期刊文献+
共找到1,615篇文章
< 1 2 81 >
每页显示 20 50 100
Percutaneous Transcatheter Closure of Congenital Atrial Septal Defectwith Scoliosis under Transthoracic Echocardiography Guidance
1
作者 Yaqi Tang Gang Luo +2 位作者 Huashu Liu Hao Wan Silin Pan 《Congenital Heart Disease》 2025年第2期195-200,共6页
Congenital atrial septal defect(ASD)with severe scoliosis is a rare compound malformation inchildren.Severe sco liosis should be corrected as soon as possible.The growth rod is suitable for patients withearly scoliosi... Congenital atrial septal defect(ASD)with severe scoliosis is a rare compound malformation inchildren.Severe sco liosis should be corrected as soon as possible.The growth rod is suitable for patients withearly scoliosis and obvious scoliosis under 10 years old.However,the fluoroscopic radiopaque of titaniumalloy plate will inevitably partly make the operative field of interventional occlusion blind.We presenta7-year-old Chinese girl with ASD and scoliosis who underwent spinal correction with a dual-growthrod.In this case,we performed transcatheter closure of ASD solely under the guidance of transthoracicechocardiography.Transthoracic echocardiography(TTE)has been reported as efficacious and safe forassessment and guidance of ASD occlusion.For patients with visual field occlusion under fluoroscopy,theapplication of TTE is efficacious and safe for assessmnent and guidance of ASD occlusion. 展开更多
关键词 atrial septal defect SCOLIOSIS transthoracic echocardiography in tervention closure CHILD
暂未订购
Transcatheter atrial septal defects and patent foramen ovale closure:Medicare utilization and reimbursements
2
作者 Vidit Majmundar Rohan Deo +3 位作者 Ajay Kumar Mishra Peng-Yang Li Marina Byer Rhea Sancassani 《World Journal of Methodology》 2025年第4期225-231,共7页
BACKGROUND The Food and Drug Administration has approved percutaneous atrial septal defect(ASD)and patent foramen ovale(PFO)closure devices for hemodynamically significant interatrial shunts,paradoxical emboli includi... BACKGROUND The Food and Drug Administration has approved percutaneous atrial septal defect(ASD)and patent foramen ovale(PFO)closure devices for hemodynamically significant interatrial shunts,paradoxical emboli including stroke,and decompression sickness.We aimed to study the trends in utilization and reimbursements of transcatheter ASD/PFO closure devices.AIM To analyze trends in utilization and Medicare reimbursements for transcatheter ASD/PFO closure procedures from 2013 to 2022.METHODS A query of administrative data on United States Medicare beneficiaries undergoing transcatheter ASD/PFO was conducted from 2013 to 2022 using the Centers for Medicare and Medicaid Services Part B National Summary Data File.Inflation adjustments were made using the 2023 Consumer Price Index.Trend analysis was quantified using growth rate and simple linear regression calculations.All analyses were performed using Microsoft Excel 16.77.1(2023).RESULTS The annual number of transcatheter ASD/PFO closure procedures increased by 81%since 2013,with an average yearly growth rate of 44%cases per year(P<0.001).Annual Medicare reimbursements for transcatheter ASD/PFO therapies mirrored the annual procedure trends.The per-case reimbursements decreased by 18%,i.e.,$1128.80 in 2013 and$770.21 in 2022(P<0.001).There was a significant drop in the number of procedures in the year 2020,which correlates to the onset of the coronavirus disease 2019 pandemic,followed by a sharp uptick in the number of cases in 2021 and 2022.CONCLUSION Medicare utilization of transcatheter ASD/PFO closure therapies has grown significantly in procedural volume from 2013 to 2022.However,this has been accompanied by a decrease in per-case reimbursements. 展开更多
关键词 atrial septal defect Patent foramen ovale MEDICARE REIMBURSEMENT Patent foramen ovale closure
暂未订购
Comparative Clinical Outcomes of Right Lateral Thoracotomy and Totally Thoracoscopic Surgery for Adult Patients with Atrial Septal Defect:A Single Center,Retrospective Study
3
作者 Yushen Fang Zechen Li +7 位作者 Jiahong Li Kaiyu Wang Gang Xu Shusheng Wen Jimei Chen Jian Zhuang Haiyun Yuan Xiaobing Liu 《Congenital Heart Disease》 2025年第3期357-368,共12页
