期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Detection of hepatic and pancreatic fat infiltration in type II diabetes mellitus patients with IDEAL-Quant using 3.0T MR: comparison with single-voxel proton spectroscopy 被引量:6
1
作者 Ma Jing Song Zhiqiang Yan Fuhua 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第20期3548-3552,共5页
Background Type II diabetes mellitus usually related to visceral and other organ (ectopic) fat. The purpose of this study was to detect hepatic and pancreatic fat infiltration in type II diabetes meUitus patients us... Background Type II diabetes mellitus usually related to visceral and other organ (ectopic) fat. The purpose of this study was to detect hepatic and pancreatic fat infiltration in type II diabetes meUitus patients using 3.0T magnetic resonance (MR) and to compare the performance of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL-Quant) with single-voxel proton spectroscopy (HI-MRS). Methods The study protocol was approved by our Institutional Review Board. Written informed consent was obtained from each subject in this study. We prospectively performed IDEAL-Quant and single-voxel proton spectroscopy with an echo time of 35 ms on 24 type II diabetes patients and 10 healthy volunteers. The hepatic proton density fat fraction (HPDFF) and pancreatic proton density fat fraction (PPDFF) were calculated, compared, and analyzed by t-tests and Spearman's correlation. Results The HPDFF and PPDFF measured with IDEAL-Quant were significantly different between the healthy volunteers and type II diabetes patients (th=9.377, P=0.000; tp=2.813, P=0.008). The HPDFF and PPDFF measured with MRS were also significantly different between the healthy volunteers and type II diabetes patients (th=5.342, P=0.000; tp=2.63, P=0.013). The HPDFF and PPDFF measured by the two methods were in good agreement (rh=0.854, P=-0.000; rp=0.774, P=0.000). The HPDFF and PPDFF were not significantly correlated with each other (rMRs=0.203, p=0.248; rpDEAL_Quant=0.301, P=0.084). The PPDFF measured with IDEAL-Quant was associated with body mass index (t=0.377, P=0.028). Conclusion IDEAL-Quant is a nice method for hepatic and pancreatic fat detection, and it can be applied in clinical practice. 展开更多
关键词 liver PANCREAS ideal-quant HI-MRS proton density fat fraction
原文传递
磁共振IDEAL-IQ与mDixon Quant技术对腹部、椎体脂肪定量的对比研究
2
作者 尤蕊 《医学信息》 2026年第5期118-122,共5页
目的探讨不同平台3.0T MR设备魔镜成像(mDixon Quant)和非对称回波最小二乘估算法迭代水脂分离序列(IDEAL-IQ)序列对腹部、椎体脂肪分数(FF)定量测量的差异性。方法选择2022年10月-2024年10月我院100例健康志愿者作为研究对象,按照随机... 目的探讨不同平台3.0T MR设备魔镜成像(mDixon Quant)和非对称回波最小二乘估算法迭代水脂分离序列(IDEAL-IQ)序列对腹部、椎体脂肪分数(FF)定量测量的差异性。方法选择2022年10月-2024年10月我院100例健康志愿者作为研究对象,按照随机数字表法将其分为对照组和试验组,每组50例。对照组进行IDEAL-IQ序列扫描,试验组进行mDixon Quant序列扫描。2名观察者测量所有志愿者腰椎(L_(1)~L_(5))椎体和腹部(肝脏、胰腺)的FF值并进行两序列间对比。结果2名观察者所测数据一致性良好(组内相关系数>0.75)。对照组测量的肝脏、胰腺以及腰椎椎体L_(1)、L_(2)、L_(3)、L_(4)、L_(5)的FF值与试验组比较,差异无统计学意义(P>0.05)。结论IDEAL-IQ与mDixon Quant序列均可定量测量腹部、椎体的FF值,其测量值具有高度一致性。 展开更多
关键词 磁共振 IDEAL-IQ mDixon Quant 腹部 椎体 脂肪分数 定量测量
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部