期刊文献+
共找到8,160篇文章
< 1 2 250 >
每页显示 20 50 100
Development of a Novel Parallel-spool Pilot Operated High-pressure Solenoid Valve with High Flow Rate and High Speed 被引量:6
1
作者 DONG Dai LI Xiaoning 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第2期369-378,共10页
High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate a... High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate and high speed simultaneously.A new structure for a high pressure solenoid valve is needed to meet the demand of the underwater driving system.A novel parallel-spool pilot operated high-pressure solenoid valve is proposed to overcome the drawback of the current single spool design.Mathematical models of the opening process and flow rate of the valve are established.Opening response time of the valve is subdivided into 4 parts to analyze the properties of the opening response.Corresponding formulas to solve 4 parts of the response time are derived.Key factors that influence the opening response time are analyzed.According to the mathematical model of the valve,a simulation of the opening process is carried out by MATLAB.Parameters are chosen based on theoretical analysis to design the test prototype of the new type of valve.Opening response time of the designed valve is tested by verifying response of the current in the coil and displacement of the main valve spool.The experimental results are in agreement with the simulated results,therefore the validity of the theoretical analysis is verified.Experimental opening response time of the valve is 48.3 ms at working pressure of 10 MPa.The flow capacity test shows that the largest effective area is 126 mm2 and the largest air flow rate is 2320 L/s.According to the result of the load driving test,the valve can meet the demands of the driving system.The proposed valve with parallel spools provides a new method for the design of a high-pressure valve with fast response and large flow rate. 展开更多
关键词 high-pressure pneumatic solenoid valve parallel-spool high flow rate high speed opening response time
在线阅读 下载PDF
Polymer-Based Micro Flow Sensor with Alternative Electronic Signal Interfaces for Low and High Flow Rates
2
作者 Thomas Schoenstein 《Journal of Chemistry and Chemical Engineering》 2014年第4期417-420,共4页
The qualitative and quantitative assessment of gas flow has become increasingly relevant in the use of everyday systems. The micro flow sensor, developed by Innovative Sensor Technology AG (Switzerland), is by princ... The qualitative and quantitative assessment of gas flow has become increasingly relevant in the use of everyday systems. The micro flow sensor, developed by Innovative Sensor Technology AG (Switzerland), is by principle a calorimetric flow sensor produced as a micro system on a glass substrate by means of photolithography and glass etching technology. These structures are arranged as a platinum micro heater and sensor in a Wheatstone bridge. The subsequent etching process produces an exposed area of polyimide membrane that is only a few microns thick and includes the resistive sensor structure as the active area. In addition, the RTD (resistance temperature detector) technology included on the sensor allows for the implementation of a variety of electronic biasing and signal processing modes. Since the sensor can be powered and the bridge can be measured in both CTA (constant temperature anemometer) and calorimetric mode, new possibilities are presented for both low and high flow rates with regard to temperature compensation, self-calibration and self-monitoring. 展开更多
关键词 Calorimetric flow sensor pick place assembly CTA-mode low and high flow rates.