Background:Totally thoracoscopic surgery(TTS)and right lateral thoracotomy(RLT)are both extensively utilized in the surgical repair for atrial septal defect(ASD).However,RLT is generally considered in low-weight pedia... Background:Totally thoracoscopic surgery(TTS)and right lateral thoracotomy(RLT)are both extensively utilized in the surgical repair for atrial septal defect(ASD).However,RLT is generally considered in low-weight pediatric patients as a result of restricted surgical exposure.This study aims to introduce an RLT approach for ASD repair in adults and compare its clinical outcomes with TTS.Methods:We conducted a retrospective analysis of the clinical data of 23 adult patients who underwent ASD repair at Guangdong Provincial People’s Hospital between June and October 2024.Patients were divided into two groups based on the surgical approach they adopted:group totally thoracoscopic surgery(TTS,n=12)and group right lateral thoracotomy(RLT,n=11).All individuals finished a follow-up three months after surgery.Operative parameters,postoperative courses,echocardiographic measurements and laboratory investigations were compared between the two groups.Results:The total surgical duration was significantly longer in group RLT compared with group TTS[(234.00±47.93)min vs.(175.17±52.36)min,p=0.011].Group RLT exhibited a significantly higher respiratory index(RI)at<6 h postoperatively(1.00±0.58 vs.0.30±0.37,p=0.01)and significantly lower levels of soluble suppression of tumorigenicity 2(sST2)[(136.61±43.12)ng/mL vs.(199.08±33.56)ng/mL,p=0.037]and cardiac troponin(cTnT)[(277.04±89.85)pg/mL vs.(343.30±482.40)pg/mL,p=0.047]at 12-24 h postoperatively.Echocardiographic measurements showed no significant differences between two groups,except for a more pronounced reduction in left atrial(LA)size at discharge in group TTS[(5.00±3.64)mm vs.(0.09±4.44)mm,p=0.008].Conversely,group RLT demonstrated a less significant decrease in glutamyl transpeptidase(GGT)[(1.00±6.00)U/L vs.(5.25±3.86)U/L,p=0.026]but a more significant decrease in blood urea nitrogen(BUN)[(1.81±1.10)mg/dL vs.(0.81±1.07)mg/dL,p=0.038].Conclusions:RLT for ASD repair in adults demonstrated comparable clinical outcomes to TTS in terms of postoperative recovery and cardiac function and also produced fewer scars than TTS.Our study proved the feasibility,safety and cosmetic effects of uniport RLT for ASD repair in adults when compared with TTS. 展开更多
关键词 atrial septal defect right lateral thoracotomy totally thoracoscopic surgery adult patient clinical outcome
暂未订购
The Role of Transesophageal Echocardiography for Transcatheter Closure of Atrial Septal Defects with the Amplatzer Septal Occluder 被引量:1
4
作者 许迪 孔祥清 +3 位作者 杨荣 盛燕辉 曹克将 陆凤翔 《Journal of Nanjing Medical University》 2003年第3期110-115,共6页
Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age... Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age) were selected for percutaneous closure of ASD bytrans-esophageal echocardiography, which was also used to monitor the procedure, to select theappropriate size of the Amplatzer device, to verify its position, and to access the immediateresults of the procedure. During the follow-up, transthoracic echocardiography (TTE) or TEE was usedto evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiacchamber diameters. Results: The mean ASD diameter by TTE ([19. 1 +- 5. 8] mm) was significantlysmaller (P< 0. 001) than the stretched diameter of the ASD (25. 1 +- 6. 4) mm. There are nosignificant differences between the TEE -measured value (23. 5+_6. 2) mm and the stretched diameterof the ASD (P > 0. 05). Due to proper patient selection all procedures were successful. There wasimmediate and complete closure in 61/62 patients, only one patients had trivial residual shunt.Follow- up was performed using TTE or TEE right after operation, 1 d, 1 month, 3 months, 6 monthsand yearly thereafter. Ail, patients remain asymptomatic without any clinical or technical problems.Conclusion: With the aid of TEE, percutaneous closure of ASD can be performed successfully, safely,and effectively. 展开更多
