期刊文献+
共找到60篇文章
< 1 2 3 >
每页显示 20 50 100
Ilizarov external fixators for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ
1
作者 谢鸣 《外科研究与新技术》 2011年第2期114-114,共1页
Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of o... Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of obsolete calcaneal 展开更多
关键词 Ilizarov external fixators for maluninon of obsolete calcaneal fracture of Stephen Type
暂未订购
Impact of the Ilizarov apparatus on external fixation: Current modifications of the 75-year-old orthopedic tool
2
作者 Ilia Sutyagin Tatiana A Malkova 《World Journal of Orthopedics》 2025年第11期44-55,共12页
The Ilizarov apparatus was designed by its author 75 years ago and addresses a wide range of orthopedic conditions.Its classical assemblies are still self-sufficient and versatile.However,certain clinical scenarios re... The Ilizarov apparatus was designed by its author 75 years ago and addresses a wide range of orthopedic conditions.Its classical assemblies are still self-sufficient and versatile.However,certain clinical scenarios require a more specialized approach,and some groups of patients may benefit from customized Ilizarov constructs.Engineering science has designed various external fixators for orthopedic purposes,and some of those have become the gold standard for specific clinical tasks.We aimed to determine the current state and novel modifications of specialized external fixators for specific clinical situations which are based on the principles of the Ilizarov method.They are half-pin-based fixators for temporal fracture fixation,ring or hybrid devices for gradual deformity correction,and compression-distraction devices tailored for definite limb segments.Gradual correction of deformities can be achieved with external hexapods incorporating universal reduction units.Alternatively,external fixators with special connection mechanisms are able to provide independent movement of the rings in six degrees of freedom.Deformity correction can be performed with combined or sequential use of external and internal fixators.Special devices were developed for moving the split fragment for revascularization of the tibia.The units of external frames on the foot were modified to consider its complex anatomy and the clinical needs ranging from correction of multi-plane deformities,joint arthrodesis to distraction arthroplasty.Mini-fixators are compact external fixators for small bones of the hand and foot.The varieties of external fixators based on the Ilizarov principles have been designed to fulfill an ultimate goal of improving treatment outcomes. 展开更多
关键词 Ilizarov apparatus external fixation Distraction osteogenesis Bone lengthening Bone deformity Hexapod frame Mini-fixator
暂未订购
Effectiveness of the induced membrane technique in aseptic and infected long-bone defect management: Are there any differences?
3
作者 Alexander L Shastov Sergey N Kolchin Tatiana A Malkova 《World Journal of Orthopedics》 2025年第7期16-28,共13页
Management of post-traumatic long-bone defects remains relevant and cha-llenging despite the rapid development of approaches to their treatment.Do-minant positions are occupied by the Ilizarov method,bone autogenous g... Management of post-traumatic long-bone defects remains relevant and cha-llenging despite the rapid development of approaches to their treatment.Do-minant positions are occupied by the Ilizarov method,bone autogenous grafting and the Masquelet induced membrane technique(IMT).The IMT is aimed at reducing extensive defect treatment duration and for this reason has gained great popularity.However,the assessment of its effectiveness is difficult due to a limited number of clinical series.The varying clinical manifestations of bone defect severity do not allow a comprehensive evaluation of IMT effectiveness.One of them is infection in the defect area.The purpose of our literature review is an analysis of studies on IMT application in infected vs non-infected long-bone defects of the lower extremities published over the last 10 years.It focuses on the investigation of similarities and fundamental differences in the need for antibiotics,timing of spacer fixation,methods of collecting donor bone and fixators used for consolidation.The studies show that the IMT has been globally used in aseptic and osteomyelitic defects due to its clinical effectiveness.Authors’variations and improvements in its practical implementation indicate the ongoing development and the interest of researchers in this technique. 展开更多
关键词 Long bone NONUNION Defect Induced membrane technique Infection Spacer Intramedullary nail external fixator OSTEOMYELITIS
