Transmission tower-line systems(TTLSs)play a crucial role in the long-distance transmission of electrical energy,often necessitating their crossing through active fault areas.However,previous studies have given limite...Transmission tower-line systems(TTLSs)play a crucial role in the long-distance transmission of electrical energy,often necessitating their crossing through active fault areas.However,previous studies have given limited attention to the seismic performance of fault-crossing transmission TTLSs,particularly in terms of considering the impact of permanent ground motion displacements(PGMDs).This study attempts to address this concern by evaluating the seismic performance of TTLSs exposed to fault earthquakes.Three strike-slip ground motions are carefully selected,and the corresponding PGMDs are accurately replicated through baseline adjustment.A meticulously designed and fabricated reduced-scale experimental model of a TTLS is then employed to investigate the influence of the fault crossing location(FCL)on its seismic performance.The shake table tests conducted unequivocally demonstrate that PGMDs significantly amplify the seismic responses of the TTLS and identify the most unfavorable FCL.Furthermore,a finite element model(FEM)is developed and its accuracy is validated by comparing it with the experimental results.Parametric analyses are conducted to explore the effects of fault crossing angles(FCAs)and PGMD amplitudes on the seismic performances of TTLSs.This study is expected to contribute valuable insights for the seismic design and performance analysis of TTLSs crossing fault areas.展开更多
To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Tab...To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Table(NEST)has been developed.The testbed consists of three consecutive floors of steel structure.The bottom two floors provide a space to accommodate a full-scale room.To fully explore the flexibility of NEST,we propose a novel control strategy to generate the required shake table input time histories for the testbed to track the target floor motions of the buildings of interest with high accuracy.The control strategy contains two parts:an inverse dynamic compensation via simulation of feedback control systems(IDCS)algorithm and an offline iteration procedure based on a refined nonlinear numerical model of the testbed.The key aspects of the control strategy were introduced in this paper.Experimental tests were conducted to simulate the seismic responses of a full-scale office room on the 21^(st)floor of a 42-story high-rise building.The test results show that the proposed control strategy can reproduce the target floor motions of the building of interest with less than 20%errors within the specified frequency range.展开更多
Severe damage to suspended ceilings of metal grids and lay-in panels was observed in public buildings during the 2013 M7.0 Lushan earthquake in China. Over the past several years, suspended ceilings have been widely u...Severe damage to suspended ceilings of metal grids and lay-in panels was observed in public buildings during the 2013 M7.0 Lushan earthquake in China. Over the past several years, suspended ceilings have been widely used practice in public buildings throughout China, including government offices, schools and hospitals. To investigate the damage mechanism of suspended ceilings, a series of three-dimensional shake table tests was conducted to reproduce the observed damage. A full-scale reinforced concrete frame was constructed as the testing frame for the ceiling, which was single-story and infilled with brick masonry walls to represent the local construction of low-rise buildings. In general, the ceiling in the tests exhibited similar damage phenomena as the field observations, such as higher vulnerability of perimeter elements and extensive damage to the cross runners. However, it exhibited lower fragility in terms of peak ground/roof accelerations at the initiation of damage. Further investigations are needed to clarify the reasons for this behavior.展开更多
This paper describes a shake table test study on the seismic response of low-cap pile groups and a bridge structure in liquefiable ground. The soil profile, contained in a large-scale laminar shear box, consisted of a...This paper describes a shake table test study on the seismic response of low-cap pile groups and a bridge structure in liquefiable ground. The soil profile, contained in a large-scale laminar shear box, consisted of a horizontally saturated sand layer overlaid with a silty clay layer, with the simulated low-cap pile groups embedded. The container was excited in three E1 Centro earthquake events of different levels. Test results indicate that excessive pore pressure (EPP) during slight shaking only slightly accumulated, and the accumulation mainly occurred during strong shaking. The EPP was gradually enhanced as the amplitude and duration of the input acceleration increased. The acceleration response of the sand was remarkably influenced by soil liquefaction. As soil liquefaction occurred, the peak sand displacement gradually lagged behind the input acceleration; meanwhile, the sand displacement exhibited an increasing effect on the bending moment of the pile, and acceleration responses of the pile and the sand layer gradually changed from decreasing to increasing in the vertical direction from the bottom to the top. A jump variation of the bending moment on the pile was observed near the soil interface in all three input earthquake events. It is thought that the shake table tests could provide the groundwork for further seismic performance studies of low-cap pile groups used in bridges located on liquefiable groun.展开更多
Bridges are a part of vital infrastructure,which should operate even after a disaster to keep emergency services running.There have been numerous bridge failures during major past earthquakes due to liquefaction.Among...Bridges are a part of vital infrastructure,which should operate even after a disaster to keep emergency services running.There have been numerous bridge failures during major past earthquakes due to liquefaction.Among other categories of failures,mid span collapse(without the failure of abutments)of pile supported bridges founded in liquefiable deposits are still observed even in most recent earthquakes.This mechanism of collapse is attributed to the effects related to the differential elongation of natural period of the individual piers during liquefaction.A shake table investigation has been carried out in this study to verify mechanisms behind midspan collapse of pile supported bridges in liquefiable deposits.In this investigation,a typical pile supported bridge is scaled down,and its foundations pass through the liquefiable loose sandy soil and rest in a dense gravel layer.White noise motions of increasing acceleration magnitude have been applied to initiate progressive liquefaction and to characterize the dynamic features of the bridge.It has been found that as the liquefaction of the soil sets in,the natural frequency of individual bridge support is reduced,with the highest reduction occurring near the central spans.As a result,there is differential lateral displacement and bending moment demand on the piles.It has also been observed that for the central pile,the maximum bending moment in the pile will occur at a higher elevation,as compared to that of the interface of soils of varied stiffness,unlike the abutment piles.The practical implications of this research are also highlighted.展开更多
