A test flow description language is designed for the description of test flow.The design concept,composition,program structure and syntax structure of statement are presented.The development and impletementation proce...A test flow description language is designed for the description of test flow.The design concept,composition,program structure and syntax structure of statement are presented.The development and impletementation processes of the language are also described.This language is independent of hardware,which can be used for different platforms,and can be extended.The language is used to describe the test flow easily.It simplifies the development process of test software and reduces the difficulty of software maintenance greatly.展开更多
In this work,a novel conjugate of ractopamine and bovine serum albumin(RAC–BSA)has been developed via the Mannich reaction,with a mole coupling ratio for RAC–BSA of 9:1.The proposed conjugation method provides a sim...In this work,a novel conjugate of ractopamine and bovine serum albumin(RAC–BSA)has been developed via the Mannich reaction,with a mole coupling ratio for RAC–BSA of 9:1.The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays.RAC–BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed.For sample preparation,RAC was spiked in swine feed purchased from the local markets in Thailand,and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer.The procedures for sample preparation were completed within 25 min.Under optimal conditions,the limit of detection(LOD),assessed by the naked eye within 5 min,was found to be 1 ng/g.A semi-quantitative analysis was also conducted using a smart phone and computer software,with a linearity of 0.075–0.750 ng/g,calculated LOD of 0.10 ng/g,calculated limit of quantitation of 0.33 ng/g,and good correlation of 0.992.The recoveries were found in the range of 96.4%–103.7%with a relative standard deviation of 2.5%–3.6%for intra-and inter-assays.Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy.Furthermore,this strip test exhibited highly specific RAC detection without cross reactivity with related compounds.Therefore,the RAC–BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test.展开更多
The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated wo...The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated working conditions. However, the pump usually has to work in large-scale and time-variant working conditions. Therefore, the flow ripple characteristics of pump and analysis for its test accuracy with respect to variant steady-state conditions and transient conditions in a wide range of operating parameters are focused in this paper. First, a simulation model has been constructed, which takes the kinematics of oil film within friction pairs into account for higher accuracy. Afterwards, a test bed which adopts Secondary Source Method is built to verify the model. The simulation and tests results show that the angular position of the piston, corresponding to the position where the peak flow ripple is produced, varies with the different pressure. The pulsating amplitude and pulsation rate of flow ripple increase with the rise of pressure and the variation rate of pressure. For the pump working at a constant speed, the flow pulsation rate decreases dramatically with the increasing speed when the speed is less than 27.78% of the maximum speed, subsequently presents a small decrease tendency with the speed further increasing. With the rise of the variation rate of speed, the pulsating amplitude and pulsation rate of flow ripple increase. As the swash plate angle augments, the pulsating amplitude of flow ripple increases, nevertheless the flow pulsation rate decreases. In contrast with the effect of the variation of pressure, the test accuracy of flow ripple is more sensitive to the variation of speed. It makes the test accuracy above 96.20% available for the pulsating amplitude of pressure deviating within a range of ~6% from the mean pressure. However, with a variation of speed deviating within a range of ±2% from the mean speed, the attainable test accuracy of flow ripple is above 93.07%. The model constructed in this research proposes a method to determine the flow ripple characteristics of pump and its attainable test accuracy under the large-scale and time-variant working conditions. Meanwhile, a discussion about the variation of flow ripple and its obtainable test accuracy with the conditions of the pump working in wide operating ranges is given as well.展开更多
Against the background of the sand-flow foundation treatment engineering of Guangzhou Zhoutouzui variable cross-section immersed tunnel, a kind of sand deposit-detecting method was devised on the basis of full-scale m...Against the background of the sand-flow foundation treatment engineering of Guangzhou Zhoutouzui variable cross-section immersed tunnel, a kind of sand deposit-detecting method was devised on the basis of full-scale model test of sand-flow method. The real-time data of sand-deposit height and radius were obtained by the self-developed sand-deposit detectors. The test results show that the detecting method is simple and has high precision. In the use of sand-flow method, the sand-carrying capability of fluid is limited, and sand particles are all transported to the sand-deposit periphery through crater, gap and chutes after the sand deposit formed. The diffusion range of the particles outside the sand-deposit does not exceed 2.0 m. Severe sorting of sand particles is not observed because of the unique oblique-layered depositing process. The temporal and spatial distributions of gap and chutes directly affect the sand-deposit expansion, and the expansion trend of the average sand-deposit radius accords with quadratic time-history curve.展开更多