在线阅读 下载PDF
Electrical Resistivity Contrasts and High Flow Rates Discontinuous Aquifers Identification in a Sheared Crystallophyllian Basement Zone at Boniérédougou (North-Central Côte d’Ivoire)
3
作者 Simon Pierre Djroh Kouamelan Serge Kouamelan +1 位作者 Yacouba Ouattara Serge Pacome Dégine Gnoleba 《Journal of Geoscience and Environment Protection》 2022年第11期35-49,共15页
This study proposes an alternative approach to the investigation of high flow hydrogeological fractures within the basement in the Dabakala region of north-central C&#244;te d’Ivoire. The used approach consists o... This study proposes an alternative approach to the investigation of high flow hydrogeological fractures within the basement in the Dabakala region of north-central C&#244;te d’Ivoire. The used approach consists of exploring the subsurface by measuring electrical resistivity contrasts along the main shear direction within crystallophyllian rocks. Electrical resistivity profiling and vertical electrical sounding techniques, coupled with boreholes monitoring, have identified fractured aquifers whose best flow rates are around 96 and 116 m<sup>3</sup>/h. These aquifers mostly hosted in granodiorite have an average strength of 10 meters and are located at depth of around 100 meters. They are associated with open fractures created by tangential shear stresses that have affected the Dabakala volcano-sedimentary trench formations. The search for fractured aquifers along the main shear direction offers great perspective for obtaining high flow rates. 展开更多
关键词 SHEAR Fractured Aquifer high flow Rate Côte d’Ivoire
在线阅读 下载PDF
Advances in gas-particle dynamics:insights from high-speed flows
4
作者 Baoguo XIAO Wanzhou ZHANG 《Chinese Journal of Aeronautics》 2025年第6期177-178,共2页
1. Introduction High-speed gas-particle flows are crucial in engineering applications and natural phenomena, such as volcanic eruptions,combustion, and hypersonic flight. These flows involve complex gas-particle inter... 1. Introduction High-speed gas-particle flows are crucial in engineering applications and natural phenomena, such as volcanic eruptions,combustion, and hypersonic flight. These flows involve complex gas-particle interactions, posing significant challenges for simulations and experiments. This research highlight summarizes recent advancements in gas-particle dynamics under compressible conditions, covering key findings, numerical and experimental progress, and future directions. Details can be found in the work of Capecelatro and Wagner (Gas-particle dynamics in high-speed flows. Annual Review of Fluid Mechanics 2024;56:379–403). 展开更多
关键词 high speed gas particle flows engineering applications natural phenomenasuch experiments gas particle interactions compressible conditions volcanic eruptionscombustionand hypersonic flightthese
原文传递
High-flow nasal oxygen availability for sedation decreases the use of general anesthesia during endoscopic retrograde cholangiopancreatography and endoscopic ultrasound 被引量:10
5
作者 Roman Schumann Nikola S Natov +4 位作者 Klifford A Rocuts-Martinez Matthew D Finkelman Tom V Phan Sanjay R Hegde Robert M Knapp 《World Journal of Gastroenterology》 SCIE CAS 2016年第47期10398-10405,共8页
AIM To examine whether high-flow nasal oxygen(HFNO) availability influences the use of general anesthesia(GA) in patients undergoing endoscopic retrograde cholangiopancreatography(ERCP) and endoscopic ultrasound(EUS) ... AIM To examine whether high-flow nasal oxygen(HFNO) availability influences the use of general anesthesia(GA) in patients undergoing endoscopic retrograde cholangiopancreatography(ERCP) and endoscopic ultrasound(EUS) and associated outcomes.METHODS In this retrospective study, patients were stratified into 3 eras between October 1, 2013 and June 30, 2014 based on HFNO availability for deep sedation at the time of their endoscopy. During the first and last 3-mo eras(era 1 and 3), no HFNO was available, whereas it was an option during the second 3-mo era(era 2). The primary outcome was the percent utilization of GA vs deep sedation in each period. Secondary outcomes included oxygen saturation nadir during sedation between periods, as well as procedure duration, and anesthesia-only time between periods and for GA vs sedation cases respectively.RESULTS During the study period 238 ERCP or EUS cases were identified for analysis. Statistical testing was employed and a P < 0.050 was significant unless the Bonferroni correction for multiple comparisons was used. General anesthesia use was significantly lower in era 2 compared to era 1 with the same trend between era 2 and 3(P = 0.012 and 0.045 respectively). The oxygen saturation nadir during sedation was significantly higher in era 2 compared to era 3(P < 0.001) but not between eras 1 and 2(P = 0.028) or 1 and 3(P = 0.069). The procedure time within each era was significantly longer under GA compared to deep sedation(P ≤ 0.007) as was the anesthesia-only time(P ≤ 0.001).CONCLUSION High-flow nasal oxygen availability was associated with decreased GA utilization and improved oxygenation for ERCP and EUS during sedation. 展开更多