Many single-tower reinforced concrete core wall-steel frame (RCC-SF) buildings have been built in China, but there are no buildings of different-height multi-tower hybrid system. A multi-tower RCC-SF tall building w...Many single-tower reinforced concrete core wall-steel frame (RCC-SF) buildings have been built in China, but there are no buildings of different-height multi-tower hybrid system. A multi-tower RCC-SF tall building was thus studied because of its structural complexity and irregularity. First, a 1/15 scaled model structure was designed and tested on the shake table under minor, moderate, and major earthquake levels. Then, the dynamic responses of the model structure were interpreted to those of the prototype structure according to the similitude theory. Experimental results demonstrate that, despite the complexity of the structure, the lateral deformation bends as the "bending type" and the RC core walls contribute more than the steel frames to resist seismic loads. The maximum inter-story drift of the complex building under minor earthquakes is slightly beyond the elastic limitation specified in the Chinese code, and meets code requirements under major earthquakes. From the test results some suggestions are provided that could contribute favorable effect on the seismic behavior and the displacement of the building.展开更多
As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years...As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years.To fulfill this special requirement imposed by current seismic design codes,reinforcement ratios in the bridge towers have to be kept significantly higher than if limited ductility behavior of the tower is allowed.In addition,since the foundation capacity is closely related to the moment and shear capacities of the bridge tower,a large increase in bridge construction cost for elastically designed cable-stayed bridge is inevitable.To further investigate the possibility of limited ductility bridge tower design strategies,a new 1/20-scale cable-stayed bridge model with H-shaped bridge towers designed according to strong strut-weak tower column design was tested.The shake table experimental results are compared with a previous strong tower column-weak strut designed full bridge model.A comparison of the results show that ductility design with plastic hinges located on tower columns,i.e.,strong strut-weak tower column design,is another effective seismic design strategy that results in only small residual displacement at the top of the tower column,even under very severe earthquake excitations.展开更多
To improve the efficiency and amplify the exciting force of a shake table,a novel variable stiffness mechanism(VSM)constructed by four leaf spring-lever combinations(LSLCs)was designed.Three VSMs were installed in par...To improve the efficiency and amplify the exciting force of a shake table,a novel variable stiffness mechanism(VSM)constructed by four leaf spring-lever combinations(LSLCs)was designed.Three VSMs were installed in parallel on the traditional hydraulic shake table to constitute a resonant shake table(RST).The static model of the VSM and the dynamic model of the RST were constructed by considering the large deflection of leaf springs and the geometrical nonlinearity of L-shaped levers.The variable stiffness property of LSLCs was analyzed and verified through static experiments.The simulation and vibration experiments on the dynamic properties of the RST prototype were conducted.The results show that compared with traditional shake tables,the RST consumes lower exciting force in a specified frequency bandwidth when outputting the same displacement of vibration.Under a harmonic vibrational excitation,the RST is effective for vibration enhancement using broadband frequency resonance and can save energy to some extent.The broadband resonance technology exhibits considerable potential in practical engineering applications.展开更多
In this study, shaking table tests were performed to investigate the dynamic characteristics of a mold transformer. Based on the test results, rotary friction dampers were developed to mitigate the excessive lateral d...In this study, shaking table tests were performed to investigate the dynamic characteristics of a mold transformer. Based on the test results, rotary friction dampers were developed to mitigate the excessive lateral displacement that occurred along the direction of the weak stiffness axis of the mold transformer. In addition, shaking table tests were performed by attaching friction dampers to both sides of the mold transformer. Based on the shaking table test results, the natural frequency, mode vector, and damping ratio of the mold transformer were derived using the transfer function and half-power bandwidth. The test results indicated that the use of friction dampers can decrease the displacement and acceleration response of the mold transformer. Finally, dynamic structural models were established considering the component connectivity and mass distribution of the mold transformer. In addition, a numerical strategy was proposed to calibrate the stiffness coefficients of the mold transformer, thereby facilitating the relationship between generalized mass and stiffness. The results indicated that the analytical model based on the calibration strategy of stiffness coefficients can reasonably simulate the dynamic behavior of the mold transformer using friction dampers with regard to transfer function, displacement, and acceleration response.展开更多
Weak interlayers play a crucial role in the seismic performance of bedding slopes;however,the effects of structural surface development within these layers remain underexplored.This study presents two scaled models of...Weak interlayers play a crucial role in the seismic performance of bedding slopes;however,the effects of structural surface development within these layers remain underexplored.This study presents two scaled models of bedding slopes,each with different weak interlayers:one with a homogeneous weak layer and another with discontinuous interfaces.Shaking table tests were conducted to compare their seismic performance.The results show that the peak ground acceleration(PGA)values above the weak interlayer in model A were significantly higher than those in model B,with the differences increasing as the input wave amplitude increased.The peak earth pressure(PEP)values at the tensile failure boundary at the rear edge of model A were also higher,whereas those within the weak layer at the toe of model A were lower than those in model B.Deformation analysis revealed that the maximum principal strain in model A initially appeared at the upper part of the tensile failure boundary,while the maximum shear strain was concentrated near the rear edge within the weak layer.In contrast,model B exhibited the opposite strain distribution.These findings provide insight into the impact of weak interlayers on the dynamic response and deformation of bedding slopes,highlighting the importance of considering this factor in seismic landslide investigations and failure mode predictions.展开更多
