期刊文献+
共找到458篇文章
< 1 2 23 >
每页显示 20 50 100
Preliminary Design of Control Network for HT-7U Tokamak Cryogenic System 被引量:2
1
作者 金毅彬 庄明 白宏宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第6期2035-2038,共4页
In the course of the cryoplant modernization, a control network will be set up in order to facilitate the control, the supervision, the centralized data acquisition and the alarm handling of the cryogenic system for H... In the course of the cryoplant modernization, a control network will be set up in order to facilitate the control, the supervision, the centralized data acquisition and the alarm handling of the cryogenic system for HT-7U tokamak. The paper introduces the preliminary design of control network based on the Controller Link Network for HT-7U tokamak cryogenic system. The multi-layer structure mentioned in the paper is the mainstream of automatic control. The control philosophy, the structure of the network and the components for control are also presented. 展开更多
关键词 HT-7U cryogenic system control network
在线阅读 下载PDF
Optimization Analysis and Simulation of the EAST Cryogenic System 被引量:1
2
作者 邱立龙 庄明 +2 位作者 毛晋 胡良兵 盛林海 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第11期1030-1034,共5页
This paper presents the optimization cycle of the EAST cryogenic system. A simulation analysis and simulation of the main Claude program of this cycle was developed on the basis of the characteristics of the component... This paper presents the optimization cycle of the EAST cryogenic system. A simulation analysis and simulation of the main Claude program of this cycle was developed on the basis of the characteristics of the components and verified with the experimental results. The built-in volume ratio of the No. 7 compressor was tested with the purpose of finding the optimum internal pressure ratio to comply with the external pressure ratio so as to increase the isothermal efficiency and cycle efficiency. In addition, the UA (U, heat transfer coefficient; A, heat transfer area) values of the heat exchangers, efficiencies of turbines, mass flow fraction of the turbine stream were analyzed in order to improve the capacity or efficiency of the cycle. Finally, in view of the estimated heat loads of EAST in future, an upgraded operational cycle of 1500 W/4.5 K +1000 W/3.5 K +5 g/s is proposed according to the simulation. 展开更多
关键词 claude cycle helium refrigerator cryogenic system EAST
在线阅读 下载PDF
Present status and one upgrading method with a cold compressor of the EAST sub-cooling helium cryogenic system 被引量:3
3
作者 朱志刚 张启勇 +4 位作者 宋云涛 庄明 周芷伟 成安义 朱平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第5期102-108,共7页
Since 2006, the superconducting toroidal field(TF) coils of the Experimental Advanced Superconducting Tokomak(EAST) have been successfully cooled by supercritical helium at a temperature of 4.5 K and a pressure of... Since 2006, the superconducting toroidal field(TF) coils of the Experimental Advanced Superconducting Tokomak(EAST) have been successfully cooled by supercritical helium at a temperature of 4.5 K and a pressure of 4 bara in eleven experiments. To obtain higher operating currents and magnetic fields it is necessary to lower the operating temperature of the TF coils.The EAST sub-cooling helium cryogenic system, with a warm oil ring pump(ORP), was tested twice in cool-down experiments, which made the TF coils operate at 3.8 K. However, the long term operational stability of the sub-cooling system cannot be guaranteed because of the ORP's poor mechanical and control performance. In this paper, the present status of the EAST subcooling helium cryogenic system is described, and then several cooling methods below 4.2 K and their merits are presented and analyzed. Finally, an upgrading method with a cold compressor for an EAST sub-cooling helium cryogenic system is proposed. The new process flow and thermodynamic calculation of the sub-cooling helium system, and the main parameters of the cold compressor, are also presented in detail. This work will provide a reference for the future upgrading of the sub-cooling helium system for higher operation parameters of the EAST device. 展开更多
关键词 EAST cryogenic system helium refrigerator sub-cooling helium cold compressor
在线阅读 下载PDF
The Application and Improvement of Helium Turbines in the EAST Cryogenic System
4
作者 付豹 张启勇 +1 位作者 朱平 成安义 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第5期527-531,共5页
