期刊文献+
共找到1,326篇文章
< 1 2 67 >
每页显示 20 50 100
Additional considerations on a combination of inflammatory markers and scoring systems for early severity stratification of acute pancreatitis
1
作者 Chen-Huan Wang Ya-Qi Zhai 《World Journal of Gastroenterology》 2025年第25期128-130,共3页
A recent single-center retrospective study proposed novel combinations of hematological parameters and scoring systems for predicting severe acute pancre-atitis.While these combinations showed promising predictive per... A recent single-center retrospective study proposed novel combinations of hematological parameters and scoring systems for predicting severe acute pancre-atitis.While these combinations showed promising predictive performance,several limitations warrant consideration,including the lack of calibration,the absence of key inflammatory markers such as procalcitonin,and practical challenges in integrating these models into routine clinical workflows.To improve predictive accuracy and clinical applicability,prospective validation and the inclusion of additional variables are recommended. 展开更多
关键词 Acute pancreatitis PROCALCITONIN CALIBRATION Severity stratification Prognostic model
暂未订购
Field system-level calibration method for accelerometer considering nonlinear coefficients
2
作者 WU Haotian YU Ruihang +2 位作者 CAO Juliang MA Caixia YANG Bainan 《Journal of Systems Engineering and Electronics》 2025年第3期814-824,共11页
In order to get rid of the dependence on high-precision centrifuges in accelerometer nonlinear coefficients calibration,this paper proposes a system-level calibration method for field condition.Firstly,a 42-dimension ... In order to get rid of the dependence on high-precision centrifuges in accelerometer nonlinear coefficients calibration,this paper proposes a system-level calibration method for field condition.Firstly,a 42-dimension Kalman filter is constructed to reduce impact brought by turntable.Then,a biaxial rotation path is designed based on the accelerometer output model,including orthogonal 22 positions and tilt 12 positions,which enhances gravity excitation on nonlinear coefficients of accelerometer.Finally,sampling is carried out for calibration and further experiments.The results of static inertial navigation experiments lasting 4000 s show that compared with the traditional method,the proposed method reduces the position error by about 390 m. 展开更多
关键词 ACCELEROMETER nonlinear coefficient system-level calibration rotation path
在线阅读 下载PDF
Automatic Digital Inclinometer Calibration System Based on Image Recognition
3
作者 FENG Zheming CHEN Gang +1 位作者 NAN Zhuojiang TAO Wei 《Journal of Shanghai Jiaotong university(Science)》 2025年第2期280-290,共11页
Traditional calibration method for the digital inclinometer relies on manual inspection,and results in its disadvantages of complicated process,low-efficiency and human errors easy to be introduced.To improve both the... Traditional calibration method for the digital inclinometer relies on manual inspection,and results in its disadvantages of complicated process,low-efficiency and human errors easy to be introduced.To improve both the calibration accuracy and efficiency of digital inclinometer,an automatic digital inclinometer calibration system was developed in this study,and a new display tube recognition algorithm was proposed.First,a high-precision automatic turntable was taken as the reference to calculate the indication error of the inclinometer.Then,the automatic inclinometer calibration control process and the digital inclinometer zero-setting function were formulated.For display tube recognition,a new display tube recognition algorithm combining threading method and feature extraction method was proposed.Finally,the calibration system was calibrated by photoelectric autocollimator and regular polygon mirror,and the calibration system error and repeatability were calculated via a series of experiments.The experimental results showed that the indication error of the proposed calibration system was less than 4",and the repeatability was 3.9".A digital inclinometer with the resolution of 0.1°was taken as a testing example,within the calibration points'range of[-90°,90°],the repeatability of the testing was 0.085°,and the whole testing process was less than 90 s.The digital inclinometer indication error is mainly introduced by the digital inclinometer resolution according to the uncertainty evaluation. 展开更多
关键词 digital inclinometer automatic calibration high-precision turntable number recognition
原文传递
A novel external online calibration system for polarization detection
4
作者 Li Zishuo He Honghui Wu Jian 《Journal of Innovative Optical Health Sciences》 2025年第5期33-44,共12页