Seismic-induced landslides critically threaten infrastructure and human safety,especially in sandy slopes where conventional stabilization methods often fail under dynamic loading.This study evaluates circular open-en...Seismic-induced landslides critically threaten infrastructure and human safety,especially in sandy slopes where conventional stabilization methods often fail under dynamic loading.This study evaluates circular open-ended anti-slide pipe piles embedded in a two-layer sandy slope with differing geotechnical properties.Ten physical models,including five freefield and five pile-reinforced slopes,were tested on a shaking table.Key seismic responses—acceleration,soil displacement,and bending moments—were monitored using accelerometers,strain gauges,and Digital Image Correlation(DIC).Complementary numerical simulations using Abaqus with a Mohr–Coulomb model validated experimental results.Soil displacement in free-field models under 0.25g shaking was about 3.5 times greater than in reinforced slopes.Bending moments increased with seismic intensity,peaking at depths around five times the pile diameter.Limitations including simplified two-layer soil representation,idealized seismic inputs,and boundary effects inherent to laboratory models restrict direct field application but enable controlled analysis.By combining physical experiments with numerical modeling,the study provides a robust and validated framework for seismic slope stabilization.This integrated approach enhances understanding of soil–pile interaction under seismic loads and offers targeted insights for developing safer and more reliable geotechnical design strategies in earthquake-prone areas.展开更多
A fault is a geological structure characterized by significant displacement of rock masses along a fault plane within the Earth's crust.The Yunnan Tabaiyi Tunnel intersects multiple fault zones,making tunnel const...A fault is a geological structure characterized by significant displacement of rock masses along a fault plane within the Earth's crust.The Yunnan Tabaiyi Tunnel intersects multiple fault zones,making tunnel construction in fault-prone areas particularly vulnerable to the effects of fault activity due to the complexities of the surrounding geological environment.To investigate the dynamic response characteristics of tunnel structures under varying surrounding rock conditions,a three-dimensional large-scale shaking table physical model test was conducted.This study also aimed to explore the damage mechanisms associated with the Tabaiyi Tunnel under seismic loading.The results demonstrate that poor quality surrounding rock enhances the seismic response of the tunnel.This effect is primarily attributed to the distribution characteristics of acceleration,dynamic strain,and dynamic soil pressure.A comparison between unidirectional and multi-directional(including vertical)seismic motions reveals that vertical seismic motion has a more significant impact on specific tunnel locations.Specifically,the maximum tensile stress is observed at the arch shoulder,with values ranging from 60 to 100 k Pa.Moreover,NPR(Non-Prestressed Reinforced)anchor cables exhibit a substantial constant resistance effect under low-amplitude seismic waves.However,when the input earthquake amplitude reaches 0.8g,local sliding occurs at the arch shoulder region of the NPR anchor cable.These findings underscore the importance of focusing on seismic mitigation measures in fault zones and reinforcing critical areas,such as the arch shoulders,in practical engineering applications.展开更多
Shaking table tests are widely used to evaluate seismic effects on railway structures,but accurately measuring rail displacement remains a significant challenge owing to the nonlinear characteristics of large displace...Shaking table tests are widely used to evaluate seismic effects on railway structures,but accurately measuring rail displacement remains a significant challenge owing to the nonlinear characteristics of large displacements,ambient noise interference,and limitations in displacement meter installation.In this paper,a novel method that integrates the Kanade-Lucas-Tomasi(KLT)feature tracker with an extended Kalman filter(EKF)is presented for measuring rail displacement during shaking table tests.The method employs KLT feature tracker and a random sample consensus algorithm to extract and track key feature points,while EKF optimally estimates dynamic states by accounting for system noise and observation errors.Shaking table test results demonstrate that the proposed method achieves an acceleration root mean square error of 0.300 m/s^(2)and a correlation with accelerometer data exceeding 99.7%,significantly outper-forming the original KLT approach.This innovative method provides a more efficient and reliable solution for measuring rail displacement under large nonlinear vibrations.展开更多
The relative stiffness between underground structures and surrounding soil may significantly influence the dynamic response of such structures.In this study,two underground pipelines were fabricated using rubber joint...The relative stiffness between underground structures and surrounding soil may significantly influence the dynamic response of such structures.In this study,two underground pipelines were fabricated using rubber joints with varying stiffness,and the corresponding dynamic response was evaluated.Model soils were prepared based on similarity ratios.Next,reduced-scale shaking table tests were conducted to investigate the impact of circular underground structures with varying stiffness joints on the amplification of ground acceleration,dynamic response,and deformation patterns of the underground pipelines.The comparative analysis showed that structures with lower stiffness exert less constraint on the surrounding soil,resulting in a higher amplification factor of ground acceleration.The seismic response of less stiff structures is generally 1.1 to 1.3 times the response of the stiffer structures.Therefore,the seismic response of the variable stiffness pipeline exhibits pronounced characteristics.Rubber joints effectively reduce the seismic response of underground structures,demonstrating favorable isolation effects.Consequently,relative stiffness plays a crucial role in the seismic design of underground structures,and the use of rubber materials in underground structures is advantageous.展开更多
Seismic isolation systems designed for extreme events may likely experience low to moderate earthquakes during the design life of the structure rather than the extreme event itself.In new seismic building design codes...Seismic isolation systems designed for extreme events may likely experience low to moderate earthquakes during the design life of the structure rather than the extreme event itself.In new seismic building design codes, low and moderate earthquakes are also mandatory to be investigated in Turkey and some other countries. One of the main reasons is to protect the integrity of non-structural elements or machines during these types of earthquakes. The selection of appropriate seismic isolation is typically decided based on their forcedisplacement characteristics and amount of energy dissipation per cycle. The same energy dissipation per cycle(EDC) can be achieved by high force-low displacement or low force-high displacement response. The focus of this research is given to identify the performance of ball rubber bearing isolation systems compared to different or similar EDC units such as elastomeric bearings and lead rubber bearings through a series of shake table tests performed at low to moderate earthquake levels. Shake table tests were conducted on an almost full scale short span bridge. The tests have revealed that the ball rubber bearings are superior to elastomeric bearings in terms of EDC and can match EDC of LRB. However, although LRB and BRB have the same EDC, BRB is more beneficial to use under low to moderate earthquakes since BRB can transmit less force with larger displacement compared to LRB and LRB can sometimes stay in elastic range with an ineffective EDC as a stiffer elastomeric bearing.展开更多
