Study of Suitability of Out-of-Codes Tall Slab-Column and Shearwall Structure 被引量:1
1
作者 GUO Nan ZHAO Tingting LIN Yiying 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2012年第6期1014-1022,共9页
The purpose of this paper is to discuss the suitability of out-of-codes tall slab-column and shearwall structure and to popularize the structure in seismic region.In the research,flat-plate floor was used in slab-colu... The purpose of this paper is to discuss the suitability of out-of-codes tall slab-column and shearwall structure and to popularize the structure in seismic region.In the research,flat-plate floor was used in slab-column and shearwall structure in the practical engineering,the key parameters of slab-column and shearwall structure and frame-shearwall structure such as deflection,punching shear behavior,story drift and capability curve were worked out by static plastic analysis,elastic-plastic time history analysis and pushover analysis,then the suitability of out-of-codes tall slab-column and shearwall structure was evaluated.The results show that the out-of-codes tall slab-column and shearwall structure studies could satisfy the require of deflection and punching shear behavior,the story drift under 7 degree expected rare earthquake waves could satisfy the limit value in the codes and the seismic design spectrum was crossed by the capability curve of the structure and the structure could not collapse.The conclusion is that slab-column and shearwall structure with reasonable design built in Ⅱ soil site of intensity 7 seismic fortification zone can be designed higher than the limit height in the codes. 展开更多
关键词 slab-column and shearwall structure finite element analysis SUITABILITY out-of-codes
在线阅读 下载PDF