In clinical environments,the prolonged utilization of polarization equipment can result in theaccumulation of errors over extended periods.The absence of expeditious calibration techniques in clinical practice present... In clinical environments,the prolonged utilization of polarization equipment can result in theaccumulation of errors over extended periods.The absence of expeditious calibration techniques in clinical practice presents a significant obstacle in preserving the precision and dependability of these instruments.To address this challenge,we propose an innovative research study that presents a comprebersive calibration system specifically designed for the calibration of the backscattering Muellet matrix measurement system,enabling swift online calibration acroes various scenarios.This system employs an external calibration framework for rmal-time adjust-ment of the polarizer's initial angle,oversecing the rotation of PSG and PSA motors through position measurement and control procedures,with light intensity monitored by a camera.By incorporating moment um concepts and the Adam optimization algorithm,we enhance conver-gence speed,mitigate noise,and improve calibration accuracy.Experimental results showcase the exceptional precision,speed,and robustness of oрroposed method,achieving high acсuracy and minimal error,thereby offering a promising solution for maintaining the reliabilit y of polarization equipment in clinical settings. 展开更多
关键词 DOTP external calibration system polarization detection
原文传递
A novel vector magnetic measurement system calibration method based on geomagnetic variation
5
作者 Ji-hao Liu Xi-hai Li +2 位作者 Chao Niu Xiao-niu Zeng Yun Zhang 《Applied Geophysics》 2025年第1期35-42,232,共9页
Vector magnetic measurement is increasingly widely used.In order to improve the accuracy of vector magnetic measurement system on board a vehicle,researchers have proposed various calibration methods.Most of them requ... Vector magnetic measurement is increasingly widely used.In order to improve the accuracy of vector magnetic measurement system on board a vehicle,researchers have proposed various calibration methods.Most of them require altering the magnetic vector in the vehicle coordinate system.Exploring the use of geomagnetic variation to change the geomagnetic vector in the vehicle coordinate system,this paper proposes a novel vector magnetic measurement calibration method.In this method,a vector magnetometer mounted on a vehicle and an accurate vector magnetometer separately measure the geomagnetic field at diff erent locations within the same area.Based on the physical principle that the geomagnetic variation at two nearby locations is equal,the calibration parameters of the magnetometer on the vehicle can be determined through a set of equations containing the measurements from the two magnetometers.The theoretical derivation and simulation experiment results demonstrate the feasibility of this method.Therefore,it can serve as a new alternative calibration method,especially in scenarios where a high degree of accuracy in the estimation of calibration parameters is not required. 展开更多
关键词 vector magnetic measurement CALIBRATION geomagnetic variation
在线阅读 下载PDF
Systematic calibration of a 2-m Ring Solar Telescope based on local interferometry and model comparison
6
作者 Renai Liu Jinpeng Li +2 位作者 Zuozifei Song Changyu Zeng Yichun Dai 《Astronomical Techniques and Instruments》 2025年第3期175-185,共11页
To address the installation challenges of a 2-m ring Gregorian telescope system,and similar optical systems with a small width-to-radius ratio,we propose a detection method combining local interferometry with a compar... To address the installation challenges of a 2-m ring Gregorian telescope system,and similar optical systems with a small width-to-radius ratio,we propose a detection method combining local interferometry with a comparison model.This method enhances the precision of system calibration by establishing a dataset that delineates the relationship between secondary mirror misalignment and wavefront aberration,subsequently inferring the misalignment from interferometric detection results during the calibration process.For the 2-m ring telescope,we develop a detection model using five local sub-apertures,enabling a root-mean-square detection accuracy of 0:0225λ(λ=632:8 nm)for full-aperture wavefront aberration.The calibration results for the 2-m Ring Solar Telescope system indicate that the root-mean-square value of sub-aperture wavefront aberration reaches 0.104λ,and the root-mean-square value of spliced full-aperture measurement yields reaches 0.112λ.This method offers a novel approach for calibrating small width-toradius ratio telescope systems and can be applied to the calibration of other irregular-aperture optical systems. 展开更多
关键词 Local aperture Model comparison 2-m Ring Solar Telescope system calibration Splicing algorithm
在线阅读 下载PDF