As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scal...As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.展开更多
The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The ma...The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The macro phenomena of the two different foundation models are described and analyzed.The effects of the replacement of EPS composite soil on seismic-induced liquefaction of backfill and the dynamic performance of a caisson structure are evaluated in detail.The results show that the excess pore water pressure generation in the CES is significantly slower than that in the CSS during the shaking.The dynamic earth pressure acting on the caisson has a triangular shape.The response of horizontal acceleration,displacement,settlement,and rotation angle of the caisson in the CES is smaller than that in the CSS,which means the caisson in the CES has a better seismic performance.Furthermore,the out-of-phase phenomenon between dynamic earth thrust and inertial force in the CES is more obvious than that in the CSS,which is beneficial to reduce the lateral force and improve the stability of the caisson structure.展开更多
When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response...When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response of underground structures in liquefiable interlayer sites,and a valid numerical model was obtained through simulation model test.Finally,the calibrated numerical model was used to perform further research on the influence of various distribution characteristics of liquefiable interlayers on the seismic reaction of underground structures.The key findings are as follows.The structure faces the most unfavorable condition once a liquefiable layer is located in the middle of the underground structure.When a liquefiable layer exists in the middle of the structure,the seismic reactions of both the underground structure and model site will increase with the rise of the thickness of the liquefiable interlayer.The inter-story drift of the structure in the non-liquefiable site is much smaller than that in the liquefiable interlayer site.The inter-story drift of the structure is not only associated with the site displacement and the soil-structure stiffness ratio but also closely associated with the slippage of the soil-structure contact interface under the condition of large deformation of the site.展开更多
The present study investigates the influence of embedment depth of isolated footing supporting moment-resisting frame buildings through scaled-down tests.These experiments utilize scaled models representing different ...The present study investigates the influence of embedment depth of isolated footing supporting moment-resisting frame buildings through scaled-down tests.These experiments utilize scaled models representing different building aspect ratios and footing embedment depths.All the model tests are subjected to scaled-down input ground motions of different intensities and magnitudes.These model tests are performed in laminar shear containers through shake table testing.The results obtained for different cases of soil-foundation-structure systems and fixed-base conditions are expressed in terms of natural frequency,peak spectral acceleration,frequency response,lateral deformation,inter-storey drifts,and rocking of the foundation.The analysis reveals that the natural frequency of the coupled system on isolated footings diminishes by 27.52%–58.21%relative to fixed-base conditions,highlighting the significance of accounting for soil-foundation-structure interaction effects.Moreover,a notable increase of 52.97%in the natural frequency of the coupled system is observed as the embedment depth of the footing increases from 0.75 to 6.Additionally,the study demonstrates that the inter-storey drift of the 5-storey building remains well within acceptable limits under dense soil conditions.Consequently,within the parameter range explored in this research,the study concludes that soil-foundation-structure interaction effects are insignificant for low-rise buildings(H≤15 m)supported on isolated footings during seismic events.展开更多
A new structural system called a stepped wall-frame structure is proposed in this study to solve the bottom yielding problem of RC frames, which widely occurred during previous earthquakes such as thc Wcnchuan and Yus...A new structural system called a stepped wall-frame structure is proposed in this study to solve the bottom yielding problem of RC frames, which widely occurred during previous earthquakes such as thc Wcnchuan and Yushu earthquakes in China. A 1/5 scale ordinary RC frame model and a stepped wall-frame model were subjected to shake table motions together to study the seismic behavior of the new structural system. This paper presents the dynamic characteristics, the seismic responses and the failure and collapse mechanism of the two models under low, moderate and high intensity shaking. The test results and further analysis demonstrate that the seismic performance of stepped wall-frame structures is superior to ordinary RC frames in terms of the well-controlled deformation pattern and more uniformly distributed damage. The stepped wall can effectively suppress the bottom yielding mechanism, and is simple, economical and practical tbr engineering practice.展开更多
基金Shandong Provincial Natural Science Foundation for Distinguished Young Scholars under Grant No.ZR2022JQ27the Taishan Scholars Program
文摘Transmission tower-line systems(TTLSs)play a crucial role in the long-distance transmission of electrical energy,often necessitating their crossing through active fault areas.However,previous studies have given limited attention to the seismic performance of fault-crossing transmission TTLSs,particularly in terms of considering the impact of permanent ground motion displacements(PGMDs).This study attempts to address this concern by evaluating the seismic performance of TTLSs exposed to fault earthquakes.Three strike-slip ground motions are carefully selected,and the corresponding PGMDs are accurately replicated through baseline adjustment.A meticulously designed and fabricated reduced-scale experimental model of a TTLS is then employed to investigate the influence of the fault crossing location(FCL)on its seismic performance.The shake table tests conducted unequivocally demonstrate that PGMDs significantly amplify the seismic responses of the TTLS and identify the most unfavorable FCL.Furthermore,a finite element model(FEM)is developed and its accuracy is validated by comparing it with the experimental results.Parametric analyses are conducted to explore the effects of fault crossing angles(FCAs)and PGMD amplitudes on the seismic performances of TTLSs.This study is expected to contribute valuable insights for the seismic design and performance analysis of TTLSs crossing fault areas.
