期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Optical and electronic performances of CVD diamond film andits applications in radiation detectors 被引量:1
1
作者 张明龙 《Journal of Shanghai University(English Edition)》 CAS 2006年第6期561-562,共2页
The outstanding properties of CVD diamond film such as electronic, optical, thermal and mechanical and the high radiation hardness have made it an ideal candidate material for radiation detectors in severe environment... The outstanding properties of CVD diamond film such as electronic, optical, thermal and mechanical and the high radiation hardness have made it an ideal candidate material for radiation detectors in severe environments. Fabrication of 'detector grade' CVD diamond films and development of CVD diamond detectors have been leading edge subjects. Micro-strip gas chamber (MSGC) fabricated on CVD diamond substrate would overcome the charge-up effect and the substrate instability, which has been a hotspot in the research of gas detectors. 展开更多
关键词 CVD diamond film optical and electronic performances computer assistant multi-channel spectroscopy CVD diamond detector micro-strip gas chamber.
在线阅读 下载PDF
Impact of Arsenic Related Defects on Electronic Performance of ZrO2/GaAs:Density Functional Theory Calculations
2
作者 王宇鹏 王永萍 史力斌 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第1期104-107,共4页
Arsenic can diffuse into high-κ dielectrics during OaAs-based metal oxide semiconductor transistor process, which causes the degradation of gate dielectrics. To explore the origins of the degradation, we employ nonlo... Arsenic can diffuse into high-κ dielectrics during OaAs-based metal oxide semiconductor transistor process, which causes the degradation of gate dielectrics. To explore the origins of the degradation, we employ nonlocal B3LYP hybrid functional to study arsenic related defects in ZrO2. Via band alignments between the OaAs and ZrO2, we are able to determine the defect formation energy in the GaAs relative to the ZrO2 band gap and assess how they will affect the device performance. Arsenic at the interstitial site serves as a source of positive fixed charge while at the oxygen or zirconium substitutional site changes its charge state within the band gap of GaAs. Moreover, it is found that arsenic related defects produce conduction band offset reduction and gap states, which will increase the gate leakage current. 展开更多
关键词 Zr Impact of Arsenic Related Defects on electronic performance of ZrO2/GaAs:Density Functional Theory Calculations
原文传递
Electronic Performance Monitoring:A Literature Review and Research Prospect
3
作者 Ziyi Zhang 《Journal of Electronic Research and Application》 2025年第6期154-158,共5页
Amid the accelerating process of digital transformation,electronic performance monitoring has become an essential tool in organizational management.As a process that utilizes information technology to observe,record,a... Amid the accelerating process of digital transformation,electronic performance monitoring has become an essential tool in organizational management.As a process that utilizes information technology to observe,record,and analyze employees’work behaviors and performance,electronic performance monitoring not only enhances organizational efficiency and optimizes decision-making support but also exerts a profound influence on employees’psychological states and behavioral responses.This paper systematically reviews the conceptual evolution,measurement methods,and related research progress of electronic performance monitoring.The findings reveal that the definition of electronic performance monitoring has evolved dynamically from a“technological tool”to an“organizational practice,”and its measurement approaches have developed from a single-dimensional to a multi-dimensional perspective,encompassing aspects such as monitoring purpose,monitoring intensity,and monitoring feedback.Existing empirical studies indicate that different types of electronic performance monitoring,such as developmental and preventive monitoring,have distinct impacts on employees’job performance,innovative behavior,and psychological responses.Overall,developmental monitoring tends to foster positive behaviors and creativity,whereas preventive monitoring may trigger psychological resistance and counterproductive work behaviors.This review provides a theoretical foundation for understanding the dual-edged effects of electronic performance monitoring and lays the groundwork for developing localized measurement instruments and exploring its underlying mechanisms in future research. 展开更多
