期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Study on the Real Time pH Measurement System Using for Wireless Technology
1
作者 Jun-Jie Feng Jung-Chuan Chou +1 位作者 Tai-Ping Sun Shen-Kan Hsiung 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期244-245,共2页
The application of Bluetooth on the pH sensor was accomplished.Based on the experimental results,Bluetooth technology was used to measure pH values without limiting the distance.Moreover,Biuetooth technology provides ... The application of Bluetooth on the pH sensor was accomplished.Based on the experimental results,Bluetooth technology was used to measure pH values without limiting the distance.Moreover,Biuetooth technology provides low power, low cost and small volume,therefore,it can increase the practicability of the system.In this investigation,the pH value was detected by the SnO_2/ITO glass-based pH sensor.During the signal progress,the detected signal was transferred to the microchip PIC18.After that,the microchip was able to communicate with PC by the Bluetooth.Moreover,the microchip can diagnose the sensing signal and sends the warning signal by alert function.In addition,the part of PC has the ability to record the information,builds the database for analyzing the pH values,and provides a better long-distance monitoring system. 展开更多
关键词 bluetooth technology sno2/ito glass-based ph sensor MICROCHIP monitoring system
在线阅读 下载PDF
Calibration of the Circuit Measurement for the Glucose Sensor
2
作者 Jung-Chuan Chou Sung-Chih Chen 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期337-338,共2页
The extended gate field effect transistor (EGFET)has many advantages such as the fabrication is easy,low cost, easy to operate etc.The EGFET was applied to biosensor in recent years.In this study,the tin oxide (SnO_2)... The extended gate field effect transistor (EGFET)has many advantages such as the fabrication is easy,low cost, easy to operate etc.The EGFET was applied to biosensor in recent years.In this study,the tin oxide (SnO_2)pH sensitive membrane was deposited on ITO glass,when the surface voltage which pH membrane changes,the gate voltage and current channel of MOSFET will change immediately to detect concentration of the glucose sensor.In this study we have devoted to research about the calibration of the circuit measurement for the glucose sensor,and study the calibration system of the drift and hysteresis. 展开更多
关键词 glucose sensor extended gate field effect transistor(EGFET) sno2/ito glass DRIFT HYSTERESIS
在线阅读 下载PDF
Extended Gate Field Effect Transistor Based Measuring of the Vitamin C content of Orange Juice
3
作者 Jung-Chuan Chou 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期342-343,共2页
An extended-gate field effect transistor (EGFET)of SnO_2/ITO glass was applied to manufacture the vitamin C sensor.Therefore,we immobilized the ascorbate oxidase with 3-glycidoxypropyltrimethoxysilane (GPTS)method to ... An extended-gate field effect transistor (EGFET)of SnO_2/ITO glass was applied to manufacture the vitamin C sensor.Therefore,we immobilized the ascorbate oxidase with 3-glycidoxypropyltrimethoxysilane (GPTS)method to measure the different concentrations of the vitamin C solution in an optimum measurement environment.In order to find the best measurement conditions of the biosensor,we studied the vitamin C sensor in different pH values of the phosphate buffer solution (PBS).Additionally,we used experimental results to discuss the response time and response voltage to compare vitamin C with orange juice for the vitamin C sensor. 展开更多
关键词 orange juice extended-gate field effect transistor sno2/ito glass vitamin C sensor
暂未订购
上一页 1 下一页 到第