基金supported by the Natural Science Foundation of China(52122811)。
文摘To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Table(NEST)has been developed.The testbed consists of three consecutive floors of steel structure.The bottom two floors provide a space to accommodate a full-scale room.To fully explore the flexibility of NEST,we propose a novel control strategy to generate the required shake table input time histories for the testbed to track the target floor motions of the buildings of interest with high accuracy.The control strategy contains two parts:an inverse dynamic compensation via simulation of feedback control systems(IDCS)algorithm and an offline iteration procedure based on a refined nonlinear numerical model of the testbed.The key aspects of the control strategy were introduced in this paper.Experimental tests were conducted to simulate the seismic responses of a full-scale office room on the 21^(st)floor of a 42-story high-rise building.The test results show that the proposed control strategy can reproduce the target floor motions of the building of interest with less than 20%errors within the specified frequency range.
基金Research fund for earthquake engineering of China Earthquake Administration(201508023)a project of the National Science&Technology Support Program during the Twelfth Five-year Plan Period of China(2015BAK17B03)a general program of National Natural Science Foundation of China(51578515)
文摘Severe damage to suspended ceilings of metal grids and lay-in panels was observed in public buildings during the 2013 M7.0 Lushan earthquake in China. Over the past several years, suspended ceilings have been widely used practice in public buildings throughout China, including government offices, schools and hospitals. To investigate the damage mechanism of suspended ceilings, a series of three-dimensional shake table tests was conducted to reproduce the observed damage. A full-scale reinforced concrete frame was constructed as the testing frame for the ceiling, which was single-story and infilled with brick masonry walls to represent the local construction of low-rise buildings. In general, the ceiling in the tests exhibited similar damage phenomena as the field observations, such as higher vulnerability of perimeter elements and extensive damage to the cross runners. However, it exhibited lower fragility in terms of peak ground/roof accelerations at the initiation of damage. Further investigations are needed to clarify the reasons for this behavior.
基金Major Research Plan of National Natural Science Foundation of China Under Grant No.90815009National Natural Science Foundation of China Under Grant No.50378031 and 50178027Western Transport Construction Technology Projects Under Grant No.2009318000100
文摘This paper describes a shake table test study on the seismic response of low-cap pile groups and a bridge structure in liquefiable ground. The soil profile, contained in a large-scale laminar shear box, consisted of a horizontally saturated sand layer overlaid with a silty clay layer, with the simulated low-cap pile groups embedded. The container was excited in three E1 Centro earthquake events of different levels. Test results indicate that excessive pore pressure (EPP) during slight shaking only slightly accumulated, and the accumulation mainly occurred during strong shaking. The EPP was gradually enhanced as the amplitude and duration of the input acceleration increased. The acceleration response of the sand was remarkably influenced by soil liquefaction. As soil liquefaction occurred, the peak sand displacement gradually lagged behind the input acceleration; meanwhile, the sand displacement exhibited an increasing effect on the bending moment of the pile, and acceleration responses of the pile and the sand layer gradually changed from decreasing to increasing in the vertical direction from the bottom to the top. A jump variation of the bending moment on the pile was observed near the soil interface in all three input earthquake events. It is thought that the shake table tests could provide the groundwork for further seismic performance studies of low-cap pile groups used in bridges located on liquefiable groun.
文摘Bridges are a part of vital infrastructure,which should operate even after a disaster to keep emergency services running.There have been numerous bridge failures during major past earthquakes due to liquefaction.Among other categories of failures,mid span collapse(without the failure of abutments)of pile supported bridges founded in liquefiable deposits are still observed even in most recent earthquakes.This mechanism of collapse is attributed to the effects related to the differential elongation of natural period of the individual piers during liquefaction.A shake table investigation has been carried out in this study to verify mechanisms behind midspan collapse of pile supported bridges in liquefiable deposits.In this investigation,a typical pile supported bridge is scaled down,and its foundations pass through the liquefiable loose sandy soil and rest in a dense gravel layer.White noise motions of increasing acceleration magnitude have been applied to initiate progressive liquefaction and to characterize the dynamic features of the bridge.It has been found that as the liquefaction of the soil sets in,the natural frequency of individual bridge support is reduced,with the highest reduction occurring near the central spans.As a result,there is differential lateral displacement and bending moment demand on the piles.It has also been observed that for the central pile,the maximum bending moment in the pile will occur at a higher elevation,as compared to that of the interface of soils of varied stiffness,unlike the abutment piles.The practical implications of this research are also highlighted.
