期刊文献+
共找到2,304篇文章
< 1 2 116 >
每页显示 20 50 100
Edmund Becher Wilson's Early Contributions to the Chromosome Theory of Heredity: A Case Study of Instrumentalism in Science
1
作者 Lilian Al-Chueyr Pereira Martins 《Journal of Philosophy Study》 2015年第9期431-443,共13页
The chromosome theory of inheritance was established during the three first decades of the 20th century. During the early stage of its substantiating, there were lots of puzzles and little evidence that could validate... The chromosome theory of inheritance was established during the three first decades of the 20th century. During the early stage of its substantiating, there were lots of puzzles and little evidence that could validate it. The cytological processes were obscure and several scientists maintained serious doubts concerning the existence of a connection between Mendel's principles and the behaviour of chromosomes during cell division. It was vital to associate an external, observable characteristic of the organism to a specific chromosome, and this was achieved when sex was connected to special chromosomes. At that time, however, some important scholars refused to accept or delayed acceptance of the conception that the hereditary factors (later called genes) were physical entities located along the chromosomes. Such was the case of Thomas Morgan (1866-1945) and William Bateson (186 I- 1926). Their attitudes could be explained by considering the doubtful ground of the hypothesis at that time. It is more difficult, however, to understand the attitude of Edmund Beecher Wilson (1856-1939). Being an expert in cytology he was acquainted with all the difficulties concerning the chromosome hypothesis. Nonetheless, from 1905 onward, he attributed little weight to the problems and dedicated a notable effort to obtaining evidence that could have grounded it. This paper analyses Wilson's attitude focusing on his studies from 1900 to 1915 and the scientific context of this period. This study led to the conclusion that Wilson's attitude could be explained in methodological terms by the adoption of an instrumentalist attitude, while Bateson and Morgan adopted a realistic perspective. 展开更多
关键词 history of genetics philosophy of biology chromosome hypothesis/theory WILSON Edmund Beecher instrumentalism
在线阅读 下载PDF
Philosophical Analysis of the Implications of John Dewey’s Instrumentalism on Entrepreneurial Development
2
作者 Raphael Olisa Maduabuchi Anthony Chukwuemeka Nwafor 《Journal of Philosophy Study》 2021年第5期334-342,共9页
This work sought to examine the philosophical arguments of John Dewey’s theory of knowledge for practical gains.Hence,it sought to address the problem on how the current rave of entrepreneurship can be given a new di... This work sought to examine the philosophical arguments of John Dewey’s theory of knowledge for practical gains.Hence,it sought to address the problem on how the current rave of entrepreneurship can be given a new direction,especially from the perspective of ideas or theories matching with practice as inspired by Dewey’s instrumentalism.The method of conceptual and critical analysis,hermeneutics and inductive/deductive arguments are employed to achieve that aim.The major findings of the work are that entrepreneurial development must be engaged from an interdisciplinary matrix.Thus,this work is geared to translate John Dewey’s philosophy to business sustainability,management and gains. 展开更多
关键词 ENTREPRENEURSHIP instrumentalism HERMENEUTICS INDUCTIVE deductive and business
在线阅读 下载PDF
The Mini-SiTian Array:First-two-year Operation 被引量:3
3
作者 Min He Hong Wu +70 位作者 Liang Ge Jianfeng Tian Zheng Wang Haiyang Mu Yu Zhang Yang Huang Jie Zheng Zhou Fan Zhengyang Li Hongrui Gu Henggeng Han Kai Xiao Zhirui Li Junjie Jin Beichuan Wang Jun Ma Jinhang Zou Ying Wu Jiupeng Guo Liguo Fang Zhigang Hou Bowen Zhang Yunfei Xu Yiming Mao Shuai Liu Fangzhou Ren Cunshi Wang Xue Li Yongxin Wu Chuanjie Zheng Yiyang Lin Shunxuan He Kun Xu Yinan Zhu Zhijun Tu Xinlin Zhao Yongkang Sun Hua Bao Xueang Sun Yingzhen Cui Lanya Mou Ruifeng Shi Jinghang Shi Xunhao Chen Yuliang Hong Haomiao Huang Zikun Lin Zeyang Pan Ruining Zhao Yingjie Cai Rui Wang Junbo Zhang Jinhu Wang Wan Zhou Shengming Li Jing Ren Xiaohan Chen Xiangyu Li Liyue Zhang Hao Mo Yuyang Zhou Jiahui Wang Buhui Lv Zhaohui Shang Yunning Zhao Jinlei Zhang Yue Sun Xiaopeng Liu Zijian Han Yongna Mao Jifeng Liu 《Research in Astronomy and Astrophysics》 2025年第4期43-54,共12页