某超高层电视塔结构稳定性研究
2
作者 张榕恬 付丹 +1 位作者 方通通 梁峰 《科学技术创新》 2026年第3期165-168,共4页
某电视塔主屋面塔高为325.8 m,为超高层超限结构,主体结构的稳定性设计是结构安全的控制因素之一。本文基于SAP2000有限元分析软件对该塔进行了稳定性分析,分析内容主要包括内外筒水平支撑、内外筒楼板、内外筒梁连接方式、风荷载的分... 某电视塔主屋面塔高为325.8 m,为超高层超限结构,主体结构的稳定性设计是结构安全的控制因素之一。本文基于SAP2000有限元分析软件对该塔进行了稳定性分析,分析内容主要包括内外筒水平支撑、内外筒楼板、内外筒梁连接方式、风荷载的分布方式、初始缺陷等影响因素对结构稳定性的敏感分析;整体结构的特征值屈曲分析以及几何非线性稳定性分析。通过稳定性敏感分析的结果,对结构模型进行了优化,提高了结构的合理性,同时通过结构整体稳定性的数值分析结果,表明在设计荷载作用下,该塔结构具有足够的整体稳定性,具备一定的安全储备。 展开更多
关键词 超高层 超限结构 特征值屈曲分析 非线性稳定性分析 敏感性分析
在线阅读 下载PDF
上海世博中心综合楼项目超限结构抗震设计分析
3
作者 朱揽奇 朱希 《城市建筑》 2026年第4期192-195,共4页
文章以上海世博中心综合楼项目为研究对象,其结构形式为钢框架-中心支撑结构,结构存在扭转不规则、塔楼偏置、楼板局部不连续、侧向刚度不规则等情况。为了实现结构预定的抗震性能目标,首先,采用YJK和ETABS两种计算软件对结构进行多遇... 文章以上海世博中心综合楼项目为研究对象,其结构形式为钢框架-中心支撑结构,结构存在扭转不规则、塔楼偏置、楼板局部不连续、侧向刚度不规则等情况。为了实现结构预定的抗震性能目标,首先,采用YJK和ETABS两种计算软件对结构进行多遇地震作用下的弹性比较计算和时程分析;其次,通过罕遇地震动力弹塑性时程分析,对结构在罕遇地震作用下的响应进行研究;最后,对底层斜柱相交处的复杂节点进行有限元分析。分析结果表明:整体结构有良好的抗震性能,节点在小震及中震工况下均能保持弹性状态,有足够的安全储备。 展开更多
关键词 超限高层结构 超限判别 抗震设计 底层斜柱相交节点 有限元分析
在线阅读 下载PDF
济南某超限高层抗震性能化设计
4
作者 高斌 杨坛 +1 位作者 杜鹏 蒋世林 《工程抗震与加固改造》 北大核心 2026年第1期51-60,共10页
济南舜通大厦为一栋建筑功能多样的高层塔楼,存在扭转不规则、楼板不连续、局部不规则(穿层柱、吊柱),竖向体型收进等情况,属于特别不规则结构,采用框架-核心筒体系。结构抗震设计采用规范规定的性能化设计方法,根据结构重要性提出不同... 济南舜通大厦为一栋建筑功能多样的高层塔楼,存在扭转不规则、楼板不连续、局部不规则(穿层柱、吊柱),竖向体型收进等情况,属于特别不规则结构,采用框架-核心筒体系。结构抗震设计采用规范规定的性能化设计方法,根据结构重要性提出不同的抗震性能目标,对结构进行两种不同力学模型的多遇地震弹性对比分析、弹性时程分析、设防地震验算和罕遇地震作用下的弹塑性时程分析。计算结果表明,通过多种软件计算分析以及采取有针对性的加强措施,结构能够实现既定的性能目标,保证结构的安全及抗震性能。最后,对特殊部位结构设计做相关总结,给出相应的处理措施。 展开更多
关键词 特别不规则结构 高层建筑 超限分析 框架-核心筒结构 性能化设计
在线阅读 下载PDF
某地铁上盖项目超限高层结构的转换层分析
5
作者 张雨 吴磊 +2 位作者 姚亮亮 张红友 彭程 《建筑结构》 北大核心 2026年第3期40-46,共7页
