present work, and stress as well as strain were then investigated by accurately determining the change in the position of diffraction spot befo...Crossed grating stuck to metal surface was used as a strain sensor in the present work, and stress as well as strain were then investigated by accurately determining the change in the position of diffraction spot before and after deformed. A hardware testing system for linear CCD array, data gathering and processing was therefore developed for this purpose. Experimental results showed that the system has a good accuracy and can be used to measure stress and strain of metal surface in a real-time and quantitative manner.展开更多
Spatial filtering velocimetry(SFV)has the advantages of simple structure,good stability,and wide applications.However,the traditional linear CCD-based SFV method requires an accurate angle between the direction of lin...Spatial filtering velocimetry(SFV)has the advantages of simple structure,good stability,and wide applications.However,the traditional linear CCD-based SFV method requires an accurate angle between the direction of linear CCD and the direction of moving object,so it is not suitable for measuring a complex flow field or two-dimensional speed in a granular media.In this paper,a new extension of spatial filtering method(SFM)based on high speed array CCD camera is proposed as simple and effective technique for measuring two-dimensional speed field of granular media.In particular,we analyzed the resolution and range of array CCD-based SFV so that the reader can clarify the application scene of this method.This method has a particular advantage for using orthogonal measurement to avoid the angle measurement,which were problematic when using linear CCD to measure the movement.Finally,the end-wall effects of the granular flow in rotating drum is studied with different experimental conditions by using this improved technique.展开更多
Aiming at the defects of routine settlement measurement methods, such as complicated procedures, time-consuming and labor-intensive, high cost and low measurement accuracy, based on the analysis of existing engineerin...Aiming at the defects of routine settlement measurement methods, such as complicated procedures, time-consuming and labor-intensive, high cost and low measurement accuracy, based on the analysis of existing engineering measurement technical requirements and specifications, a multi-point high precision and high efficiency based on laser reference is proposed. The automatic building settlement real-time monitoring system program gives the principle and system model of single-point settlement observation. The model of multi-point scanning settlement monitoring system and the model of multi-point network settlement monitoring system are designed, and their advantages and disadvantages are analyzed. We focus on the networked multi-point settlement monitoring system for network cumulative error analysis, and propose related evaluation and correction methods. The hardware schematic and software block diagram of the laser reference measurement and measurement system of the single point settlement acquisition system are given. Finally, the risk of subsidence state is quantitatively evaluated based on multi-point settlement monitoring data. The measurement error of this method is less than 300 μm, which can realize the monitoring and evaluation of the overall settlement.展开更多
A real-time auto-focusing system with auto-collimation method is introduced, which is used in auto-detecting the focus of the space camera with long focus. Auto-focusing is the key technique to ensure high quality in ...A real-time auto-focusing system with auto-collimation method is introduced, which is used in auto-detecting the focus of the space camera with long focus. Auto-focusing is the key technique to ensure high quality in space imaging. It can measure and compensate the defocus caused by the change of temperature and air pressure etc. in space. To solve the problem of auto-focusing with auto-collimation method of the camera whose axis is perpendicular to the ground, it is designed that two small caliber pentagonal prisms are placed in the area of aperture suitable to the camera’s relative aperture based on the theory of auto-focusing with auto-collimation, which can replace the big caliber plane reflector used in other cameras. Using the characteristic of pentagonal prism refracting light vertically, the target slit is imaged in CCD through the two-separated lens. It transforms the detecting of the axial defocusing quantity to the landscape orientation measurement of the faculae’s position in the direction of CCD pixels. The defocusing quantity is obtained by measuring the opposite position of the two faculae on the CCD. The Centroid method is adopted to measure the position of the auto-collimation faculae. The arithmetic error is analyzed especially, and the causation is given. Experiments show that this real-time auto-focusing system using centroid method is reliable and the focusing precision can reach ±0.01 mm.展开更多
The system of Integrated-Optics Acousto-Optic RF Spectrum Analyzer (IOAOSA)consists of a laser diode, an Acousto-Optic (A-O) modulator, geodesic lenses and CCD detectorarray. The optical signal projected on the CCD ar...The system of Integrated-Optics Acousto-Optic RF Spectrum Analyzer (IOAOSA)consists of a laser diode, an Acousto-Optic (A-O) modulator, geodesic lenses and CCD detectorarray. The optical signal projected on the CCD array is converted into electrical signal andprocessed by the signal processing center which consists of a TMS 32010 system and an IBM-PC.The TMS 32010 with very high speed is used in a microcomputer system. A cycle sample methodis adopted to collect the data of the CCD video signal, sampling one per 40-point. After theprocessing, the frequency bandwidth, the resolution and the dynamic range of the system aremeasured to be 100 MHz, 8 MHz and 20 dB, respectively.展开更多
基金supported by Meteorological Industry Research Projects ( 2013 ) : Research of Optical rainfall sensor
文摘Rainfall monitoring is one of the most important meteorological observation elements for the disaster weather. The maintenance of current tipping bucket rain gauge and weighing type rain gauge is a critical issue. The optical rainfall sensor based on CCD linear array is mainly studied in this paper. Because of the maintenance-free time and good adaptability,it can be widely used in the automatic rainfall monitoring in severe environment and have a good perspective in using.
