Design of handheld terminal for shock wave pressure measurement system
1
作者 石晓丹 夏永乐 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2015年第2期169-174,共6页
Considering that it is difficult to monitor the measurement system and amend the test parameters on the scene in shock wave overpressure measurement and it is inconvenient to operate and carry traditional PC in outdoo... Considering that it is difficult to monitor the measurement system and amend the test parameters on the scene in shock wave overpressure measurement and it is inconvenient to operate and carry traditional PC in outdoor experiments, a new handheld terminal for shock wave pressure measurement system based on ARM is designed, The handheld terminal, whose ap- plication program is developed by the software of Qt, can control the measurement system by Wi-Fi and perform the functions of monitoring the system state, transmitting the data by wireless and displaying waveforms. To prevent data loss, USB inter- face is designed to read the data The test results show that the designed handheld terminal has good stability and reliability in several explosion experiments. 展开更多
关键词 shock wave handheld terminal QT
在线阅读 下载PDF
The Jamaica Handheld Ultrasound Project:a novel longitudinal point-of-care ultrasound curriculum in a resource-limited setting
2
作者 Maxime Montour Pranali Sheth +16 位作者 Steve Foo Simone French Tawanda Jones Giselle Watt Brian Kohen Aamir Bandagi Ariella Gartenberg Michael Halperin Trudy-Ann Johnson-Hylton Jason Ifill Alyssia McEwan Jonathan Maik Michelle Montenegro Rie Seu Nicole Leonard-shiu Hugh Wong Trevor Dixon 《World Journal of Emergency Medicine》 2025年第3期262-265,共4页
Point-of-care ultrasound(POCUS) is recognized as a valuable diagnostic tool,especially in resourcelimited settings(RLS).POCUS provides rapid diagnostic information that enables health professionals to make critical de... Point-of-care ultrasound(POCUS) is recognized as a valuable diagnostic tool,especially in resourcelimited settings(RLS).POCUS provides rapid diagnostic information that enables health professionals to make critical decisions at the bedside.^([1]) Despite the welldocumented benefits of POCUS,access to longitudinal,comprehensive training programs and a lack of trainee feedback are barriers to the widespread use of this technology in such settings.^([2]) 展开更多
关键词 health professionals point care ultrasound curriculum technology training feedback Jamaica handheld ultrasound resource limited settings longitudinal
暂未订购
V_(2)CT_(x) MXene-powered handheld SERS biosensor for the viral antigen test
3
作者 Meng-Nan Li Bo Cao +10 位作者 Yan-Ling Wang Hang Zhou Hai-Xu Yao Yuan Gao Xi-Wei Zhuang Jian-Lei Liu Chi-Jia Zeng Susan Zhou Da-Ling Zhu Jian Ma Fei-Yun Cui 《Rare Metals》 2025年第9期6442-6455,共14页
The intrinsic property of MXenes to adsorb dyes with high Raman scattering cross-sections makes them promising candidates for surface-enhanced Raman scattering(SERS)biosensors.In the study,we report a vanadium carbide... The intrinsic property of MXenes to adsorb dyes with high Raman scattering cross-sections makes them promising candidates for surface-enhanced Raman scattering(SERS)biosensors.In the study,we report a vanadium carbide MXene(V_(2)CT_(x))-based SERS biosensor tag,V_(2)CT_(x)@Thi(thionine)@Au NPs(gold nanoparticles)-Ab(antibody),owing to its large interlayer spacing and superior dye adsorption capacity.The tag V_(2)CT_(x)@Thi@Au NPs-Ab was fully characterized and validated,demonstrating a significantly enhanced Raman signal through both electromagnetic and chemical enhancement mechanisms.Using a handheld Raman spectrometer as a readout tool,the developed handheld SERS biosensor was successfully applied for the detection of viral antigens.The biosensor exhibited excellent linearity(1.562–100 nM)and achieved a low limit of detection(LOD)1.562 nM.Moreover,the biosensor demonstrated good selectivity and stability for detecting the target S protein in saliva samples.Our study highlights the potential of V_(2)CT_(x)MXene as a powerful material for handheld SERS biosensors,paving the way for portable and efficient viral diagnostics. 展开更多