The Si Tian project,designed to utilize 60 telescopes distributed across multiple sites in China,is a next-generation timedomain survey initiative.As a pathfinder for the Si Tian project,the Mini-Si Tian(MST)has been ... The Si Tian project,designed to utilize 60 telescopes distributed across multiple sites in China,is a next-generation timedomain survey initiative.As a pathfinder for the Si Tian project,the Mini-Si Tian(MST)has been proposed and implemented to test the Si Tian’s brain and data pipeline,and to evaluate the feasibility of its technology and science cases.Mounted at the Xinglong Observatory,the MST project comprises three 30 cm telescopes and has been operated since 2022 November.Each telescope of the MST possesses a large field of view,covering 2°.29×1°.53 FOV,and is equipped withg',r'andi'filters,respectively.Acting as the pioneer of the forthcoming Si Tian project,the MST is dedicated to the discovery of variable stars,transients,and outburst events,and has already obtained some interesting scientific results.In this paper,we will summarize the first-two-year operation of the MST project. 展开更多
关键词 surveys telescopes instrumentation:photometers
在线阅读 下载PDF
Design of Readout and Characterization System for Multi-pixel Superconducting Terahertz MKIDs 被引量:1
4
作者 Jia-Wen Zhang Zhen-Hui Lin +3 位作者 Jie Hu Wei Geng Jing Li Sheng-Cai Shi 《Research in Astronomy and Astrophysics》 2025年第4期150-158,共9页
The proposed design of a microwave superconducting kinetic inductance detector(MKID)array readout system characterizes the performance of MKIDs through a digital homodyne frequency mixing architecture.Meanwhile,the re... The proposed design of a microwave superconducting kinetic inductance detector(MKID)array readout system characterizes the performance of MKIDs through a digital homodyne frequency mixing architecture.Meanwhile,the readout system is implemented using a frequency division multiplexing circuit system,coupled with an FFT design to enable the readout of MKID arrays.The system is characterized by its compact size,low cost,portability,and ease of further development.Together,these features have significant implications for the design and readout of terahertz MKID arrays,while simultaneously advancing both the theoretical and practical aspects of MKID technology. 展开更多
关键词 Astronomical Instrumentation Methods and Techniques instrumentation:detectors methods:observational
在线阅读 下载PDF
Expert consensus on management of instrument separation in root canal therapy 被引量:1
5
作者 Yi Fan Yuan Gao +33 位作者 Xiangzhu Wang Bing Fan Zhi Chen Qing Yu Ming Xue Xiaoyan Wang Zhengwei Huang Deqin Yang Zhengmei Lin Yihuai Pan Jin Zhao Jinhua Yu Zhuo Chen Sijing Xie He Yuan Kehua Que Shuang Pan Xiaojing Huang Jun Luo Xiuping Meng Jin Zhang Yi Du Lei Zhang Hong Li Wenxia Chen Jiayuan Wu Xin Xu Jing Zou Jiyao Li Dingming Huang Lei Cheng Tiemei Wang Benxiang Hou Xuedong Zhou 《International Journal of Oral Science》 2025年第3期301-313,共13页
Instrument separation is a critical complication during root canal therapy,impacting treatment success and long-term tooth preservation.The etiology of instrument separation is multifactorial,involving the intricate a... Instrument separation is a critical complication during root canal therapy,impacting treatment success and long-term tooth preservation.The etiology of instrument separation is multifactorial,involving the intricate anatomy of the root canal system,instrument-related factors,and instrumentation techniques.Instrument separation can hinder thorough cleaning,shaping,and obturation of the root canal,posing challenges to successful treatment outcomes.Although retrieval of separated instrument is often feasible,it carries risks including perforation,excessive removal of tooth structure and root fractures.Effective management of separated instruments requires a comprehensive understanding of the contributing factors,meticulous preoperative assessment,and precise evaluation of the retrieval difficulty.The application of appropriate retrieval techniques is essential to minimize complications and optimize clinical outcomes.The current manuscript provides a framework for understanding the causes,risk factors,and clinical management principles of instrument separation.By integrating effective strategies,endodontists can enhance decision-making,improve endodontic treatment success and ensure the preservation of natural dentition. 展开更多