基金National Natural Science Foundation of China Under Grant No. 50708071National Basic Research of China Under Grant No. 2007CB714202+1 种基金National Key Technology R&D Program Under Grant No. 2006BAJ13B01Shanghai Educational Development Foundation Under Grant No. 2007CG27
文摘Many single-tower reinforced concrete core wall-steel frame (RCC-SF) buildings have been built in China, but there are no buildings of different-height multi-tower hybrid system. A multi-tower RCC-SF tall building was thus studied because of its structural complexity and irregularity. First, a 1/15 scaled model structure was designed and tested on the shake table under minor, moderate, and major earthquake levels. Then, the dynamic responses of the model structure were interpreted to those of the prototype structure according to the similitude theory. Experimental results demonstrate that, despite the complexity of the structure, the lateral deformation bends as the "bending type" and the RC core walls contribute more than the steel frames to resist seismic loads. The maximum inter-story drift of the complex building under minor earthquakes is slightly beyond the elastic limitation specified in the Chinese code, and meets code requirements under major earthquakes. From the test results some suggestions are provided that could contribute favorable effect on the seismic behavior and the displacement of the building.
基金National Key Research and Development Plan,China under Grant No.2017YFC1500702the National Natural Science Foundation of China under Grant No.51478338。
文摘As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years.To fulfill this special requirement imposed by current seismic design codes,reinforcement ratios in the bridge towers have to be kept significantly higher than if limited ductility behavior of the tower is allowed.In addition,since the foundation capacity is closely related to the moment and shear capacities of the bridge tower,a large increase in bridge construction cost for elastically designed cable-stayed bridge is inevitable.To further investigate the possibility of limited ductility bridge tower design strategies,a new 1/20-scale cable-stayed bridge model with H-shaped bridge towers designed according to strong strut-weak tower column design was tested.The shake table experimental results are compared with a previous strong tower column-weak strut designed full bridge model.A comparison of the results show that ductility design with plastic hinges located on tower columns,i.e.,strong strut-weak tower column design,is another effective seismic design strategy that results in only small residual displacement at the top of the tower column,even under very severe earthquake excitations.
基金The National Natural Science Foundation of China(No.41876218,51905210)。
文摘To improve the efficiency and amplify the exciting force of a shake table,a novel variable stiffness mechanism(VSM)constructed by four leaf spring-lever combinations(LSLCs)was designed.Three VSMs were installed in parallel on the traditional hydraulic shake table to constitute a resonant shake table(RST).The static model of the VSM and the dynamic model of the RST were constructed by considering the large deflection of leaf springs and the geometrical nonlinearity of L-shaped levers.The variable stiffness property of LSLCs was analyzed and verified through static experiments.The simulation and vibration experiments on the dynamic properties of the RST prototype were conducted.The results show that compared with traditional shake tables,the RST consumes lower exciting force in a specified frequency bandwidth when outputting the same displacement of vibration.Under a harmonic vibrational excitation,the RST is effective for vibration enhancement using broadband frequency resonance and can save energy to some extent.The broadband resonance technology exhibits considerable potential in practical engineering applications.
基金Basic Science Research Program of the National Research Foundation of Korea under Grant Nos.NRF-2020R1A6A1A03044977 and NRF2022R1A2C2004351。
文摘In this study, shaking table tests were performed to investigate the dynamic characteristics of a mold transformer. Based on the test results, rotary friction dampers were developed to mitigate the excessive lateral displacement that occurred along the direction of the weak stiffness axis of the mold transformer. In addition, shaking table tests were performed by attaching friction dampers to both sides of the mold transformer. Based on the shaking table test results, the natural frequency, mode vector, and damping ratio of the mold transformer were derived using the transfer function and half-power bandwidth. The test results indicated that the use of friction dampers can decrease the displacement and acceleration response of the mold transformer. Finally, dynamic structural models were established considering the component connectivity and mass distribution of the mold transformer. In addition, a numerical strategy was proposed to calibrate the stiffness coefficients of the mold transformer, thereby facilitating the relationship between generalized mass and stiffness. The results indicated that the analytical model based on the calibration strategy of stiffness coefficients can reasonably simulate the dynamic behavior of the mold transformer using friction dampers with regard to transfer function, displacement, and acceleration response.
基金funding support from the National Nature Science Foundation of China(Grant No.41931296)the Open Research Project of Sichuan Provincial Key Laboratory for Major Hazard Source Monitoring and Control(Grant No.KFKT2023-4)the 57#Project(Grant No.JH2024015).
文摘Weak interlayers play a crucial role in the seismic performance of bedding slopes;however,the effects of structural surface development within these layers remain underexplored.This study presents two scaled models of bedding slopes,each with different weak interlayers:one with a homogeneous weak layer and another with discontinuous interfaces.Shaking table tests were conducted to compare their seismic performance.The results show that the peak ground acceleration(PGA)values above the weak interlayer in model A were significantly higher than those in model B,with the differences increasing as the input wave amplitude increased.The peak earth pressure(PEP)values at the tensile failure boundary at the rear edge of model A were also higher,whereas those within the weak layer at the toe of model A were lower than those in model B.Deformation analysis revealed that the maximum principal strain in model A initially appeared at the upper part of the tensile failure boundary,while the maximum shear strain was concentrated near the rear edge within the weak layer.In contrast,model B exhibited the opposite strain distribution.These findings provide insight into the impact of weak interlayers on the dynamic response and deformation of bedding slopes,highlighting the importance of considering this factor in seismic landslide investigations and failure mode predictions.
