In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture dev...In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture device (DCSD). A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group). Patients in the DCSD group were anesthetized with compound 5% lidocaine cream, the others with a 2% lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were significantly lower in the Shang ring and suture device groups compared to the conventional group (P 〈 0.001). Intra-operative pain was less in the suture device group compared With the other two groups (P 〈 0.001); whereas post-operative pain was higher in the conventional group compared to the other two groups (P 〈 0.001). Patients in the suture device (80.57%) and Shang ring (73,57%) groups were more satisfied with penile appearances compared with the conventional circumcision group (20.06%, P 〈 0.05). Patients in suture device group also healed markedly faster than the conventional group (P 〈 0.01). The overall satisfaction rate was better in the suture device group (78.66%) compared with the conventional (47.13%) and Shang ring (50.00%) groups (P 〈 0.05). The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra-operative and post-operative pain and improved patient satisfaction with the cosmetic appearances.展开更多
This systematic review assessed the safety and efficacy of the disposable circumcision suture device (DCSD) and conventional circumcision (CC) in the treatment of redundant prepuce and phimosis. Two independent re...This systematic review assessed the safety and efficacy of the disposable circumcision suture device (DCSD) and conventional circumcision (CC) in the treatment of redundant prepuce and phimosis. Two independent reviewers conducted a literature search for randomized controlled trials (RCTs) using the DCSD and CC for the treatment of redundant prepuce or phimosis in China and abroad. Nine RCTs (1898 cases) were included. Compared with the CC group, the DCSD group had a shorter operative time (standardized mean difference [SMD] = -21.44; 95% confidence intervals [95% CIs] [-25.08, -17.79]; P 〈 0.00001), shorter wound healing time (SMD = -3.66; 95% CI [-5.46, -1.85]; P 〈 0.0001), less intraoperative blood loss (SMD = -9.64; 95% CI [-11.37, -7.90]; P 〈 0.00001), better cosmetic penile appearance (odds ratio [OR] =8.77; 95% CI [5.90, 13.02]; P 〈 0.00001), lower intraoperative pain score, lower 24-h postoperative pain score, lower incidence of infection, less incision edema, and fewer adverse events. There were no differences between the CC and DCSD groups in the incidences of dehiscence, or hematoma. The results of this meta-analysis indicate that the DCSD appears to be safer and more effective than CC. However, additional high-quality RCTs with larger study populations are needed.展开更多
A 27-year-old man with recurrent right lower quadrant pain was admitted to our hospital. Ultrasonography and computed tomography examination of the abdomen revealed a target sign in the ascending colon, which was comp...A 27-year-old man with recurrent right lower quadrant pain was admitted to our hospital. Ultrasonography and computed tomography examination of the abdomen revealed a target sign in the ascending colon, which was compatible with the diagnosis of cecal intussusception. The intussusception was spontaneously resolved at that time, but it relapsed 6 mo later. The patient underwent a successful colonoscopic disinvagination; there was no evidence of neoplastic or inflammatory lesions in the colon and terminal ileum. The patient underwent laparoscopic surgery for recurring cecal intussusception. During laparoscopy, we observed an unfixed cecum on the posterior peritoneum(i.e. a mobile cecum). Thus, we performed laparoscopic appendectomy and cecopexy with a lateral peritoneal flap using a barbed wound suture device. The patient's post-operative course was uneventful, and he continued to do well without recurrence at 10 mo after surgery. Laparoscopic cecopexy using a barbed wound suture device is a simple and reliable procedure that can be the treatment of choice for recurrent cecal intussusception associated with a mobile cecum.展开更多
Among surgical procedures,suturing is considered simple.However,in some situations,suturing is not easy or feasible.Here,we present proof of concept of a new self-tightening needle-less suture made of a NiTi alloy.The...Among surgical procedures,suturing is considered simple.However,in some situations,suturing is not easy or feasible.Here,we present proof of concept of a new self-tightening needle-less suture made of a NiTi alloy.The new device is designed to overcome two demanding steps of traditional suturing:needle introduction and manual knotting.Our novel suture is composed only of a short NiTi wire that is able to change shape by exploiting a thermoelastic phase transition.This shape change is achieved by increasing the temperature from that of the operating room(e.g.,20-22℃)to 32℃using warm water.Suturing consists of two steps:suture introduction,in which the suture is in an open configuration,and shape recovery(i.e.,closed configuration).The closed configuration is maintained at human body temperature thanks to peculiar pseudoelastic properties of the NiTi material.Finally,thermal and functional characterization verified the simplicity and effectiveness of the proposed device.展开更多
文摘In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture device (DCSD). A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group). Patients in the DCSD group were anesthetized with compound 5% lidocaine cream, the others with a 2% lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were significantly lower in the Shang ring and suture device groups compared to the conventional group (P 〈 0.001). Intra-operative pain was less in the suture device group compared With the other two groups (P 〈 0.001); whereas post-operative pain was higher in the conventional group compared to the other two groups (P 〈 0.001). Patients in the suture device (80.57%) and Shang ring (73,57%) groups were more satisfied with penile appearances compared with the conventional circumcision group (20.06%, P 〈 0.05). Patients in suture device group also healed markedly faster than the conventional group (P 〈 0.01). The overall satisfaction rate was better in the suture device group (78.66%) compared with the conventional (47.13%) and Shang ring (50.00%) groups (P 〈 0.05). The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra-operative and post-operative pain and improved patient satisfaction with the cosmetic appearances.
