THE power industrial control system(power ICS)is thecore infrastructure that ensures the safe,stable,and efficient operation of power systems.Its architecture typi-cally adopts a hierarchical and partitioned end-edge-...THE power industrial control system(power ICS)is thecore infrastructure that ensures the safe,stable,and efficient operation of power systems.Its architecture typi-cally adopts a hierarchical and partitioned end-edge-cloud collaborative design.However,the large-scale integration ofdistributed renewable energy resources,coupled with the extensivedeployment of sensing and communication devices,has resulted inthe new-type power system characterized by dynamic complexityand high uncertainty[1]-[4].展开更多
The real-time and accurate calculation of electricity indirect carbon emissions is not only the critical component for quantifying the carbon emission levels of the power system but also an effective mean to guide ele...The real-time and accurate calculation of electricity indirect carbon emissions is not only the critical component for quantifying the carbon emission levels of the power system but also an effective mean to guide electricity users in carbon reduction and promote power industry low-carbon transformation.Fundamentally,calculating indirect carbon emissions involves allocating direct carbon emission data from the power source side,indicating that accurate indirect emission results rely on the precise measurement of power source emissions.However,existing research on indirect carbon emissions in large-scale power systems rarely accounts for variations in carbon emission characteristics under different operating conditions of power sources,such as rated/non-rated operating conditions and ramping up/down conditions,making it difficult to reflect source-side and load-side carbon emission information variation during providing ancillary services.Quadratic and exponential functions are proposed to characterize the energy consumption profiles of coal-fired and gas-fired power generation,respectively,to construct a refined carbon emission model for power sources.By leveraging the theory of power system carbon flow,we analyze how variable operating conditions of power sources impact indirect carbon emissions.Case studies demonstrate that changes in power source emissions under variable conditions have a significant effect on the indirect carbon emissions of power grids.展开更多
Space-Based Solar Power(SBSP) presents a promising solution for achieving carbon neutrality and Renewable Electricity 100%(RE100) goals by offering a stable and continuous energy supply. However, its commercialization...Space-Based Solar Power(SBSP) presents a promising solution for achieving carbon neutrality and Renewable Electricity 100%(RE100) goals by offering a stable and continuous energy supply. However, its commercialization faces significant obstacles due to the technical challenges of long-distance microwave Wireless Power Transmission(WPT) from geostationary orbit. Even ground-based kilometer-scale WPT experiments remain difficult because of limited testing infrastructure, high costs, and strict electromagnetic wave regulations. Since the 1975 NASA-Raytheon experiment, which successfully recovered 30 kW of power over 1.55 km, there has been little progress in extending the transmission distance or increasing the retrieved power. This study proposes a cost-effective methodology for conducting long-range WPT experiments in constrained environments by utilizing existing infrastructure. A deep space antenna operating at 2.08 GHz with an output power of 2.3 kW and a gain of 55.3 dBi was used as the transmitter. Two test configurations were implemented: a 1.81 km ground-to-air test using an aerostat to elevate the receiver and a 1.82 km ground-to-ground test using a ladder truck positioned on a plateau. The rectenna consists of a lightweight 3×3 patch antenna array(0.9 m × 0.9 m), accompanied by a steering device and LED indicators to verify power reception. The aerostat-based test achieved a power density of 154.6 mW/m2, which corresponds to approximately 6.2% of the theoretical maximum. The performance gap is primarily attributed to near-field interference, detuning of the patch antenna, rectifier mismatch, and alignment issues. These limitations are expected to be mitigated through improved patch antenna fabrication, a transition from GaN to GaAs rectifiers optimized for lower input power, and the implementation of an automated alignment system. With these enhancements, the recovered power is expected to improve by approximately four to five times. The results demonstrate a practical and scalable framework for long-range WPT experiments under constrained conditions and provide key insights for advancing SBSP technology.展开更多
This paper develops an innovative computational model for assessing the Carbon Emission Factor(CEF)of provincial power systems that incorporates inter-provincial electricity transfers and hybrid generation portfolios ...This paper develops an innovative computational model for assessing the Carbon Emission Factor(CEF)of provincial power systems that incorporates inter-provincial electricity transfers and hybrid generation portfolios combining conventional and renewable sources.A key contribution lies in evaluating how deep regulation of thermal power plants influence the carbon intensity of coal-fired generation and coal-fired generation together with high penetration renewables.Furthermore,the study quantitatively analyzes the role of renewable energy consumption and the prospective application of Carbon Capture and Storage(CCS)in reducing system-wide CEF.Based on this framework,the paper proposes phased carbon emission targets for Guangdong’s power system for key milestone years(2030,2045,2060),along with targeted implementation strategies.Results demonstrate that in renewable-dominant systems,deep regulation of thermal units,load peak-shaving,and deployment of flexible resources such as energy storage are effective in cutting carbon intensity.To achieve the defined targets—0.367 kg/kWh by 2030,0.231 kg/kWh by 2045,and 0.032 kg/kWh by 2060—the following innovation-focused policy is recommended:in early stage,mainly on expansion of renewable capacity and inter-provincial transmission infrastructure along with energy storage deployment;in mid-term,mainly on enhancement of electricity market mechanisms to promote green power trading and demand-side flexibility;and in late-stage,mainly on systematic retirement of conventional coal assets coupled with large-scale CCS adoption and carbon sink mechanisms.展开更多
The world’s most powerful offshore wind turbine has begun feeding electricity into the grid off the coast of southeast China,marking a major technological leap in the country’s wind power industry.The colossal turbi...The world’s most powerful offshore wind turbine has begun feeding electricity into the grid off the coast of southeast China,marking a major technological leap in the country’s wind power industry.The colossal turbine,developed and installed by China Three Gorges Corp.(CTG),is located in the Phase II Liuao offshore wind farm,more than 30 km off the coast of Fujian in waters deeper than 40 metres.The 20-mw unit successfully completed commissioning and started operation on 5 February,CTG announced.展开更多