A more automated graphic user interface (GUI) test model, which is based on the event-flow graph, is proposed. In the model, a user interface automation API tool is first used to carry out reverse engineering for a GU...A more automated graphic user interface (GUI) test model, which is based on the event-flow graph, is proposed. In the model, a user interface automation API tool is first used to carry out reverse engineering for a GUI test sample so as to obtain the event-flow graph. Then two approaches are adopted to create GUI test sample cases. That is to say, an improved ant colony optimization (ACO) algorithm is employed to establish a sequence of testing cases in the course of the daily smoke test. The sequence goes through all object event points in the event-flow graph. On the other hand, the spanning tree obtained by deep breadth-first search (BFS) approach is utilized to obtain the testing cases from goal point to outset point in the course of the deep regression test. Finally, these cases are applied to test the new GUI. Moreover, according to the above-mentioned model, a corresponding prototype system based on Microsoft UI automation framework is developed, thus giving a more effective way to improve the GUI automation test in Windows OS.展开更多
The double blade pump is widely used in sewage treatment industry,however,the research on the internal flow characteristics of the double blade pump with particle image velocimetry(PIV) technology is very little at ...The double blade pump is widely used in sewage treatment industry,however,the research on the internal flow characteristics of the double blade pump with particle image velocimetry(PIV) technology is very little at present.To reveal inner flow characteristics in double blade pump impeller under off-design and design conditions,inner flows in a double blade pump impeller,whose specific speed is 111,are measured under the five off-design conditions and design condition by using 3D PIV test technology.In order to ensure the accuracy of the 3D PIV test,the external trigger synchronization system which makes use of fiber optic and equivalent calibration method are applied.The 3D PIV relative velocity synthesis procedure is compiled by using Visual C++ 2005.Then absolute velocity distribution and relative velocity distribution in the double blade pump impeller are obtained.Test results show that vortex exists in each condition,but the location,size and velocity of vortex core are different.Average absolute velocity value of impeller outlet increases at first,then decreases,and then increases again with increase of flow rate.Again average relative velocity values under 0.4,0.8,and 1.2 design condition are higher than that under 1.0 design condition,while under 0.6 and 1.4 design condition it is lower.Under low flow rate conditions,radial vectors of absolute velocities at impeller outlet and blade inlet near the pump shaft decrease with increase of flow rate,while that of relative velocities at the suction side near the pump shaft decreases.Radial vectors of absolute velocities and relative velocities change slightly under the two large flow rate conditions.The research results can be applied to instruct the hydraulic optimization design of double blade pumps.展开更多
Using the self-developed visualization test apparatus, centrifuge model tests at 20 g were carried out to research the macro and microscopic formation mechanism of coarse sand debris flows. The formation mode and soil...Using the self-developed visualization test apparatus, centrifuge model tests at 20 g were carried out to research the macro and microscopic formation mechanism of coarse sand debris flows. The formation mode and soil-water interaction mechanism of the debris flows were analyzed from both macroscopic and microscopic points of view respectively using high digital imaging equipment and micro-structure analysis software Geodip. The test results indicate that the forming process of debris flow mainly consists of three stages, namely the infiltration and softening stage, the overall slide stage, and debris flow stage. The essence of simulated coarse sand slope forming debris flow is that local fluidization cause slope to wholly slide. The movement of small particles forms a transient stagnant layer with increasing saturation, causing soil shear strength lost and local fluidization. When the driving force of the saturated soil exceeds the resisting force, debris flow happens on the coarse sand slope immediately.展开更多
Hot compression tests were conducted on a Gleeble-1500D thermal simulating tester. Based on the deformation behavior and microstructural evolution of superalloy GH4742, different types of instability criteria of Prasa...Hot compression tests were conducted on a Gleeble-1500D thermal simulating tester. Based on the deformation behavior and microstructural evolution of superalloy GH4742, different types of instability criteria of Prasad, Gegel, Malas, Murty and Semiatin were compared, and the physical significance of parameters was analyzed. Meanwhile, the processing maps with different instability criteria were obtained. It was shown that instability did not occur when average power dissipation rate was larger than 50% in the temperature range of 1020- 1130℃, corresponding to the strain rate range of 5 × 10-4-3.2 × 10-3 s-1. The domain is appropriate for the processing deformation of superalloy GH4742.展开更多