关键词 root canal therapy instrument separation retrieval techniques tooth preservation root canal therapyimpacting endodontic treatment success root canal root canalposing
暂未订购
Preliminary solution to parameters for WFST
6
作者 Yuxi Jiang Fan Li +4 位作者 Jian Chen Bin Li Tianrui Sun Yantian Zhu Xin Wang 《中国科学技术大学学报》 北大核心 2025年第4期14-22,13,I0001,共11页
The Wide Field Survey Telescope(WFST)is located at 4200 m on Saishiteng Mountain in Lenghu,Qinghai Province,China.It features a primary mirror with a diameter of 2.5 m and a camera equipped with nine CCDs,providing a ... The Wide Field Survey Telescope(WFST)is located at 4200 m on Saishiteng Mountain in Lenghu,Qinghai Province,China.It features a primary mirror with a diameter of 2.5 m and a camera equipped with nine CCDs,providing a wide field of view of approximately 3×3 square degrees.Calibration parameters are essential to ensure the precision of astrometric observations with the WFST.These parameters are derived from geometric distortion(GD)and gaps through astrometric modeling and are subsequently validated via the Yao’An High Precision Telescope(YAHPT).The GD solutions show maximum distortions between 1.18 and 10.29 pixels for the WFST chips,with central chips exhibiting lower distortion.After applying the GD correction,the precision of the WFST reaches 4 mas.The interchip gaps of the WFST range from 1.922 mm to 7.765 mm,corresponding to 10μm/pixel,aligning with the design and measurements.The calibrated parameters guarantee that the WFST can perform highly accurate astrometric measurements.Furthermore,as the WFST undergoes updates,the parameter model remains consistently applicable. 展开更多
关键词 astronomical instrumentation ASTROMETRY astronomy data analysis astronomy data reduction image processing
在线阅读 下载PDF
Accuracy verification and practice of simultaneous thermal analyzer
7
作者 LI Haixia YANG Xiuhong +2 位作者 TIAN Liyan LUO Minting GUO Yanwen 《实验技术与管理》 北大核心 2025年第11期133-139,共7页
The accuracy of thermal analysis measurements is critical to analyze material properties correctly,making the improvement of measurement precision and proper uncertainty analysis of test results absolutely essential.A... The accuracy of thermal analysis measurements is critical to analyze material properties correctly,making the improvement of measurement precision and proper uncertainty analysis of test results absolutely essential.As a primary thermal analysis instrument,the simultaneous thermal analyzer(STA)has unique advantages,which combines the functionalities of thermogravimetric(TG)analyzersand differential scanning calorimeters(DSC).However,the absence of standard quality control procedures has resulted in poor measurement reproducibility,low accuracy,and inadequate traceability of analytical results.This study utilized a multi-point temperature calibration method based on national certified reference materials to reduce instrument temperature indication errors.On this basis,we innovatively established a comprehensive quality control system encompassing laboratory environmental control,standard method selection,instrument performance verification,reference material traceability,and uncertainty analysis,thereby achieving standardized operational procedures for thermal analysis measurement.Taking the"determination of initial melting temperature of unknown substances"as a representative case study,a component resolution model for thermal analysis test uncertainty was developed.Through systematic analysis of both the reference material-introduced component and measurement repeatability component,complete traceability of test results was achieved.This approach ensures data validity and enhances the accuracy of test results.This provides crucial technical support and practical reference for the standardization of thermal analysis measurement procedure and assessment of result reliability. 展开更多
关键词 thermal analysis accuracy simultaneous thermal analyzer standardized testing procedures instrument performance qualification method selection traceability analysis uncertainty analysis
在线阅读 下载PDF
Energy and Buildings
8
《建筑节能(中英文)》 2025年第6期100-100,共1页
