Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper ...Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.展开更多
The paper presents an adaptive controller formulated for a class of nonaffine discrete-time systems with non-strict forms and unknown dynamics.The controller operates based solely on the measured output,thus obviating...The paper presents an adaptive controller formulated for a class of nonaffine discrete-time systems with non-strict forms and unknown dynamics.The controller operates based solely on the measured output,thus obviating the need for knowledge of the physical order of the controlled plant.Utilizing an ideal solution and equivalent dynamics,the approach integrates an adaptive network with feedback and robust controllers to establish a closed-loop system.A learning law is derived under practical conditions of the designed parameters,ensuring effective closed-loop performance based on pure-output feedback.The controller’s effectiveness is validated through both numerical and experimental systems,with results meeting the conditions specified in the main theorem.Comparative analysis highlights the controller’s highly satisfactory performance and its advantages.This research offers a promising approach to adaptive control for discrete-time systems with non-strict dynamics,providing practical solutions for systems with unknown dynamics and indeterminate system order.展开更多
In deep drilling applications,such as those for geothermal energy,there are many challenges,such as those related to efficient operation of the drilling fluid(mud)pumping system.Legacy drilling rigs often use paired,p...In deep drilling applications,such as those for geothermal energy,there are many challenges,such as those related to efficient operation of the drilling fluid(mud)pumping system.Legacy drilling rigs often use paired,parallel-connected independent-excitation direct-current(DC)motors for mud pumps,that are supplied by a single power converter.This configuration results in electrical power imbalance,thus reducing its efficiency.This paper investigates this power imbalance issue in such legacy DC mud pump drive systems and offers an innovative solution in the form of a closed-loop control system for electrical load balancing.The paper first analyzes the drilling fluid circulation and electrical drive layout to develop an analytical model that can be used for electrical load balancing and related energy efficiency improvements.Based on this analysis,a feedback control system(so-called“current mirror”control system)is designed to balance the electrical load(i.e.,armature currents)of parallel-connected DC machines by adjusting the excitation current of one of the DC machines,thus mitigating the power imbalance of the electrical drive.Theproposed control systemeffectiveness has been validated,first through simulations,followed by experimental testing on a deep drilling rig during commissioning and field tests.The results demonstrate the practical viability of the proposed“current mirror”control system that can effectively and rather quickly equalize the armature currents of both DC machines in a parallel-connected electrical drive,and thus balance both the electrical and mechanical load of individual DC machines under realistic operating conditions of the mud pump electrical drive.展开更多
The ability of an energy storage system to improve the performance of a wind turbine(WT)with a fully rated converter was evaluated,where the energy storage device is embedded in the direct current(dc)link with a bidir...The ability of an energy storage system to improve the performance of a wind turbine(WT)with a fully rated converter was evaluated,where the energy storage device is embedded in the direct current(dc)link with a bidirectional dc/dc converter.Coordinated dc voltage control design of the line-side converter and the energy storage dc/dc converters was proposed using a common dc voltage measurement for smoothing the output power.A transfer function and Bode diagram were introduced to analyze the system performance with different control parameters.MATLAB/Simulink simulations are presented to demonstrate the effectiveness of the proposed methods.It was found that the proposed methods smooth the power output from the WT to the grid and thus improve the quality of the generated power.展开更多
基金supported by the key technology project of China Southern Power Grid Corporation(GZKJXM20220041)partly by theNational Key Research and Development Plan(2022YFE0205300).
文摘Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.
文摘The paper presents an adaptive controller formulated for a class of nonaffine discrete-time systems with non-strict forms and unknown dynamics.The controller operates based solely on the measured output,thus obviating the need for knowledge of the physical order of the controlled plant.Utilizing an ideal solution and equivalent dynamics,the approach integrates an adaptive network with feedback and robust controllers to establish a closed-loop system.A learning law is derived under practical conditions of the designed parameters,ensuring effective closed-loop performance based on pure-output feedback.The controller’s effectiveness is validated through both numerical and experimental systems,with results meeting the conditions specified in the main theorem.Comparative analysis highlights the controller’s highly satisfactory performance and its advantages.This research offers a promising approach to adaptive control for discrete-time systems with non-strict dynamics,providing practical solutions for systems with unknown dynamics and indeterminate system order.
文摘In deep drilling applications,such as those for geothermal energy,there are many challenges,such as those related to efficient operation of the drilling fluid(mud)pumping system.Legacy drilling rigs often use paired,parallel-connected independent-excitation direct-current(DC)motors for mud pumps,that are supplied by a single power converter.This configuration results in electrical power imbalance,thus reducing its efficiency.This paper investigates this power imbalance issue in such legacy DC mud pump drive systems and offers an innovative solution in the form of a closed-loop control system for electrical load balancing.The paper first analyzes the drilling fluid circulation and electrical drive layout to develop an analytical model that can be used for electrical load balancing and related energy efficiency improvements.Based on this analysis,a feedback control system(so-called“current mirror”control system)is designed to balance the electrical load(i.e.,armature currents)of parallel-connected DC machines by adjusting the excitation current of one of the DC machines,thus mitigating the power imbalance of the electrical drive.Theproposed control systemeffectiveness has been validated,first through simulations,followed by experimental testing on a deep drilling rig during commissioning and field tests.The results demonstrate the practical viability of the proposed“current mirror”control system that can effectively and rather quickly equalize the armature currents of both DC machines in a parallel-connected electrical drive,and thus balance both the electrical and mechanical load of individual DC machines under realistic operating conditions of the mud pump electrical drive.
文摘The ability of an energy storage system to improve the performance of a wind turbine(WT)with a fully rated converter was evaluated,where the energy storage device is embedded in the direct current(dc)link with a bidirectional dc/dc converter.Coordinated dc voltage control design of the line-side converter and the energy storage dc/dc converters was proposed using a common dc voltage measurement for smoothing the output power.A transfer function and Bode diagram were introduced to analyze the system performance with different control parameters.MATLAB/Simulink simulations are presented to demonstrate the effectiveness of the proposed methods.It was found that the proposed methods smooth the power output from the WT to the grid and thus improve the quality of the generated power.