关键词 transesophageal echocardiography atrial septal defects amplatzer septaloccluder
暂未订购
Completed atrioventricular block induced by atrial septal defect occluder unfolding:A case report 被引量:1
5
作者 Chuan He Yang Zhou +2 位作者 Si-Si Tang Li-Hong Luo Kun Feng 《World Journal of Clinical Cases》 SCIE 2020年第22期5715-5721,共7页
BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial se... BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial septal defects(ASDs).CASE SUMMARY A 30-year-old female patient was diagnosed with ASD by transthoracic echocardiography(TTE)1 year ago.The electrocardiogram showed a heart rate of 88 beats per minute,normal sinus rhythm,and no change in the ST-T wave.After admission,TTE showed an atrial septal defect with a left-to-right shunt,aortic root short-axis section with an ASD diameter of 8 mm,a parasternal four-chamber section with an ASD diameter of 9 mm,and subxiphoid biatrial section with a diameter of 13 mm.Percutaneous occlusion was proposed.The intraoperative TTE scan showed that the atrial septal defect was oval in shape,was located near the root of the aorta,and had a maximum diameter of 13 mm.A 10-F sheath was placed in the right femoral vein,and a 0.035°hard guidewire was used to establish the transport track between the left pulmonary vein and the inferior vena cava.A shape-memory alloy atrial septal occluder with a waist diameter of 20 mm was placed successfully and located correctly.TTE showed that the double disk unfolded well and that the clamping of the atrial septum was smooth.Immediately after the disc was revealed,electrocardiograph monitoring showed that the ST interval of the inferior leads was prolonged,the P waves and QRS waves were separated,a junctional escape rhythm maintained the heart rate,and the blood pressure began to decrease.After removing the occluder,the elevation in the ST segment returned to normal immediately,and the sinus rhythm returned to average approximately 10 min later.After consulting the patient’s family,we finally decided to withdraw from the operation.CONCLUSION Compression of the small coronary artery,which provides an alternative blood supply to the atrioventricular nodule during the operation,leads to the emergence of a complete atrioventricular block. 展开更多
关键词 Completed atrioventricular block atrial septal defect occluder atrial septal defect Transthoracic echocardiography Case report
暂未订购
Transcatheter to Close the Patent Duetus Arteriosus and Atrial Septal Defects in Children
6
作者 赵乃琤 王大为 +3 位作者 王凤鸣 龚小平 秦玉明 胡宝珍 《Journal of Nanjing Medical University》 2003年第6期309-312,共4页
Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patient... Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patients with PDA (n = 25) and ASD ( n = 16), confirmed byechocardiography, were treated by transcatheterization. Amplatzer occluder device was placed by thetranscatheterization with the image support of X-ray and transthoracic echocardiography ( TTE) . TheTTE, ECG and X-ray examination were engaged to evaluate the therapeutic results on the time pointsof 24 h , 1, 3 , 6, 12 months after the operation, and all these cases were engaged to the follow-upexamination. Results: The cardioangiographic diameter was 13.0-28.0 mm ([19.3+-4.9] mm) in ASD and2.0-7.7 mm ([3.9+-1.5] mm) in PDA . The diameter of the Amplatzer occluder selected were 13.0-30.0mm ( [20.6+-5.1] mm) in ASD and 4.0-12.0 mm ([6.6+-1.9] mm) in PDA , respectively. All the Amplatzeroccluders were placed successfully. There were no complications during and after the operation.Very small residual shunt was still found soon after the operation in 10 cases , and there were noresidual or recanalization after three months of the operation. The pulmonary artery pressure andheart size were significantly decreased in follow-up examination . Conclusion: Transcatheteringclosure with Amplatzer device is an effective, simple and safe technique in the treatment of ASD andPDA in children. 展开更多
关键词 patent ductus arteriosus atrial septal defects TRANSCATHETER amplatzerdevice