关键词 Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography ENDOSCOPY SEDATION ANESTHESIA OXYGENATION high flow nasal oxygen
暂未订购
Performance analysis and improvement of a high flow coefficient centrifugal compressor 被引量:5
6
作者 WANG YongSheng WANG Kai +2 位作者 LIN Feng NIE ChaoQun ENGEDA Abraham 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第8期1647-1657,共11页
Very high flow coefficient centrifugal compressor stages are mostly performance of this type of stages is critical to the entire centrifugal applied as the first stages of multistage compressors. The compressors, but ... Very high flow coefficient centrifugal compressor stages are mostly performance of this type of stages is critical to the entire centrifugal applied as the first stages of multistage compressors. The compressors, but surprisingly little related information is available in the open literature. A centrifugal compressor with high inlet flow coefficient of 0.2, presenting a narrow operating range and unstable running situation even at design speed during the test, is investigated here. To reveal flow details in this centrifugal compressor, numerical simulations have been carried out and indicate that excessive impeller flow diffusion results in the poor performance of this centrifugal compressor. With the same inlet flow coefficient, six redesign cases coming from an in-house one-dimensional analysis program are proposed together with impeller trimming and equal flow area design method for corresponding vaneless diffuser. Performance comparison among these redesign centrifugal compressors is presented and the most suitable one is recommended for test in the future. In addition, three redesign cases with lower inlet flow coefficient developed by means of flow trimming are shown in the end to satisfy potential application areas. Finally, the results in this study can provide valuable reference information for multistage centrifugal compressor design. 展开更多
关键词 centrifugal compressor very high flow coefficient IMPROVEMENT impeller trimming
原文传递
High-flow nasal cannula oxygen therapy during anesthesia recovery for older orthopedic surgery patients: A prospective randomized controlled trial 被引量:4
7
作者 Xiao-Na Li Cheng-Cheng Zhou +4 位作者 Zi-Qiang Lin Bin Jia Xiang-Yu Li Gao-Feng Zhao Fei Ye 《World Journal of Clinical Cases》 SCIE 2022年第24期8615-8624,共10页
BACKGROUND Hypoxemia is a common complication in older patients during postoperative recovery and can cause pulmonary complications.Therefore,reducing the incidence of postoperative hypoxemia is a clinical concern.AIM... BACKGROUND Hypoxemia is a common complication in older patients during postoperative recovery and can cause pulmonary complications.Therefore,reducing the incidence of postoperative hypoxemia is a clinical concern.AIM To investigate the clinical efficacy of high-flow nasal cannula oxygen(HFNCO)in the resuscitation period of older orthopedic patients.METHODS In this prospective randomized controlled trial,60 older patients who underwent orthopedic surgery under general anesthesia were randomly divided into two groups:those who used conventional face mask and those who used HFNCO.All patients were treated with 60%oxygen for 1 h after extubation.Patients in the conventional face mask group were treated with a combination of air(2 L)and oxygen(2 L)using a traditional mask,whereas those in the HFNCO group were treated with HFNCO at a constant temperature of 34℃ and flow rate of 40 L/min.We assessed the effectiveness of oxygen therapy by monitoring the patients’arterial blood gas,peripheral oxygen saturation,and postoperative complications.RESULTS The characteristics of the patients were comparable between the groups.One hour after extubation,patients in HFNCO group had a significantly higher arterial partial pressure of oxygen(paO_(2))than that of patients in conventional face mask group(P<0.001).At extubation and 1 h after extubation,patients in both groups showed a significantly higher arterial partial pressure of carbon dioxide(paCO_(2))than the baseline levels(P<0.001).There were no differences in the saturation of peripheral oxygen,paO_(2),and paCO_(2) between the groups before anesthesia and before extubation(P>0.05).There were statistically significant differences in paO_(2) between the two groups before anesthesia and 1 h after extubation and immediately after extubation and 1 h after extubation(P<0.001).However,there were no significant differences in the oxygen tolerance score before leaving the room,airway humidification,and pulmonary complications 3 d after surgery between the two groups(P>0.05).CONCLUSION HFNCO can improve oxygen partial pressure and respiratory function in elderly patients undergoing orthopedic surgery under general endotracheal anesthesia.Thus,HFNCO can be used to prevent postoperative hypoxemia. 展开更多