The helium cryogenic system supplies supercritical helium cooling capacity at 4.5 K for the superconducting magnets in the EAST superconducting tokamak.Four low-temperature helium turbines are used in the 2 kW helium ... The helium cryogenic system supplies supercritical helium cooling capacity at 4.5 K for the superconducting magnets in the EAST superconducting tokamak.Four low-temperature helium turbines are used in the 2 kW helium refrigeration system,and their performance and reliability are critical for the continuous operation of the tokamak.The turbines were made by the Helium Mechanics Company in Russia.The start-up process is very unstable,easily broken,and thus testing and improvements are needed.In this paper,we analyze the structure of the helium turbine,make improvements,and describe the testing process and results of the improved helium turbines.Some of the operational experiences during the start-up process and tests are also presented. 展开更多
关键词 helium turbines helium refrigerator helium cryogenic system EAST tokamak
在线阅读 下载PDF
Optimal design of the first stage of the platefin heat exchanger for the EAST cryogenic system
5
作者 蒋庆峰 朱志刚 +2 位作者 张启勇 庄明 陆小飞 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第3期163-171,共9页
The size of the heat exchanger is an important factor determining the dimensions of the cold box in helium cryogenic systems. In this paper, a counter-flow multi-stream plate-fin heat exchanger is optimized by means o... The size of the heat exchanger is an important factor determining the dimensions of the cold box in helium cryogenic systems. In this paper, a counter-flow multi-stream plate-fin heat exchanger is optimized by means of a spatial interpolation method coupled with a hybrid genetic algorithm.Compared with empirical correlations, this spatial interpolation algorithm based on a kriging model can be adopted to more precisely predict the Colburn heat transfer factors and Fanning friction factors of offset-strip fins. Moreover, strict computational fluid dynamics simulations can be carried out to predict the heat transfer and friction performance in the absence of reliable experimental data. Within the constraints of heat exchange requirements, maximum allowable pressure drop, existing manufacturing techniques and structural strength, a mathematical model of an optimized design with discrete and continuous variables based on a hybrid genetic algorithm is established in order to minimize the volume. The results show that for the first-stage heat exchanger in the EAST refrigerator, the structural size could be decreased from the original2.200?×?0.600?×?0.627(m^3) to the optimized 1.854?×?0.420?×?0.340(m3), with a large reduction in volume. The current work demonstrates that the proposed method could be a useful tool to achieve optimization in an actual engineering project during the practical design process. 展开更多
关键词 EAST cryogenic system plate-fin heat exchanger OPTIMIZATION genetic algorithm
在线阅读 下载PDF
ADS Injector-I 2 K superfluid helium cryogenic system 被引量:8
6
作者 Rui Ge Shao-Peng Li +14 位作者 Rui-Xiong Han Miao-Fu Xu Liang-Rui Sun Min-Jing Sang Rui Ye Zhuo Zhang Jie-Hao Zhang Xiang-Zhen Zhang Lin Bian Jian-Qin Zhang Mei Li Chang-Cheng Ma Zheng-Ze Chang Tong-Xian Zhao Yong-Cheng Jiang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第4期79-92,共14页
The Accelerator Driven Sub-critical(ADS)system is a strategic plan to solve the nuclear waste problem for nuclear power plants in China.High-energy particle accelerators and colliders contain long strings of supercond... The Accelerator Driven Sub-critical(ADS)system is a strategic plan to solve the nuclear waste problem for nuclear power plants in China.High-energy particle accelerators and colliders contain long strings of superconducting devices,superconducting radio frequency cavities,and magnets,which may require cooling by 2 K superfluid helium(HeliumⅡ).2 K superfluid helium cryogenic system has become a research hot spot in the field of superconducting accelerators.In this study,the ADS Injector-I 2 K cryogenic system is examined in detail.The cryogenic system scheme design,key equipment,and technology design,such as the 2 K Joule–Thomson(J–T)heat exchanger and cryomodules CM1+CM2 design,are examined,in addition to the commissioning and operation of the cryogenic system.The ADS Injector-I 2 K cryogenic system is the first 100 W superfluid helium system designed and built independently in China.The ADS proton beam reached 10 Me V at 10 m A in July 2016 and 10 Me V at 2 m A in continuous mode in January 2017 and has been operated reliably for over 15,000 h,proving that the design of ADS Injector-I 2 K cryogenic system,the key equipment,and technology research are reasonable,reliable,and meet the requirements.The research into key technologies provides valuable engineering experience that can be helpful for future projects such as CI-ADS(China Initiative Accelerator-Driven System),SHINE(Shanghai High Repetition Rate XFEL and Extreme Light Facility),PAPS(Platform of Advanced Photon Source Technology),and CEPC(Circular Electron-Positron Collider),thereby developing national expertise in the field of superfluid helium cryogenic systems. 展开更多