关键词 Surface-enhanced Raman scattering(SERS) MXenes Vanadium carbide(V_(2)CT_(x)) Viral antigen handheld Raman detection
原文传递
Screening of unknown atrial fibrillation through handheld device in the elderly 被引量:3
4
作者 Francesco Rivezzi Riccardo Vio +8 位作者 Claudio Bilato Leopoldo Pagliani Giampaolo Pasquetto Salvatore Saccà Roberto Verlato Federico Migliore Sabino Iliceto Vito Bossone Emanuele Bertaglia 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第8期495-501,共7页
Objective To estimate the prevalence of unknown atrial fibrillation(AF)in the elderly population of the Veneto Region,Italy.Methods 1820 patients aged≥65 years with no history of AF and not anticoagulated were enroll... Objective To estimate the prevalence of unknown atrial fibrillation(AF)in the elderly population of the Veneto Region,Italy.Methods 1820 patients aged≥65 years with no history of AF and not anticoagulated were enrolled in primary-care settings.They underwent an opportunistic electrocardiogram screening with a handheld device(My Diagnostick)designed to specifically detect AF.The electrocardiogram recordings were reviewed by the researchers,who confirmed the presence of AF.Results The device detected an arrhythmia in 143 patients,which was confirmed as AF in 101/143(70.6%),with an overall prevalence of AF of 5.5%(101/1820).Prevalence of unknown AF resulted in 3.6%in patients aged 65–74 years,and 7.5%in patients age 75 or older,and increased according to CHA2 DS2-VASc score:3.5%in patients with a score of 1 or 2,5.6%in patients with a score of 3,7.0%in patients with a score of 4,and 7.2%in patients with a score≥5.The detection rate was significantly higher in patients with mild symptoms compared to asymptomatic counterparts(24.1%vs.4.0%,P<0.0001).At multivariate analysis,congestive heart failure and age≥75 years-old were independent predictors for screen-detected AF.Conclusions An opportunistic screening with handheld device revealed an unexpectedly high prevalence of unknown AF in elderly patients with mild symptoms.Prevalence increased with age and CHA2DS2-VASc score. 展开更多
关键词 Atrial fibrillation handheld electrocardiogram Primary care SCREENING Stroke prevention
暂未订购
A new handheld fundus camera combined with visual artificial intelligence facilitates diabetic retinopathy screening 被引量:4
5
作者 Shang Ruan Yang Liu +7 位作者 Wei-Ting Hu Hui-Xun Jia Shan-Shan Wang Min-Lu Song Meng-Xi Shen Da-Wei Luo Tao Ye Feng-Hua Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第4期620-627,共8页
AIM: To explore the performance in diabetic retinopathy(DR) screening of artificial intelligence(AI) system by evaluating the image quality of a handheld Optomed Aurora fundus camera in comparison to traditional table... AIM: To explore the performance in diabetic retinopathy(DR) screening of artificial intelligence(AI) system by evaluating the image quality of a handheld Optomed Aurora fundus camera in comparison to traditional tabletop fundus cameras and the diagnostic accuracy of DR of the two modalities. METHODS: Overall, 630 eyes were included from three centers and screened by a handheld camera(Aurora, Optomed, Oulu, Finland) and a table-top camera. Image quality was graded by three masked and experienced ophthalmologists. The diagnostic accuracy of the handheld camera and AI system was evaluated in assessing DR lesions and referable DR.RESULTS: Under nonmydriasis status, the handheld fundus camera had better image quality in centration, clarity, and visible range(1.47, 1.48, and 1.40) than conventional tabletop cameras(1.30, 1.28, and 1.18;P<0.001). Detection of retinal hemorrhage, hard exudation,and macular edema were comparable between the two modalities, in principle, with the area under the curve of the handheld fundus camera slightly lower. The sensitivity and specificity for the detection of referable DR with the handheld camera were 82.1%(95%CI: 72.1%-92.2%) and 97.4%(95%CI: 95.4%-99.5%), respectively. The performance of AI detection of DR using the Phoebus Algorithm was satisfactory;however, Phoebus showed a high sensitivity(88.2%, 95%CI: 79.4%-97.1%) and low specificity(40.7%, 95%CI: 34.1%-47.2%) when detecting referable DR.CONCLUSION: The handheld Aurora fundus camera combined with autonomous AI system is well-suited in DR screening without mydriasis because of its high sensitivity of DR detection as well as its image quality, but its specificity needs to be improved with better modeling of the data. Use of this new system is safe and effective in the detection of referable DR in real world practice. 展开更多