暂未订购
Ulnar lengthening in the treatment of forearm deformity caused by hereditary multiple exostoses in children
4
作者 Shuo Wang Huan-Rong Liu +5 位作者 Kai-Tai Zou Feng Gao Shang-Yu Wang Blessing Mutasa Jin Li Pan Hong 《World Journal of Orthopedics》 2025年第7期37-45,共9页
Hereditary multiple exostoses(HME)is an autosomal dominant bone disorder characterized by abnormal bone development.HME mostly involves the forearm,resulting in forearm deformities,limited functional activities,etc.Cu... Hereditary multiple exostoses(HME)is an autosomal dominant bone disorder characterized by abnormal bone development.HME mostly involves the forearm,resulting in forearm deformities,limited functional activities,etc.Currently,there are multiple surgical methods including tumor resection with or without ulnar osteotomy and lengthening,simple radial head resection and distal radial hemiepiphysiodesis,but the optimal treatment remains controversial.Ulnar lengthening serves as an effective surgical intervention for forearm deformities in HME patients.This review examines its surgical techniques,complications,and timing of the operation to guide clinical decision-making for improving function and cosmetic outcomes. 展开更多
关键词 Hereditary multiple exostoses Forearm deformity Ulnar lengthening Ilizarov technique Distraction osteogenesis Radial head dislocation Pediatric orthopedics Postoperative complications OSTEOTOMY external fixation
暂未订购
External fixation is more suitable for intra-articular fractures of the distal radius in elderly patients 被引量:7
5
作者 Chuang Ma Qiang Deng +5 位作者 Hongwei Pu Xinchun Cheng Yuhua Kan Jing Yang Aihemaitijiang Yusufu Li Cao 《Bone Research》 SCIE CAS CSCD 2016年第1期39-47,共9页
The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters fol... The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after I week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P = 0.001), supination, (P = 0.047) and extension (P = 0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at I year. The plating group had a greater occurrence of wound infection (P = 0.043), tendonitis, (P = 0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the "gross motor" category (walking upstairs, bending over, walking 500 yards; P = 0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after I year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. 展开更多
关键词 MORE external fixation is more suitable for intra-articular fractures of the distal radius in elderly patients
暂未订购
Role of coatings and materials of external fixation pins on the rates of pin tract infection:A systematic review and meta-analysis 被引量:2
6
作者 Cristhopher Stoffel Bruno Eltz Mauro Jose Salles 《World Journal of Orthopedics》 2021年第11期920-930,共11页
BACKGROUND Infection at the pin tract is a frequent and feared complication of external fixators(EF).The type of pin material and coatings have been regarded as possibly influencing infection rates.Over the last 20 ye... BACKGROUND Infection at the pin tract is a frequent and feared complication of external fixators(EF).The type of pin material and coatings have been regarded as possibly influencing infection rates.Over the last 20 years,few prospective clinical studies and systematic reviews addressed the role of coated pins on the rate of pin site infection in human clinical studies.AIM To assess the EF literature over the past 20 years on the clinical benefits of pins manufactured from varied materials and coating systems and their possible role in pin tract infection rates.METHODS We performed a systematic review according to the PRISMA and PICOS guidelines using four scientific platforms:PubMed,LiLacs,SciELO,and Cochrane.We searched the literature for related publications over the past 20 years.RESULTS A literature search yielded 29 articles,among which seven met the inclusion criteria.These studies compared stainless-steel pins and pins coated with hydroxyapatite(HA),titanium and silver.The pin tract infection definitions were arbitrary and not standardized among studies.Most studies included a low number of patients in the analysis and used a short follow-up time.Three metaanalyses were carried out,comparing stainless steel vs silver pins,stainless steel vs HA-coated pins,and titanium vs HA-coated pins.None of this analysis resulted in statistically significant differences in pin tract infection rates.CONCLUSION Currently,no clinical evidence supports the advantage of EF pins manufactured with materials other than stainless steel or coated over uncoated pins in reducing the rates of pin tract infections.A standardized definition of pin tract infection in external fixation is still lacking. 展开更多