https://www.sciencedirect.com/journal/energy-and-buildings/vol/336/suppl/C Volume 336,1 June 2025[OA](1)Advancing energy renovations through digitalisation:A critical review of EU policies and instruments by Sun-Ah Hw... https://www.sciencedirect.com/journal/energy-and-buildings/vol/336/suppl/C Volume 336,1 June 2025[OA](1)Advancing energy renovations through digitalisation:A critical review of EU policies and instruments by Sun-Ah Hwang,Sultan etin,Henk Visscher,et al,Article 115627. 展开更多
关键词 eu policies instruments EU policies digitalisation energy renovations INSTRUMENTS
在线阅读 下载PDF
The Erhu: A Journey Through Chinese Music
9
作者 郭子升 《疯狂英语(双语世界)》 2025年第3期77-77,共1页
When we learn about Chinese traditional culture,we can find many interesting things.One of them is a special musical instrument—Erhu.The Erhu is a two-stringed instrument played with a bow.People often call it the Ch... When we learn about Chinese traditional culture,we can find many interesting things.One of them is a special musical instrument—Erhu.The Erhu is a two-stringed instrument played with a bow.People often call it the Chinese violin or Chinese fiddle.It is one of the most famous and loved instruments in Chinese music.The Erhu has a small wooden body and a long neck.It is held on the lap,and the bow moves between the two strings to make music. 展开更多
关键词 traditional culture chinese fiddleit two stringed instrument ERHU chinese violin bow moves two strings musical instrument BOW
在线阅读 下载PDF
Exploration and Practice of Laboratory Public Platform Management in the Context of High-Quality Development
10
作者 Xu WANG Hao JIANG +2 位作者 Junyan ZHU Chuanyi PENG Guangjin LIU 《Asian Agricultural Research》 2025年第10期1-4,共4页
In the context of"high-quality development"construction,the establishment and operational status of the national-level scientific research platforms at provincial universities—specifically,the large-scale i... In the context of"high-quality development"construction,the establishment and operational status of the national-level scientific research platforms at provincial universities—specifically,the large-scale instrument sharing platforms—are critically linked to the production of scientific research outcomes and the development of interdisciplinary talents.This study focuses on the public platform of the State Key Laboratory of Tea Plant Germplasm Innovation and Resource Utilization,aiming to innovate the management system,establish a technical platform,effectively integrate resources,and actively engage graduate students in the platform management.While ensuring the efficient operation of the large-scale instrument platform at state key laboratories,it offers a novel approach to cultivating graduate students into versatile talents. 展开更多
关键词 Open SHARING LARGE-SCALE instrument MANAGEMENT system TALENT CULTIVATION
在线阅读 下载PDF
The Impact of Quality Nursing on Instrument Quality Management and Department Satisfaction in the Management of Reusable Instruments in the Central Sterile Supply Department
11
作者 Jie Li 《Journal of Clinical and Nursing Research》 2025年第6期385-391,共7页
Objective:To evaluate the effectiveness of quality nursing in the management of reusable instruments in the Central Sterile Supply Department(CSSD).Methods:Eleven nurses from the CSSD department were selected from Jan... Objective:To evaluate the effectiveness of quality nursing in the management of reusable instruments in the Central Sterile Supply Department(CSSD).Methods:Eleven nurses from the CSSD department were selected from January to October 2024,and quality nursing activities were implemented in the management of reusable instruments.The completion of quality indicators was analyzed.The instrument quality management scores,department satisfaction,and nurses’professional ability scores before and after nursing management were compared.Results:After nursing intervention,the qualified rates of initial cleaning and final cleaning of sterilization instruments were 99.66%and 100%,respectively.The qualified rate of packaging was 99.97%,the wet package rate was 0.1‰,the loading qualified rate was 99.88%,and the qualified rate of distribution was 99.99%.After nursing intervention,the nurses’instrument quality management scores,department satisfaction,and nurses’professional ability scores were all higher than those before nursing intervention(P<0.05).Conclusion:Quality nursing activities can improve the cleaning,packaging,and sterilization qualified rates of reusable instruments in the CSSD,enhance the effect of instrument quality management,obtain higher department satisfaction from nurses,cultivate their professional abilities,and possess significant nursing management advantages. 展开更多