关键词 Anesthesia recovery high flow nasal cannula oxygen HYPOXEMIA Older patients Orthopedic surgery Pulmonary complications
暂未订购
Assessment of climate change impact on high flows in a watershed characterized by flood regulating reservoirs 被引量:1
8
作者 Sabin Shrestha Suresh Sharma 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2021年第1期178-191,共14页
A climate-induced extreme flow event such as flooding is one of the most devastating natural hazards,which can significantly damage human lives and properties.This study examined the effects of climate change on the h... A climate-induced extreme flow event such as flooding is one of the most devastating natural hazards,which can significantly damage human lives and properties.This study examined the effects of climate change on the high flow conditions in the Great Miami River Watershed in Ohio under two emission scenarios(RCP 4.5 and RCP 8.5).Streamflow for the 21st century was simulated by utilizing a watershed model-SWAT(Soil and Water Assessment Tool)and 10 different climate outputs from the Coupled Model Intercomparison Project phase 5(CMIP5).The future streamflow was divided into three equal periods:2016-2043(early century),2044-2071(mid-century),and 2072-2099(late century)and independently analyzed to compare high flows of respective intervals with baseline periods(1988-2015).The analysis predicted that 7-day,10-year high-flow(7Q10)would increase by 38%under RCP 4.5 and 44%under RCP 8.5.Similarly,the annual peak flows for study periods were predicted to increase by 26%under RCP 4.5 and 38%under RCP 8.5 from the base period.However,the analysis demonstrated an erratic response for monthly peaks indicating that the peak flow would increase in summer months-May and July to October.Meanwhile,the result did not show any significant increase during the winter season,especially from November to April.The analysis of the four major dams located in the watershed showed that the dam’s peak discharges increase in January,May,and September.Even though increasing peaks were projected in September for the 21st century,the monthly peaks from the watershed outlet were found to be lowest in September as compared to other months.The frequency of future flooding compared to the historical record was found to be increasing in the mid-century under RCP 4.5 and the late century under RCP 8.5.As the future flood is projected to increase,this study finds the reasonable impact of climate change on flood regulating reservoirs/dams in monthly flows.However,daily high flows(90th percentile flow)would be increasing significantly(44%to 250%)under RCP 8.5. 展开更多
关键词 climate change high flows SWAT Great Miami River Watershed flood regulating reservoir ASSESSMENT
原文传递
A High-speed Nature Laminar Flow Airfoil and Its Experimental Study in Wind Tunnel with Nonintrusive Measurement Technique 被引量:8
9
作者 朱军 高正红 +1 位作者 詹浩 白俊强 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2009年第3期225-229,共5页
This article deals with an experimental study on the aerodynamic characteristics of a low-drag high-speed nature laminar flow (NLF) airfoil for business airplanes in the TST27 wind tunnel at Delft University of Techno... This article deals with an experimental study on the aerodynamic characteristics of a low-drag high-speed nature laminar flow (NLF) airfoil for business airplanes in the TST27 wind tunnel at Delft University of Technology, the Netherlands. In this experiment, in an attempt to reduce the errors of measurement and improve its accuracy in high-speed flight, some nonintrusive meas- urement techniques, such as the quantitative infrared thermography (IRT), the digital particle imaging velocimetry (PIV), and the s... 展开更多
关键词 wind tunnels particle imaging velocimetry infrared thermography SHADOWGRAPHY high-speed nature laminar flow airfoil
原文传递
End-of-life home care of an interstitial pneumonia patient supported by high-flow nasal cannula therapy:A case report
10
作者 Ken Goda Tsuneaki Kenzaka +2 位作者 Kyosuke Kuriyama Masahiko Hoshijima Hozuka Akita 《World Journal of Clinical Cases》 SCIE 2020年第20期4853-4857,共5页