关键词 diabetic retinopathy image quality handheld camera artificial intelligence
原文传递
A comparison of handheld and standard ultrasound in Swiss medical students 被引量:1
6
作者 Mark Slader Hayley Young +5 位作者 Margot Barker Kylie Prentice Katherine Bogaard Charlene Yuan Soheil Saadat Shadi Lahham 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2022年第2期85-90,共6页
BACKGROUND:The use of ultrasound(US)within healthcare has inspired the development of new US technology.There have been few studies comparing the use of handheld US to standard US for medical education.This research a... BACKGROUND:The use of ultrasound(US)within healthcare has inspired the development of new US technology.There have been few studies comparing the use of handheld US to standard US for medical education.This research aims to determine whether a handheld US device can provide a comparable primary learning experience to that of a standard US machine.METHODS:Over two days of instruction,participants were taught and evaluated on core US fundamentals.The standard group received instruction on standard US machines,while the handheld group received instruction on handheld US devices.Participants completed a qualitative survey regarding their experience.Six hundred and four images were obtained and graded by two emergency medicine physicians.RESULTS:A total of 119 Swiss medical students were enrolled in our study.There was no statistically significant difference in the US assessment measurements,except for faster endpoint septal separation(EPSS)vascular setup time in the handheld group(P=0.001).There was no statistically significant difference in participants’perceived difficulty of US learning(P=0.198),comfort level(P=0.188),or self-estimated capability to perform US in the future(P=0.442).There was no statistically significant difference in the percentage of correctly obtained images(P=0.211)or images that were clinically useful(P=0.256).The median quality score of images obtained by the standard group was eight compared to seven in handheld group(P<0.01).CONCLUSION:Our data suggest a handheld US machine can perform as well as a standard US machine as an educational tool despite sacrifices in image quality. 展开更多
关键词 handheld ultrasound Ultrasound education Switzerland Medical education
暂未订购
Assessment of handheld mobile terrestrial laser scanning for estimating tree parameters
7
作者 Cornelis Stal Jeff rey Verbeurgt +1 位作者 Lars De Sloover Alain De Wulf 《Journal of Forestry Research》 SCIE CAS CSCD 2021年第4期1503-1513,共11页
Sustainable forest management heavily relies on the accurate estimation of tree parameters.Among others,the diameter at breast height(DBH) is important for extracting the volume and mass of an individual tree.For syst... Sustainable forest management heavily relies on the accurate estimation of tree parameters.Among others,the diameter at breast height(DBH) is important for extracting the volume and mass of an individual tree.For systematically estimating the volume of entire plots,airborne laser scanning(ALS) data are used.The estimation model is frequently calibrated using manual DBH measurements or static terrestrial laser scans(STLS) of sample plots.Although reliable,this method is time-consuming,which greatly hampers its use.Here,a handheld mobile terrestrial laser scanning(HMTLS) was demonstrated to be a useful alternative technique to precisely and efficiently calculate DBH.Different data acquisition techniques were applied at a sample plot,then the resulting parameters were comparatively analysed.The calculated DBH values were comparable to the manual measurements for HMTLS,STLS,and ALS data sets.Given the comparability of the extracted parameters,with a reduced point density of HTMLS compared to STLS data,and the reasonable increase of performance,with a reduction of acquisition time with a factor of5 compared to conventional STLS techniques and a factor of3 compared to manual measurements,HMTLS is considered a useful alternative technique. 展开更多