关键词 external fixator Pin tract infection Stainless steel pin Coated pin Coating systems Pin site infection
暂未订购
Internal fixator vs external fixator in the management of unstable pelvic ring injuries:A prospective comparative cohort study 被引量:3
7
作者 Mohamed Abo-Elsoud Mostafa I Awad +2 位作者 Mahmoud Abdel Karim Sherif Khaled Mohamed Abdelmoneim 《World Journal of Orthopedics》 2023年第7期562-571,共10页
BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using e... BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using either an anterior subcutaneous pelvis internal fixator(INFIX)or an anterior supra-acetabular external fixator(EXFIX)to manage an unstable anterior pelvic ring fracture.AIM To compare the functional and radiological outcomes and complications of INFIX vs EXFIX in managing unstable pelvic ring injuries.METHODS A prospective cohort study included 54 patients with unstable pelvic ring fractures.The patients were divided into two groups;the INFIX group,in which 30 cases were fixed by INFIX,and the EXFIX group,in which 24 patients were treated by EXFIX.The average age in the EXFIX group was 31.17 years(16-57 years),while in the INFIX group,it was 34.5 years(17-53 years).The study included 20(66.7%)males and 10(33.3%)females in the INFIX group and 10(41.7%)males and 14(58.3%)females in the EXFIX group.The radiological outcomes were evaluated using Matta and Tornetta's score,and the functional outcomes using the Majeed score.RESULTS The results revealed a statistically significant difference between both groups(P=0.013)regarding radiological outcomes,according to Matta and Tornetta's score in favor of the INFIX group.Sitting,standing,and walking abilities were measured at a 3-mo follow-up visit using Majeed score modules.It was significantly better among the INFIX group than the EXFIX group in all three modules.At the final follow-up,both groups had no statistically significant difference according to the Majeed score;92.35 in the INFIX group and 90.99 in the EXFIX group(P=0.513).A lower surgical site infection rate was noticed in the INFIX group(P=0.007).CONCLUSION Anterior subcutaneous pelvis INFIX is associated with better radiological outcomes and a lower infection rate than anterior supra-acetabular EXFIX in managing patients with unstable anterior pelvic ring fractures. 展开更多
关键词 Internal fixator external fixator UNSTABLE ANTERIOR PELVIC INJURIES
暂未订购
Formation process of extension knee joint contracture following external immobilization in rats 被引量:3
8
作者 Chen-Xu Zhou Feng Wang +2 位作者 Yun Zhou Qiao-Zhou Fang Quan-Bing Zhang 《World Journal of Orthopedics》 2023年第9期669-681,共13页
BACKGROUND Current research lacks a model of knee extension contracture in rats.AIM To elucidate the formation process of knee extension contracture.METHODS We developed a rat model using an aluminum external fixator.... BACKGROUND Current research lacks a model of knee extension contracture in rats.AIM To elucidate the formation process of knee extension contracture.METHODS We developed a rat model using an aluminum external fixator.Sixty male Sprague-Dawley rats with mature bones were divided into the control group(n=6)and groups that had the left knee immobilized with an aluminum external fixator for 1,2,and 3 d,and 1,2,3,4,6,and 8 wk(n=6 in each group).The passive extension range of motion,histology,and expression of fibrosis-related proteins were compared between the control group and the immobilization groups.RESULTS Myogenic contracture progressed very quickly during the initial 2 wk of immobilization.After 2 wk,the contracture gradually changed from myogenic to arthrogenic.The arthrogenic contracture progressed slowly during the 1^(st) week,rapidly progressed until the 3^(rd) week,and then showed a steady progression until the 4^(rd) week.Histological analyses confirmed that the anterior joint capsule of the extended fixed knee became increasingly thicker over time.Correspondingly,the level of transforming growth factor beta 1(TGF-β1)and phosphorylated mothers against decapentaplegic homolog 2(p-Smad2)in the anterior joint capsule also increased with the immobilization time.Over time,the cross-sectional area of muscle fibers gradually decreased,while the amount of intermuscular collagen and TGF-β1,p-Smad2,and p-Smad3 was increased.Unexpectedly,the amount of intermuscular collagen and TGF-β1,p-Smad2,and p-Smad3 was decreased during the late stage of immobilization(6-8 wk).The myogenic contracture was stabilized after 2 wk of immobilization,whereas the arthrogenic contracture was stabilized after 3 wk of immobilization and completely stable in 4 wk.CONCLUSION This rat model may be a useful tool to study the etiology of joint contracture and establish therapeutic approaches. 展开更多