暂未订购
A novel variant in TBX20 (p.DI76N) identified by whole-exome sequencing in combination with a congenital heart disease related gene filter is associated with familial atrial septal defect 被引量:10
7
作者 Ji-jia LIU Liang-liang FAN +2 位作者 Jin-lan CHEN Zhi-ping TAN Yi-feng YANG 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2014年第9期830-837,共8页
Congenital heart disease (CHD) is the leading cause of birth defects, and its etiology is not completely understood. Atrial septal defect (ASD) is one of the most common defects of CHD. Previous studies have demon... Congenital heart disease (CHD) is the leading cause of birth defects, and its etiology is not completely understood. Atrial septal defect (ASD) is one of the most common defects of CHD. Previous studies have demonstrated that mutations in the transcription factor T-box 20 (TBX20) contribute to congenital ASD. Whole-exome sequencing in combination with a CHD-related gene filter was used to detect a family of three generations with ASD. A novel TBX20 mutation, c.526G〉A (p.D176N), was identified and co-segregated in all affected members in this family. This mutation was predicted to be deleterious by bioinformatics programs (SIFT, Polyphen2, and MutationTaster). This mutation was also not presented in the current Single Nucleotide Polymorphism Database (dbSNP) or National Heart, Lung, and Blood Institute (NHLBI) Exome Sequencing Project (ESP). In conclusion, our finding expands the spectrum of TBX20 mutations and provides additional support that TBX20 plays important roles in cardiac development. Our study also provided a new and cost-effective analysis strategy for the genetic study in small CHD pedigree. 展开更多
关键词 Congenital heart disease (CHD) atrial septal defect (ASD) Whole-exome sequencing CHD-relatedgene filter TBX20
原文传递
Percutaneous closure of secundum type atrial septal defects:More than 5-year follow-up 被引量:6
8
作者 Roel JR Snijder Maarten J Suttorp +1 位作者 Jurrien M Ten Berg Martijn C Post 《World Journal of Cardiology》 CAS 2015年第3期150-156,共7页
AIM:To investigate long-term efficacy of two different devices more than five years after percutaneous atrial septal defect(ASD)closure in adults.METHODS:All patients who underwent percutaneous closure of an ASD in th... AIM:To investigate long-term efficacy of two different devices more than five years after percutaneous atrial septal defect(ASD)closure in adults.METHODS:All patients who underwent percutaneous closure of an ASD in the St.Antonius Hospital,Nieuwegein,The Netherlands,between February 1998 and December 2006 were included.Percutaneous closure took place under general anaesthesia and transesophageal echocardiographic moni toring.Transthoracic echocardiography(TTE)was performed 24 h post-procedure to visualize the device position and to look for residual shunting using color Doppler.All complications were registered.All patients were invited for an outpatient visit and contrast TTE more than 5-years after closure.Efficacy was based on the presence of a residual right-to-left shunt(RLS),graded as minimal,moderate or severe.The presence of a residual left-to-right shunt(LRS)was diagnosed using color Doppler,and was not graded.Descriptive statistics were used for patients'characteristics.Univariate analysis was used to identify predictors for residual shunting.RESULTS:In total,104 patients(mean age 45.5±17.1 years)underwent percutaneous ASD closure using an Amplatzer device(ASO)in 76 patients and a Cardioseal/Starflex device(CS/SF)in 28 patients.The mean follow-up was 6.4±3.4 years.Device migration occurred in 4 patients of whom two cases occurred during the index hospitalization(1 ASO,1 CS/SF).The other 2 cases of device migration occurred during the first 6 mo of follow-up(2 CS/SF).The recurrent thrombo-embolic event rate was similar in both groups:0.4%per follow-up year.More than 12 mo post-ASD closure and latest follow-up,new-onset supraventricular tachyarrhythmia's occurred in 3.9%and 0%for the ASO and CS/SF group,respectively.The RLS rate at latest follow-up was 17.4%(minimal 10.9%,moderate 2.2%,severe 4.3%)and 45.5%(minimal 27.3%,moderate 18.2%,severe 0%)for the ASO-and CS/SF groups,respectively.There was no residual LRS in both groups.CONCLUSION:Percutaneous ASD closure has good long-term safety and efficacy profiles.The residual RLS rate seems to be high more than 5 years after closure,especially in the CS/SF.Residual LRS was not observed. 展开更多