关键词 Forest inventory DBH Airborne laser scanning Terrestrial laser scanning handheld mobile laser scanning Point cloud processing
在线阅读 下载PDF
An Analysis on Position Estimation, Drifting and Accumulated Error Accuracy during 3D Tracking in Electronic Handheld Devices
8
作者 Shanjidah Akhter Pahlwan Rabiul Islam +2 位作者 Latifun Ahsin Bhuiyan Mehedi Hasan A. F. M. Saifuddin Saif 《Journal of Computer and Communications》 2018年第4期65-75,共11页
This work focuses on a brief discussion of new concepts of using smartphone sensors for 3D painting in virtual or augmented reality. Motivation of this research comes from the idea of using different types of sensors ... This work focuses on a brief discussion of new concepts of using smartphone sensors for 3D painting in virtual or augmented reality. Motivation of this research comes from the idea of using different types of sensors which exist in our smartphones such as accelerometer, gyroscope, magnetometer etc. to track the position for painting in virtual reality, like Google Tilt Brush, but cost effectively. Research studies till date on estimating position and localization and tracking have been thoroughly reviewed to find the appropriate algorithm which will provide accurate result with minimum drift error. Sensor fusion, Inertial Measurement Unit (IMU), MEMS inertial sensor, Kalman filter based global translational localization systems are studied. It is observed, prevailing approaches consist issues such as stability, random bias drift, noisy acceleration output, position estimation error, robustness or accuracy, cost effectiveness etc. Moreover, issues with motions that do not follow laws of physics, bandwidth, restrictive nature of assumptions, scale optimization for large space are noticed as well. Advantages of such smartphone sensor based position estimation approaches include, less memory demand, very fast operation, making them well suited for real time problems and embedded systems. Being independent of the size of the system, they can work effectively for high dimensional systems as well. Through study of these approaches it is observed, extended Kalman filter gives the highest accuracy with reduced requirement of excess hardware during tracking. It renders better and faster result when used in accelerometer sensor. With the aid of various software, error accuracy can be increased further as well. 展开更多
关键词 3D Tracking Error ACCURACY Extended KALMAN Filter handheld Device Position Estimation Sensor Virtual REALITY AUGMENTED REALITY
暂未订购
Handheld 3D Scanner for Small Objects Using Kinect
9
作者 Chia-Chi Hsu Chung-Lin Huang 《Journal of Electronic Science and Technology》 CAS CSCD 2016年第4期377-383,共7页
This paper presents a handheld 3D vision-based scanner for small objects by using Kinect. It is different from the previous color-glove-based approaches which require segmenting the target object. First, we eliminate ... This paper presents a handheld 3D vision-based scanner for small objects by using Kinect. It is different from the previous color-glove-based approaches which require segmenting the target object. First, we eliminate the noises and the outliers caused by holding hands. Second, we apply Kinect-fusion algorithm and truncated signed distance function (TSDF) to represent 3D surfaces. Third, we propose a modified integration strategy to eliminate the hand effect. Fourth, we take advantage of the parallel computation of GPUs for real-time operation. The major contributions of this paper are (1) the registration precision is improved, (2) the oflline amendment and loop closure operation are not required, and (3) concave 3D object reconstruction is feasible. 展开更多
关键词 handheld 3D scanning Kinect-fusion Truncated signed distance function (TSDF).