在已投入运营的地铁运用库上建设的某高层剪力墙住宅项目,建筑方案的变动使上部住宅剪力墙与下部转换梁的位置出现偏心,导致受力复杂、传力多级化等问题。对比分析了早期方案与现行新方案的差异,阐述了新方案整体布置对现有运用库的影响... 在已投入运营的地铁运用库上建设的某高层剪力墙住宅项目,建筑方案的变动使上部住宅剪力墙与下部转换梁的位置出现偏心,导致受力复杂、传力多级化等问题。对比分析了早期方案与现行新方案的差异,阐述了新方案整体布置对现有运用库的影响,并梳理了转换梁与转换柱的搭接关系等内容。针对本工程转换结构的特点,重点对比研究了梁板转换与箱形转换两种方案,分析了两种方案下转换梁的弯矩、剪力及位移变化规律。分析结果表明,箱形转换方案中,上、下层楼板可协同工作,共同分担转换梁的内力,且下层楼板的分担作用尤为显著。基于转换梁与巨筒柱的搭接关系、转换梁的应力状态,以及箱形转换下层楼板的有利贡献,最终确定采用箱形转换方案,可为类似转换方案的分析提供借鉴。 展开更多
关键词 地铁上盖项目 超限高层建筑 转换层设计 梁板转换 箱形转换 抗震性能
在线阅读 下载PDF
某非对称双塔连体超限高层结构设计
6
作者 高斌 王传芳 +3 位作者 徐承强 赵倩倩 刘洪国 孙留洋 《建筑结构》 北大核心 2026年第4期44-53,共10页
济南某超限高层建筑体型复杂,存在扭转不规则、楼板不连续、尺寸突变、构件间断及局部不规则等不规则项,属于特别不规则结构,采用框架-剪力墙体系。两侧塔楼通过一道大跨弧形连接体相连,构成非对称双塔连体结构。结构抗震设计采用性能... 济南某超限高层建筑体型复杂,存在扭转不规则、楼板不连续、尺寸突变、构件间断及局部不规则等不规则项,属于特别不规则结构,采用框架-剪力墙体系。两侧塔楼通过一道大跨弧形连接体相连,构成非对称双塔连体结构。结构抗震设计采用性能化设计方法,依据结构重要性设定不同抗震性能目标,对结构开展两种不同力学模型的小震弹性对比分析、中震验算及大震作用下的弹塑性时程分析。结果表明,通过多软件计算分析与针对性加强措施,结构可实现既定性能目标,保障结构安全及抗震性能。同时,对大跨弧形刚性连接体进行全面分析,重点研究大震弹塑性时程下的结构内力、超长不规则结构楼板应力及桁架与主体结构的连接节点,确保结构安全可靠。最后,针对工程中的斜柱,重点完成斜柱的内力分析、节点分析及与斜柱相连的楼面梁板受力分析。 展开更多
关键词 特别不规则结构 非对称双塔连体结构 超限高层建筑 动力弹塑性分析 抗震性能设计 斜柱设计
在线阅读 下载PDF
贵阳某大型商业复杂结构设计
7
作者 魏丰登 吴强 +1 位作者 贾丽娜 郑康 《建筑结构》 北大核心 2026年第4期107-113,共7页
贵阳某大型商业建筑为平面和竖向均不规则的复杂超限高层建筑,结构平面尺寸约为235m×159m,同时存在扭转不规则、楼板不连续、竖向构件不连续等超限项。结合项目特点介绍了结构基础选型;针对抗震不规则,从概念设计、计算分析、抗震... 贵阳某大型商业建筑为平面和竖向均不规则的复杂超限高层建筑,结构平面尺寸约为235m×159m,同时存在扭转不规则、楼板不连续、竖向构件不连续等超限项。结合项目特点介绍了结构基础选型;针对抗震不规则,从概念设计、计算分析、抗震构造等几个方面采取了优化结构布置、加强计算校核、提高抗震等级等措施,采用性能化设计以确保结构达到预定的抗震性能目标。对工程中重难点如结构超长、大跨人行连桥、室内110m长悬挂螺旋天梯、V形巨柱等进行了深入分析研究,提出了合理的解决方案,包括连桥设置调谐质量阻尼器有效改善舒适度、采用多道支撑结构保证螺旋天梯的整体稳定、通过防倒塌分析确保V形巨柱的结构安全等,并通过工程实践验证了设计的可行性和可靠性。 展开更多
关键词 复杂结构 超限高层建筑 超长结构 大跨结构 超长螺旋天梯 V形巨柱 调谐质量阻尼器 舒适度
在线阅读 下载PDF
海南某塔楼偏置超限高层结构设计
8
作者 何忻炜 《工程建设与设计》 2026年第1期10-12,共3页
某图书馆项目为高层建筑,建筑高87.05 m,采用钢筋混凝土框架-核心筒结构体系。结构存在塔楼偏置、大底盘多塔、楼板大开洞等多项不规则特征,为超限高层结构。结合项目所在地低烈度、高风压的基本情况,针对本工程结构设计中的重难点与特... 某图书馆项目为高层建筑,建筑高87.05 m,采用钢筋混凝土框架-核心筒结构体系。结构存在塔楼偏置、大底盘多塔、楼板大开洞等多项不规则特征,为超限高层结构。结合项目所在地低烈度、高风压的基本情况,针对本工程结构设计中的重难点与特殊性,设计方案采取了3项核心加强措施:在结构计算模型中实施风荷载多方向输入的精细化分析,加大结构外围抗侧力构件的截面尺寸,强化塔楼偏置对应楼层的抗水平力能力。经全面系统分析验证,该项目所采用的结构体系科学合理,各项性能指标均符合国家现行规范要求并具备充足的安全余量,整体结构具有良好的抗震、抗风性能。 展开更多