The large-scale integration of power electronic interface-based renewable energy with intermittency and uncertainty poses severe challenges for power system secure operation,especially frequency security.Determining t...The large-scale integration of power electronic interface-based renewable energy with intermittency and uncertainty poses severe challenges for power system secure operation,especially frequency security.Determining the system frequency regulation ability under contingency is an open problem.To bridge this gap,a unit commitment(UC)to concentrate solar power considering operational risk and frequency dynamic constraints(RFUC-CSP)is proposed in this paper.A concentrating solar power(CSP)plant with renewable energy characteristics and synchronous units is employed to improve renewable energy utilization and provide frequency support.Firstly,an analytical operational risk model is established to quantify the operational risk under renewable energy integration.Then,the frequency dynamic response characteristic of the system is considered to construct frequency security constraints.A novel RFUC-CSP framework is formulated by incorporating operational risk and frequency security constraints into the UC model,which can allocate operational flexibility of power systems by optimizing the admissible uncertainty level to reduce operational risk.The effectiveness of the proposed RFUC-CSP model is demonstrated by case studies on the modified IEEE 30-bus and IEEE RTS-79 system,and the cost-effectiveness of the CSP plant is quantified.展开更多
The rapid development of wind energy in the power sectors raises the question about the reliability of wind turbines for power system planning and operation.The electrical subsystem of wind turbines(ESWT),which is one...The rapid development of wind energy in the power sectors raises the question about the reliability of wind turbines for power system planning and operation.The electrical subsystem of wind turbines(ESWT),which is one of the most vulnerable parts of the wind turbine,is investigated in this paper.The hygrothermal aging of power electronic devices(PEDs)is modeled for the first time in the comprehensive reliability evaluation of ESWT,by using a novel stationary“circuit-like”approach.First,the failure mechanism of the hygrothermal aging,which includes the solder layer fatigue damage and packaging material performance degradation,is explained.Then,a moisture diffusion resistance concept and a hygrothermal equivalent circuit are proposed to quantitate the hygrothermal aging behavior.A conditional probability function is developed to calculate the time-varying failure rate of PEDs.At last,the stochastic renewal process is simulated to evaluate the reliability for ESWT through the sequential Monte Carlo simulation,in which failure,repair,and replacement states of devices are all included.The effectiveness of our proposed reliability evaluation method is verified on an ESWT in a 2 MW wind turbine use time series data collected from a wind farm in China.展开更多
In real industrial microgrids(MGs),the length of the primary delivery feeder to the connection point of the main substation is sometimes long.This reduces the power factor and increases reactive power absorption along...In real industrial microgrids(MGs),the length of the primary delivery feeder to the connection point of the main substation is sometimes long.This reduces the power factor and increases reactive power absorption along the primary delivery feeder from the external network.Besides,the giant induction electro-motors as the working horse of industries requires remarkable amounts of reactive power for electro-mechanical energy conversions.To reduce power losses and operating costs of the MG as well as to improve the voltage quality,this study aims at providing an insightful model for optimal placement and sizing of reactive power compensation capacitors in an industrial MG.In the presented model,the objective function considers voltage profile and network power factor improvement at the MG connection point.Also,it realizes power flow equations within which all operational security constraints are considered.Various reactive power compensation strategies including distributed group compensation,centralized compensation at the main substation,and distributed compensation along the primary delivery feeder are scrutinized.A real industrial MG,say as Urmia Petrochemical plant,is considered in numerical validations.The obtained results in each scenario are discussed in depth.As seen,the best performance is obtained when the optimal location and sizing of capacitors are simultaneously determined at the main buses of the industrial plants,at the main substation of the MG,and alongside the primary delivery feeder.In this way,74.81%improvement in power losses reduction,1.3%lower active power import from the main grid,23.5%improvement in power factor,and 37.5%improvement in network voltage deviation summation are seen in this case compared to the base case.展开更多
Ensuring reliable power supply in urban distribution networks is a complex and critical task.To address the increased demand during extreme scenarios,this paper proposes an optimal dispatch strategy that considers the...Ensuring reliable power supply in urban distribution networks is a complex and critical task.To address the increased demand during extreme scenarios,this paper proposes an optimal dispatch strategy that considers the coordination with virtual power plants(VPPs).The proposed strategy improves systemflexibility and responsiveness by optimizing the power adjustment of flexible resources.In the proposed strategy,theGaussian Process Regression(GPR)is firstly employed to determine the adjustable range of aggregated power within the VPP,facilitating an assessment of its potential contribution to power supply support.Then,an optimal dispatch model based on a leader-follower game is developed to maximize the benefits of the VPP and flexible resources while guaranteeing the power balance at the same time.To solve the proposed optimal dispatch model efficiently,the constraints of the problem are reformulated and resolved using the Karush-Kuhn-Tucker(KKT)optimality conditions and linear programming duality theorem.The effectiveness of the strategy is illustrated through a detailed case study.展开更多
To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distributio...To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distribution networks,this paper adopts a component sharing mechanism to propose a composite multi-port hybrid DC circuit breaker(CM-HCB)with DC power flow and fault current limitation abilities,as well as reduced component costs.The proposed CM-HCB topology enables the sharing of the main breaker branch(MB)and the energy dissipation branch,while the load commutation switches(LCSs)in the main branch are reused as power flow control components,enabling flexible regulation of power flow in multiple lines.Meanwhile,by reconstructing the current path during the fault process,the proposed CM-HCB can utilize the internal coupled inductor to limit the current rise rate at the initial stage of the fault,significantly reducing the requirement for breaking current.A detailed study on the topological structure,steady-state power flow regulation mechanism,transient fault isolation mechanism,control strategy and characteristic analysis of the proposed CM-HCB is presented.Then,a Matlab/Simulink-based meshed three-terminal DC grid simulation platform with the proposed CM-HCB is built.The results indicate that the proposed CM-HCB can not only achieve flexible power flow control during steady-state operation,but also obtain current rise limitation and fault isolation abilities under short-circuit fault conditions,verifying its correctness and effectiveness.Finally,a comparative economic analysis is conducted between the proposed CM-HCB and the other two existing solutions,confirming that its component sharing mechanism can significantly reduce the number of components,lower system costs,and improve component utilization.展开更多
Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency devia...Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency deviations,voltage fluctuations,and poor reactive power coordination,posing serious challenges to grid stability.Conventional Interconnection FlowControllers(IFCs)primarily regulate active power flowand fail to effectively handle dynamic frequency variations or reactive power sharing in multi-microgrid networks.To overcome these limitations,this study proposes an enhanced Interconnection Flow Controller(e-IFC)that integrates frequency response balancing and an Interconnection Reactive Power Flow Controller(IRFC)within a unified adaptive control structure.The proposed e-IFC is implemented and analyzed in DIgSILENT PowerFactory to evaluate its performance under various grid disturbances,including frequency drops,load changes,and reactive power fluctuations.Simulation results reveal that the e-IFC achieves 27.4% higher active power sharing accuracy,19.6% lower reactive power deviation,and 18.2% improved frequency stability compared to the conventional IFC.The adaptive controller ensures seamless transitions between grid-connected and islanded modes and maintains stable operation even under communication delays and data noise.Overall,the proposed e-IFCsignificantly enhances active-reactive power coordination and dynamic stability in renewable-integrated multi-microgrid systems.Future research will focus on coupling the e-IFC with tertiary-level optimization frameworks and conducting hardware-in-the-loop validation to enable its application in large-scale smart microgrid environments.展开更多
Various factors,including weak tie-lines into the electric power system(EPS)networks,can lead to low-frequency oscillations(LFOs),which are considered an instant,non-threatening situation,but slow-acting and poisonous...Various factors,including weak tie-lines into the electric power system(EPS)networks,can lead to low-frequency oscillations(LFOs),which are considered an instant,non-threatening situation,but slow-acting and poisonous.Considering the challenge mentioned,this article proposes a clustering-based machine learning(ML)framework to enhance the stability of EPS networks by suppressing LFOs through real-time tuning of key power system stabilizer(PSS)parameters.To validate the proposed strategy,two distinct EPS networks are selected:the single-machine infinite-bus(SMIB)with a single-stage PSS and the unified power flow controller(UPFC)coordinated SMIB with a double-stage PSS.To generate data under various loading conditions for both networks,an efficient but offline meta-heuristic algorithm,namely the grey wolf optimizer(GWO),is used,with the loading conditions as inputs and the key PSS parameters as outputs.The generated loading conditions are then clustered using the fuzzy k-means(FKM)clustering method.Finally,the group method of data handling(GMDH)and long short-term memory(LSTM)ML models are developed for clustered data to predict PSS key parameters in real time for any loading condition.A few well-known statistical performance indices(SPI)are considered for validation and robustness of the training and testing procedure of the developed FKM-GMDH and FKM-LSTM models based on the prediction of PSS parameters.The performance of the ML models is also evaluated using three stability indices(i.e.,minimum damping ratio,eigenvalues,and time-domain simulations)after optimally tuned PSS with real-time estimated parameters under changing operating conditions.Besides,the outputs of the offline(GWO-based)metaheuristic model,proposed real-time(FKM-GMDH and FKM-LSTM)machine learning models,and previously reported literature models are compared.According to the results,the proposed methodology outperforms the others in enhancing the stability of the selected EPS networks by damping out the observed unwanted LFOs under various loading conditions.展开更多
The use of alternative fuels to generate mechanical and thermal energy in engines is a promising and sought-after technological area with its own unique advantages and characteristics.Consequently,enhancing the techni...The use of alternative fuels to generate mechanical and thermal energy in engines is a promising and sought-after technological area with its own unique advantages and characteristics.Consequently,enhancing the technical,economic,and environmental efficiency of gas engines fueled by propane-butane mixture and syngas through optimized operating cycle parameters(including valve timing,ignition timing angle,fuel mixture composition,and compression ratio)is a pressing imperative for scientific and energy sectors.The aim of the study was to investigate and compare the performance of an engine with different compression ratios running on a propane-butane mixture and laboratory syngas.The research’s primary originality lies in its joint study of syngas production technology and the evaluation of the efficiency of a mini power plant fueled by the resulting gas and conventional gas.This article presents a description of the experimental setup,data on measuring instruments,technical characteristics of the mini-power plant,the process for obtaining laboratory syngas,the properties of the gaseous fuels used,and experimental methods.Data on air and fuel consumption,as well as engine efficiency at different compression ratios when running on a propane-butane mixture and syngas,were obtained and analyzed.Converting an engine from a propane-butane mixture to syngas results in a reduction in power of almost 30% and efficiency by 13%–33%.Increasing the compression ratio by 0.9 units causes a rise in maximum efficiency from 0.177 to 0.235 for an engine running on a propane-butane mixture and an increase in maximum efficiency from 0.136 to 0.161 for a syngas engine.It has been confirmed that the compression ratio significantly impacts the technical and economic performance of an engine running on gaseous fuel.The obtained results can be used to modernize existing engines for operation on alternative fuels(syngas)and to design new mini-power plants with promising technical,economic,and environmental characteristics.展开更多
The increasing integration of electric vehicle(EV)loads into power systems necessitates understanding their impact on stability.Small-magnitude perturbations,if persistent,can cause low-frequency oscillations,leading ...The increasing integration of electric vehicle(EV)loads into power systems necessitates understanding their impact on stability.Small-magnitude perturbations,if persistent,can cause low-frequency oscillations,leading to synchronism loss and mechanical stress.This work analyzes the effect of voltage-dependent EV loads on this small-signal stability.The study models an EV load within a Single-Machine Infinite Bus(SMIB)system.It specifically evaluates the influence of EV charging through the DC link capacitor of a Unified Power Flow Controller(UPFC),a key device for damping oscillations.The system’s performance is compared to a modified version equipped with both a UPFC and a Linear Quadratic Regulator(LQR)controller.Results confirm the significant influence of EV charging on the power network.The analysis demonstrates that the best performance is achieved with the SMIB system utilizing the combined UPFC and LQR controller.This configuration effectively dampens low-frequency oscillations,yielding superior results by reducing the system’s rise time,settling time,and peak overshoot.展开更多