关键词 ADS SUPERFLUID HELIUM cryogenic system Cryomodule J–T heat EXCHANGER
在线阅读 下载PDF
Cryogenic system design for HIAF iLinac 被引量:2
7
作者 Xiao-Fei Niu Feng Bai +3 位作者 Xian-Jin Wang Jun-Hui Zhang Xiao-Hong Guo Da-Ming Sun 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第12期48-57,共10页
A helium cryogenic system is designed by the Institute of Modern Physics,Chinese Academy of Sciences,to supply different cooling powers to the cryomodules of ion-Linac(iLinac)accelerator,which serves as the injector o... A helium cryogenic system is designed by the Institute of Modern Physics,Chinese Academy of Sciences,to supply different cooling powers to the cryomodules of ion-Linac(iLinac)accelerator,which serves as the injector of the High Intensity Heavy-Ion Accelerator Facility project.The iLinac is a superconducting heavy-ion accelerator approximately 100 m long and contains 13 cryomodules cooled by superfluid helium.This article describes the cryogenic system design of the iLinac accelerator.The requirements of the cryogenic system,such as cooling mode,refrigeration temperature,operating pressure and pressure stability,are introduced and described in detail.In addition,heat loads from different sources are analyzed and calculated quantitatively.An equivalent cooling capacity of 10 kW at 4.5 K was determined for the cryogenic system according to the total heat load.Furthermore,a system process design was conducted and analyzed in detail.Further,the system layout and the main equipment are presented. 展开更多
关键词 Ion-Linac(iLinac)accelerator SUPERFLUID liquid HELIUM cryogenic system Cryomodule
在线阅读 下载PDF
Cryogenic System for PKU-FEL
8
作者 Lianyou Xiong Nan Peng +8 位作者 Wenhai Lu Liqiang Liu Xiaojun Liu Jing Li Liya Ma Bing Dong Yongcheng Jiang Jiancheng Tang Liang Zhang 《Journal of Modern Physics》 2013年第6期1-4,共4页
PKU-FEL based on superconducting (SC) accelerator facility is under construction at PekingUniversity. It will run in IR (5 - 10 μm) and THz (100 - 3000 μm) region as an ideal experimental FEL platform for universiti... PKU-FEL based on superconducting (SC) accelerator facility is under construction at PekingUniversity. It will run in IR (5 - 10 μm) and THz (100 - 3000 μm) region as an ideal experimental FEL platform for universities. The SC accelerator facility is composed of a DC-SC injector and a 1.3-GHz 2 × 9-cell SC accelerator. In order to better the performance, the injector and the accelerator are bath-cooled by 2 K super fluid helium in cryostats. A 2 K cryogenic system has been designed, constructed and assembled. 展开更多
关键词 Free ELECTRON LASER SUPERCONDUCTING ACCELERATOR cryogenic system
在线阅读 下载PDF
6-31 Progress of Cryogenic System in 2014
9
作者 Zhang Junhui Guo Xiaohong +15 位作者 Jin Tao Zhao Yugang Niu Xiaofei Wan Yuqin Su Hailin Han Yanning Yang Yonghui Bai Feng Jiang Ziyun Hu Chuanfei Zhang Peng Guo Wanhong Yin Yukui Liu Zuohui Hu Yongping Wang Xianjin 《IMP & HIRFL Annual Report》 2014年第1期285-285,共1页
During the year of 2014, the work of cryogenic group was mainly focused on operation of refrigerator system,test of TCM1, design and machining of HCM6. At the end of 2014 refrigerator system has achieved closed-loopop... During the year of 2014, the work of cryogenic group was mainly focused on operation of refrigerator system,test of TCM1, design and machining of HCM6. At the end of 2014 refrigerator system has achieved closed-loopoperation and recycle of helium gas, which did great contribution to superconducting cavity and superconductingmagnet test. Since the refrigerator was put into use(Fig. 1), it has operated continuously and reliably for more than5 110 h, reached helium lique ed capacity 270 L/h at 850 W. 展开更多
关键词 PROGRESS cryogenic system
在线阅读 下载PDF
6-22 Cryogenic System at IMP in 2015
10
作者 Zhang Junhui Guo Xiaohong 《IMP & HIRFL Annual Report》 2015年第1期293-294,共2页
In 2015, the work of cryogenic group mainly focused on HCM6 and the operation of cryogenic system in ADS injector Ⅱ.Last year we completed the design, assembling and running of HCM6-1. And it has been running 2 376 h... In 2015, the work of cryogenic group mainly focused on HCM6 and the operation of cryogenic system in ADS injector Ⅱ.Last year we completed the design, assembling and running of HCM6-1. And it has been running 2 376 h stably. ADS injector II got proton beam with 11 mA@CW for 1 h. Fig. 1 shows the Assembling of HCM6-1. The temperature, pressure, helium level can be read and written in HCM6-1. 展开更多