关键词 Quality nursing Central Sterile Supply Department Reusable instrument management Instrument quality management Department satisfaction
暂未订购
Development of 6 inch 80–170 GHz Broadband Silicon Plated Horn Antenna Arrays for Primordial Gravitational Wave Search
12
作者 Yuan-Hang He Shi-Bo Shu +18 位作者 Ya-Qiong Li Xue-Feng Lu Ye Chai Xiang Li Zhi Chang He Gao Yu-Dong Gu Xu-Fang Li Zheng-Wei Li Zhou-Hui Liu Guo-Feng Wang Zhong-Xue Xin Dai-Kang Yan Ai-Mei Zhang Yi-Fei Zhang Yong-Jie Zhang Wen-Hua Shi Jue-Xian Cao Cong-Zhan Liu 《Research in Astronomy and Astrophysics》 2025年第5期34-46,共13页
Searching for primordial gravitational waves in the cosmic microwave background(CMB)polarization signal is one of the key topics in modern cosmology.Cutting-edge CMB telescopes require thousands of pixels to maximize ... Searching for primordial gravitational waves in the cosmic microwave background(CMB)polarization signal is one of the key topics in modern cosmology.Cutting-edge CMB telescopes require thousands of pixels to maximize mapping speed.Using a modular design,the telescope focal plane is simplified to several detector modules.Each module has hundreds of pixels including antenna arrays,detector arrays,and readout arrays.The antenna arrays,as the beam defining component,determine the overall optical response of the detector module.In this article,we present the developments of 6 inch broadband antenna arrays from 80 to 170 GHz for the future IHEP focal plane module.The arrays are fabricated from 426 inch silicon wafers including 456 antennas,7%more pixels than the usual design.The overall in-band cross polarization is smaller than-20 dB and the in-band beam asymmetry is smaller than 10%,fulfilling the requirements for primordial gravitational wave search. 展开更多
关键词 INSTRUMENTATION detectors-Astronomical Instrumentation Methods and Techniques-(cosmology )cosmic background radiation
在线阅读 下载PDF
Modeling of Astroclimatic Parameters by ERA5 at the Roque De Los Muchachos Observatory(ORM)Site
13
作者 Tarik Mouhtafid M.Sabil +2 位作者 Z.Ihsane S.Oujaoura E.A.Siher 《Research in Astronomy and Astrophysics》 2025年第12期227-241,共15页
In this article,we have modeled the astroclimatic parameters using data from the fifth reanalysis series(ERA5)from the European Centre for Medium-Range Weather Forecasts over the period 2010-2020.These data have been ... In this article,we have modeled the astroclimatic parameters using data from the fifth reanalysis series(ERA5)from the European Centre for Medium-Range Weather Forecasts over the period 2010-2020.These data have been projected onto the site of the Roque de los Muchachos Observatory(ORM).The analysis covers the main parameters influencing the quality of astronomical observation,notably the vertical profiles of temperature,potential temperature,and optical turbulence(C_(n)~2),as well as the vertical wind distributions and seasonal behaviors of atmospheric turbulence,which are treated in detail by specifying the wind speed at the 200 hPa level(V200).Around this level,the wind at high altitude presents moderate speeds and a generally stable direction,conditions favorable for adaptive optics.The thermal profiles show good agreement with standard atmospheric models,with a well-defined tropopause and a stable stratosphere,as well as the integrated parameters such as seeing(free and total),isoplanatic angle,and coherence time.The results reveal a stratified and stable atmosphere,with turbulence predominantly concentrated in the lower troposphere.The thermal profiles show a good agreement with standard atmospheric models,with a well-defined tropopause and a stable stratosphere.The seasonality of the astroclimatic parameters indicates conditions particularly favorable for observation during the winter months,with the median of free seeing,total seeing,isoplanatic angle and a coherence time as respectively 0″.48,0″.72,2″,and 6 ms.These results confirm the strong potential of ORM as a reference astronomical site,capable of hosting high-precision observation instruments.The methodological approach employed also provides a replicable basis for the characterization of other candidate sites for the installation of ground-based telescopes.As a preliminary study,this work establishes a scientific basis for further on-site monitoring and detailed characterization of the ORM site. 展开更多