关键词 Knee joint IMMOBILIZATION CONTRACTURE external fixator RATS
暂未订购
Early complications of preoperative external traction fixation in the staged treatment of tibial fractures:A series of 402 cases 被引量:1
9
作者 Jia-Zhao Yang Wan-Bo Zhu +1 位作者 Liu-Bing Li Qi-Rong Dong 《World Journal of Clinical Cases》 SCIE 2020年第20期4743-4752,共10页
BACKGROUND Different external skeletal fixators have been widely used in preoperative traction of high-energy tibial fractures prior to a definitive surgical treatment.However,the early complications associated with t... BACKGROUND Different external skeletal fixators have been widely used in preoperative traction of high-energy tibial fractures prior to a definitive surgical treatment.However,the early complications associated with this staged treatment for traction and soft tissue injury recovery have rarely been discussed.AIM To analyze the early complications associated with preoperative external traction fixation in the staged treatment of tibial fractures.METHODS A total of 402 patients with high-energy tibial fractures treated using preoperative external traction fixation at a Level 1 trauma center from 2014 to 2018 were enrolled in this retrospective study.Data regarding the demographic information,Tscherne soft tissue injury,fracture site,entry point placement,and duration of traction were recorded.Procedure-related complications such as movement and sensation disorder,vessel injury,discharge,infection,loosening,and iatrogenic fractures were analyzed.RESULTS The mean patient age was 42.5(18-71)years,and the mean duration of traction was 7.5(0-26)d.In total,19(4.7%)patients presented with procedure-related complications,including technique-associated complications in 6 patients and nursing-associated complications in 13.Differences in the incidence of complications with respect to sex,affected side,soft tissue injury classification,and fracture sites were not observed.However,the number of complications due to hammer insertion was significantly reduced than those due to drill insertions(2.9%vs 7.4%).CONCLUSION We found a low incidence of early complications related to the fixation.Furthermore,the complications were not significantly associated with the severity of the soft tissue injury and fracture site.Although relatively rough and more likely to cause pain,the number of complications associated with hammer insertion was significantly smaller than that of complications associated with drill insertion. 展开更多
关键词 Tibial fracture external fixation Bone traction COMPLICATIONS Vessels injury Nerve injury
暂未订购
BIOMECHANICAL STUDY ON UNILATERAL SINGLE-PLANE EXTERNAL FIXER 被引量:1
10
作者 刘国平 杜靖远 徐兆雄 《Chinese Medical Sciences Journal》 CAS CSCD 1995年第4期226-228,共3页
Six tibias removed from 30-40 years old males, who died in an accident for in less than 12 hours, were osteotomized at one-third supra-medium segment. They were fixed by an unilateral adjustable external fixer (UAEF),... Six tibias removed from 30-40 years old males, who died in an accident for in less than 12 hours, were osteotomized at one-third supra-medium segment. They were fixed by an unilateral adjustable external fixer (UAEF), to be used as a model of external fixation of tibial fracture (MEFTF). The compression. tension, torsion, antero-posterior and lateral bending strength, and the strength for vertically extracting the pins from the tibia were determined in the MEFTF. Within a certain range of load, the correlation of strain to stress was basically a linear relationship. These data provide a theoretical basis of biomechanics for the improvement of UAEF and for early exercises of fracture patients, such as extend-bending of the joint.raising the limb and walking with a walking stick. 展开更多
关键词 TIBIA external fixator BIOMECHANICS
暂未订购
Application of Virtual Reconstruction 3D-Printed External Fixation Helmet in Early Functional Treatment of Facial Fracture 被引量:1
11
作者 GE Weiwen WANG Yun +5 位作者 GE Kui WU Jiajun FAN Jingrian YANG Tianye WANG Qi XU Bing 《Journal of Shanghai Jiaotong university(Science)》 EI 2021年第3期368-371,共4页