Nonlinear flow behavior of fluids through three-dimensional(3D)discrete fracture networks(DFNs)considering effects of fracture number,surface roughness and fracture aperture was experimentally and numerically investig...Nonlinear flow behavior of fluids through three-dimensional(3D)discrete fracture networks(DFNs)considering effects of fracture number,surface roughness and fracture aperture was experimentally and numerically investigated.Three physical models of DFNs were 3D-printed and then computed tomography(CT)-scanned to obtain the specific geometry of fractures.The validity of numerically simulating the fluid flow through DFNs was verified via comparison with flow tests on the 3D-printed models.A parametric study was then implemented to establish quantitative relations between the coefficients/parameters in Forchheimer’s law and geometrical parameters.The results showed that the 3D-printing technique can well reproduce the geometry of single fractures with less precision when preparing complex fracture networks,numerical modeling precision of which can be improved via CT-scanning as evidenced by the well fitted results between fluid flow tests and numerical simulations using CT-scanned digital models.Streamlines in DFNs become increasingly tortuous as the fracture number and roughness increase,resulting in stronger inertial effects and greater curvatures of hydraulic pressure-low rate relations,which can be well characterized by the Forchheimer’s law.The critical hydraulic gradient for the onset of nonlinear flow decreases with the increasing aperture,fracture number and roughness,following a power function.The increases in fracture aperture and number provide more paths for fluid flow,increasing both the viscous and inertial permeabilities.The value of the inertial permeability is approximately four orders of magnitude greater than the viscous permeability,following a power function with an exponent a of 3,and a proportional coefficient b mathematically correlated with the geometrical parameters.展开更多
A physical model test has been conducted to study the oil diffusion from the submarine pipeline under water flow.The crude oil in the flume is spilled from a leakage point of the pipeline and diffused from the seabed ...A physical model test has been conducted to study the oil diffusion from the submarine pipeline under water flow.The crude oil in the flume is spilled from a leakage point of the pipeline and diffused from the seabed to the surface. By the non-contact optical measuring technology, an image acquisition and data analysis system is designed to explore the spilled mechanism and characteristic. The oil trajectory, velocity and the rising time to the surface are obtained through this system. The influence of the water flow and the spilled discharge on the behavior of the spilled oil are analyzed from both qualitative and quantitative perspectives. The sensitivity study of the characteristic physical quantities to various factors are presented afterward. The spilled oil under water is mainly distributed in the form of the scattered particles with different sizes. The rising process of the oil can be divided into three stages: full, dispersion and aggregation period. The spilled discharge is the primary factor affecting the rising time of the oil particles. In the rising process of the oil particles, the vertical velocity of the oil is mainly affected by the spilled discharge, and the transverse velocity is more dependent on the water velocity. The deviation of the transverse oil velocity is much larger than that of the rising time and the vertical oil velocity. The study can provide a theoretical reference for the prediction system of oil spill emergency.展开更多
Three tracing tests from the same injection point executed at low, medium, and high water levels in the karst aquifer near Tianshengan village, Lunan Stone Forest, Yunnan Province, China, have revealed the basic prope...Three tracing tests from the same injection point executed at low, medium, and high water levels in the karst aquifer near Tianshengan village, Lunan Stone Forest, Yunnan Province, China, have revealed the basic properties of underground water flow. They showed the general directions of water flows; tracer concentrations were observed at six successive points allowing for the calculation of apparent dominant flow velocities at these sections towards the Dalongtan karst spring. For the high water level, the discharge between single sections was between two and 10 times greater than that at low water level. For the medium water level, the flow velocity at different sections was between 1.4 and 3.7 times faster than that at low water level; and for high water level, it was between 1.3 and 2.7 times faster than that at medium water level. The fastest water flow appeared at the first section (23 cm/s at medium water level); and the slowest (0.6 cm/s at low water level) appeared where water flow must cross the Tianshengan fault (north-south direction), and later, a layer of 20-30 m thickness of quartz sandstone and shale clay-stones. It was also possible to calculate the recovery of the tracer for point 4, Dakenyan, where discharge was measured. At the medium water level, 50% of the injected tracer was detected a half-day after its first appearance and at low water level after more than 3 days. The previously published research illustrates the transport velocities of possible contaminants and their solubilities in water at different hydrological conditions.展开更多
文摘A test flow description language is designed for the description of test flow.The design concept,composition,program structure and syntax structure of statement are presented.The development and impletementation processes of the language are also described.This language is independent of hardware,which can be used for different platforms,and can be extended.The language is used to describe the test flow easily.It simplifies the development process of test software and reduces the difficulty of software maintenance greatly.