基金the support from the Outstanding Youth Foundation of Shandong Province(ZR2021YQ31)the National Natural Science Foundation of China(42277135)+5 种基金National Foreign Experts Individual Program(Category Y)(Grant No.Y20240084)the National Natural Science Foundation of China Joint Fund Key Project(U2006225)Special Fund for Taishan Scholar Projectthe Youth Project of Open Funding from Engineering Research Center of Concrete Technology under Marine Environment,Ministry of Education(Grant No.TMduracon202217)the funding from Key Laboratory of Ministry of Education for Coastal Disaster and Protection,Hohai University(Grant No.202206)Shandong Provincial Overseas High-Level Talent Workstation,China。
文摘Seismic-induced landslides critically threaten infrastructure and human safety,especially in sandy slopes where conventional stabilization methods often fail under dynamic loading.This study evaluates circular open-ended anti-slide pipe piles embedded in a two-layer sandy slope with differing geotechnical properties.Ten physical models,including five freefield and five pile-reinforced slopes,were tested on a shaking table.Key seismic responses—acceleration,soil displacement,and bending moments—were monitored using accelerometers,strain gauges,and Digital Image Correlation(DIC).Complementary numerical simulations using Abaqus with a Mohr–Coulomb model validated experimental results.Soil displacement in free-field models under 0.25g shaking was about 3.5 times greater than in reinforced slopes.Bending moments increased with seismic intensity,peaking at depths around five times the pile diameter.Limitations including simplified two-layer soil representation,idealized seismic inputs,and boundary effects inherent to laboratory models restrict direct field application but enable controlled analysis.By combining physical experiments with numerical modeling,the study provides a robust and validated framework for seismic slope stabilization.This integrated approach enhances understanding of soil–pile interaction under seismic loads and offers targeted insights for developing safer and more reliable geotechnical design strategies in earthquake-prone areas.
基金funded by the National Natural Science Foundation of China(Grant No.42377195)。
文摘A fault is a geological structure characterized by significant displacement of rock masses along a fault plane within the Earth's crust.The Yunnan Tabaiyi Tunnel intersects multiple fault zones,making tunnel construction in fault-prone areas particularly vulnerable to the effects of fault activity due to the complexities of the surrounding geological environment.To investigate the dynamic response characteristics of tunnel structures under varying surrounding rock conditions,a three-dimensional large-scale shaking table physical model test was conducted.This study also aimed to explore the damage mechanisms associated with the Tabaiyi Tunnel under seismic loading.The results demonstrate that poor quality surrounding rock enhances the seismic response of the tunnel.This effect is primarily attributed to the distribution characteristics of acceleration,dynamic strain,and dynamic soil pressure.A comparison between unidirectional and multi-directional(including vertical)seismic motions reveals that vertical seismic motion has a more significant impact on specific tunnel locations.Specifically,the maximum tensile stress is observed at the arch shoulder,with values ranging from 60 to 100 k Pa.Moreover,NPR(Non-Prestressed Reinforced)anchor cables exhibit a substantial constant resistance effect under low-amplitude seismic waves.However,when the input earthquake amplitude reaches 0.8g,local sliding occurs at the arch shoulder region of the NPR anchor cable.These findings underscore the importance of focusing on seismic mitigation measures in fault zones and reinforcing critical areas,such as the arch shoulders,in practical engineering applications.
基金The National Key Research and Development Program of China(No.2021YFB2600600,2021YFB2600601)the National Natural Science Foundation of China(No.52408456)+2 种基金China Postdoctoral Science Foundation(No.2022M720533)College Students’Innovative Entrepreneurial Training Plan Program(No.202410710009)Key Research and Development Program of Shaanxi,China(No.2024SF-YBXM-659).
文摘Shaking table tests are widely used to evaluate seismic effects on railway structures,but accurately measuring rail displacement remains a significant challenge owing to the nonlinear characteristics of large displacements,ambient noise interference,and limitations in displacement meter installation.In this paper,a novel method that integrates the Kanade-Lucas-Tomasi(KLT)feature tracker with an extended Kalman filter(EKF)is presented for measuring rail displacement during shaking table tests.The method employs KLT feature tracker and a random sample consensus algorithm to extract and track key feature points,while EKF optimally estimates dynamic states by accounting for system noise and observation errors.Shaking table test results demonstrate that the proposed method achieves an acceleration root mean square error of 0.300 m/s^(2)and a correlation with accelerometer data exceeding 99.7%,significantly outper-forming the original KLT approach.This innovative method provides a more efficient and reliable solution for measuring rail displacement under large nonlinear vibrations.
基金Key International(Regional)Joint Research Project under Grant No.52020105002National Natural Science Foundation of China under Grant No.51991393。
文摘The relative stiffness between underground structures and surrounding soil may significantly influence the dynamic response of such structures.In this study,two underground pipelines were fabricated using rubber joints with varying stiffness,and the corresponding dynamic response was evaluated.Model soils were prepared based on similarity ratios.Next,reduced-scale shaking table tests were conducted to investigate the impact of circular underground structures with varying stiffness joints on the amplification of ground acceleration,dynamic response,and deformation patterns of the underground pipelines.The comparative analysis showed that structures with lower stiffness exert less constraint on the surrounding soil,resulting in a higher amplification factor of ground acceleration.The seismic response of less stiff structures is generally 1.1 to 1.3 times the response of the stiffer structures.Therefore,the seismic response of the variable stiffness pipeline exhibits pronounced characteristics.Rubber joints effectively reduce the seismic response of underground structures,demonstrating favorable isolation effects.Consequently,relative stiffness plays a crucial role in the seismic design of underground structures,and the use of rubber materials in underground structures is advantageous.