Facial fracture repair is time-dependent.Early reduction and fixation after trauma help with later repair.Abnormal healing caused by delayed repair increases not only the difficulty of reconstruction,but also the risk... Facial fracture repair is time-dependent.Early reduction and fixation after trauma help with later repair.Abnormal healing caused by delayed repair increases not only the difficulty of reconstruction,but also the risk of aesthetic or functional defects.Digital technology was used to model local trauma in three dimensions.The fracture fragments were reset,and the facial shape was reconstructed on the reset model.After resampling,3D printing was used to construct a personalised external fixation helmet.Combined with the posterior nasal passage lift reduction technique,early reduction of the mid-face fractures was performed.Through the early application of a 3D-printed personalised external fixation helmet to a patient with a comprehensive fracture,the helmet manufacturing process and application methods were introduced,and the effect of this application was investigated.In the treatment of facial fractures,the early application of a 3D-printed personalised external fixation helmet is conducive to fracture reduction and fixation and reduces the difficulty of later reconstruction. 展开更多
关键词 external fixation helmet facial fracture functional reconstruction 3D printing
原文传递
Proximal tibial osteotomy for genu varum:Radiological evaluation of deformity correction with a plate vs external fixator 被引量:1
12
作者 S Ali Ghasemi David T Zhang +1 位作者 Austin Fragomen S Robert Rozbruch 《World Journal of Orthopedics》 2021年第3期140-151,共12页
BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using tw... BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using two different techniques:acute opening wedge correction using a plate and gradual correction with a monolateral external fixator.AIM To compare of the radiological results of two different techniques:acute opening wedge correction(a plate and screw)and gradual correction(external fixator).METHODS A total of 43 patients with plates and 36 patients with external fixators were included.All patients had moderate uniplanar varus deformities.We measured radiographic parameters,including the mechanical axis deviation(MAD),medial proximal tibial angle(MPTA),Caton-Deschamps Index(CDI),posterior proximal tibial angle,and joint line obliquity angle(JLOA).The accuracy of MAD correction was calculated based on a correction goal of neutral or overcorrection for medial compartment arthritis.RESULTS Demographics including age,body mass index,sex,and preoperative deformities were similar between the groups.The MAD significantly improved from 23.6 mm medial to the midline(SD=8.2 mm)to 6.9 mm lateral to the midline(SD=5.4 mm)(P<0.001).The accuracy of MAD correction did not differ between the groups and was 96.1%(SD=8.1%)in the plate group and 98.2%(SD=5.2%)in the external fixator group(P=0.18).The MPTA significantly improved from 83.9°(SD=2.9°)to 90.9°(SD=3.3°)(P<0.001),and the change was similar between the groups.Differences were noted in patella height,with a CDI change of-19.2%(SD=13.7%)and 3.1%(SD=8.0%)for the plate and external fixator groups,respectively(P<0.001).The change in JLOA was 1.6 degrees(SD=1.1 degrees)and 0.9 degrees(SD=0.9 degrees)for the plate and external fixator groups,respectively(P=0.04).CONCLUSION Reliable correction of moderate varus alignment was achieved with both the acute opening wedge technique with a plate and the gradual monolateral external fixator technique.The patellar height decreased with the open wedge plate technique.Joint line obliquity decreased to a greater degree with the open wedge plate technique,perhaps as a result of medial collateral ligament release.The appropriate technique should be selected based on surgeon and patient preferences;however,external fixation may be a better choice when the preservation of patellar height is deemed important. 展开更多
关键词 High tibial osteotomy external fixator Gradual correction Plate and screw Genu varum RADIOLOGICAL
暂未订购
HYBRID EXTERNAL FIXATOR FOR THE TREATMENT OF UNICAMERAL BONE CYSTS WITH PATHOLOGICAL FRACTURE IN THE PROXIMAL HUMERUS
13
作者 郭征 王臻 赵黎 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2004年第1期62-66,共5页