关键词 超限高层结构 塔楼偏置 框架-核心筒结构
在线阅读 下载PDF
某公寓办公楼多遇地震弹性分析及结构性能研究
9
作者 陈波 鄞木 《建筑技术开发》 2026年第2期80-83,共4页
小震弹性分析作为抗震设计的重要手段,能够评估结构在小震作用下的弹性响应,为结构设计提供关键依据。研究以深圳某超限高层公寓办公楼为研究对象,基于相关规范,阐述其多遇地震弹性分析过程及结果,深入探讨建筑结构在小震作用下的性能... 小震弹性分析作为抗震设计的重要手段,能够评估结构在小震作用下的弹性响应,为结构设计提供关键依据。研究以深圳某超限高层公寓办公楼为研究对象,基于相关规范,阐述其多遇地震弹性分析过程及结果,深入探讨建筑结构在小震作用下的性能表现。通过对该建筑结构体系、分析参数、整体指标、各构件响应等方面的研究,验证结构设计的合理性与安全性,可为超限高层建筑抗震设计提供参考依据。 展开更多
关键词 超限高层建筑 小震弹性分析 抗震设计 时程分析
在线阅读 下载PDF
Investigating Earth Reaction to Pull-Out Process of Frictional Rock Bolts Using Distinct Element Method
10
作者 Mohammad Sadegh Ayyoobi Arash Refahi 《Open Journal of Geology》 2020年第8期851-862,共12页
The reaction of earth to pull-out process of frictional rock bolts was here modeled by the distinct element method (DEM). Ten frictional bolts were prepared;the expanding shells of five bolts included convex edges and... The reaction of earth to pull-out process of frictional rock bolts was here modeled by the distinct element method (DEM). Ten frictional bolts were prepared;the expanding shells of five bolts included convex edges and the others had the shells with concave bits. The strength of bolts was measured by applying a standard pull-out test;the results confirmed that the strength of shells with convex edges was remarkably more than the strength of other shells. Furthermore, a two-dimensional DEM model of the test was developed by a particle flow code;the obtained results showed that the reaction of rock particles to the contacts occurring between the convex edges and earth was considerably more than those of the concave bits. In the other words, the convex edges transferred the pull-out force into a large area of the surrounded rock, causing these bolts to have the highest resistance against earth movements. 展开更多
