This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250...This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250–498 nm spectral range are investigated by measuring laser-induced micro plasma near a Ti plate and used to calculate the relative spectral response of an entire LIBS detection system. The results are compared with those of the conventional relative spectral response calibration method using a tungsten halogen lamp, and certain lines available for the BR method are selected. The study supports the common manner of using BRs to calibrate the detection system in LIBS setups.展开更多
The main payload on CBERS-01/02 of China-Brazil Earth Resources Satellite(CBERS)is a push-broom CCD camera with moderate spatial and radiant resolution.Because at lab the data for calibration at satellite assembly sta...The main payload on CBERS-01/02 of China-Brazil Earth Resources Satellite(CBERS)is a push-broom CCD camera with moderate spatial and radiant resolution.Because at lab the data for calibration at satellite assembly stage were unable to be collected,and also because the onboard calibrator after launch was in a different state from imaging,the calibration of CCD image got a series of difficulties involved.In practice,two methods are used in the processing on the ground station:One is extracting calibration data by statistics from the image itself,and the other is the method of histogram match.It was proved that the latter can calibrate the image much better,because it can remove the effect of unstable response of the camera largely and also can overcome the nonlinearity of the camera basically by using Look-Up Table(LUT)calculated from histogram statistics of different temporal images.Considering the problems of CBERS-01,a lot of calibration tests were done before the launch of CBERS-02,in which a set of lab coefficients for relative calibration was formulated after the data collection by using integration-hemisphere in the stage of satellite assembly test.During the on-orbit test,it was found that the calibration result from such coefficients was not satisfying,especially there being response difference between 3 detector arrays,which was attributed to the unstable dark currents of the CCD camera.This paper comes up with a statistic method to remove such response difference.In this method the middle detector array was used as reference to find the response differences of adjacent similar features between these arrays and it was proved to have a broad adaptability.展开更多
基金supported by the National Key Scientific Instrument and Equipment Development Projects of China (2014YQ120351)National Natural Science Foundation of China (11704372)Anhui Provincial Natural Science Foundation (1708085QF130)
文摘This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250–498 nm spectral range are investigated by measuring laser-induced micro plasma near a Ti plate and used to calculate the relative spectral response of an entire LIBS detection system. The results are compared with those of the conventional relative spectral response calibration method using a tungsten halogen lamp, and certain lines available for the BR method are selected. The study supports the common manner of using BRs to calibrate the detection system in LIBS setups.
基金supported by a program from Commission of Science Technology and Industry for National Defense(Grant No.[2001]891).
文摘The main payload on CBERS-01/02 of China-Brazil Earth Resources Satellite(CBERS)is a push-broom CCD camera with moderate spatial and radiant resolution.Because at lab the data for calibration at satellite assembly stage were unable to be collected,and also because the onboard calibrator after launch was in a different state from imaging,the calibration of CCD image got a series of difficulties involved.In practice,two methods are used in the processing on the ground station:One is extracting calibration data by statistics from the image itself,and the other is the method of histogram match.It was proved that the latter can calibrate the image much better,because it can remove the effect of unstable response of the camera largely and also can overcome the nonlinearity of the camera basically by using Look-Up Table(LUT)calculated from histogram statistics of different temporal images.Considering the problems of CBERS-01,a lot of calibration tests were done before the launch of CBERS-02,in which a set of lab coefficients for relative calibration was formulated after the data collection by using integration-hemisphere in the stage of satellite assembly test.During the on-orbit test,it was found that the calibration result from such coefficients was not satisfying,especially there being response difference between 3 detector arrays,which was attributed to the unstable dark currents of the CCD camera.This paper comes up with a statistic method to remove such response difference.In this method the middle detector array was used as reference to find the response differences of adjacent similar features between these arrays and it was proved to have a broad adaptability.