Error Analysis and Compensation of Strapdown Inertial Navigation System 被引量:16
7
作者 刘勤 刘莉 祁载康 《Journal of Beijing Institute of Technology》 EI CAS 2002年第2期117-120,共4页
Based on error analysis, the influence of error sources on strapdown inertial navigation systems is discussed. And the maximum permissible component tolerances are established. In order to achieve the desired accuracy... Based on error analysis, the influence of error sources on strapdown inertial navigation systems is discussed. And the maximum permissible component tolerances are established. In order to achieve the desired accuracy (defined by circular error probability), the types of appropriate sensors are chosen. The inertial measurement unit (IMU) is composed of those sensors. It is necessary to calibrate the sensors to obtain their error model coefficients of IMU. After calibration tests, the accuracy is calculated by uniform design method and it is proved that the accuracy of IMU is satisfied for the desired goal. 展开更多
关键词 error analysis strapdown inertial navigation system uniform design method calibration test
在线阅读 下载PDF
Reconstruction of shock wave pressure field based on distributed test system 被引量:1
8
作者 冯浩 张志杰 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2015年第1期25-29,共5页
A new distributed test system composed of multiple test nodes was designed by adopting storage test technology to test shock waves in explosion field. The advantage of the system is the application of sensor lattice w... A new distributed test system composed of multiple test nodes was designed by adopting storage test technology to test shock waves in explosion field. The advantage of the system is the application of sensor lattice whose rise time is microsecond level, which can quickly response to transient shock wave signals. In order to reduce dynamic response error, shock tube is employed to conduct dynamic calibration on the system. The overpressure peak values of the explosion shock wave collected by sensor lattice were used to construct a shock wave pressure field with B-spline interpolation algorithm. 展开更多
关键词 distributed test system dynamic calibration interpolation algorithm RECONSTRUCTION
在线阅读 下载PDF
Calibration Scheme Under Spherical Coordinates for Magnetic Tracker Used in VR System
9
作者 徐彤 刘莉萍 +1 位作者 刘越 王涌天 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期256-258,共3页
A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, ... A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, spe cified in spherical coordinates, is generated first, which is then used to calibrate the tracking results by a two dimensional interpolation. The scheme can effectively correct the static errors in the magnetic tracking system. The employment of spherical coordinates significantly reduces the calculation complexity in calibration. 展开更多
关键词 CALIBRATION magnetic tracking virtual reality
在线阅读 下载PDF
Greedy calibration method for binocular camera system via characteristic homography matrix
10
作者 刘天亮 金飞逸 罗立民 《Journal of Southeast University(English Edition)》 EI CAS 2009年第2期193-198,共6页
A plane-based and linear camera calibration technique without considering lens distortion is proposed in a greedy and intuitive framework for the binocular camera system. Characteristic homography matrix and consisten... A plane-based and linear camera calibration technique without considering lens distortion is proposed in a greedy and intuitive framework for the binocular camera system. Characteristic homography matrix and consistency constraints in close range are employed in this calibration. First, in order to calculate the internal geometries of the cameras, total least-square fitting as a robust tool for the geometrical cost function is exploited to recover the accurate principal point of each camera from all the characteristic lines of the homography matrices for all model planes. Secondly, generic prior knowledge of the aspect ratio of pixel cells is incorporated into the system to obtain the exact principal length in each camera. Thirdly, extrinsic geometries are accurately computed for all planar patterns with respect to each monocular camera. Finally, the rigid displacement between binocular cameras can be obtained by imposing the consistency constraints in 3-space geometry. Both simulation and real image experimental results indicate that reasonably reliable results can be obtained by this technique. And the proposed method is sufficient for applications where high precision is not required and can be easily performed by common computer users who are not experts in computer vision. 展开更多
关键词 close range CALIBRATION homography matrix consistency constraint STEREOVISION
在线阅读 下载PDF
Systematic Geometric Error Modeling for Workspace Volumetric Calibration of a 5-axis Turbine Blade Grinding Machine 被引量:30
11