While the instantaneous power of triboelectric nanogenerators(TENGs)has significantly increased,the average power remains unsatisfactory.Achieving a continuous and stable output remains a significant challenge.Herein,...While the instantaneous power of triboelectric nanogenerators(TENGs)has significantly increased,the average power remains unsatisfactory.Achieving a continuous and stable output remains a significant challenge.Herein,a self-excited vibration TENG inspired by woodpeckers is proposed.This structure converts gravitational potential energy into the continuous vibration of a cantilever beam.A dynamic simulation model of the system is established,and the influence of different structural parameters on the motion characteristics and electrical performance is discussed.Meanwhile,the experimental results indicate that the accelerated motion(approximate free-fall motion)is transformed into approximately uniform velocity motion.For a 3 cm^(2) TENG,the instantaneous power density reaches 2.03 W m^(-2),and the average power is 127%higher than that of the conventional cantilever beam mode.The proposed self-excited vibration mechanism is a promising approach for enhancing the average power and operational duration of TENGs.It shows great potential in fluid energy harvesting.展开更多
Background:Low relative sit-to-stand(STS)power has emerged as a critical predictor of adverse health outcomes,such as frailty and disability,in older adults.However,its impact on falls,fractures,hospitalizations,and a...Background:Low relative sit-to-stand(STS)power has emerged as a critical predictor of adverse health outcomes,such as frailty and disability,in older adults.However,its impact on falls,fractures,hospitalizations,and all-cause mortality remains unclear.Therefore,this longitudinal study aimed to investigate the potential associations between low relative STS power and these adverse health outcomes in older adults.Methods:A total of 1876 older adults(aged≥65 years,56.4%women)were included from the Toledo Study for Healthy Aging.Relative STS power was assessed using the 30-s STS test and the Alcazar equation.Participants were categorized as having low relative STS power based on previously established cut-off points(2.53 W/kg for men and 2.01 W/kg for women).Falls and fractures(hip and all-type)within the previous year were recorded.Hospitalizations and all-cause mortality were obtained during a follow-up of 6.8±3.1 years(mean±SD;median=7.8 years;interquartile range:3.9-10.1 years)and 9.7±3.5 years(median=10.9 years;interquartile range:8.2-12.5 years),respectively.Generalized linear mixed models,binary logistic regression,and proportional hazards regression adjusted for age,educational level,and comorbidities were used.Results:In men,low relative STS power was significantly associated with an increased likelihood of history of falls(odds ratio(OR)=1.73,95%confidence interval(95%CI):1.08-2.75,p=0.022)and all-type fractures(OR=1.86,95%CI:1.21-2.84,p=0.004)in the previous year.In women,low relative STS power was associated with a higher probability of hip fractures within the previous year(OR=3.25,95%CI:1.07-9.86,p=0.038).Low relative STS power predicted hospitalizations in women(hazard ratio(HR)=1.29,95%CI:1.06-1.58,p=0.012)and longer hospital stays in both men(p=0.020)and women(p=0.033).Low relative STS power significantly increased all-cause mortality in both men(HR=1.57,95%CI:1.26-1.97,p<0.001)and women(HR=2.04,95%CI:1.51-2.74,p<0.001).Conclusion:Low relative STS power was associated with history of hip fractures in women,whereas in men it was associated with history of falls and all-type fractures.Low relative STS power predicted hospitalizations in women but not in men.In both men and women,low relative STS power was associated with longer hospital stays and increased risk of all-cause mortality.展开更多
The energy transition inspired by carbon neutrality targets and the increasing threat of extreme events raise multi-objective development requirements for power systems.This paper proposes a multi-objective resource a...The energy transition inspired by carbon neutrality targets and the increasing threat of extreme events raise multi-objective development requirements for power systems.This paper proposes a multi-objective resource allocation model to determine the type,number and location of flexible resources to increase the values of resilience,carbon reduction and renewable energy consumption.To evaluate the values of resilience,a restoration model for transmission systems is established that considers the coordination of fossil-fuel generators,energy storage systems(ESSs)and renewable energy generators in building restoration paths.The collaborative power-carbon-tradable green certificate(TGC)market model is then applied to evaluate the resource values in terms of carbon reduction and renewable energy consumption.Finally,the model is formulated as a mixed-integer linear programming(MILP)with a nonconvex feasible domain,and the normalized normal constraint(NNC)method is applied to obtain approximate Pareto frontiers for decision makers.Case studies validate the effectiveness of the proposed model in improving multi-factor values and analyze the impact of resource regulation capacity on values of restoration and carbon reduction.展开更多
To improve the theoretical prediction accuracy of static mechanical quantities in MEMS cantilever beams for microwave power detection chips,a distributed static model is proposed based on the deflection equation.An an...To improve the theoretical prediction accuracy of static mechanical quantities in MEMS cantilever beams for microwave power detection chips,a distributed static model is proposed based on the deflection equation.An analytical frame-work is established through the precise characterization of cantilever beam bending.The framework can accurately extract key electromechanical parameters,and the correlation between these parameters and geometric changes is systematically studied.Results show that the pull-in voltage increases with the gap but decreases with the length.The predicted pull-in voltage indi-cates a relative error of only 6.5%between the distributed static model and the simulation,which is significantly lower than that of the other two models.The overload power and sensitivity are also analyzed to facilitate performance trade-offs in chip design.The measured return loss varies between-66.46 and-10.56 dB over the 8-12 GHz frequency band,exhibiting a charac-teristic V-shaped trend.Moreover,the measured sensitivity of 66.5 fF/W closely matches the theoretical value of 69.3 fF/W,show-ing a relative error of 5.6%.These findings confirm that the distributed model outperforms the other two in terms of both accu-racy and physical realism,thereby providing important reference for the design of microwave power detection chips.展开更多
基金partially supported by the National Natural Science Foundation of China(62293500,62293505,62233010,62503240)Natural Science Foundation of Jiangsu Province(BK20250679)。
文摘THE power industrial control system(power ICS)is thecore infrastructure that ensures the safe,stable,and efficient operation of power systems.Its architecture typi-cally adopts a hierarchical and partitioned end-edge-cloud collaborative design.However,the large-scale integration ofdistributed renewable energy resources,coupled with the extensivedeployment of sensing and communication devices,has resulted inthe new-type power system characterized by dynamic complexityand high uncertainty[1]-[4].