BACKGROUND High-flow nasal cannula(HFNC)therapy and morphine continuous subcutaneous infusion(CSI)have been used to ameliorate dyspnea in non-cancer patients with end-stage respiratory diseases,including chronic obstr... BACKGROUND High-flow nasal cannula(HFNC)therapy and morphine continuous subcutaneous infusion(CSI)have been used to ameliorate dyspnea in non-cancer patients with end-stage respiratory diseases,including chronic obstructive pulmonary disease and interstitial pneumonia,primarily in hospital settings.However,it is rare to perform home-based medical treatment using these.We observe a case to assess the feasibility of this treatment strategy.CASE SUMMARY Here,we report a case of a 75-year-old man who was diagnosed with interstitial pneumonia 11 years ago and was successfully nursed at home during his terminal phase for over 10 mo without hospitalization,by introducing domiciliary uses of HFNC and morphine CSI with a patient-controlled analgesia device.CONCLUSION Active utilization of HFNC and morphine CSI with patient-controlled analgesia device would substantiate successful end-of-life palliative home care of idiopathic interstitial pneumonia patients. 展开更多
关键词 high flow nasal cannula Continuous subcutaneous infusion MORPHINE Patient controlled analgesia Home care Interstitial pneumonia Case report
暂未订购
High-flow priapism due to bilateral cavernous artery fistulas treated by unilateral embolization:A case report
11
作者 Guo Li Yi Liu +2 位作者 Hao-Yang Wang Fei-Zhou Du Zhi-Wei Zuo 《World Journal of Clinical Cases》 SCIE 2023年第1期225-232,共8页
BACKGROUND High flow priapism(HFP)is a rare type of priapism.Perineal trauma is the most common cause of HFP.Trauma-induced penile artery injury may lead to an arterial-cavernosal fistula,whereas persistent irregular ... BACKGROUND High flow priapism(HFP)is a rare type of priapism.Perineal trauma is the most common cause of HFP.Trauma-induced penile artery injury may lead to an arterial-cavernosal fistula,whereas persistent irregular arterial blood flow entering the corpora cavernosum can cause a persistent penile erection.The routine treatment of HFP focuses on addressing the abnormal penile erectile status and avoiding post-treatment erectile dysfunction.Interventional embolization is an important therapeutic modality for HFP,and bilateral embolization therapy is currently the most commonly used technique for patients with bilateral cavernous artery fistulas;however,unilateral embolization therapy has yet to be reported.CASE SUMMARY Herein,we report of the case of a 26-year-old Chinese male who presented with a persistent abnormal erection for 12 h after perineal impact injury.Medical history,cavernous arterial blood gas analysis and radiological examinations led to a diagnosis of HFP caused by bilateral cavernous artery fistulas.We performed routine conservative treatment(compression therapy and ice application)for the patient after admission;however,10 d later,his symptoms had not been relieved.After completion of the preoperative workup,right(severe side)selective perineal artery embolization was performed;the left cavernous artery fistula was left untreated.After postoperative continuation of conservative treatment for 72 h,the patient experienced complete penile thinning.The patient had no symptoms of erectile dysfunction over a follow-up period of 12 mo.CONCLUSION Compared with bilateral cavernous artery fistula embolization,we believe that unilateral cavernous artery fistula embolization can achieve positive clinical efficacy and reduce the risk of postoperative erectile dysfunction secondary to penile ischemia. 展开更多
关键词 high flow priapism Elective pudendal artery embolization Cavernous fistula Erectile dysfunction Case report
暂未订购
Impact and Management under Extracorporeal Circulation of a Patient with Renal Insufficiency on Dialysis with a High-Flow Arteriovenous Fistula in the Cardiac Surgery Department of the Angers Teaching Hospital about a Case and Review of the Literature
12
作者 Abdoulaye Kanté Bréhima Coulibaly +6 位作者 Mamadou Diakité Mamadou A. Keita Bakary Keita Drissa Traoré Nouhoum Ongoïba Patrice Binuani Christophe Baufreton 《Open Journal of Thoracic Surgery》 2023年第1期1-5,共5页
Arteriovenous fistulas have a substantial impact on systemic hemodynamics, however their effect on extracorporeal circulation is not well understood. We report our clinical observation on the management under extracor... Arteriovenous fistulas have a substantial impact on systemic hemodynamics, however their effect on extracorporeal circulation is not well understood. We report our clinical observation on the management under extracorporeal circulation of a patient with renal insufficiency with a high-flow arteriovenous fistula. This is a 59-year-old man who was referred to us for surgical treatment of ischemic coronary artery disease in a context of anuric chronic renal failure. Hypothermia at 32°C is started from the start in CEC due to hyperflow at the level of the arteriovenous fistula. We performed two coronary artery bypasses of the marginal and IVA via the two internal thoracic arteries. The patient is hemofiltered in order to avoid hyperkalaemia and possibly avoid fluid overload related to filling per CEC. The clamping time was 71 minutes and the SCC lasted 141 minutes. There was no homologous transfusion in the operating room. It turns out that the input/output balance is zero at the end of the CEC. The postoperative course was simple. 展开更多