文摘This systematic review assessed the safety and efficacy of the disposable circumcision suture device (DCSD) and conventional circumcision (CC) in the treatment of redundant prepuce and phimosis. Two independent reviewers conducted a literature search for randomized controlled trials (RCTs) using the DCSD and CC for the treatment of redundant prepuce or phimosis in China and abroad. Nine RCTs (1898 cases) were included. Compared with the CC group, the DCSD group had a shorter operative time (standardized mean difference [SMD] = -21.44; 95% confidence intervals [95% CIs] [-25.08, -17.79]; P 〈 0.00001), shorter wound healing time (SMD = -3.66; 95% CI [-5.46, -1.85]; P 〈 0.0001), less intraoperative blood loss (SMD = -9.64; 95% CI [-11.37, -7.90]; P 〈 0.00001), better cosmetic penile appearance (odds ratio [OR] =8.77; 95% CI [5.90, 13.02]; P 〈 0.00001), lower intraoperative pain score, lower 24-h postoperative pain score, lower incidence of infection, less incision edema, and fewer adverse events. There were no differences between the CC and DCSD groups in the incidences of dehiscence, or hematoma. The results of this meta-analysis indicate that the DCSD appears to be safer and more effective than CC. However, additional high-quality RCTs with larger study populations are needed.
文摘A 27-year-old man with recurrent right lower quadrant pain was admitted to our hospital. Ultrasonography and computed tomography examination of the abdomen revealed a target sign in the ascending colon, which was compatible with the diagnosis of cecal intussusception. The intussusception was spontaneously resolved at that time, but it relapsed 6 mo later. The patient underwent a successful colonoscopic disinvagination; there was no evidence of neoplastic or inflammatory lesions in the colon and terminal ileum. The patient underwent laparoscopic surgery for recurring cecal intussusception. During laparoscopy, we observed an unfixed cecum on the posterior peritoneum(i.e. a mobile cecum). Thus, we performed laparoscopic appendectomy and cecopexy with a lateral peritoneal flap using a barbed wound suture device. The patient's post-operative course was uneventful, and he continued to do well without recurrence at 10 mo after surgery. Laparoscopic cecopexy using a barbed wound suture device is a simple and reliable procedure that can be the treatment of choice for recurrent cecal intussusception associated with a mobile cecum.
基金Funding was provided by Regione Lombardia(Grant No.BANDO MISE Brevetti+N.BRE0000721).
文摘Among surgical procedures,suturing is considered simple.However,in some situations,suturing is not easy or feasible.Here,we present proof of concept of a new self-tightening needle-less suture made of a NiTi alloy.The new device is designed to overcome two demanding steps of traditional suturing:needle introduction and manual knotting.Our novel suture is composed only of a short NiTi wire that is able to change shape by exploiting a thermoelastic phase transition.This shape change is achieved by increasing the temperature from that of the operating room(e.g.,20-22℃)to 32℃using warm water.Suturing consists of two steps:suture introduction,in which the suture is in an open configuration,and shape recovery(i.e.,closed configuration).The closed configuration is maintained at human body temperature thanks to peculiar pseudoelastic properties of the NiTi material.Finally,thermal and functional characterization verified the simplicity and effectiveness of the proposed device.