基金supported by the Science and Technology Project of China Southern Power Grid Co.,Ltd.(ZBKTM20232244)the Project of National Natural of Science Foundation of China(52477103).
文摘The real-time and accurate calculation of electricity indirect carbon emissions is not only the critical component for quantifying the carbon emission levels of the power system but also an effective mean to guide electricity users in carbon reduction and promote power industry low-carbon transformation.Fundamentally,calculating indirect carbon emissions involves allocating direct carbon emission data from the power source side,indicating that accurate indirect emission results rely on the precise measurement of power source emissions.However,existing research on indirect carbon emissions in large-scale power systems rarely accounts for variations in carbon emission characteristics under different operating conditions of power sources,such as rated/non-rated operating conditions and ramping up/down conditions,making it difficult to reflect source-side and load-side carbon emission information variation during providing ancillary services.Quadratic and exponential functions are proposed to characterize the energy consumption profiles of coal-fired and gas-fired power generation,respectively,to construct a refined carbon emission model for power sources.By leveraging the theory of power system carbon flow,we analyze how variable operating conditions of power sources impact indirect carbon emissions.Case studies demonstrate that changes in power source emissions under variable conditions have a significant effect on the indirect carbon emissions of power grids.
文摘Space-Based Solar Power(SBSP) presents a promising solution for achieving carbon neutrality and Renewable Electricity 100%(RE100) goals by offering a stable and continuous energy supply. However, its commercialization faces significant obstacles due to the technical challenges of long-distance microwave Wireless Power Transmission(WPT) from geostationary orbit. Even ground-based kilometer-scale WPT experiments remain difficult because of limited testing infrastructure, high costs, and strict electromagnetic wave regulations. Since the 1975 NASA-Raytheon experiment, which successfully recovered 30 kW of power over 1.55 km, there has been little progress in extending the transmission distance or increasing the retrieved power. This study proposes a cost-effective methodology for conducting long-range WPT experiments in constrained environments by utilizing existing infrastructure. A deep space antenna operating at 2.08 GHz with an output power of 2.3 kW and a gain of 55.3 dBi was used as the transmitter. Two test configurations were implemented: a 1.81 km ground-to-air test using an aerostat to elevate the receiver and a 1.82 km ground-to-ground test using a ladder truck positioned on a plateau. The rectenna consists of a lightweight 3×3 patch antenna array(0.9 m × 0.9 m), accompanied by a steering device and LED indicators to verify power reception. The aerostat-based test achieved a power density of 154.6 mW/m2, which corresponds to approximately 6.2% of the theoretical maximum. The performance gap is primarily attributed to near-field interference, detuning of the patch antenna, rectifier mismatch, and alignment issues. These limitations are expected to be mitigated through improved patch antenna fabrication, a transition from GaN to GaAs rectifiers optimized for lower input power, and the implementation of an automated alignment system. With these enhancements, the recovered power is expected to improve by approximately four to five times. The results demonstrate a practical and scalable framework for long-range WPT experiments under constrained conditions and provide key insights for advancing SBSP technology.
基金supported by Science and Technology Project of China Southern Power Grid Co.,Ltd.(GDKJXM20231259).
文摘This paper develops an innovative computational model for assessing the Carbon Emission Factor(CEF)of provincial power systems that incorporates inter-provincial electricity transfers and hybrid generation portfolios combining conventional and renewable sources.A key contribution lies in evaluating how deep regulation of thermal power plants influence the carbon intensity of coal-fired generation and coal-fired generation together with high penetration renewables.Furthermore,the study quantitatively analyzes the role of renewable energy consumption and the prospective application of Carbon Capture and Storage(CCS)in reducing system-wide CEF.Based on this framework,the paper proposes phased carbon emission targets for Guangdong’s power system for key milestone years(2030,2045,2060),along with targeted implementation strategies.Results demonstrate that in renewable-dominant systems,deep regulation of thermal units,load peak-shaving,and deployment of flexible resources such as energy storage are effective in cutting carbon intensity.To achieve the defined targets—0.367 kg/kWh by 2030,0.231 kg/kWh by 2045,and 0.032 kg/kWh by 2060—the following innovation-focused policy is recommended:in early stage,mainly on expansion of renewable capacity and inter-provincial transmission infrastructure along with energy storage deployment;in mid-term,mainly on enhancement of electricity market mechanisms to promote green power trading and demand-side flexibility;and in late-stage,mainly on systematic retirement of conventional coal assets coupled with large-scale CCS adoption and carbon sink mechanisms.
文摘The world’s most powerful offshore wind turbine has begun feeding electricity into the grid off the coast of southeast China,marking a major technological leap in the country’s wind power industry.The colossal turbine,developed and installed by China Three Gorges Corp.(CTG),is located in the Phase II Liuao offshore wind farm,more than 30 km off the coast of Fujian in waters deeper than 40 metres.The 20-mw unit successfully completed commissioning and started operation on 5 February,CTG announced.
基金supported by the National Natural Science Foundation of China General Program(No.52277106)the Project funded by China Postdoctoral Science Foundation(No.2022M721773).