关键词 instrumentation:adaptive optics atmospheric effects Physical Data and Processes instrumentation:photometers
在线阅读 下载PDF
Pulling apart patterns and fabric fingerprinting
14
《China Textile》 2025年第3期54-55,共2页
A leading position in the areas of testing,instrumentation and machine control has been established by members of the British Textile Machinery Association(BTMA)and a number of new developments in these fields will be... A leading position in the areas of testing,instrumentation and machine control has been established by members of the British Textile Machinery Association(BTMA)and a number of new developments in these fields will be showcased at this year’s ITMA Asia+CITME exhibition,which takes place in Singapore from October 28-31.“Many of our members are currently developing new technologies,either in-house or increasingly through joint projects,and there will be much to reveal by the time of ITMA Asia in Singapore,”says BTMA CEO Jason Kent.“Some of the most recent developments are really going beyond what has previously been possible.” 展开更多
关键词 fabric fingerprinting technologies machine control PATTERNS testing btma itma asia citme instrumentation
在线阅读 下载PDF
Research on Adjustable Cold View Field Diaphragm in Optical System with Linear Array Detector in AIMS
15
作者 Lianwei Zhao Meng Mou +4 位作者 Zhanhu Wang Qing Fan Chenjun Zhang Jianwen Hua Lei Ding 《Research in Astronomy and Astrophysics》 2025年第2期173-181,共9页
The infrared Fourier transform spectrometer needs a cold view field diaphragm to reduce stray radiation.For an infrared spectrometer with linear array detectors,the part of the view field diaphragm where the light pas... The infrared Fourier transform spectrometer needs a cold view field diaphragm to reduce stray radiation.For an infrared spectrometer with linear array detectors,the part of the view field diaphragm where the light passes can be regarded as a slit.If the infrared detectors are small in size,the width of the slit is also small,which will cause serious diffraction phenomena.If the widths of the view field diaphragm and the optical system are designed by geometric optics theory,the diffraction light cannot be fully received by the detectors,which will cause energy loss.Expanding the width of the view field diaphragm will introduce stray radiation.Meanwhile,spectrometer follow-up optics should be set in cold environments to reduce the infrared background of the instrument.Optical materials have different thermal characteristics,the optical and mechanical structures will deform at lowtemperature,and the cold view field diaphragm is installed at room temperature,so it is impossible to guarantee that the cold view field diaphragm remains in its design position when working at low-temperature.This paper solves the above problems by designing an adjustable cold view field diaphragm installed in its cryogenic vacuum chamber.The width and position of the view field diaphragm can be adjusted when working in cold temperatures,without opening the cryogenic vacuum chamber.Contrasting the interference signal obtained by the detectors in the adjustment process,the system can get the most suitable width and position of the cold view field diaphragm.The above works are based on the spectrometer used in the study named Accurate Infrared Magnetic Field Measurements of the Sun. 展开更多
关键词 instrumentation:interferometers instrumentation:detectors Sun:infrared Sun:magnetic fields
在线阅读 下载PDF
AI Method for LAMOST Fiber Detection Based on Front Illumination
16
作者 Zhangze Chen Yihan Song +2 位作者 Ali Luo Guanru Lv Haotong Zhang 《Research in Astronomy and Astrophysics》 2025年第6期36-48,共13页