文摘Crossed grating stuck to metal surface was used as a strain sensor in the present work, and stress as well as strain were then investigated by accurately determining the change in the position of diffraction spot before and after deformed. A hardware testing system for linear CCD array, data gathering and processing was therefore developed for this purpose. Experimental results showed that the system has a good accuracy and can be used to measure stress and strain of metal surface in a real-time and quantitative manner.
基金Project supported by the National Natural Science Foundation of China(Grant No.11902190)the Construction Project of Shanghai Key Laboratory of Molecular Imaging(Grant No.18DZ2260400)the Fund from the Shanghai Municipal Education Commission,China(Class II Plateau Disciplinary Construction Program of Medical Technology of SUMHS,2018-2020).
文摘Spatial filtering velocimetry(SFV)has the advantages of simple structure,good stability,and wide applications.However,the traditional linear CCD-based SFV method requires an accurate angle between the direction of linear CCD and the direction of moving object,so it is not suitable for measuring a complex flow field or two-dimensional speed in a granular media.In this paper,a new extension of spatial filtering method(SFM)based on high speed array CCD camera is proposed as simple and effective technique for measuring two-dimensional speed field of granular media.In particular,we analyzed the resolution and range of array CCD-based SFV so that the reader can clarify the application scene of this method.This method has a particular advantage for using orthogonal measurement to avoid the angle measurement,which were problematic when using linear CCD to measure the movement.Finally,the end-wall effects of the granular flow in rotating drum is studied with different experimental conditions by using this improved technique.
基金Supported by the Natural Science Foundation of Shaanxi Province(2018JM6023)the Science and Technology Project of Shaanxi Provincial Transportation Department(17-16K,17-33T)
文摘Aiming at the defects of routine settlement measurement methods, such as complicated procedures, time-consuming and labor-intensive, high cost and low measurement accuracy, based on the analysis of existing engineering measurement technical requirements and specifications, a multi-point high precision and high efficiency based on laser reference is proposed. The automatic building settlement real-time monitoring system program gives the principle and system model of single-point settlement observation. The model of multi-point scanning settlement monitoring system and the model of multi-point network settlement monitoring system are designed, and their advantages and disadvantages are analyzed. We focus on the networked multi-point settlement monitoring system for network cumulative error analysis, and propose related evaluation and correction methods. The hardware schematic and software block diagram of the laser reference measurement and measurement system of the single point settlement acquisition system are given. Finally, the risk of subsidence state is quantitatively evaluated based on multi-point settlement monitoring data. The measurement error of this method is less than 300 μm, which can realize the monitoring and evaluation of the overall settlement.
文摘A real-time auto-focusing system with auto-collimation method is introduced, which is used in auto-detecting the focus of the space camera with long focus. Auto-focusing is the key technique to ensure high quality in space imaging. It can measure and compensate the defocus caused by the change of temperature and air pressure etc. in space. To solve the problem of auto-focusing with auto-collimation method of the camera whose axis is perpendicular to the ground, it is designed that two small caliber pentagonal prisms are placed in the area of aperture suitable to the camera’s relative aperture based on the theory of auto-focusing with auto-collimation, which can replace the big caliber plane reflector used in other cameras. Using the characteristic of pentagonal prism refracting light vertically, the target slit is imaged in CCD through the two-separated lens. It transforms the detecting of the axial defocusing quantity to the landscape orientation measurement of the faculae’s position in the direction of CCD pixels. The defocusing quantity is obtained by measuring the opposite position of the two faculae on the CCD. The Centroid method is adopted to measure the position of the auto-collimation faculae. The arithmetic error is analyzed especially, and the causation is given. Experiments show that this real-time auto-focusing system using centroid method is reliable and the focusing precision can reach ±0.01 mm.
基金Supported by National "863" High Technology Plans of China
文摘The system of Integrated-Optics Acousto-Optic RF Spectrum Analyzer (IOAOSA)consists of a laser diode, an Acousto-Optic (A-O) modulator, geodesic lenses and CCD detectorarray. The optical signal projected on the CCD array is converted into electrical signal andprocessed by the signal processing center which consists of a TMS 32010 system and an IBM-PC.The TMS 32010 with very high speed is used in a microcomputer system. A cycle sample methodis adopted to collect the data of the CCD video signal, sampling one per 40-point. After theprocessing, the frequency bandwidth, the resolution and the dynamic range of the system aremeasured to be 100 MHz, 8 MHz and 20 dB, respectively.