在线阅读 下载PDF
Role of Wireless Handheld Technology by Nurses in Healthcare Environment
10
作者 Abdul Hafeez-Baig Raj Gururajan 《Computer Technology and Application》 2012年第8期550-557,共8页
One of the emerging technologies is wireless handheld technology. Implication of these devices is enormous for business community and healthcare domain is not an exception to this phenomena. This research paper provid... One of the emerging technologies is wireless handheld technology. Implication of these devices is enormous for business community and healthcare domain is not an exception to this phenomena. This research paper provides some useful findings about the use of PDA's in the healthcare environment through actual usage of PDA in the healthcare ward. A qualitative and quantitative approach is adopted to explore these phenomena due to the exploratory nature of the research. Findings of this study identify some of the motivators and issues associated with the wireless handheld technology in healthcare environment. Furthermore, it is also found that these wireless handheld devices can help to improve the quality of care through better decision making processes. This study is limited to only one sate of Australian and further research is needed to see the implication of the findings to wider community and other domains in the Australian environment. 展开更多
关键词 Smart technology ICT (information and communication technology) wireless handheld devices healthcare adoption andactual use decision.
在线阅读 下载PDF
矿用锚网绑扎装置手持执行器传动系统的设计与应用
11
作者 田立勇 刘毅 +3 位作者 于宁 杨秀宇 包佳豪 张海建 《工程设计学报》 北大核心 2025年第6期845-855,共11页
