Inverse heat conduction method (IHCM) is one of the most effective approaches to obtaining the boiling heat transfer coefficient from measured results. This paper focuses on its application in cryogenic boiling heat t...Inverse heat conduction method (IHCM) is one of the most effective approaches to obtaining the boiling heat transfer coefficient from measured results. This paper focuses on its application in cryogenic boiling heat transfer. Experiments were conducted on the heat transfer of a stainless steel block in a liquid nitrogen bath, with the assumption of a 1D conduction condition to realize fast acquisition of the temperature of the test points inside the block. With the inverse-heat conduction theory and the explicit finite difference model, a solving program was developed to calculate the heat flux and the boiling heat transfer coefficient of a stainless steel block in liquid nitrogen bath based on the temperature acquisition data. Considering the oscillating data and some unsmooth transition points in the inverse-heat-conduction calculation result of the heat-transfer coefficient, a two-step data-fitting procedure was proposed to obtain the expression for the boiling heat transfer coefficients. The coefficient was then verified for accuracy by a comparison between the simulation results using this expression and the verifying experimental results of a stainless steel block. The maximum error with a revised segment fitting is around 6%, which verifies the feasibility of using IHCM to measure the boiling heat transfer coefficient in liquid nitrogen bath.展开更多
[Objective] The research aimed to study the determination of 16 kinds of OCPs in water by liquid-liquid extraction -GC. [Method] The new method for determining 16 kinds of OCPs in water by liquid-liquid extraction -GC...[Objective] The research aimed to study the determination of 16 kinds of OCPs in water by liquid-liquid extraction -GC. [Method] The new method for determining 16 kinds of OCPs in water by liquid-liquid extraction -GC was established, and the influencing factors such as nitrogen pressure and water bath temperature were discussed. [ Result] Detection limit of the method was from 3.2 to 14.1 ng/L, the relative standard deviation was between 4.0% and 9.6%, and the average recovery ranged from 80.8% to 106.0%. By optimizing nitrogen pressure and water bath temperature in the sample pretreatment process, when nitrogen pressure was +0.087 kPa, and water bath temperature was ±36 ℃, recovery effect of this method was better. [ Conclusion] The determination method had accurate qualitative and quantitative results, and met detection requirement of 16 kinds of OCPs in water.展开更多
基金supported by the National Natural Sciences Foundation of China (No. 50776075)
文摘Inverse heat conduction method (IHCM) is one of the most effective approaches to obtaining the boiling heat transfer coefficient from measured results. This paper focuses on its application in cryogenic boiling heat transfer. Experiments were conducted on the heat transfer of a stainless steel block in a liquid nitrogen bath, with the assumption of a 1D conduction condition to realize fast acquisition of the temperature of the test points inside the block. With the inverse-heat conduction theory and the explicit finite difference model, a solving program was developed to calculate the heat flux and the boiling heat transfer coefficient of a stainless steel block in liquid nitrogen bath based on the temperature acquisition data. Considering the oscillating data and some unsmooth transition points in the inverse-heat-conduction calculation result of the heat-transfer coefficient, a two-step data-fitting procedure was proposed to obtain the expression for the boiling heat transfer coefficients. The coefficient was then verified for accuracy by a comparison between the simulation results using this expression and the verifying experimental results of a stainless steel block. The maximum error with a revised segment fitting is around 6%, which verifies the feasibility of using IHCM to measure the boiling heat transfer coefficient in liquid nitrogen bath.
文摘[Objective] The research aimed to study the determination of 16 kinds of OCPs in water by liquid-liquid extraction -GC. [Method] The new method for determining 16 kinds of OCPs in water by liquid-liquid extraction -GC was established, and the influencing factors such as nitrogen pressure and water bath temperature were discussed. [ Result] Detection limit of the method was from 3.2 to 14.1 ng/L, the relative standard deviation was between 4.0% and 9.6%, and the average recovery ranged from 80.8% to 106.0%. By optimizing nitrogen pressure and water bath temperature in the sample pretreatment process, when nitrogen pressure was +0.087 kPa, and water bath temperature was ±36 ℃, recovery effect of this method was better. [ Conclusion] The determination method had accurate qualitative and quantitative results, and met detection requirement of 16 kinds of OCPs in water.