关键词 cryogenic system IMP
在线阅读 下载PDF
Recent Activities of Cryogenic System in Overseas and Domestic Accelerators 被引量:2
11
作者 李少鹏 葛锐 王国平 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第z1期194-196,共3页
The superconducting RF cavity and superconducting magnet are the key devices in modern accelerators. With the development of accelerator technology and requirement of higher beam energy and luminosity,the cryogenic an... The superconducting RF cavity and superconducting magnet are the key devices in modern accelerators. With the development of accelerator technology and requirement of higher beam energy and luminosity,the cryogenic and superconducting technologies are applied widely in the accelerator construction.Based on the study of several typical accelerators which adopted cryogenic and superconducting technology,this paper introduces the recent activities of cryogenic system in overseas and domestic accelerators. 展开更多
关键词 CERN DESY KEK BNL cryogenic system superconducting RF cavity superconducting magnet
原文传递
Quantitative analysis on T1 phase precipitation behaviors and mechanicalproperties of 2195 Al−Li alloy after cryogenic deformation and aging
12
作者 Meng-jia YAO Hua-bo ZHOU +1 位作者 Rui-qian WANG Wei LIU 《Transactions of Nonferrous Metals Society of China》 2026年第1期25-42,共18页
The water-quenched(WQ)2195 Al−Li alloy was subjected to stretching at different temperatures,from room temperature(RT)to−196℃(CT),to investigate the effect of cryogenic deformation on the aging precipitation behavior... The water-quenched(WQ)2195 Al−Li alloy was subjected to stretching at different temperatures,from room temperature(RT)to−196℃(CT),to investigate the effect of cryogenic deformation on the aging precipitation behaviors and mechanical properties.The precipitation kinetics of the T1 phase and the microstructures in peak aging state were investigated through the differential scanning calorimetric(DSC)tests and electron microscopy observation.The results show that−196℃deformation produces a high dislocation density,which promotes the precipitation of the T1 phase and refines its sizes significantly.In addition,the grain boundary precipitates(GBPs)of−196℃-stretched samples are suppressed considerably due to the high dislocation density in the grain interiors,which increases the ductility.In comparison,the strength remains nearly constant.Thus,it is indicated that cryogenic forming has the potential to provide the shape and property control for the manufacture of critical components of aluminum alloys. 展开更多
关键词 Al−Li alloy cryogenic stretching T1 phase precipitation kinetics grain boundary precipitates
在线阅读 下载PDF
EAST Cryogenic Supervisory and Control System Based on Delta-V DCS 被引量:7
13
作者 金毅彬 邵新安 +1 位作者 庄明 白红宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第5期3013-3016,共4页
The control system for the Experimental Advanced Superconductive Tokamak (EAST) cryogenic system is designed and constructed based on Delta-V DCS (Distribution Control System), which consists of engineering workst... The control system for the Experimental Advanced Superconductive Tokamak (EAST) cryogenic system is designed and constructed based on Delta-V DCS (Distribution Control System), which consists of engineering workstations, operator workstations, application workstations, redundant controller units, input/output (I/O) cards and a redundant control network. Our task is to design a supervisory and control system to provide the operator interface for control and monitoring, sending alarms, archiving of selected signals, and other routines to analyze realtime and historic data. The hardware configuration, software structure and control algorithms are illustrated in detail in this paper. Hvpothetic oroblems and further research are also mentioned. 展开更多
关键词 cryogenic system experimental advanced superconductive tokamak (EAST) Delta-V DCS supervisory control
在线阅读 下载PDF
Numerical analysis of the static performance of an annular aerostatic gas thrust bearing applied in the cryogenic turbo-expander of the EAST subsystem 被引量:1
14
作者 Tianwei LAI Bao FU +2 位作者 Shuangtao CHEN Qiyong ZHANG Yu HOU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第2期115-122,共8页