针对煤矿掘进工作面人工绑扎锚网效率低的问题,提出了一种矿用锚网绑扎装置。手持执行器是矿用锚网绑扎装置的终端执行器,为深入理解其工作机理并验证其设计可靠性,利用SolidWorks软件和ANSYS软件分别对绑扎机构的送丝、切丝与拧丝过程... 针对煤矿掘进工作面人工绑扎锚网效率低的问题,提出了一种矿用锚网绑扎装置。手持执行器是矿用锚网绑扎装置的终端执行器,为深入理解其工作机理并验证其设计可靠性,利用SolidWorks软件和ANSYS软件分别对绑扎机构的送丝、切丝与拧丝过程进行了仿真分析,得出工作过程中送丝齿轮的峰值转矩为0.19 N·m,切丝片的峰值转矩为0.54 N·m,拧丝轴的峰值转矩为0.40 N·m。运用ADAMS软件对绑扎机构的传动系统进行了多体动力学仿真,得到了传动部件运行的速度特性曲线以及齿轮啮合传递的负载特性曲线。基于ANSYS软件对绑扎机构的齿轮啮合运动进行了有限元仿真分析,得出了啮合过程中齿轮结合面的应力分布云图,并根据计算的许用应力对齿轮的接触疲劳强度和弯曲疲劳强度进行了校核与验证。最后,搭建了锚网绑扎装置样机与手持执行器输入测试平台,并开展了绑扎性能验证实验。实验结果表明:手持执行器的性能与仿真分析结果基本吻合,绑扎动作连贯高效,单个绑扎操作循环用时1.8 s,绑扎效果符合设计要求且满足实际使用需求。研究结果为矿用锚网绑扎装置的优化设计与工程应用提供了理论依据。 展开更多
关键词 锚网绑扎 手持执行器 绑扎机构 传动系统 仿真分析
在线阅读 下载PDF
用于物化探测网布设的GPS航点生成方法与实现
12
作者 张琪 刘多朝 张万仁 《物探与化探》 2025年第1期200-205,共6页
测网布设是物化探勘查的先行工作内容,手持GPS的广泛应用给中小比例尺物化探野外勘查的导航定位带来了极大的便利。本文从坐标系转换的基础理论出发,面向物化探勘查中规则和不规则两类设计测网,提出了一种可生成大批量航点的方法,并编... 测网布设是物化探勘查的先行工作内容,手持GPS的广泛应用给中小比例尺物化探野外勘查的导航定位带来了极大的便利。本文从坐标系转换的基础理论出发,面向物化探勘查中规则和不规则两类设计测网,提出了一种可生成大批量航点的方法,并编制了相应的计算软件。该软件界面设计简洁,操作便利,无须借助第三方工具软件即可快捷地生成适合于重磁电测量、土壤测量、水系沉积物测量等方法的设计测网,用于野外作业时导航。 展开更多
关键词 坐标系 WGS-84 手持GPS 测网布设 规则网 不规则网
在线阅读 下载PDF
手持式结构光扫描系统设计与玉米叶面积提取 被引量:1
13
作者 彭星硕 杨悦 +2 位作者 张永亮 郭荣赓 耿楠 《农业机械学报》 北大核心 2025年第3期111-118,128,共9页
基于三维点云的叶面积提取方法具有非接触、高效率和高精度优势,能够更好地满足现代农业对叶面积快速获取和精准评估的需求。以大田全生育期夏玉米为研究对象,通过自主设计的手持式结构光作物三维扫描仪,采集夏玉米全生育期点云数据,并... 基于三维点云的叶面积提取方法具有非接触、高效率和高精度优势,能够更好地满足现代农业对叶面积快速获取和精准评估的需求。以大田全生育期夏玉米为研究对象,通过自主设计的手持式结构光作物三维扫描仪,采集夏玉米全生育期点云数据,并提出了点云配准、去噪和下采样等预处理流程。随后,应用点云分割网络对玉米作物器官点云进行了精确分割,成功提取了玉米叶片点云数据,并提取了叶面积。结果表明,分割网络在点云分割精度方面表现优异,叶片点云精确率、召回率、F1分数和交并比指标均超过95%,其他器官分割指标也均高于75%。不同生育期叶面积提取结果存在显著差异。在苗期、拔节期、全生育期模型表现较好,R^(2)分别为0.9062、0.9838、0.9949,均方根误差分别为221.34、172.77、206.64 cm^(2);但在成熟期,模型表现显著下降,R^(2)降至0.5178,RMSE上升至209.32 cm^(2)。不同施肥量下,叶面积提取结果整体良好,R^(2)均高于0.98。随着施肥量变化,均方根误差呈先下降后上升趋势,分别为176.38、106.36、110.18、270.34 cm^(2)。基于本文设计的设备和方法,能够准确有效地提取大田单株玉米叶面积,为智慧农业和表型机器人提供技术支持。 展开更多
关键词 夏玉米 生育期 叶面积 三维点云 点云分割 手持式结构光扫描系统
在线阅读 下载PDF
术中手持细胞级显微镜系统在甲状腺癌手术中的应用价值探索 被引量:1
14