关键词 Frictional Rock Bolt Pull-out Test Distinct Element Method Particle Flow code
在线阅读 下载PDF
嘉善某文化中心超限高层结构设计 被引量:1
11
作者 蒋涛 王凯 《广东土木与建筑》 2025年第1期77-81,91,共6页
嘉善某文化中心高层建筑采用清水混凝土框架-剪力墙结构,存在剪力墙超长、平立面不规则等不规则因素,属于超限高层建筑。采用YJK对结构进行了多遇地震、设防地震作用下的等效弹性分析,采用ETABS进行了模型对比分析,采用SAUSAGE进行了罕... 嘉善某文化中心高层建筑采用清水混凝土框架-剪力墙结构,存在剪力墙超长、平立面不规则等不规则因素,属于超限高层建筑。采用YJK对结构进行了多遇地震、设防地震作用下的等效弹性分析,采用ETABS进行了模型对比分析,采用SAUSAGE进行了罕遇地震下的动力弹塑性时程分析。分析结果表明,结构各向指标均满足预期设定的抗震性能目标,关键构件采取相应的抗震加强措施,以确保大震下的安全性能。 展开更多
关键词 超限高层结构 清水混凝土 弹塑性时程分析 性能指标
在线阅读 下载PDF
某平面凹凸不规则且带错层和通高墙的超限高层建筑结构设计 被引量:3
12
作者 施尽波 黄桂新 +1 位作者 练有为 邱伟亮 《山西建筑》 2025年第3期61-66,共6页
针对某平面凹凸不规则且带错层和通高墙的超限高层建筑结构,首先分析了结构在小震和风荷载作用下的各项指标;其次对凹凸不规则弱连接处楼板应力进行了详细分析;再次对错层处剪力墙设计、底部通高墙体平面外计算长度进行了重点分析;最后... 针对某平面凹凸不规则且带错层和通高墙的超限高层建筑结构,首先分析了结构在小震和风荷载作用下的各项指标;其次对凹凸不规则弱连接处楼板应力进行了详细分析;再次对错层处剪力墙设计、底部通高墙体平面外计算长度进行了重点分析;最后采用大震弹塑性时程分析方法验算了结构薄弱层层间塑性位移角。分析结果表明:对于单肢正交形式的凹凸不规则结构,应加强单肢与中心区连接范围的楼板厚度及配筋,中震作用下,楼板满足钢筋抗拉弹性,混凝土抗剪不屈服;中震作用下,错层处剪力墙会受到上下层楼面错位而产生的平面外和平面内附加剪力及弯矩,墙肢段竖向配筋应取平面外和平面内计算结果的包络值;通高墙体平面外计算长度不能盲目套用规范计算公式,应从结构整体来考察其计算长度;对于平面凹凸不规则的复杂超限高层建筑,应采用弹性动力时程补充验算层间位移角是否满足规范要求。 展开更多
关键词 凹凸不规则 超限高层结构 错层 通高墙 弹塑性时程分析
在线阅读 下载PDF
某分叉斜撑转换超限结构抗震设计
13
作者 郭朋 王松帆 肖杰 《建筑结构》 北大核心 2025年第16期11-16,共6页
汕尾某酒店采用分叉斜撑转换结构体系,属于超限高层建筑,且存在扭转不规则、凹凸不规则、局部楼板不连续、尺寸突变及局部不规则5项超限情况。采用YJK和ETABS两种分析软件对结构进行了小震反应谱和弹性时程分析,补充了中震、大震等效弹... 汕尾某酒店采用分叉斜撑转换结构体系,属于超限高层建筑,且存在扭转不规则、凹凸不规则、局部楼板不连续、尺寸突变及局部不规则5项超限情况。采用YJK和ETABS两种分析软件对结构进行了小震反应谱和弹性时程分析,补充了中震、大震等效弹性分析,并采用PERFORM-3D软件进行了罕遇地震动力弹塑性时程分析;另外采用ANSYS补充了分叉斜撑节点分析。结果表明,结构整体和各构件的抗震性能均能达到设计的预期目标。 展开更多
关键词 超限高层建筑 分叉斜撑 转换斜撑 抗震性能化设计 节点分析