The double revolving fiber positioning technology employed in the Large Sky Area Multi-Object Fiber Spectroscopic Telescope(LAMOST)represents one of the most successful advancements in large-scale multiobjective spect... The double revolving fiber positioning technology employed in the Large Sky Area Multi-Object Fiber Spectroscopic Telescope(LAMOST)represents one of the most successful advancements in large-scale multiobjective spectroscopy.The precision of fiber positioning is crucial,as it directly impacts the observational efficiency of LAMOST.A critical component of the fiber positioning system is the closed-loop control system,which traditionally utilizes the light spot generated at fiber end.However,this study introduces a novel approach based on front-illuminated LAMOST focal plane image measurements.Unlike back-illumination,front-illumination does not necessitate internal lighting in the spectrograph,thus reducing light pollution and eliminating the need for additional photography.This method employs an artificial intelligence model to analyze images captured at the focal plane unit(FPU),using the image of the white ceramic head on the FPU as the data set for training,the model is capable of accurately measuring the fiber positions solely through front-illumination.Preliminary trials indicate that the measurement accuracy achieved using the frontillumination method is approximately 0."13.This level of precision meets the stringent fiber positioning accuracy requirement of LAMOST,set at 0."2.Furthermore,this novel approach demonstrates compatibility with LAMOST’s existing closed-loop fiber control system,offering potential for seamless integration and enhanced operational efficiency. 展开更多
关键词 INSTRUMENTATION detectors-techniques image processing-methods data analysis
在线阅读 下载PDF
The Synchronization of Time for VLBI Observations
17
作者 Lei Liu Juan Zhang +1 位作者 Maoli Ma Weimin Zheng 《Research in Astronomy and Astrophysics》 2025年第3期31-37,共7页
For some space radio telescopes,the orbit determination accuracy is not high enough,the time synchronization accuracy provided by the satellite platforms is low,and GNSS devices are not available.As a result,a traditi... For some space radio telescopes,the orbit determination accuracy is not high enough,the time synchronization accuracy provided by the satellite platforms is low,and GNSS devices are not available.As a result,a traditional method that relies on GNSS devices to obtain an initial clock offset followed by performing correlation with the calibration source may fail to obtain fringes.Moreover,a brutal force search across the 2D clock offset and fringe rate search plane is computationally expensive.In light of these challenges,we propose a novel time synchronization method that utilizes the spacecraft’s telemetry tone signal.This method employs frequency polynomials derived from Doppler tracking for fringe rotation during the correlation process.By aligning the frequency of the target station precisely with that of the reference station,it is only necessary to split the clock offset search range into multiple time windows,perform correlation for each window,and identify the window with the highest signal-to-noise ratio(SNR).The precise clock offset is determined by combining the residual delay with the initial offset.To validate the method,we observe the Tianwen-1 telemetry signal with the 4.5 m small telescope in the Tianma campus of Shanghai Astronomical Observatory and 40 m telescope in Kunming.The results demonstrate that our method can accurately determine clock offset for a time range as wide as±10 ms,with an SNR slightly higher than that achieved with the delay model.This method is suitable for wide-range time synchronization for space Very Long Baseline Interferometry observations,especially in scenarios involving small antennas with low sensitivity and poor orbit determination accuracy. 展开更多
关键词 INSTRUMENTATION interferometers-methods data analysis-space vehicles instruments-techniques high angular resolution
在线阅读 下载PDF
The photometric system of the UCAS 70 cm Telescope
18
作者 Yiming Mao Liang Ge +8 位作者 Yongkang Sun Jingxiao Luo Xunhao Chen Renhao Ye Lifu Zhang Minglin Wang E Xiang Zhizhong Zhou Hong Wu 《Astronomical Techniques and Instruments》 2025年第3期198-209,共12页
This paper presents a comprehensive analysis of the photometric system of the University of Chinese Academy of Sciences 70 cm Telescope located at the Yan-qi Lake campus of the University of Chinese Academy of Science... This paper presents a comprehensive analysis of the photometric system of the University of Chinese Academy of Sciences 70 cm Telescope located at the Yan-qi Lake campus of the University of Chinese Academy of Sciences.We evaluated the linearity,bias stability,and dark current of the camera.Utilizing the Johnson-Cousins Blue-Visible-Red-Infrared filter system and an Andor DZ936 charge-coupled device camera,we conducted extensive observations of Landolt standard stars to determine the color terms,atmospheric extinction coefficients,photometric zero-points,and the sky background brightness.The results indicate that this telescope demonstrates excellent performance in photometric calibration and good system performance overall,meeting the requirements for limited scientific research and teaching purposes. 展开更多