基金supported by TUBITAK through the 110G093 research project and TUBITAK BIDEB 2215 Program
文摘Seismic isolation systems designed for extreme events may likely experience low to moderate earthquakes during the design life of the structure rather than the extreme event itself.In new seismic building design codes, low and moderate earthquakes are also mandatory to be investigated in Turkey and some other countries. One of the main reasons is to protect the integrity of non-structural elements or machines during these types of earthquakes. The selection of appropriate seismic isolation is typically decided based on their forcedisplacement characteristics and amount of energy dissipation per cycle. The same energy dissipation per cycle(EDC) can be achieved by high force-low displacement or low force-high displacement response. The focus of this research is given to identify the performance of ball rubber bearing isolation systems compared to different or similar EDC units such as elastomeric bearings and lead rubber bearings through a series of shake table tests performed at low to moderate earthquake levels. Shake table tests were conducted on an almost full scale short span bridge. The tests have revealed that the ball rubber bearings are superior to elastomeric bearings in terms of EDC and can match EDC of LRB. However, although LRB and BRB have the same EDC, BRB is more beneficial to use under low to moderate earthquakes since BRB can transmit less force with larger displacement compared to LRB and LRB can sometimes stay in elastic range with an ineffective EDC as a stiffer elastomeric bearing.
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant Nos.2021EEEVL0204 and 2018A02。
文摘As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.
基金National Natural Science Foundation of China under Grant Nos. 52178336 and 52108324Natural Science Research Project of Colleges and Universities in Jiangsu Province of China under Grant No. 18KJA560002+1 种基金the Middle-Aged&Young Science Leaders of Qinglan Project of Universities in Jiangsu Province of ChinaPostgraduate Research&Practice Innovation Program in Jiangsu Province of China under Grant No. KYCX24_1585
文摘The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The macro phenomena of the two different foundation models are described and analyzed.The effects of the replacement of EPS composite soil on seismic-induced liquefaction of backfill and the dynamic performance of a caisson structure are evaluated in detail.The results show that the excess pore water pressure generation in the CES is significantly slower than that in the CSS during the shaking.The dynamic earth pressure acting on the caisson has a triangular shape.The response of horizontal acceleration,displacement,settlement,and rotation angle of the caisson in the CES is smaller than that in the CSS,which means the caisson in the CES has a better seismic performance.Furthermore,the out-of-phase phenomenon between dynamic earth thrust and inertial force in the CES is more obvious than that in the CSS,which is beneficial to reduce the lateral force and improve the stability of the caisson structure.
基金National Natural Science Foundation of China under Grant No.52078020。
文摘When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response of underground structures in liquefiable interlayer sites,and a valid numerical model was obtained through simulation model test.Finally,the calibrated numerical model was used to perform further research on the influence of various distribution characteristics of liquefiable interlayers on the seismic reaction of underground structures.The key findings are as follows.The structure faces the most unfavorable condition once a liquefiable layer is located in the middle of the underground structure.When a liquefiable layer exists in the middle of the structure,the seismic reactions of both the underground structure and model site will increase with the rise of the thickness of the liquefiable interlayer.The inter-story drift of the structure in the non-liquefiable site is much smaller than that in the liquefiable interlayer site.The inter-story drift of the structure is not only associated with the site displacement and the soil-structure stiffness ratio but also closely associated with the slippage of the soil-structure contact interface under the condition of large deformation of the site.
基金fellowship received from the Department of Science and Technology(DST)under a unique scheme,“Innovation in Science Pursuit for Inspired Research(INSPIRE),”under the file number 20190000871,during the present work。
文摘The present study investigates the influence of embedment depth of isolated footing supporting moment-resisting frame buildings through scaled-down tests.These experiments utilize scaled models representing different building aspect ratios and footing embedment depths.All the model tests are subjected to scaled-down input ground motions of different intensities and magnitudes.These model tests are performed in laminar shear containers through shake table testing.The results obtained for different cases of soil-foundation-structure systems and fixed-base conditions are expressed in terms of natural frequency,peak spectral acceleration,frequency response,lateral deformation,inter-storey drifts,and rocking of the foundation.The analysis reveals that the natural frequency of the coupled system on isolated footings diminishes by 27.52%–58.21%relative to fixed-base conditions,highlighting the significance of accounting for soil-foundation-structure interaction effects.Moreover,a notable increase of 52.97%in the natural frequency of the coupled system is observed as the embedment depth of the footing increases from 0.75 to 6.Additionally,the study demonstrates that the inter-storey drift of the 5-storey building remains well within acceptable limits under dense soil conditions.Consequently,within the parameter range explored in this research,the study concludes that soil-foundation-structure interaction effects are insignificant for low-rise buildings(H≤15 m)supported on isolated footings during seismic events.
基金Special Fund for Earthquake Research under Grant No.201208013National key Technology R&D Program under Grant No.2012BAK15B05Basic Research Fund of Institute of Engineering Mechanics,CEA under Grant No.2010A04
文摘A new structural system called a stepped wall-frame structure is proposed in this study to solve the bottom yielding problem of RC frames, which widely occurred during previous earthquakes such as thc Wcnchuan and Yushu earthquakes in China. A 1/5 scale ordinary RC frame model and a stepped wall-frame model were subjected to shake table motions together to study the seismic behavior of the new structural system. This paper presents the dynamic characteristics, the seismic responses and the failure and collapse mechanism of the two models under low, moderate and high intensity shaking. The test results and further analysis demonstrate that the seismic performance of stepped wall-frame structures is superior to ordinary RC frames in terms of the well-controlled deformation pattern and more uniformly distributed damage. The stepped wall can effectively suppress the bottom yielding mechanism, and is simple, economical and practical tbr engineering practice.