Objective: Unicameral bone cyst is a nonneoplasticbone lesion characterized by its tenacity and risk ofrecurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present stud... Objective: Unicameral bone cyst is a nonneoplasticbone lesion characterized by its tenacity and risk ofrecurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present study was to evaluate the results of hybrid external fixator for thetreatment of a unicameral bone cyst with a pathologicalfracture. Methods: Hybrid external fixator for thetreatment of a unicameral bone cyst was performed intwelve patients. These patients presented with a pathological fracture and were managed immediately with hybridexternal fixator, of whom four had been managedconservatively at other clinics before they were referred toour department. The cyst was located in the proximalhumerus in all patients. The mean age of the patients at the time of surgery was 8.7 years, and the mean duration offollow-up was 32.6 months. Radiographic evaluation wasperformed according to the criteria of Capanna et al., andthe cyst was classified as completely healed, healed withresidual radiolucency (osteolysis), recurred, or having noresponse. Results: The healing period ranged from three to eight months. Eight cysts healed completely, and threehealed with residual radiolucent areas visible onradiographs. There was recurrence of one cyst that hadhealed with residual radiolucency. All of the cysts in thepresent study responded to treatment. A modulation ofhybrid external fixator was necessary in three patients, asthe bars had become too short after bone growth or the pins had been loose. No major complications were observed.Conclusion: Hybrid external fixator provides earlystability, which allows early mobilization and thus obviates the need for a plaster cast. This method of treatment alsoallows for an early return to normal activity. 展开更多
关键词 Unicameral bone cyst external fixator Pathological fracture Bone graft
暂未订购
A BIOMECHANICAL ANALYSIS OF UNILATERAL HOOKED-SULCATED EXTERNAL FIXATOR ON OSTEOMINED TIBIA
14
作者 段德宇 刘国平 +1 位作者 杜靖远 饶振玉 《Chinese Medical Sciences Journal》 CAS CSCD 1998年第1期49-52,共4页
Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and th... Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and the bone-fixator system was used as a model of external fixation of tibial fracture. The axial compression, distraction, torsion, antero-posterior and lateral bending rigidly and the strain of the pins were determined in this system. Based on the results, we found that compared with the configuration of four paralled pins, the rigidity of the fan-like configuraton didn’t decrease significantly if the angle between lateral and medium pins was less than 45’. But the reverse was true when the frame separation increased from 5 to 8 cm. What’ more, the pin strain decreased if the rigidity of the system was improved. These data provided a theoretical basis of biomechanics for the improvement of UHSEF. 展开更多
关键词 TIBIA external fixator biomechanics)
暂未订购
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
15
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate Internal fixation Closed reduction external fixation PLASTER SPLINT Distal radius fracture Meta analysis
暂未订购
Biomechanical Study on Osteotomized Tibias Fixed with Unilateral Adjustable External Fixator
16
作者 刘国平 杜靖远 +2 位作者 王洪 陈汝轻 徐兆雄 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1995年第4期242-245,248,共5页
Five fresh tibias removed from 30-40 years old dead males were osteotomized at one-third supra-medium segment and then fixed by an unilateral adjustable external fixator (UAEF) to be used as a model of external fixati... Five fresh tibias removed from 30-40 years old dead males were osteotomized at one-third supra-medium segment and then fixed by an unilateral adjustable external fixator (UAEF) to be used as a model of external fixation of tibial fracture. For each loading test under different configurations of UAEF, the ratio of the force-displacement was used to determine its stiffness value. The weakest mode of the UAEF device is in AP bending. Under each mode of compression,distraction , anteroposterial and lateral bending and torsion loading , increasing the pin number or pin diameter or pin separation, and/or reduction of pin group separation can significantly increase the stiffness values of UAEF (P<0.01). These data revealed that UAEF is suitable for the external fixation of tibial fracture. 展开更多
关键词 TIBIA external fixator BIOMECHANICS
暂未订购
Dynamic External Fixator Combined with Volar Locking Plate Fixation for the Treatment of AO Type C3 Distal Radius Fractures
17
作者 Kinya Nishida Yong Ho Che +3 位作者 Hideto Irifune Kazuhiro Uesugi Akane Maeda Koji Miyata 《Open Journal of Orthopedics》 2022年第4期131-141,共11页
Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic... Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76&deg;and 64&deg;, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs. 展开更多