文摘The large-scale integration of power electronic interface-based renewable energy with intermittency and uncertainty poses severe challenges for power system secure operation,especially frequency security.Determining the system frequency regulation ability under contingency is an open problem.To bridge this gap,a unit commitment(UC)to concentrate solar power considering operational risk and frequency dynamic constraints(RFUC-CSP)is proposed in this paper.A concentrating solar power(CSP)plant with renewable energy characteristics and synchronous units is employed to improve renewable energy utilization and provide frequency support.Firstly,an analytical operational risk model is established to quantify the operational risk under renewable energy integration.Then,the frequency dynamic response characteristic of the system is considered to construct frequency security constraints.A novel RFUC-CSP framework is formulated by incorporating operational risk and frequency security constraints into the UC model,which can allocate operational flexibility of power systems by optimizing the admissible uncertainty level to reduce operational risk.The effectiveness of the proposed RFUC-CSP model is demonstrated by case studies on the modified IEEE 30-bus and IEEE RTS-79 system,and the cost-effectiveness of the CSP plant is quantified.
基金supported by the National Natural Science Foundation of China under Grant 52022016China Postdoctoral Science Foundation under grant 2021M693711Fundamental Research Funds for the Central Universities under grant 2021CDJQY-037.
文摘The rapid development of wind energy in the power sectors raises the question about the reliability of wind turbines for power system planning and operation.The electrical subsystem of wind turbines(ESWT),which is one of the most vulnerable parts of the wind turbine,is investigated in this paper.The hygrothermal aging of power electronic devices(PEDs)is modeled for the first time in the comprehensive reliability evaluation of ESWT,by using a novel stationary“circuit-like”approach.First,the failure mechanism of the hygrothermal aging,which includes the solder layer fatigue damage and packaging material performance degradation,is explained.Then,a moisture diffusion resistance concept and a hygrothermal equivalent circuit are proposed to quantitate the hygrothermal aging behavior.A conditional probability function is developed to calculate the time-varying failure rate of PEDs.At last,the stochastic renewal process is simulated to evaluate the reliability for ESWT through the sequential Monte Carlo simulation,in which failure,repair,and replacement states of devices are all included.The effectiveness of our proposed reliability evaluation method is verified on an ESWT in a 2 MW wind turbine use time series data collected from a wind farm in China.
文摘In real industrial microgrids(MGs),the length of the primary delivery feeder to the connection point of the main substation is sometimes long.This reduces the power factor and increases reactive power absorption along the primary delivery feeder from the external network.Besides,the giant induction electro-motors as the working horse of industries requires remarkable amounts of reactive power for electro-mechanical energy conversions.To reduce power losses and operating costs of the MG as well as to improve the voltage quality,this study aims at providing an insightful model for optimal placement and sizing of reactive power compensation capacitors in an industrial MG.In the presented model,the objective function considers voltage profile and network power factor improvement at the MG connection point.Also,it realizes power flow equations within which all operational security constraints are considered.Various reactive power compensation strategies including distributed group compensation,centralized compensation at the main substation,and distributed compensation along the primary delivery feeder are scrutinized.A real industrial MG,say as Urmia Petrochemical plant,is considered in numerical validations.The obtained results in each scenario are discussed in depth.As seen,the best performance is obtained when the optimal location and sizing of capacitors are simultaneously determined at the main buses of the industrial plants,at the main substation of the MG,and alongside the primary delivery feeder.In this way,74.81%improvement in power losses reduction,1.3%lower active power import from the main grid,23.5%improvement in power factor,and 37.5%improvement in network voltage deviation summation are seen in this case compared to the base case.
基金supported by the Science and Technology Project of Sichuan Electric Power Company“Power Supply Guarantee Strategy for Urban Distribution Networks Considering Coordination with Virtual Power Plant during Extreme Weather Event”(No.521920230003).
文摘Ensuring reliable power supply in urban distribution networks is a complex and critical task.To address the increased demand during extreme scenarios,this paper proposes an optimal dispatch strategy that considers the coordination with virtual power plants(VPPs).The proposed strategy improves systemflexibility and responsiveness by optimizing the power adjustment of flexible resources.In the proposed strategy,theGaussian Process Regression(GPR)is firstly employed to determine the adjustable range of aggregated power within the VPP,facilitating an assessment of its potential contribution to power supply support.Then,an optimal dispatch model based on a leader-follower game is developed to maximize the benefits of the VPP and flexible resources while guaranteeing the power balance at the same time.To solve the proposed optimal dispatch model efficiently,the constraints of the problem are reformulated and resolved using the Karush-Kuhn-Tucker(KKT)optimality conditions and linear programming duality theorem.The effectiveness of the strategy is illustrated through a detailed case study.
基金funded by Youth Talent Growth Project of Guizhou Provincial Department of Education(No.Qianjiaoji[2024]21)National Natural Science Foundation of China(No.62461008 and No.52507211)Guizhou Provincial Key Technology R&D Program(No.[2024]General 049).
文摘To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distribution networks,this paper adopts a component sharing mechanism to propose a composite multi-port hybrid DC circuit breaker(CM-HCB)with DC power flow and fault current limitation abilities,as well as reduced component costs.The proposed CM-HCB topology enables the sharing of the main breaker branch(MB)and the energy dissipation branch,while the load commutation switches(LCSs)in the main branch are reused as power flow control components,enabling flexible regulation of power flow in multiple lines.Meanwhile,by reconstructing the current path during the fault process,the proposed CM-HCB can utilize the internal coupled inductor to limit the current rise rate at the initial stage of the fault,significantly reducing the requirement for breaking current.A detailed study on the topological structure,steady-state power flow regulation mechanism,transient fault isolation mechanism,control strategy and characteristic analysis of the proposed CM-HCB is presented.Then,a Matlab/Simulink-based meshed three-terminal DC grid simulation platform with the proposed CM-HCB is built.The results indicate that the proposed CM-HCB can not only achieve flexible power flow control during steady-state operation,but also obtain current rise limitation and fault isolation abilities under short-circuit fault conditions,verifying its correctness and effectiveness.Finally,a comparative economic analysis is conducted between the proposed CM-HCB and the other two existing solutions,confirming that its component sharing mechanism can significantly reduce the number of components,lower system costs,and improve component utilization.
基金the Deanship of Scientific Research at Northern Border University,Arar,Saudi Arabia,for funding this research work through the project number“NBU-FFR-2025-3623-11”.