作者 Abdul Wahid Khan 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2010年第5期604-615,共12页
A systematic geometric model has been presented for calibration of a newly designed 5-axis turbine blade grinding machine. This machine is designed to serve a specific purpose to attain high accuracy and high efficien... A systematic geometric model has been presented for calibration of a newly designed 5-axis turbine blade grinding machine. This machine is designed to serve a specific purpose to attain high accuracy and high efficiency grinding of turbine blades by eliminating the hand grinding process. Although its topology is RPPPR (P: prismatic; R: rotary), its design is quite distinct from the competitive machine tools. As error quantification is the only way to investigate, maintain and improve its accuracy, calibra- tion is recommended for its performance assessment and acceptance testing. Systematic geometric error modeling technique is implemented and 52 position dependent and position independent errors are identified while considering the machine as five rigid bodies by eliminating the set-up errors of workpiece and cutting tool. 39 of them are found to have influential errors and are accommodated for finding the resultant effect between the cutting tool and the workpiece in workspace volume. Rigid body kinematics techniques and homogenous transformation matrices are used for error synthesis. 展开更多
关键词 5-axis machine tools CALIBRATION modeling geometric errors kinematics homogenous transformation matrices
原文传递
Optics‑guided Robotic System for Dental Implant Surgery 被引量:7
12
作者 Biao Yan Wenlong Zhang +9 位作者 Lijing Cai Lingxiang Zheng Kaiyang Bao Yuming Rao Lin Yang Weitao Ye Peifeng Guan Wei Yang Jiang Li Rongqian Yang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2022年第3期135-147,共13页
At present,dental implant surgery mainly relies on the clinical experience of the doctor and the assistance of preoperative medical imaging.However,there are some problems in dental implant surgery,such as narrow spac... At present,dental implant surgery mainly relies on the clinical experience of the doctor and the assistance of preoperative medical imaging.However,there are some problems in dental implant surgery,such as narrow space,sight obstruction,inaccurate positioning,and high requirements of doctors’proficiency.Therefore,a dental implant robot system(DIRS)guided by optical navigation is developed in this study,with an x-shaped tool and an irregular pentagonal tracer are designed for spatial registration and needle tip positioning strategy respectively.The coordinate system of each unit in DIRS is unified through system calibration,spatial registration,and needle tip positioning strategy.Then the surgical path is planned on the computed tomography(CT)images in the navigation software before operation.The automatic positioning method and the auxiliary positioning method can be used in the operation to achieve accurate positioning and assist doctors to complete the operation.The errors of spatial registration,needle tip positioning strategy,and the overall accuracy of the system were evaluated respectively,and the results showed that they all met the needs of clinical surgery.This study preliminarily verified the feasibility of the precise positioning method for dental surgery robots and provided certain ideas for subsequent related research. 展开更多
关键词 Dental implant surgery Robot system CALIBRATION REGISTRATION
在线阅读 下载PDF
Research on geo-electrical resistivity observation system specially used for earthquake monitoring in China 被引量:8
13
作者 Jialiu Zhao Lanwei Wang Jiadong Qian 《Earthquake Science》 CSCD 2011年第6期497-511,共15页
This paper deals with the design and development of the observational system of geo-electrical resistivity on the basis of the demands for exploring the temporal variations of electrical properties of Earth media in t... This paper deals with the design and development of the observational system of geo-electrical resistivity on the basis of the demands for exploring the temporal variations of electrical properties of Earth media in the fixed points of the networks, which would be associated with the earthquake preparation. The observation system is characterized by the high accuracy in measurement, long term stability in operation and high level of rejection to the environmental interference. It consists of three main parts, configuration system measurement system, the calibration and inspection system. 展开更多
关键词 geo-electrical resistivity observation system earthquake monitoring configuration system measurement system calibration and inspection system
在线阅读 下载PDF
Global Calibration Method of Multi-sensor Vision System Using Skew Laser Lines 被引量:7
14
作者 LIU Qianzhe SUN Junhua +1 位作者 LIU Zhen ZHANG Guangjun 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第2期405-410,共6页