在线阅读 下载PDF
杭州秦望广场项目T2塔楼超高层结构抗震设计与分析 被引量:1
14
作者 谢艳花 黄子贶 王秀泉 《工程建设与设计》 2025年第7期19-22,共4页
杭州秦望广场项目T2塔楼采用框架-核心筒结构,屋面高度为205.20 m,为B级高度建筑,同时存在扭转不规则、裙房偏心率大于0.15、楼板不连续、斜柱四项不规则,需要进行超限设计。论文对该结构进行了小震、中震和大震作用下的结构分析,分析... 杭州秦望广场项目T2塔楼采用框架-核心筒结构,屋面高度为205.20 m,为B级高度建筑,同时存在扭转不规则、裙房偏心率大于0.15、楼板不连续、斜柱四项不规则,需要进行超限设计。论文对该结构进行了小震、中震和大震作用下的结构分析,分析结果表明,整体结构能满足预先提出的性能目标要求。针对不规则项,针对性地采取了抗震构造措施,以保证结构安全。 展开更多
关键词 框架-核心筒结构 B级高度 超限 性能目标
在线阅读 下载PDF
城市更新项目超限高层建筑抗震设计关键点 被引量:1
15
作者 邹积成 《工程建设与设计》 2025年第24期10-12,共3页
围绕深圳市龙华区大浪街道英泰工业中心城市更新项目进行了简单介绍,先进行了抗震参数设计、抗震性能评估,提出应关注施工材料选择与检查,选择高强度材料,以保证建筑性能,后续就抗震结构布置与选型、抗震结构加强等展开了深入探讨。
关键词 城市更新项目 超限高层建筑 抗震设计
在线阅读 下载PDF
Q690高强中空夹层钢管混凝土柱抗震性能试验研究 被引量:1
16
作者 贺育明 《电力勘测设计》 2025年第7期63-73,共11页
为研究Q690高强钢应用于中空夹层钢管混凝土结构的抗震性能,促进工程结构轻质高强化发展,对具有超限径厚比的圆套圆高强中空夹层钢管混凝土柱进行低周往复加载试验,研究空心率(χ=0.54~0.82)、轴压比(n=0.1~0.3)及填充材料类别(混凝土、... 为研究Q690高强钢应用于中空夹层钢管混凝土结构的抗震性能,促进工程结构轻质高强化发展,对具有超限径厚比的圆套圆高强中空夹层钢管混凝土柱进行低周往复加载试验,研究空心率(χ=0.54~0.82)、轴压比(n=0.1~0.3)及填充材料类别(混凝土、ECC)对抗震性能的影响规律。结果表明:增大轴压比和空心率会显著降低钢管混凝土柱脚的滞回性能、承载力和延性,其中ECC材料试件较普通混凝土试件表现更差。总体上,合理控制轴压比、空心率及径厚比时Q690高强中空夹层钢管混凝土柱可以表现出良好的滞回性能,可为其在海上风电支撑结构、导管架平台及高桩码头等工程的应用提供有益的参考依据。 展开更多
关键词 高强中空夹层钢管混凝土柱 Q690高强钢 超限径厚比 破坏模式 抗震性能
在线阅读 下载PDF
北京歇甲车辆段上盖结构设计
17
作者 金云飞 白记东 +3 位作者 徐琛 刘郁 叶飞 靳天伟 《建筑结构》 北大核心 2025年第7期48-56,共9页
在北京地铁17号线歇甲车辆段工程中,采用层间隔震技术,底盘原隔震层设置于二层顶,隔震层以下结构采用框架-剪力墙结构体系。盖上住宅采用剪力墙结构体系。对本项目中的运用库及检修库范围的减震进行了介绍。通过对三种优化方案的分析对... 在北京地铁17号线歇甲车辆段工程中,采用层间隔震技术,底盘原隔震层设置于二层顶,隔震层以下结构采用框架-剪力墙结构体系。盖上住宅采用剪力墙结构体系。对本项目中的运用库及检修库范围的减震进行了介绍。通过对三种优化方案的分析对比,最终采用隔震层下移至首层顶方案。结合工程特点以及超限高层抗震审查意见制定了性能化目标,针对性能化目标对结构进行计算分析,重点进行了结构的动力特性、隔震设计、转换梁设计以及大震弹塑性分析。并进行了四项专项分析:型钢混凝土组合墙设计、隔震层转换方案对比、转换梁设计竖向地震取值、咽喉区五和七结构减振措施。分析结果表明,本结构体系安全可行,满足抗震性能目标。 展开更多
关键词 车辆段 隔震设计 结构选型与优化 超限结构 转换层
在线阅读 下载PDF
北京朝阳站南侧大型商业中心结构设计
18