文摘Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency deviations,voltage fluctuations,and poor reactive power coordination,posing serious challenges to grid stability.Conventional Interconnection FlowControllers(IFCs)primarily regulate active power flowand fail to effectively handle dynamic frequency variations or reactive power sharing in multi-microgrid networks.To overcome these limitations,this study proposes an enhanced Interconnection Flow Controller(e-IFC)that integrates frequency response balancing and an Interconnection Reactive Power Flow Controller(IRFC)within a unified adaptive control structure.The proposed e-IFC is implemented and analyzed in DIgSILENT PowerFactory to evaluate its performance under various grid disturbances,including frequency drops,load changes,and reactive power fluctuations.Simulation results reveal that the e-IFC achieves 27.4% higher active power sharing accuracy,19.6% lower reactive power deviation,and 18.2% improved frequency stability compared to the conventional IFC.The adaptive controller ensures seamless transitions between grid-connected and islanded modes and maintains stable operation even under communication delays and data noise.Overall,the proposed e-IFCsignificantly enhances active-reactive power coordination and dynamic stability in renewable-integrated multi-microgrid systems.Future research will focus on coupling the e-IFC with tertiary-level optimization frameworks and conducting hardware-in-the-loop validation to enable its application in large-scale smart microgrid environments.
基金supported by the Deanship of Research at the King Fahd University of Petroleum&Minerals,Dhahran,31261,Saudi Arabia,under Project No.EC241001.
文摘Various factors,including weak tie-lines into the electric power system(EPS)networks,can lead to low-frequency oscillations(LFOs),which are considered an instant,non-threatening situation,but slow-acting and poisonous.Considering the challenge mentioned,this article proposes a clustering-based machine learning(ML)framework to enhance the stability of EPS networks by suppressing LFOs through real-time tuning of key power system stabilizer(PSS)parameters.To validate the proposed strategy,two distinct EPS networks are selected:the single-machine infinite-bus(SMIB)with a single-stage PSS and the unified power flow controller(UPFC)coordinated SMIB with a double-stage PSS.To generate data under various loading conditions for both networks,an efficient but offline meta-heuristic algorithm,namely the grey wolf optimizer(GWO),is used,with the loading conditions as inputs and the key PSS parameters as outputs.The generated loading conditions are then clustered using the fuzzy k-means(FKM)clustering method.Finally,the group method of data handling(GMDH)and long short-term memory(LSTM)ML models are developed for clustered data to predict PSS key parameters in real time for any loading condition.A few well-known statistical performance indices(SPI)are considered for validation and robustness of the training and testing procedure of the developed FKM-GMDH and FKM-LSTM models based on the prediction of PSS parameters.The performance of the ML models is also evaluated using three stability indices(i.e.,minimum damping ratio,eigenvalues,and time-domain simulations)after optimally tuned PSS with real-time estimated parameters under changing operating conditions.Besides,the outputs of the offline(GWO-based)metaheuristic model,proposed real-time(FKM-GMDH and FKM-LSTM)machine learning models,and previously reported literature models are compared.According to the results,the proposed methodology outperforms the others in enhancing the stability of the selected EPS networks by damping out the observed unwanted LFOs under various loading conditions.
文摘The use of alternative fuels to generate mechanical and thermal energy in engines is a promising and sought-after technological area with its own unique advantages and characteristics.Consequently,enhancing the technical,economic,and environmental efficiency of gas engines fueled by propane-butane mixture and syngas through optimized operating cycle parameters(including valve timing,ignition timing angle,fuel mixture composition,and compression ratio)is a pressing imperative for scientific and energy sectors.The aim of the study was to investigate and compare the performance of an engine with different compression ratios running on a propane-butane mixture and laboratory syngas.The research’s primary originality lies in its joint study of syngas production technology and the evaluation of the efficiency of a mini power plant fueled by the resulting gas and conventional gas.This article presents a description of the experimental setup,data on measuring instruments,technical characteristics of the mini-power plant,the process for obtaining laboratory syngas,the properties of the gaseous fuels used,and experimental methods.Data on air and fuel consumption,as well as engine efficiency at different compression ratios when running on a propane-butane mixture and syngas,were obtained and analyzed.Converting an engine from a propane-butane mixture to syngas results in a reduction in power of almost 30% and efficiency by 13%–33%.Increasing the compression ratio by 0.9 units causes a rise in maximum efficiency from 0.177 to 0.235 for an engine running on a propane-butane mixture and an increase in maximum efficiency from 0.136 to 0.161 for a syngas engine.It has been confirmed that the compression ratio significantly impacts the technical and economic performance of an engine running on gaseous fuel.The obtained results can be used to modernize existing engines for operation on alternative fuels(syngas)and to design new mini-power plants with promising technical,economic,and environmental characteristics.
文摘The increasing integration of electric vehicle(EV)loads into power systems necessitates understanding their impact on stability.Small-magnitude perturbations,if persistent,can cause low-frequency oscillations,leading to synchronism loss and mechanical stress.This work analyzes the effect of voltage-dependent EV loads on this small-signal stability.The study models an EV load within a Single-Machine Infinite Bus(SMIB)system.It specifically evaluates the influence of EV charging through the DC link capacitor of a Unified Power Flow Controller(UPFC),a key device for damping oscillations.The system’s performance is compared to a modified version equipped with both a UPFC and a Linear Quadratic Regulator(LQR)controller.Results confirm the significant influence of EV charging on the power network.The analysis demonstrates that the best performance is achieved with the SMIB system utilizing the combined UPFC and LQR controller.This configuration effectively dampens low-frequency oscillations,yielding superior results by reducing the system’s rise time,settling time,and peak overshoot.
基金support from the National Science Fund for Distinguished Young Scholars of China(Grant No.62225308)the National Natural Science Foundation of China(Grant No.62473246).