关键词 Distal Radius Fracture Intra-Articular Fracture external Fixator Dynamic external Fixator Volar Locking Plate
暂未订购
Stress Analysis of the Sarafix External Fixator Design
18
作者 Elmedin Megic Adil Muminovic Nedzad Repcic Mirsad Colic 《Journal of Mechanics Engineering and Automation》 2011年第6期473-480,共8页
A stress analysis of the Sarafix external fixator design was performed using finite element analysis (FEA) and experimental tensometric measurements. The study was conducted at one of the Sarafix fixator configurati... A stress analysis of the Sarafix external fixator design was performed using finite element analysis (FEA) and experimental tensometric measurements. The study was conducted at one of the Sarafix fixator configurations that have a clinical application in the treatment of tibia fractures. The intensity of principal and yon Mises stresses generated at two measuring points (MP) on the fixator connecting rod were monitored and analyzed during the testing on axial compression on the fixator design and its finite element model (FEM). The 3D geometrical and FEM model of the fixator was formed using the computer aided design/computer aided engineering (CAD/CAE) software system CATIA. Verification of the results for the dominant principal stresses obtained from FEA was carried out through tensometric measurements. The measuring chain consisted of strain gauges connected into two Wheatstone half-bridges, digital measuring amplifier system and a computer with software for acquisition and monitoring of measurement results. A quite good agreement was observed between the results obtained on the basis of FEA and results of experimental tensometric analysis, 展开更多
关键词 Finite element analysis tensometric measurements principal stresses von Mises stress Sarafix external fixator.
在线阅读 下载PDF
Curative Effect of Control Surgery with External Fixation for Traumatic Fracture
19
作者 LI Xujun 《外文科技期刊数据库(文摘版)医药卫生》 2021年第2期015-017,共3页
Objective: to investigate the curative effect of control surgery with external fixation for traumatic fracture. Methods: 90 patients with traumatic fracture admitted to our hospital from June 2019 to June 2020 were se... Objective: to investigate the curative effect of control surgery with external fixation for traumatic fracture. Methods: 90 patients with traumatic fracture admitted to our hospital from June 2019 to June 2020 were selected and randomization. 45 patients in the control group underwent open reduction and internal fixation, 45 patients in the observation group underwent control surgery with external fixation. Treatment outcomes were compared. Results: the incidence of complications, operative time and intraoperative blood loss in the observation group were significantly lower than those in the control group, and the comparison was statistically significant (P < 0.05). Conclusion: for patients with traumatic fracture, control surgery with external fixation has better effect, shorter operation time, less injury to the body, less incidence of postoperative complications and high safety, which is worthy of clinical promotion. 展开更多
关键词 control surgery with external fixation traumatic fracture curative effect COMPLICATION
暂未订购
Analysis of Clinical Application of External Fixator in the Treatment of Traumatic Orthopaedic Patients
20
作者 LIU Liang 《外文科技期刊数据库(文摘版)医药卫生》 2021年第10期498-500,共5页
Objective: to explore the clinical value of external fixator in traumatic orthopedic cases. Methods: 86 cases of traumatic orthopedic diseases treated in our hospital from April 2020 to April 2021 were randomly divide... Objective: to explore the clinical value of external fixator in traumatic orthopedic cases. Methods: 86 cases of traumatic orthopedic diseases treated in our hospital from April 2020 to April 2021 were randomly divided into 43 cases in the observation group and 43 cases in the control group. In terms of treatment methods, the control group was treated with internal fixation, while the observation group was treated with external fixation. The rehabilitation treatment effects of the two groups were compared. Results: through surgical treatment, in the comparison of various index data, the treatment effect of the observation group was more effective than that of the control group. Conclusion: for the treatment of traumatic orthopedic diseases, the technical treatment with external fixator can promote the significant improvement of fracture and reduce the incidence of complications, which is worthy of popularization in clinic. 展开更多
关键词 external fixator trauma orthopedics treatment effect
暂未订购
上一页 1 2 3 下一页 到第
使用帮助 返回顶部