Multi-sensor vision system plays an important role in the 3D measurement of large objects.However,due to the widely distribution of sensors,the problem of lacking common fields of view(FOV) arises frequently,which m... Multi-sensor vision system plays an important role in the 3D measurement of large objects.However,due to the widely distribution of sensors,the problem of lacking common fields of view(FOV) arises frequently,which makes the global calibration of the vision system quite difficult.The primary existing solution relies on large-scale surveying equipments,which is ponderous and inconvenient for field calibrations.In this paper,a global calibration method of multi-sensor vision system is proposed and investigated.The proposed method utilizes pairs of skew laser lines,which are generated by a group of laser pointers,as the calibration objects.Each pair of skew laser lines provides a unique coordinate system in space which can be reconstructed in certain vision sensor's coordinates by using a planar pattern.Then the geometries of sensors are computed under rigid transformation constrains by taking coordinates of each skew lines pair as the intermediary.The method is applied on both visual cameras with synthetic data and a real two-camera vision system;results show the validity and good performance.The prime contribution of this paper is taking skew laser lines as the global calibration objects,which makes the method simple and flexible.The method need no expensive equipments and can be used in large-scale calibration. 展开更多
关键词 multi-vision system global calibration non-overlapping cameras skew laser lines
在线阅读 下载PDF
Growing Operational Use of FY-3 Data in the ECMWF System 被引量:6
15
作者 Niels BORMANN David DUNCAN +5 位作者 Stephen ENGLISH Sean HEALY Katrin LONITZ Keyi CHEN Heather LAWRENCE Qifeng LU 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2021年第8期1285-1298,共14页
This paper reviews the data quality and impact of observations from the FY-3 satellite series used operationally in the ECMWF system. This includes data from the passive microwave radiometers MWHS-1, MWHS-2 and MWRI, ... This paper reviews the data quality and impact of observations from the FY-3 satellite series used operationally in the ECMWF system. This includes data from the passive microwave radiometers MWHS-1, MWHS-2 and MWRI, as well as observations from the radio occultation receiver GNOS. Evaluations against background equivalents show that the quality of the observations is broadly comparable to that of similar instruments on other polar-orbiting satellites, even though biases for the passive microwave observations can be somewhat larger and more complex for some channels. An observing system experiment shows that the FY-3 instruments jointly contribute significantly to the forecast skill in the ECMWF system. Positive impact of up to 2% is seen for most variables out to the day-2 forecasts over hemispheric scales, with significant benefits for total column water vapor or for temperature and wind in the stratosphere out to day 4. 展开更多
关键词 FY-3 satellite series ASSIMILATION forecast impact calibration/validation
在线阅读 下载PDF
High-precision and wide-range real-time neutron flux monitor system through multipoint linear calibration 被引量:6
16
作者 Ren-Jie Zhu Xiang Zhou +9 位作者 Zi-Hao Liu Wen-Di Wang Xiao-Li Mou Teng-Fei Fang Qing-Li Ma Xiu-Feng Xu Guo-Liang Yuan Li Zhao Ling-Feng Wei Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第9期98-106,共9页
The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test rea... The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results. 展开更多
关键词 Multipoint linear calibration Real time Simulated neutron signal Neutron flux monitoring ITER HL-2A
在线阅读 下载PDF
Calibration method of phase distortions for cross polarization channel of instantaneous polarization radar system 被引量:7
17
作者 Huanyao Dai Yuliang Chang Dahai Dai Yongzhen Li XuesongWang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2010年第2期211-218,共8页
A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarizati... A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarization radar ([PR) has inherent cross-polarization measurement error. The proposed method can effectively eliminate this error, and thus enhance the polarization scattering matrix (PSM) measurement precision. The phase error caused by digital receiver's direct IF sampling and mixing of two orthogonal polarization channels can be removed. Consequently, the inherent error of target polarization scattering measurement of the instantaneous polarization radar system is well revised. It has good reference value for further ploarimetric calibration and high practical application prospect. 展开更多
关键词 instantaneous polarization radar target scattering ma- trix (PSM) polarization measurement polarimetric calibration.