基金Project Project supported by the Thailand Research Fund through the International Research Network(No.PHD58W0001)the Thailand Research Fund through Research Team Promotion Grant the Ratchadaphisaksomphot Endowment Fund of Chulalongkorn University(No.RTA6080002),Thailand
文摘In this work,a novel conjugate of ractopamine and bovine serum albumin(RAC–BSA)has been developed via the Mannich reaction,with a mole coupling ratio for RAC–BSA of 9:1.The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays.RAC–BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed.For sample preparation,RAC was spiked in swine feed purchased from the local markets in Thailand,and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer.The procedures for sample preparation were completed within 25 min.Under optimal conditions,the limit of detection(LOD),assessed by the naked eye within 5 min,was found to be 1 ng/g.A semi-quantitative analysis was also conducted using a smart phone and computer software,with a linearity of 0.075–0.750 ng/g,calculated LOD of 0.10 ng/g,calculated limit of quantitation of 0.33 ng/g,and good correlation of 0.992.The recoveries were found in the range of 96.4%–103.7%with a relative standard deviation of 2.5%–3.6%for intra-and inter-assays.Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy.Furthermore,this strip test exhibited highly specific RAC detection without cross reactivity with related compounds.Therefore,the RAC–BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test.
基金Supported by National Basic Research Program of China(973 Program,Grant No.2014CB046403)National Key Technology R&D Program of the Twelfth Five-year Plan of China(Grant No.2013BAF07B01)
文摘The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated working conditions. However, the pump usually has to work in large-scale and time-variant working conditions. Therefore, the flow ripple characteristics of pump and analysis for its test accuracy with respect to variant steady-state conditions and transient conditions in a wide range of operating parameters are focused in this paper. First, a simulation model has been constructed, which takes the kinematics of oil film within friction pairs into account for higher accuracy. Afterwards, a test bed which adopts Secondary Source Method is built to verify the model. The simulation and tests results show that the angular position of the piston, corresponding to the position where the peak flow ripple is produced, varies with the different pressure. The pulsating amplitude and pulsation rate of flow ripple increase with the rise of pressure and the variation rate of pressure. For the pump working at a constant speed, the flow pulsation rate decreases dramatically with the increasing speed when the speed is less than 27.78% of the maximum speed, subsequently presents a small decrease tendency with the speed further increasing. With the rise of the variation rate of speed, the pulsating amplitude and pulsation rate of flow ripple increase. As the swash plate angle augments, the pulsating amplitude of flow ripple increases, nevertheless the flow pulsation rate decreases. In contrast with the effect of the variation of pressure, the test accuracy of flow ripple is more sensitive to the variation of speed. It makes the test accuracy above 96.20% available for the pulsating amplitude of pressure deviating within a range of ~6% from the mean pressure. However, with a variation of speed deviating within a range of ±2% from the mean speed, the attainable test accuracy of flow ripple is above 93.07%. The model constructed in this research proposes a method to determine the flow ripple characteristics of pump and its attainable test accuracy under the large-scale and time-variant working conditions. Meanwhile, a discussion about the variation of flow ripple and its obtainable test accuracy with the conditions of the pump working in wide operating ranges is given as well.
基金Project(51108190) supported by the National Natural Science Foundation of ChinaProject(2012ZC27) supported by the Independence Research Subject from State Key Laboratory of Subtropical Building Science,ChinaProject(GTCC 2008-253) supported by the Research Subject from Guangzhou City,China
文摘Against the background of the sand-flow foundation treatment engineering of Guangzhou Zhoutouzui variable cross-section immersed tunnel, a kind of sand deposit-detecting method was devised on the basis of full-scale model test of sand-flow method. The real-time data of sand-deposit height and radius were obtained by the self-developed sand-deposit detectors. The test results show that the detecting method is simple and has high precision. In the use of sand-flow method, the sand-carrying capability of fluid is limited, and sand particles are all transported to the sand-deposit periphery through crater, gap and chutes after the sand deposit formed. The diffusion range of the particles outside the sand-deposit does not exceed 2.0 m. Severe sorting of sand particles is not observed because of the unique oblique-layered depositing process. The temporal and spatial distributions of gap and chutes directly affect the sand-deposit expansion, and the expansion trend of the average sand-deposit radius accords with quadratic time-history curve.