文摘While the instantaneous power of triboelectric nanogenerators(TENGs)has significantly increased,the average power remains unsatisfactory.Achieving a continuous and stable output remains a significant challenge.Herein,a self-excited vibration TENG inspired by woodpeckers is proposed.This structure converts gravitational potential energy into the continuous vibration of a cantilever beam.A dynamic simulation model of the system is established,and the influence of different structural parameters on the motion characteristics and electrical performance is discussed.Meanwhile,the experimental results indicate that the accelerated motion(approximate free-fall motion)is transformed into approximately uniform velocity motion.For a 3 cm^(2) TENG,the instantaneous power density reaches 2.03 W m^(-2),and the average power is 127%higher than that of the conventional cantilever beam mode.The proposed self-excited vibration mechanism is a promising approach for enhancing the average power and operational duration of TENGs.It shows great potential in fluid energy harvesting.
基金supported by Centro de Investigaci on Biom edica en Red Fragilidad y Envejecimiento Saludable(CIBERFES)(Grant Nos.CB16/10/00477,CB16/10/00456,and CB16/10/00464)Plan Propio de Investigaci on of the University of Castilla-La Mancha,and Fondo Europeo de Desarrollo Regional(FEDER)funds from the European Union(Grant No.2022-GRIN-34296)+3 种基金further funded by grants from the Instituto de Salud Carlos III(Grant Nos.PI031558,PI07/90637,PI07/90306,RD 06/0013,and PI18/00972)the Government of Castilla-La Mancha(Grant Nos.03031 and SBPLY/19/180501/000312)Red EXERNETRED DE EJERCICIO FISICO Y SALUD:RED2022-134800T from the Spanish Ministry of Innovation and Sciencesupported by a research grant from the University of Castilla-La Mancha(Programa Investigo,Grant No.2024INVGO-12359)。
文摘Background:Low relative sit-to-stand(STS)power has emerged as a critical predictor of adverse health outcomes,such as frailty and disability,in older adults.However,its impact on falls,fractures,hospitalizations,and all-cause mortality remains unclear.Therefore,this longitudinal study aimed to investigate the potential associations between low relative STS power and these adverse health outcomes in older adults.Methods:A total of 1876 older adults(aged≥65 years,56.4%women)were included from the Toledo Study for Healthy Aging.Relative STS power was assessed using the 30-s STS test and the Alcazar equation.Participants were categorized as having low relative STS power based on previously established cut-off points(2.53 W/kg for men and 2.01 W/kg for women).Falls and fractures(hip and all-type)within the previous year were recorded.Hospitalizations and all-cause mortality were obtained during a follow-up of 6.8±3.1 years(mean±SD;median=7.8 years;interquartile range:3.9-10.1 years)and 9.7±3.5 years(median=10.9 years;interquartile range:8.2-12.5 years),respectively.Generalized linear mixed models,binary logistic regression,and proportional hazards regression adjusted for age,educational level,and comorbidities were used.Results:In men,low relative STS power was significantly associated with an increased likelihood of history of falls(odds ratio(OR)=1.73,95%confidence interval(95%CI):1.08-2.75,p=0.022)and all-type fractures(OR=1.86,95%CI:1.21-2.84,p=0.004)in the previous year.In women,low relative STS power was associated with a higher probability of hip fractures within the previous year(OR=3.25,95%CI:1.07-9.86,p=0.038).Low relative STS power predicted hospitalizations in women(hazard ratio(HR)=1.29,95%CI:1.06-1.58,p=0.012)and longer hospital stays in both men(p=0.020)and women(p=0.033).Low relative STS power significantly increased all-cause mortality in both men(HR=1.57,95%CI:1.26-1.97,p<0.001)and women(HR=2.04,95%CI:1.51-2.74,p<0.001).Conclusion:Low relative STS power was associated with history of hip fractures in women,whereas in men it was associated with history of falls and all-type fractures.Low relative STS power predicted hospitalizations in women but not in men.In both men and women,low relative STS power was associated with longer hospital stays and increased risk of all-cause mortality.
基金supported by the Science and Technology Project of the State Grid Corporation of China“Research on Comprehensive Value Evaluation Method of Flexible Adjusting Resources under Carbon-electricity-certificate Market Coupling Environment”(No.5108-202455038A-1-1-ZN).
文摘The energy transition inspired by carbon neutrality targets and the increasing threat of extreme events raise multi-objective development requirements for power systems.This paper proposes a multi-objective resource allocation model to determine the type,number and location of flexible resources to increase the values of resilience,carbon reduction and renewable energy consumption.To evaluate the values of resilience,a restoration model for transmission systems is established that considers the coordination of fossil-fuel generators,energy storage systems(ESSs)and renewable energy generators in building restoration paths.The collaborative power-carbon-tradable green certificate(TGC)market model is then applied to evaluate the resource values in terms of carbon reduction and renewable energy consumption.Finally,the model is formulated as a mixed-integer linear programming(MILP)with a nonconvex feasible domain,and the normalized normal constraint(NNC)method is applied to obtain approximate Pareto frontiers for decision makers.Case studies validate the effectiveness of the proposed model in improving multi-factor values and analyze the impact of resource regulation capacity on values of restoration and carbon reduction.
基金supported by the National Natural Science Foundation of China(61904089)the Province Natural Science Foundation of Jiangsu(BK20190731).
文摘To improve the theoretical prediction accuracy of static mechanical quantities in MEMS cantilever beams for microwave power detection chips,a distributed static model is proposed based on the deflection equation.An analytical frame-work is established through the precise characterization of cantilever beam bending.The framework can accurately extract key electromechanical parameters,and the correlation between these parameters and geometric changes is systematically studied.Results show that the pull-in voltage increases with the gap but decreases with the length.The predicted pull-in voltage indi-cates a relative error of only 6.5%between the distributed static model and the simulation,which is significantly lower than that of the other two models.The overload power and sensitivity are also analyzed to facilitate performance trade-offs in chip design.The measured return loss varies between-66.46 and-10.56 dB over the 8-12 GHz frequency band,exhibiting a charac-teristic V-shaped trend.Moreover,the measured sensitivity of 66.5 fF/W closely matches the theoretical value of 69.3 fF/W,show-ing a relative error of 5.6%.These findings confirm that the distributed model outperforms the other two in terms of both accu-racy and physical realism,thereby providing important reference for the design of microwave power detection chips.