关键词 Astronomical instrumentation Astronomical detectors Optical telescopes PHOTOMETRY Astronomical techniques
在线阅读 下载PDF
Comparative Analysis of Wavelet and Hilbert Transforms for Vehicle-Based Identification of Bridge Damping Ratios
19
作者 Judy P.Yang Yuan-Jun Zhang 《Computer Modeling in Engineering & Sciences》 2025年第7期669-691,共23页
Much of the research has focused on identifying bridge frequencies for health monitoring,while the bridge damping ratio also serves as an important factor in damage detection.This study presents an enhanced method for... Much of the research has focused on identifying bridge frequencies for health monitoring,while the bridge damping ratio also serves as an important factor in damage detection.This study presents an enhanced method for identifying bridge damping ratios using a two-axle,three-mass test vehicle,relying on wheel responses captured by only two mounted sensors.Damping ratio estimation formulas are derived using both the Hilbert Transform(HT)and Wavelet Transform(WT),with a consistent formulation that confirms accurate estimation is achievable with minimal instrumentation,particularly when addressing the support effect.A comparative analysis of the two signal processing techniques reveals the superior performance of WT in identifying bridge damping ratios.The effectiveness of the proposed procedure and formulas is validated through a detailed parametric study,demonstrating robustness across bridges with varying modal damping ratios and different spans using minimal sensors.Moreover,the present study shows that responses from only the first two spans of a multi-span bridge are sufficient for reliable damping estimation,underscoring the practicality and scalability of the procedure for structural health monitoring applications. 展开更多
关键词 Bridge damping ratio vehicle-bridge interaction signal processing minimal instrumentation multispan bridge
在线阅读 下载PDF
High through-put groundwater arsenic speciation analysis using an automated flow analyzer
20
作者 Guangyong Bo Tengyue Fang +2 位作者 Yanhua Duan Yan Zheng Jian Ma 《Journal of Environmental Sciences》 2025年第7期87-98,共12页
The occurrence of geogenic arsenic(As)in groundwater is a global public health concern.However,there remain large gaps in groundwater As data,making it difficult to identify non-compliant domestic wells,partly due to ... The occurrence of geogenic arsenic(As)in groundwater is a global public health concern.However,there remain large gaps in groundwater As data,making it difficult to identify non-compliant domestic wells,partly due to lack of low-cost methods capable of rapid As analysis.Therefore,the development of high through-put and reliable on-site determination methods for inorganic As is essential.Herein,a portable automated analyzer was developed for the determination of arsenite(As(Ⅲ)),arsenate(As(Ⅴ))and phosphate in As contaminated groundwater based on a previously adapted method for molybdenum blue spectrophotometry.After the optimization of the chemical reactions and flow manifold,the system demonstrated a high sample through-put(4.8/h for As(Ⅲ),As(Ⅴ)and phosphate analysis),allowing this system to screen 125 samples in 24 h.Other advantages include low operational costs(0.3 CNY per sample),appropriate sensitivity for contaminated groundwater(detection limits of 4.7μg/L,8.3μg/L and 5.4μg/L for As(Ⅲ),As(Ⅴ)and phosphate,respectively),good linearity(R^(2)>0.9996 at As concentrations up to 1600μg/L)and high precision(relative standard deviations of 3.5% and 2.8% for As(Ⅲ)and As(Ⅴ),respectively).The portable system was successfully used for As speciation analysis in 5 groundwater samples collected from multi-level wells at Yinchuan Plain,northwestern China,with total As concentrations ranging from 75.7 to 295.0μg/L,independently assessing As speciation,providing a promising novel method for the rapid on-site screening of As in tens of millions of domestic wells worldwide. 展开更多
关键词 Arsenic screening On-site analysis Chemical speciation Portable instrument Flow analysis
原文传递
上一页 1 2 116 下一页 到第
使用帮助 返回顶部