文摘A more automated graphic user interface (GUI) test model, which is based on the event-flow graph, is proposed. In the model, a user interface automation API tool is first used to carry out reverse engineering for a GUI test sample so as to obtain the event-flow graph. Then two approaches are adopted to create GUI test sample cases. That is to say, an improved ant colony optimization (ACO) algorithm is employed to establish a sequence of testing cases in the course of the daily smoke test. The sequence goes through all object event points in the event-flow graph. On the other hand, the spanning tree obtained by deep breadth-first search (BFS) approach is utilized to obtain the testing cases from goal point to outset point in the course of the deep regression test. Finally, these cases are applied to test the new GUI. Moreover, according to the above-mentioned model, a corresponding prototype system based on Microsoft UI automation framework is developed, thus giving a more effective way to improve the GUI automation test in Windows OS.
基金supported by National Outstanding Young Scientists Founds of China (Grant No. 50825902)National Key Technology R&D Program of China (Grant No. 2008BAF34B15)+2 种基金National Natural Science Foundation of China (Grant No. 51079062)Jiangsu Provincial 333 High-level Personal Training Project of ChinaJiangsu Provincial Six Talent Peak of China
文摘The double blade pump is widely used in sewage treatment industry,however,the research on the internal flow characteristics of the double blade pump with particle image velocimetry(PIV) technology is very little at present.To reveal inner flow characteristics in double blade pump impeller under off-design and design conditions,inner flows in a double blade pump impeller,whose specific speed is 111,are measured under the five off-design conditions and design condition by using 3D PIV test technology.In order to ensure the accuracy of the 3D PIV test,the external trigger synchronization system which makes use of fiber optic and equivalent calibration method are applied.The 3D PIV relative velocity synthesis procedure is compiled by using Visual C++ 2005.Then absolute velocity distribution and relative velocity distribution in the double blade pump impeller are obtained.Test results show that vortex exists in each condition,but the location,size and velocity of vortex core are different.Average absolute velocity value of impeller outlet increases at first,then decreases,and then increases again with increase of flow rate.Again average relative velocity values under 0.4,0.8,and 1.2 design condition are higher than that under 1.0 design condition,while under 0.6 and 1.4 design condition it is lower.Under low flow rate conditions,radial vectors of absolute velocities at impeller outlet and blade inlet near the pump shaft decrease with increase of flow rate,while that of relative velocities at the suction side near the pump shaft decreases.Radial vectors of absolute velocities and relative velocities change slightly under the two large flow rate conditions.The research results can be applied to instruct the hydraulic optimization design of double blade pumps.
基金Funded by National Natural Science Foundation of China(Grant No.41272296)
文摘Using the self-developed visualization test apparatus, centrifuge model tests at 20 g were carried out to research the macro and microscopic formation mechanism of coarse sand debris flows. The formation mode and soil-water interaction mechanism of the debris flows were analyzed from both macroscopic and microscopic points of view respectively using high digital imaging equipment and micro-structure analysis software Geodip. The test results indicate that the forming process of debris flow mainly consists of three stages, namely the infiltration and softening stage, the overall slide stage, and debris flow stage. The essence of simulated coarse sand slope forming debris flow is that local fluidization cause slope to wholly slide. The movement of small particles forms a transient stagnant layer with increasing saturation, causing soil shear strength lost and local fluidization. When the driving force of the saturated soil exceeds the resisting force, debris flow happens on the coarse sand slope immediately.
基金supported by the National Key Basic Research Program of China (No. 2010CB631203)
文摘Hot compression tests were conducted on a Gleeble-1500D thermal simulating tester. Based on the deformation behavior and microstructural evolution of superalloy GH4742, different types of instability criteria of Prasad, Gegel, Malas, Murty and Semiatin were compared, and the physical significance of parameters was analyzed. Meanwhile, the processing maps with different instability criteria were obtained. It was shown that instability did not occur when average power dissipation rate was larger than 50% in the temperature range of 1020- 1130℃, corresponding to the strain rate range of 5 × 10-4-3.2 × 10-3 s-1. The domain is appropriate for the processing deformation of superalloy GH4742.