The EAST superconducting tokamak, an advanced steady-state plasma physics experimental device, has been built at the Institute of Plasma Physics, Chinese Academy of Sciences. All the toroidal field magnets and poloida... The EAST superconducting tokamak, an advanced steady-state plasma physics experimental device, has been built at the Institute of Plasma Physics, Chinese Academy of Sciences. All the toroidal field magnets and poloidal field magnets, made of NbTi/Cu cable-in-conduit conductor, are cooled with forced flow supercritical helium at 3.8 K. The cryogenic system of EAST consists of a 2 kW/4 K helium refrigerator and a helium distribution system for the cooling of coils, structures, thermal shields, bus-lines, etc. The high-speed turbo-expander is an important refrigerating component of the EAST cryogenic system. In the turbo-expander, the axial supporting technology is critical for the smooth operation of the rotor bearing system. In this paper, hydrostatic thrust bearings are designed based on the axial load of the turbo-expander. Thereafter, a computational fluid dynamics-based numerical model of the aerostatic thrust bearing is set up to evaluate the bearing performance. Tilting effect on the pressure distribution and bearing load is analyzed for the thrust beating. Bearing load and stiffness are compared with different static supply pressures. The net force from the thrust bearings can be calculated for different combinations of bearing clearance and supply pressure. 展开更多
关键词 EAST helium cryogenic system aerostatic thrust beating INCLINATION bearing load
在线阅读 下载PDF
Study on cooling process of cryogenic system for superconducting magnets of BEPCⅡ
15
作者 宗占国 刘立强 +5 位作者 熊联友 李少鹏 徐庆金 何昆 张亮 高杰 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第9期761-765,共5页
In the upgrade project of the Beijing Electron Positron Collider (BEPC Ⅱ ), three superconducting magnets are employed to realize the goal of two orders of magnitude higher luminosity. A cryogenic system with a tot... In the upgrade project of the Beijing Electron Positron Collider (BEPC Ⅱ ), three superconducting magnets are employed to realize the goal of two orders of magnitude higher luminosity. A cryogenic system with a total capacity of 0.5 kW at 4.5 K was built at the Institute of High Energy Physics (IHEP) to support the operations of these superconducting devices. For preparing the commissioning of the system, the refrigeration process was simulated and analyzed numerically. The numerical model was based on the latest engineering progress and focused on the normal operation mode. The pressure and temperature profiles of the cryogenic system are achieved with the simulation. The influence of the helium mass flow rates to cool superconducting magnets on the thermodynamic parameters of their normal operation is also studied and discussed in this paper. 展开更多
关键词 BEPC superconducting magnets cryogenic system
原文传递
Transient thermal analysis model of nitrogen-cooled cryogenic system for superconducting electromagnetic suspension magnet
16
作者 Wang Lei Wang Luoyuan Xing Mingtian 《Advances in Engineering Innovation》 2024年第4期17-23,共7页
This paper proposes a transient thermal analysis model for a nitrogen-cooled cryogenic system used in superconducting electromagnetic suspension magnets.First,the structural parameters of the nitrogen cryogenic system... This paper proposes a transient thermal analysis model for a nitrogen-cooled cryogenic system used in superconducting electromagnetic suspension magnets.First,the structural parameters of the nitrogen cryogenic system and the internal hightemperature superconducting magnet are detailed.Subsequently,temperature change simulations during the system's cooling process using a cryocooler,as well as during the cooling and nitrogen-insulation process,were conducted using COMSOL software.Finally,simulations of the temperature variations during the system's offline operation were performed.This study provides valuable references for the design and optimization of nitrogen-cooled cryogenic systems. 展开更多
关键词 nitrogen-cooled cryogenic system superconducting electromagnetic suspension magnets transient thermal analysis
在线阅读 下载PDF
A New Method for Determining Fluid Compositions in the H_2O-NaClCaCl_2 System with Cryogenic Raman Spectroscopy 被引量:8
17
作者 CHI Guoxiang CHU Haixia +1 位作者 Ryan SCOTT CHOU I-Ming 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第4期1169-1182,共14页