关键词 Coronaryartery by Pass Grafting high flow Arteriovenous Fistula Extracorporeal Circulation HYPOTHERMIA
暂未订购
NONPARALLEL BOUNDARY LAYER STABILITY IN HIGH SPEED FLOWS 被引量:1
13
作者 郭欣 唐登斌 沈清 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2008年第2期81-88,共8页
The parabolized stability equations (PSEs) for high speed flows, especially supersonic and hypersonic flows, are derived and used to analyze the nonparallel boundary layer stability. The proposed numerical technique... The parabolized stability equations (PSEs) for high speed flows, especially supersonic and hypersonic flows, are derived and used to analyze the nonparallel boundary layer stability. The proposed numerical techniques for solving PSE include the following contents: introducing the efficiently normal transformation of the boundary layer, improving the computational accuracy by using a high-order differential scheme near the wall, employing the predictor-corrector and iterative approach to satisfy the important normalization condition, and implementing the stable spatial marching. Since the second mode dominates the growth of the disturbance in high Mach number flows, it is used in the computation. The evolution and characteristics of the boundary layer stability in the high speed flow are demonstrated in the examples. The effects of the nonparallelizm, the compressibility and the cooling wall on the stability are analyzed. And computational results are in good agreement with the relevant data. 展开更多
关键词 high speed flow boundary layers nonparallelism parabolized stability equations
在线阅读 下载PDF
The relationship between ENSO cycle and high and low-flow in the upper Yellow River 被引量:8
14
作者 LANYongchao DINGYongjiang +2 位作者 KANGErsi MAQuanjie ZHANGJishi 《Journal of Geographical Sciences》 SCIE CSCD 2003年第1期105-111,共7页
Firstly, the hydrological and meteorological features of the upper reaches of the Yellow River above Tangnag are analyzed based on observation data, and effects of EI Nino and La Ni na events on the high and low flow ... Firstly, the hydrological and meteorological features of the upper reaches of the Yellow River above Tangnag are analyzed based on observation data, and effects of EI Nino and La Ni na events on the high and low flow in the upper Yellow River are discussed. The results show El Nino and La Nina events possess consanguineous relationship wi th runoff in the upper Yellow River. As a whole, the probability of low fl ow occurrence in the upper Yellow River is relatively great along wit h the occurrence of El Nino event. Moreover, the flood in the upper Yellow River occurs frequently with the occurrence of La Nina event. Besides, the results also show dissimilarity of El Nino event occurri ng time exerts greater impact on high flow and low flow in the uppe r Yellow River, that is, the probability of drought will be greater in the sam e year if El Nino event occurs in spring, the high-flow may happen in this y ear if El Nino occurs in summer or autumn; the longer the continuous period of El Nino is, the lower the runoff in the upper Yellow River is. 展开更多
关键词 El Nino event La Nina event the upper Yellow River high-flow and low-flow
在线阅读 下载PDF
Experimental investigation on a high subsonic compressor cascade flow 被引量:11
15
作者 Zhang Haideng Wu Yun +1 位作者 Li Yinghong Lu Huawei 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2015年第4期1034-1043,共10页
With the aim of deepening the understanding of high-speed compressor cascade flow,this paper reports an experimental study on NACA-65 K48 compressor cascade with high subsonic inlet flow.With the increase of passage p... With the aim of deepening the understanding of high-speed compressor cascade flow,this paper reports an experimental study on NACA-65 K48 compressor cascade with high subsonic inlet flow.With the increase of passage pressurizing ability, endwall boundary layer behavior is deteriorated, and the transition zone is extended from suction surface to the endwall as the adverse pressure gradient increases.Cross flow from endwall to midspan, mixing of corner boundary layer and the main stream, and