在线阅读 下载PDF
An innovative method for calibrating local cooling rate in electroslag remelting of M42 high-speed steel 被引量:3
18
作者 Wan-ming Li Shi-chao Jiao +5 位作者 Wen-jie Tong Xi-min Zang De-jun Li Zhou-hua Jiang Hua-bing Li Yu-an Jing 《Journal of Iron and Steel Research International》 SCIE EI CSCD 2021年第8期990-996,共7页
The determination of the local cooling rate has a great significance in optimizing the parameters of electroslag remelting(ESR)and improving the quality of the ingots.An innovative method was proposed for calibrating ... The determination of the local cooling rate has a great significance in optimizing the parameters of electroslag remelting(ESR)and improving the quality of the ingots.An innovative method was proposed for calibrating the local cooling rate of M42 high-speed steel(HSS)in the ESR process.After resolidification at different cooling rates under high-temperature laser confocal microscopy,the carbide network spacing of the specimen was observed using a scanning electron microscope.A functional relationship between the cooling rate and average carbide network spacing was established.The average local cooling rate of the solidification process of the M42 HSS ingot was calibrated.The results show that the higher the cool-ing rate,the smaller the network spacing of the carbides.For the steel ingot with a diameter of 360 mm,the average local cooling rate was 0.562℃/s at the surface,0.057℃/s at the position of 0.25D(where D is the diameter of the ingot),and 0.046℃/s at the center of the ingot. 展开更多
关键词 Cooling rate Electroslag remelting CARBIDE Network spacing calibrating High-speed steel
原文传递
A Real-Time System for Monitoring Distant Dynamic Displacement of Structures 被引量:4
19
作者 CHEN Junfeng ZHAO Wenguang +2 位作者 LUO Hongbin LI Penghui WEN Yinping 《Geo-Spatial Information Science》 2008年第1期49-55,共7页
Based on digital image processing technique, a real-time system is developed to monitor and detect the dynamic displacement of engineering structures. By processing pictures with a self-programmed software, the real-t... Based on digital image processing technique, a real-time system is developed to monitor and detect the dynamic displacement of engineering structures. By processing pictures with a self-programmed software, the real-time coordinate of an object in a certain coordinate system can be obtained, and further dynamic displacement data and curve of the object can also be achieved. That is, automatic gathering and real-time processing of data can be carried out by this system simultaneously. For this system, first, an untouched monitoring technique is adopted, which can monitor or detect objects several to hundreds of meters apart; second, it has flexible installation condition and good monitoring precision of sub-millimeter degree; third, it is fit for dynamic, quasi-dynamic and static monitoring of large engineering structures. Through several tests and applications in large bridges, good reliability and dominance of the system is proved. 展开更多
关键词 dynamic displacement real-time monitoring and detecting SUB-PIXEL system calibration dynamic tracking
在线阅读 下载PDF
Calibrating the linearity between grayscale and element content for X-ray KES imaging of alloys 被引量:5
20
作者 Xiao-Lu Ju Biao Deng +7 位作者 Ke Li Fu-Cheng Yu Hai-Peng Zhang Ming-Wei Xu Guo-Hao Du Hong-Lan Xie Bin Li Ti-Qiao Xiao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第1期1-12,共12页
Doped elements in alloys significantly impact their performance.Conventional methods usually sputter the surface material of the sample,or their performance is limited to the surface of alloys owing to their poor pene... Doped elements in alloys significantly impact their performance.Conventional methods usually sputter the surface material of the sample,or their performance is limited to the surface of alloys owing to their poor penetration ability.The X-ray K-edge subtraction(KES)method exhibits great potential for the nondestructive in situ detection of element contents in alloys.However,the signal of doped elements usually deteriorates because of the strong absorption of the principal component and scattering of crystal grains.This in turn prevents the extensive application of X-ray KES imaging to alloys.In this study,methods were developed to calibrate the linearity between the grayscale of the KES image and element content.The methods were aimed at the sensitive analysis of elements in alloys.Furthermore,experiments with phantoms and alloys demonstrated that,after elaborate calibration,X-ray KES imaging is capable of nondestructive and sensitive analysis of doped elements in alloys. 展开更多
关键词 X-ray KES imaging Grayscale calibration Element analysis for alloy Nondestructive imaging of elements
在线阅读 下载PDF
上一页 1 2 67 下一页 到第
使用帮助 返回顶部