基于实际工程,借助电磁暂态仿真软件EMTP-RV,建立了广西灵川县灵田风电场的详细仿真模型及与风电场接入同一变电站110 k V母线的灵川电铁牵引站及机车负荷模型。研究了风电场在不同风速出力和电铁负荷状态下公共接入点电能质量,以及风...基于实际工程,借助电磁暂态仿真软件EMTP-RV,建立了广西灵川县灵田风电场的详细仿真模型及与风电场接入同一变电站110 k V母线的灵川电铁牵引站及机车负荷模型。研究了风电场在不同风速出力和电铁负荷状态下公共接入点电能质量,以及风电场与电铁牵引负荷接入同一110 k V母线的相互影响。并开发了电能质量计算模板用于多种电能质量指标的计算。多种运行工况的仿真表明,风电场与电铁负荷接入同一母线会恶化电网的运行条件,导致公共接入点剧烈电压波动,并向公共电网注入大量谐波。针对仿真中揭示的电压波动与功率振荡现象,结合现场条件,针对性提出合理调度风电出力、谐波治理与无功补偿等多项改善措施,使接入点的电能质量满足国家标准。展开更多
One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order ...One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order to study the effects of VFTO extensively implemen- ted on EMTP-RV. In addition, the application of ferrite rings for suppressing VFTOs is assessed thoroughly. The main advantage of this paper is its new proposed algorithm according to the ferrite ring frequency dependent modeling that is validated with experimental results. This paper examines the effects of three compositions of the ferrite ring on VFTO suppression. Moreover, it estimates the dimension of the ferrite ring based on the SF6 gas insulation withstand and the maximum effect of ferrite rings on VFTO suppression constraint with the COMSOL multiphysics software. Furthermore, it gains VFTO attenuated percentages due to the installation of the ferrite ring in different GIS nodes. Finally, it analyzes the offered VFTO amendment technique in various GIS switching scenarios.展开更多
文摘基于实际工程,借助电磁暂态仿真软件EMTP-RV,建立了广西灵川县灵田风电场的详细仿真模型及与风电场接入同一变电站110 k V母线的灵川电铁牵引站及机车负荷模型。研究了风电场在不同风速出力和电铁负荷状态下公共接入点电能质量,以及风电场与电铁牵引负荷接入同一110 k V母线的相互影响。并开发了电能质量计算模板用于多种电能质量指标的计算。多种运行工况的仿真表明,风电场与电铁负荷接入同一母线会恶化电网的运行条件,导致公共接入点剧烈电压波动,并向公共电网注入大量谐波。针对仿真中揭示的电压波动与功率振荡现象,结合现场条件,针对性提出合理调度风电出力、谐波治理与无功补偿等多项改善措施,使接入点的电能质量满足国家标准。
文摘One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order to study the effects of VFTO extensively implemen- ted on EMTP-RV. In addition, the application of ferrite rings for suppressing VFTOs is assessed thoroughly. The main advantage of this paper is its new proposed algorithm according to the ferrite ring frequency dependent modeling that is validated with experimental results. This paper examines the effects of three compositions of the ferrite ring on VFTO suppression. Moreover, it estimates the dimension of the ferrite ring based on the SF6 gas insulation withstand and the maximum effect of ferrite rings on VFTO suppression constraint with the COMSOL multiphysics software. Furthermore, it gains VFTO attenuated percentages due to the installation of the ferrite ring in different GIS nodes. Finally, it analyzes the offered VFTO amendment technique in various GIS switching scenarios.