关键词 electronic performance monitoring performance feedback Employee response
在线阅读 下载PDF
Preface to Special Issue on Towards High Performance Ga_(2)O_(3) Electronics: Epitaxial Growth and Power Devices(Ⅰ)
4
作者 Genquan Han Shibing Long +2 位作者 Yuhao Zhang Yibo Wang Zhongming Wei 《Journal of Semiconductors》 EI CAS CSCD 2023年第6期4-6,共3页
There is currently great optimism within the electronics community that gallium oxide(Ga_(2)O_(3)) ultra-wide bandgap semiconductors have unprecedented prospects for eventually revolutionizing a rich variety of power ... There is currently great optimism within the electronics community that gallium oxide(Ga_(2)O_(3)) ultra-wide bandgap semiconductors have unprecedented prospects for eventually revolutionizing a rich variety of power electronic applications. Specially, benefiting from its ultra-high bandgap of around 4.8 eV, it is expected that the emerging Ga_(2)O_(3) technology would offer an exciting platform to deliver massively enhanced device performance for power electronics and even completely new applications. 展开更多
关键词 Epitaxial Growth and Power Devices Preface to Special Issue on Towards High performance Ga_(2)O_(3)electronics POWER
在线阅读 下载PDF
Bioinspired approaches for medical devices
5
作者 Zhi-Zhi Sheng Xiao Liu +6 位作者 Ling-Li Min Hong-Long Wang Wei Liu Miao Wang Li-Zhi Huang Feng Wu Xu Hou 《Chinese Chemical Letters》 SCIE CAS CSCD 2017年第6期1131-1134,共4页
Advances in medical devices have revolutionized the treatment of human diseases,such as stents in occluded coronary artery,left ventricular assist devices in heart failure,pacemakers in arrhythmias,etc.Despite their s... Advances in medical devices have revolutionized the treatment of human diseases,such as stents in occluded coronary artery,left ventricular assist devices in heart failure,pacemakers in arrhythmias,etc.Despite their significance,the development of devices for reducing and avoiding the thrombosis formation,obtaining excellent mechanical performance,and achieving stable electronic physiology remains challenging and unresolved.Fortunately,nature serves as a good resource of inspirations,and brings us endless bioinspired physicochemical ideas to better the development of novel artificial materials and devices that enable us to potentially overcome the unresolved obstacles.Bioinspired approaches,in particularly,owe much of their current development in biology,chemistry,materials science,medicine and engineering to the design and fabrication of advanced devices.The application of bioinspired devices is a burgeoning area in these fields of research.In this perspective,we would take the cardiovascular device as one example to show how these bioinspired approaches could be used to build novel,advanced biomedical devices with precisely controlled functions.Here,bioinspired approaches are utilized to solve issues like thrombogenic,mechanical and electronic physiology problems in medical devices.Moreover,there is an outlook for future challenges in the development of bioinspired medical devices. 展开更多
关键词 Bioinspired Medical devices Cardiac Thrombosis Mechanical performance electronic physiology
原文传递
Real-Time Dynamic Spectrum Analysis for Plasma Electron Density and Faraday Rotation Angle Measurement on HL-2A
6
作者 丁宝钢 吴军 +3 位作者 范伟伟 吴彤宇 周艳 阴泽杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第12期1092-1096,共5页
Electron density and Faraday rotation angle are important physical parameters in nuclear fusion research.To measure them simultaneously,the three-wave polarimeter/interferometer diagnostic system is applied.Both the f... Electron density and Faraday rotation angle are important physical parameters in nuclear fusion research.To measure them simultaneously,the three-wave polarimeter/interferometer diagnostic system is applied.Both the final probe output signal and the reference signal contain three frequency components.The time-varying phase difference curve of each frequency component can be measured by the Real-time Dynamic Spectrum Analysis(RDSA)method based on Field-Programmable Gate Array(FPGA).The phase difference precision is better than 0.1° and the real-time feedback delay is less than 1 ms,which satisfy the requirements of HL-2A. 展开更多
关键词 Electron Spectrum Faraday rotation interferometer satisfy performing Angle instead rotating
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部