reversal flow on the suction surface are caused by corner separation vortex structures.Passage vortex is the main corner separation vortex.During its movement downstream, the size grows bigger while the rotating direction changes, forming a limiting circle.With higher incidence, corner separation is further deteriorated, leading to higher flow loss.Meanwhile, corner separation structure, flow mixing characteristics and flow loss distribution vary a lot with the change of incidence.Compared with low aspect-ratio model, corner separation of high aspect-ratio model moves away from the endwall and is more sufficiently developed downstream the cascade.Results obtained present details of high-speed compressor cascade flow,which is rare in the relating research fields and is beneficial to mechanism analysis, aerodynamic optimization and flow control design. 展开更多
关键词 COMPRESSOR Corner separation high speed Secondary flow TRANSITION
原文传递
A study of hydrate plug formation in a subsea natural gas pipeline using a novel high-pressure flow loop 被引量:12
16
作者 Li Wenqing Gong Jing +3 位作者 Lü Xiaofang Zhao Jiankui Feng Yaorong Yu Da 《Petroleum Science》 SCIE CAS CSCD 2013年第1期97-105,共9页
The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages i... The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages in the pipeline occur occasionally. To maintain the natural gas flow in the pipeline, we proposed a method for analyzing blockages and ascribed them to the hydrate formation and agglomeration. A new high-pressure flow loop was developed to investigate hydrate plug formation and hydrate particle size, using a mixture of diesel oil, water, and natural gas as experimental fluids. The influences of pressure and initial flow rate were also studied. Experimental results indicated that when the flow rate was below 850 kg/h, gas hydrates would form and then plug the pipeline, even at a low water content (10%) of a water/oil emulsion. Furthermore, some practical suggestions were made for daily management of the subsea pipeline. 展开更多
关键词 Natural gas hydrate BLOCKAGE flow assurance high-pressure loop water cut flow rate
原文传递
A Brief Review of High Entropy Alloys and Serration Behavior and Flow Units 被引量:5
17
作者 Yong ZHANG Jun-wei QIAO Peter K.LIAW 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2016年第1期2-6,共5页
Multicomponent alloys with high entropy of mixing,e.g.,high entropy alloys(HEAs)and/or multiprincipal-element alloys(MEAs),are attracting increasing attentions,because the materials with novel properties are being... Multicomponent alloys with high entropy of mixing,e.g.,high entropy alloys(HEAs)and/or multiprincipal-element alloys(MEAs),are attracting increasing attentions,because the materials with novel properties are being developed,based on the design strategy of the equiatomic ratio,multicomponent,and high entropy of mixing in their liquid or random solution state.Recently,HEAs with the ultrahigh strength and fracture toughness,excellent magnetic properties,high fatigue,wear and corrosion resistance,great phase stability/high resistance to heat-softening behavior,sluggish diffusion effects,and potential superconductivity,etc.,were developed.The HEAs can even have very high irradiation resistance and may have some self-healing effects,and can potentially be used as the first wall and nuclear fuel cladding materials.Serration behaviors and flow units are powerful methods to understand the plastic deformation or fracture of materials.The methods have been successfully used to study the plasticity of amorphous alloys(also bulk metallic glasses,BMGs).The flow units are proposed as:free volumes,shear transition zones(STZs),tension-transition zones(TTZs),liquid-like regions,soft regions or soft spots,etc.The flow units in the crystalline alloys are usually dislocations,which may interact with the solute atoms,interstitial types,or substitution types.Moreover,the flow units often change with the testing temperatures and loading strain rates,e.g.,at the low temperature and high strain rate,plastic deformation will be carried out by the flow unit of twinning,and at high temperatures,the grain boundary will be the weak area,and play as the flow unit.The serration shapes are related to the types of flow units,and the serration behavior can be analyzed using the power law and modified power law. 展开更多
关键词 high entropy alloy bulk metallic glass serration behavior flow unit
原文传递
Flow Stress Behaviors and Microstructure Evolution of 300M High Strength Steel under Isothermal Compression 被引量:6
18
作者 Rong-sheng QI Bao-feng GUO +1 位作者 Xin-gang LIU Miao JIN 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2014年第12期1116-1123,共8页