作者 饶良蜜 吴德林 +3 位作者 王子康 宛凌峰 耿瑞 马小鹏 《中国实用医药》 2025年第15期74-77,共4页
目的探讨手持细胞级显微镜系统(EndoSCell^(TM)系统)在甲状腺癌手术中的应用价值。方法选取9例行手术治疗的甲状腺癌患者,术中通过手持EndoSCell^(TM)系统实时扫描原发灶、喉返神经、气管及甲状旁腺等表面以观察肿瘤组织,通过荧光素钠... 目的探讨手持细胞级显微镜系统(EndoSCell^(TM)系统)在甲状腺癌手术中的应用价值。方法选取9例行手术治疗的甲状腺癌患者,术中通过手持EndoSCell^(TM)系统实时扫描原发灶、喉返神经、气管及甲状旁腺等表面以观察肿瘤组织,通过荧光素钠和亚甲蓝溶液对可疑区域染色,然后使用显微镜进行扫描。以术后常规病理为金标准,观察EndoSCell^(TM)系统扫描判断甲状腺癌原发灶的准确性;EndoSCell^(TM)系统扫描成像喉返神经、气管及甲状旁腺的成功率。结果9例患者的原发灶及重要结构均成功成像(100%),检测到1例气管浆膜残留癌和1例喉返神经外膜受累患者,经精准切除后保留功能结构。术后随访半年无并发症、复发及转移。结论手持EndoSCell^(TM)系统能实现细胞级实时检测,为侵袭性甲状腺癌精准切除提供客观依据,在R0切除基础上避免盲目扩大切除范围,该技术具有良好的临床应用前景。 展开更多
关键词 甲状腺癌 术中 手持细胞级显微镜系统 荧光成像技术
暂未订购
智能化PDA手持系统在静脉用药调配中心退药环节中的应用效果评价 被引量:1
15
作者 严大鹏 陈继涢 +3 位作者 朱振茂 曾娜婷 叶岩荣 姜维文 《中国临床药学杂志》 2025年第2期107-111,共5页
目的评价智能化PDA手持系统在静脉用药调配中心(PIVAS)退药环节中的应用效果。方法收集2022年1月至2023年12月我院PIVAS的部门内差登记表、部门排班表及部门日常工作记录表,将2022年(智能化PDA手持系统应用前)数据作为对照组,2023年(智... 目的评价智能化PDA手持系统在静脉用药调配中心(PIVAS)退药环节中的应用效果。方法收集2022年1月至2023年12月我院PIVAS的部门内差登记表、部门排班表及部门日常工作记录表,将2022年(智能化PDA手持系统应用前)数据作为对照组,2023年(智能化PDA手持系统应用后)数据作为试验组。通过对比2组退药差错率、退药工作耗费时间、参与退药的人数以及因退药错误导致的药品损耗率等指标,评价PDA手持系统的实际应用效果。结果与对照组比较,试验组的退药差错发生率显著降低(1.01%vs 0.18%,P<0.05),每月退药工作耗费时间明显缩短[(120.96±10.90)h vs(40.10±5.26)h,P<0.05],参与退药人次数明显减少(1825人次vs 548人次,P<0.05),以及因退药未找出而导致的药品损耗量明显减少(398袋vs 55袋,P<0.05)。结论智能化PDA手持系统的应用,可有效提高PIVAS工作效率,减少差错,同时有效避免因退药未找出而出现的药品损耗。 展开更多
关键词 智能化PDA手持系统 自动化建设 静脉用药集中调配中心 工作差错
原文传递
铁路5G-R手持智能终端安全管控技术方案研究 被引量:1
16
作者 林永全 蒋笑冰 张海睿 《铁道通信信号》 2025年第1期10-16,共7页
为提升铁路5G-R手持智能终端的安全性,亟需研究满足铁路5G-R系统应用需求的手持智能终端安全管控技术方案。概述手持智能终端的发展历程、应用场景和安全管控需求,在公网手持智能终端安全管控技术方案的基础上,设计铁路5G-R手持智能终... 为提升铁路5G-R手持智能终端的安全性,亟需研究满足铁路5G-R系统应用需求的手持智能终端安全管控技术方案。概述手持智能终端的发展历程、应用场景和安全管控需求,在公网手持智能终端安全管控技术方案的基础上,设计铁路5G-R手持智能终端安全管控技术方案。该方案符合铁路通信管理要求,兼容通用和定制的5G-R手持智能终端;可以对终端进行灵活管控和监控,以满足不同终端的使用差异和安全防护要求;在服务侧具有接入不同终端的安全管理能力和综合服务能力,既满足当前铁路5G-R系统技术规范,也符合未来铁路对手持智能终端的安全管理要求。 展开更多