基金the Natural Science Foundation of Zhejiang Province(Grant No.LR19E090001)the Natural Science Foundation of China(Grant Nos.42077252,42011530122,and 51979272).
文摘Nonlinear flow behavior of fluids through three-dimensional(3D)discrete fracture networks(DFNs)considering effects of fracture number,surface roughness and fracture aperture was experimentally and numerically investigated.Three physical models of DFNs were 3D-printed and then computed tomography(CT)-scanned to obtain the specific geometry of fractures.The validity of numerically simulating the fluid flow through DFNs was verified via comparison with flow tests on the 3D-printed models.A parametric study was then implemented to establish quantitative relations between the coefficients/parameters in Forchheimer’s law and geometrical parameters.The results showed that the 3D-printing technique can well reproduce the geometry of single fractures with less precision when preparing complex fracture networks,numerical modeling precision of which can be improved via CT-scanning as evidenced by the well fitted results between fluid flow tests and numerical simulations using CT-scanned digital models.Streamlines in DFNs become increasingly tortuous as the fracture number and roughness increase,resulting in stronger inertial effects and greater curvatures of hydraulic pressure-low rate relations,which can be well characterized by the Forchheimer’s law.The critical hydraulic gradient for the onset of nonlinear flow decreases with the increasing aperture,fracture number and roughness,following a power function.The increases in fracture aperture and number provide more paths for fluid flow,increasing both the viscous and inertial permeabilities.The value of the inertial permeability is approximately four orders of magnitude greater than the viscous permeability,following a power function with an exponent a of 3,and a proportional coefficient b mathematically correlated with the geometrical parameters.
基金The National Natural Science Foundation of China under contract No.51609168the Science and Technology Program of CNOOC Limited under contract No.YXKY-2016-2Y-07+2 种基金the Open Fund of State Key Laboratory of Coastal and Offshore Engineering under contract No.LP1608the National Basic Research Program(973 Program)of China under contract No.2014CB046804the National Science and Technology Major Project under contract No.2016ZX05057020
文摘A physical model test has been conducted to study the oil diffusion from the submarine pipeline under water flow.The crude oil in the flume is spilled from a leakage point of the pipeline and diffused from the seabed to the surface. By the non-contact optical measuring technology, an image acquisition and data analysis system is designed to explore the spilled mechanism and characteristic. The oil trajectory, velocity and the rising time to the surface are obtained through this system. The influence of the water flow and the spilled discharge on the behavior of the spilled oil are analyzed from both qualitative and quantitative perspectives. The sensitivity study of the characteristic physical quantities to various factors are presented afterward. The spilled oil under water is mainly distributed in the form of the scattered particles with different sizes. The rising process of the oil can be divided into three stages: full, dispersion and aggregation period. The spilled discharge is the primary factor affecting the rising time of the oil particles. In the rising process of the oil particles, the vertical velocity of the oil is mainly affected by the spilled discharge, and the transverse velocity is more dependent on the water velocity. The deviation of the transverse oil velocity is much larger than that of the rising time and the vertical oil velocity. The study can provide a theoretical reference for the prediction system of oil spill emergency.
文摘Three tracing tests from the same injection point executed at low, medium, and high water levels in the karst aquifer near Tianshengan village, Lunan Stone Forest, Yunnan Province, China, have revealed the basic properties of underground water flow. They showed the general directions of water flows; tracer concentrations were observed at six successive points allowing for the calculation of apparent dominant flow velocities at these sections towards the Dalongtan karst spring. For the high water level, the discharge between single sections was between two and 10 times greater than that at low water level. For the medium water level, the flow velocity at different sections was between 1.4 and 3.7 times faster than that at low water level; and for high water level, it was between 1.3 and 2.7 times faster than that at medium water level. The fastest water flow appeared at the first section (23 cm/s at medium water level); and the slowest (0.6 cm/s at low water level) appeared where water flow must cross the Tianshengan fault (north-south direction), and later, a layer of 20-30 m thickness of quartz sandstone and shale clay-stones. It was also possible to calculate the recovery of the tracer for point 4, Dakenyan, where discharge was measured. At the medium water level, 50% of the injected tracer was detected a half-day after its first appearance and at low water level after more than 3 days. The previously published research illustrates the transport velocities of possible contaminants and their solubilities in water at different hydrological conditions.