作者 刘华 卢清刚 +5 位作者 石异 呼延辰昭 史炎升 閤东东 张颖 高晗 《建筑结构》 北大核心 2025年第19期48-52,共5页
某大型商业中心采用钢结构体系,平面布置复杂,为营造通透空间,商业动线设置较多中庭洞口,并要求公区不露柱,结构形成了楼板多处开洞、大跨度、大悬挑等平面不规则情况;商业建筑竖向功能复杂,含有中庭、影院、露台、天窗等多种功能的竖... 某大型商业中心采用钢结构体系,平面布置复杂,为营造通透空间,商业动线设置较多中庭洞口,并要求公区不露柱,结构形成了楼板多处开洞、大跨度、大悬挑等平面不规则情况;商业建筑竖向功能复杂,含有中庭、影院、露台、天窗等多种功能的竖向变化,使结构形成穿层柱、斜柱等竖向不规则情况。在满足商业建筑相关需求条件下,在有限范围内设置加强措施,避免结构超限。对悬挑梁、大跨度次梁、组合梁及高强钢的使用进行了分析研究,对比了其承载力、变形、舒适度及经济性指标。结果表明结构设计经济、安全、合理。 展开更多
关键词 超限结构设计 悬挑梁 大跨度次梁 组合梁 高强钢
在线阅读 下载PDF
大商东港乐园超限连体高层结构设计与分析
19
作者 邱韶光 宋莉 +3 位作者 赵亮 张伟 叶华静 张振平 《建筑结构》 北大核心 2025年第15期8-13,共6页
大商东港乐园项目地上包括3栋超高层塔楼及4栋裙房。1号楼结构高度209m,为超B级高度高层建筑;2、3号楼在连体以下结构高度126.35m,均为B级高度高层建筑,1~3号楼在结构标高126.35~149.80高度通过两个连接体连为一体,形成高位连体结构。1... 大商东港乐园项目地上包括3栋超高层塔楼及4栋裙房。1号楼结构高度209m,为超B级高度高层建筑;2、3号楼在连体以下结构高度126.35m,均为B级高度高层建筑,1~3号楼在结构标高126.35~149.80高度通过两个连接体连为一体,形成高位连体结构。1号楼为钢筋混凝土框架-核心筒结构,存在扭转、偏心布置、局部夹层、连体结构等不规则项;2、3号楼为钢筋混凝土剪力墙结构,存在扭转、刚度突变、承载力突变、连体结构以及局部存在穿层墙、穿层柱等不规则项。针对项目特点及构件的重要性,设定合适的抗震性能目标。采用多种软件对结构进行多遇地震、设防地震及罕遇地震分析。根据分析结果,对结构薄弱部位采取相应的加强措施,使结构达到预期的抗震性能目标,基于动力弹塑性时程分析,复核连接体在滑动支座处的竖向力及位移。对连接体关键部位应力、变形、防连续倒塌等进行了补充分析,结果表明,结构具备较好的抗震性能及抗连续倒塌能力。 展开更多
关键词 连体结构 超限高层结构 抗震性能目标 动力弹塑性分析 滑动支座 防连续倒塌
在线阅读 下载PDF
福州长乐国际机场交通中心复杂结构设计研究
20
作者 耿伟 束伟农 +3 位作者 陈林 王翰墨 张歆宇 常虹 《建筑结构》 北大核心 2025年第19期1-7,共7页
福州长乐国际机场交通中心(GTC)是集轨道交通、商业、地空换乘于一体的复杂超限高层建筑,其结构设计面临抗震性能、超长混凝土裂缝控制及轨道交通共构等多项技术挑战。系统阐述了GTC的结构体系、抗震设计策略及创新技术应用。GTC结构采... 福州长乐国际机场交通中心(GTC)是集轨道交通、商业、地空换乘于一体的复杂超限高层建筑,其结构设计面临抗震性能、超长混凝土裂缝控制及轨道交通共构等多项技术挑战。系统阐述了GTC的结构体系、抗震设计策略及创新技术应用。GTC结构采用防屈曲约束支撑(BRB)+混凝土框架体系、弦支拱壳及桁架组合钢结构屋盖构成的混合结构体系,通过弹塑性时程分析、地空一体化沉降控制分析等精细化数值模拟,验证了罕遇地震作用下结构的安全性与经济性,以及上部结构对轨道工后沉降影响的可控性。研究结果表明:采用BRB显著提升了结构的耗能能力,支承屋盖的型钢混凝土柱在中震作用下保持弹性,大震损伤因子低于03。屋盖采用弦支拱壳结构,实现了建筑美学与结构受力性能的高度统一。超长混凝土结构通过设置加宽后浇带与补偿收缩技术等有效抑制了温度裂缝。 展开更多
关键词 福州长乐国际机场 复杂超限高层结构 防屈曲约束支撑 弦支拱壳结构 抗震性能 沉降控制
在线阅读 下载PDF