The compressive deformation behaviors of 300M high strength steel were investigated over a wide range of temperatures (850- 1200 C) and strain rates (0. 001- 10 s^- 1 ) on a Gleeble-3800 thermo-mechanical simulato... The compressive deformation behaviors of 300M high strength steel were investigated over a wide range of temperatures (850- 1200 C) and strain rates (0. 001- 10 s^- 1 ) on a Gleeble-3800 thermo-mechanical simulator. The measured flow stress was modified by the corrections of the friction and the temperature compensations, which nicely reflect negative effects of the friction and temperature on the flow stress. The corrected stress-strain curves were the dynamic recrystallization type on the conditions of higher deformation temperature and lower strain rate. Flow stress increases with the increase of strain rate at the same deformation temperature and strain. By contrast, flow stress decreases with the increase of temperature at the same strain rate and strain. Dependence of the peak stress on temperature and strain rate for 300M steel is described by means of the conventional hyperbolic sine equation. By re gression analysis, the activation energy (Q) in the whole range of deformation temperature is determined to be 367. 562 kJ/mol. The effects of the temperature and the strain rate on mierostructural evolution are obvious. With the increase of the deformation temperature and the decrease of the strain rate, the original austenite grain sizes of 300M steel increase. At the same time, the corrected flow stress curves more accurately determine the evolution of the microstrueture. 展开更多
关键词 300M high strength steel flow stress curve correction microstructural evolution
原文传递
ASYMMETRIC VORTICES FLOW OVER SLENDER BODY AND ITS ACTIVE CONTROL AT HIGH ANGLE OF ATTACK 被引量:17
19
作者 邓学蓥 王延奎 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2004年第6期567-579,共13页
The studies of asymmetric vortices flow over slender body and its active control at high angles of attack have significant importance for both academic field and engineering area.This paper attempts to provide an upda... The studies of asymmetric vortices flow over slender body and its active control at high angles of attack have significant importance for both academic field and engineering area.This paper attempts to provide an update state of art to the investigations on the fields of forebody asymmetric vortices.This review emphasizes the correlation between micro-perturbation on the model nose and its response and evolution behaviors of the asymmetric vortices.The critical issues are discussed, which include the formation and evolution mechanism of asymmetric multi-vortices;main behaviors of asymmetric vortices flow including its deterministic feature and vortices flow structure;the evolution and development of asymmetric vortices under the perturbation on the model nose;forebody vortex active control especially discussed micro-perturbation active control concept and technique in more detail.However present understanding in this area is still very limited and this paper tries to identify the key unknown problems in the concluding remarks. 展开更多
关键词 asymmetric vortex flow control high angle of attack aerodynamics slender body
在线阅读 下载PDF
Residence time distribution of high viscosity fluids falling film flow down outside of industrial-scale vertical wavy wall: Experimental investigation and CFD prediction 被引量:7
20
作者 Shichang Chen Lihao Zhang +2 位作者 Yongjun Wang Xianming Zhang Wenxing Chen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第7期1586-1594,共9页
The flow behavior of gravity-driven falling film of non-conductive high viscosity polymer fluids on an industrial-scale vertical wavy wall was investigated in terms of film thickness and residence time distribution by... The flow behavior of gravity-driven falling film of non-conductive high viscosity polymer fluids on an industrial-scale vertical wavy wall was investigated in terms of film thickness and residence time distribution by numerical simulation and experiment.Falling film flow of high viscosity fluids was found to be steady on a vertical wavy wall in the presence of the large film thickness.The comparison between numerical simulation and experiment for the film thickness both in crest and trough of wavy wall showed good agreement.The simulation results of average residence time of falling film flow with different viscous fluids were also consistent with the experimental results.This work provides the initial insights of how to evaluate and optimize the falling film flow system of polymer fluid. 展开更多
关键词 FALLING FILM flow high viscosity polymer fluid RESIDENCE time distribution FILM thickness Numerical simulation
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部