关键词 5G-R系统 手持智能终端 安全管理 移动设备管理 防病毒
在线阅读 下载PDF
安全芯片SM2签名在北斗手持终端短报文系统中的实现
17
作者 刘明 李文光 +2 位作者 高凯凯 徐国桐 吕权 《北斗与空间信息应用技术》 2025年第5期55-58,共4页
本文围绕安全芯片SM2签名应用于北斗手持终端短报文系统进行了研究,系统地阐述了该系统的实现流程,涉及到系统需求,安全芯片的适用条件和关键施工技术。通过搭建仿真模型、设置有关参数、划分技术阶段等方式进行模拟实验。通过对数据表... 本文围绕安全芯片SM2签名应用于北斗手持终端短报文系统进行了研究,系统地阐述了该系统的实现流程,涉及到系统需求,安全芯片的适用条件和关键施工技术。通过搭建仿真模型、设置有关参数、划分技术阶段等方式进行模拟实验。通过对数据表格进行仿真分析,证实了安全芯片SM2签名策略在增强数据传输的机密性、完整性和身份验证方面具有显著效果。现场监测的数据表明,系统运行效果较好,所提出的方案显著提高了北斗短报文系统数据传输的安全性,有较大的应用价值。 展开更多
关键词 安全芯片 SM2签名 北斗手持终端 短报文系统
在线阅读 下载PDF
乳腺超声诊断系统联合手持高频超声在乳腺癌检查中的应用价值
18
作者 王恋培 《中外医药研究》 2025年第21期146-148,共3页
目的:探究乳腺超声诊断系统联合手持高频超声在乳腺癌检查中的应用价值。方法:选取2024年1—6月合肥市播州区人民医院就诊的1501例存在乳腺肿块的女性为研究对象,接受手持高频超声、乳腺超声诊断系统检查。以临床综合检查结果为“金标准... 目的:探究乳腺超声诊断系统联合手持高频超声在乳腺癌检查中的应用价值。方法:选取2024年1—6月合肥市播州区人民医院就诊的1501例存在乳腺肿块的女性为研究对象,接受手持高频超声、乳腺超声诊断系统检查。以临床综合检查结果为“金标准”,比较两种超声技术单独及联合诊断乳腺癌的价值。此外,比较两种超声技术检查时间。结果:临床综合检查结果显示,1501例存在乳腺肿块的女性中,确诊乳腺癌59例。手持高频超声检查诊断乳腺癌的准确度高于乳腺超声诊断系统检查(P<0.05);联合检查及手持高频超声检查诊断乳腺癌的灵敏度高于乳腺超声诊断系统检查(P<0.05),联合检查诊断乳腺癌的灵敏度高于手持高频超声检查(P<0.05);三种检查方式诊断乳腺癌的特异度比较,无统计学差异(P>0.05)。乳腺超声诊断系统检查时间短于手持高频超声检查(P<0.001)。结论:手持高频超声检查诊断乳腺癌的准确度、灵敏度较乳腺超声诊断系统高,但乳腺超声诊断系统诊断时间短,两种方法联合应用可提高灵敏度。 展开更多
关键词 乳腺癌 手持高频超声 乳腺超声诊断系统
暂未订购
手持式ATP生物荧光检测仪研制 被引量:8
19
作者 周爱玉 罗金平 +3 位作者 岳伟伟 何保山 杨庆德 蔡新霞 《传感技术学报》 CAS CSCD 北大核心 2008年第4期543-546,共4页
针对微量三磷酸腺苷(ATP)检测需求,利用生物荧光技术,设计了一种手持式ATP检测仪。该检测仪以小型光电倍增管PMT为光电转换器件,通过有效的干扰屏蔽和信号采集放大电路设计,实现了ATP反应释放微弱荧光信号的采集。以10^-15-10^-9mol/... 针对微量三磷酸腺苷(ATP)检测需求,利用生物荧光技术,设计了一种手持式ATP检测仪。该检测仪以小型光电倍增管PMT为光电转换器件,通过有效的干扰屏蔽和信号采集放大电路设计,实现了ATP反应释放微弱荧光信号的采集。以10^-15-10^-9mol/L标准ATP样品为检测对象,以大型分析仪器F4500为对比仪器,进行了梯度对比实验,结果表明,本仪器可检测最低ATP浓度为10^-14mol/L,是F4500最低检测限的1/100。检测时间为10s时,在10v-14-10^-9mol/L浓度范围内,本仪器响应值与标准ATP样品浓度在对数坐标下线性相关,相关系数达到了0.9902。 展开更多
关键词 三磷酸腺苷 生物荧光 手持式检测仪 光电倍增管
在线阅读 下载PDF