Raman peaks of various hydrates in the H20-NaCl-CaCl2 system have been previously identified, but a quantitative relationship between the Raman peaks and XNaCl (i.e.,NaCl/ (NaCl+CaCl2)) has not been established, ... Raman peaks of various hydrates in the H20-NaCl-CaCl2 system have been previously identified, but a quantitative relationship between the Raman peaks and XNaCl (i.e.,NaCl/ (NaCl+CaCl2)) has not been established, mainly due to the difficulty to freeze the solutions. This problem was solved by adding alumina powder to the solutions to facilitate nucleation of crystals. Cryogenic (-185℃) Raman spectroscopic studies of alumina-spiced solutions indicate that XNaCl is linearly correlated with the total peak area fraction of hydrohalite. Capsules of solutions made from silica capillary were prepared to simulate fluid inclusions. Most of these artificial fluid inclusions could not be totally frozen even at temperatures as low as -185℃, and the total peak area fraction of hydrohalite is not correlated linearly with XNaCI. However, the degree of deviation (△XNaCl) from the linear correlation established earlier is related to the amount of residual solution, which is reflected by the ratio (r) of the baseline "bump" area, resulting from the interstitial unfrozen brine near 3435 cm^-1, and the total hydrate peak area between 3350 and 3600 cm^-1. A linear correlation between △XNaCl and r is established to estimate XNaCl from cryogenic Raman spectroscopic analysis for fluid inclusions. 展开更多
关键词 cryogenic RAMAN H20-NaCl-CaCl2 XNaCI fluid inclusion
在线阅读 下载PDF
Determining Fluid Compositions in the H_2O-NaCl-CaCl_2 System with Cryogenic Raman Spectroscopy:Application to Natural Fluid Inclusions 被引量:2
18
作者 CHU Haixia CHI Guoxiang 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2015年第3期894-901,共8页
Previous cryogenic Raman spectroscopic analysis of H_2O-NaCl-CaCl_2 solutions has identified the Raman peaks of various hydrates of NaCl and CaCl_2,and established a linear relationship between Raman band intensity of... Previous cryogenic Raman spectroscopic analysis of H_2O-NaCl-CaCl_2 solutions has identified the Raman peaks of various hydrates of NaCl and CaCl_2,and established a linear relationship between Raman band intensity of the hydrates and the composition of the solution(NaCl/(NaCl+CaCl_2) molar ratio,or X_(NaC1)) using synthetic fluids,which created the opportunity to quantitatively determine the solute composition of aqueous fluid inclusions with cryogenic Raman spectroscopy.This paper aims to test the feasibility of this newly established method with natural fluid inclusions.Twenty-five fluid inclusions in quartz from various occurrences which show a high degree of freezing during the cooling processes were carefully chosen for cryogenic Raman analysis.X_(Na)Cl was calculated using their spectra and an equation established in a previous study.These inclusions were then analyzed with the thermal decrepitation-SEM-EDS method.The X_(NaCl) values estimated from the two methods show a 1:1 correlation,indicating that the new,non-destructive cryogenic Raman spectroscopic analysis method can indeed be used for fluid inclusion compositional study. 展开更多
关键词 cryogenic Raman XNaCI fluid inclusion H2O-NaCl-CaCl2
在线阅读 下载PDF
Design and Implementation of Quench Protection in the EAST Cryogenic Control System 被引量:2
19
作者 周芷伟 白红宇 +2 位作者 庄明 胡良兵 夏根海 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第3期347-351,共5页
An outline of the complete design of the cryogenic system, including the detection of quench signals, the processing flow after a quench and the concrete measures of pressure release for EAST is described in this pape... An outline of the complete design of the cryogenic system, including the detection of quench signals, the processing flow after a quench and the concrete measures of pressure release for EAST is described in this paper. The hardware and software configurations on DeltaV DCS are illustrated in detail. The results of quench protection testing in cooling experiments are also analyzed. 展开更多
关键词 cryogenic control system EAST superconducting tokamak quench protec-tion safety interlock DeltaV DCS
在线阅读 下载PDF
Control System Design and Test for Cryogenic Ground Support Equipment 被引量:1
20
作者 杨煜普 李祥宝 +2 位作者 季睿 宫亮 SCHINZEL Dietrich 《Journal of Shanghai Jiaotong university(Science)》 EI 2011年第5期543-550,共8页
The cryogenic ground support equipment (CGSE) is an important part of Alpha Magnetic Spectrometer-02 (AMS-02) experiment which is a particle physics experiment. CGSE is used to cool down the superconducting magnet of ... The cryogenic ground support equipment (CGSE) is an important part of Alpha Magnetic Spectrometer-02 (AMS-02) experiment which is a particle physics experiment. CGSE is used to cool down the superconducting magnet of AMS-02 to its operating temperature of 1.8K and to fill the magnet helium tank with superfluid helium. This paper introduces the control system of CGSE and presents the performance of the system. 展开更多
关键词 superconducting magnet cryogenic control system Alpha Magnetic Spectrometer-02 experiment
原文传递
上一页 1 2 23 下一页 到第
使用帮助 返回顶部