关键词 Percutaneous intervention atrial septal defect Closure device Right-to-left interatrial shunt Left-to-right interatrial shunt ECHOCARDIOGRAPHY
暂未订购
Misdiagnosis of unroofed coronary sinus syndrome as an ostium primum atrial septal defect by echocardiography:A case report 被引量:5
9
作者 Jin-Ling Chen Cai-Gui Yu +1 位作者 Dai-Jiao Wang Hong-Bin Chen 《World Journal of Clinical Cases》 SCIE 2022年第5期1592-1597,共6页
BACKGROUND Unroofed coronary sinus syndrome(UCSS)is a rare congenital heart disease,which has variable morphologic features and is strongly associated with persistent left superior vena cava(PLSVC).However,it is often... BACKGROUND Unroofed coronary sinus syndrome(UCSS)is a rare congenital heart disease,which has variable morphologic features and is strongly associated with persistent left superior vena cava(PLSVC).However,it is often difficult to visualize the left-to-right shunt pathway through the CS by transthoracic echocardiography(TTE).CASE SUMMARY A 37-year-old female was admitted to the hepatological surgery department of a hospital with complaint of subxiphoid pain that had started 1 wk prior.Physical examination revealed a grade 3/6 systolic murmur at the left margin of the sternum,between the 2nd and 3rd intercostal cartilage.The patient underwent echocardiography and was diagnosed with ostium primum atrial septal defect(ASD);thus,she was subsequently transferred to the cardiovascular surgery department.A second TTE evaluation before surgery showed type IV UCSS with secundum ASD.Right-heart contrast echocardiography(RHCE)showed that the right atrium and right ventricle were immediately filled with microbubbles,but no microbubble was observed in the CS.Meanwhile,negative filling was observed at the right atrium orifice of the CS and right atrium side of the secundum atrial septal.RHCE identified UCSS combined with secundum ASD but without PLSVC in this patient.CONCLUSION This rare case of UCSS highlights the value of TTE combined with RHCE in confirming UCSS with ASD or PLSVC. 展开更多
关键词 Congenital heart disease Coronary sinus atrial septal defect Persistent left superior vena cava ECHOCARDIOGRAPHY Right heart contrast echocardiography Case report
暂未订购
Home-made fenestrated amplatzer occluder for atrial septal defect and pulmonary arterial hypertension 被引量:3
10
作者 Fabio Dell'Avvocata Gianluca Rigatelli Paolo Cardaioli Massimo Giordan 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2011年第2期127-129,共3页
We report the management of a patient with secundum atrial septal defect (ASD) and severe pulmonary hypertension. A 65-year-old male with recently diagnosed atrial septal defect was referred to our centre for decomp... We report the management of a patient with secundum atrial septal defect (ASD) and severe pulmonary hypertension. A 65-year-old male with recently diagnosed atrial septal defect was referred to our centre for decompensated right heart failure with rest and exercise induced dispnea and severe pulmonary hypertension. Right heart catheterization confirmed a mean pulmonary pressure of about 55 mmHg and a Qp/Qs of 2.7. An occlusion test with a compliant large balloon demonstrated partial fall of pulmonary arterial pressure. The implantation of a home-made fenestrated Amplatzer ASD Occluder (ASO) was planned in order to decrease left-to-right shunt and promote further decrease of pulmonary arterial pressure in the long-term. Thus, by means of mechanical intracardiac echocardiography study with a 9F 9 MHz Ultralce catheter (Boston Scientific Corp.), we selected a 34 mm ASO for implantation. Four millimeter fenestration was made inflating a 4 mm non-compliant coronary balloon throughout the waist of the ASO, which was successfully implanted under intmcardiac echocardiography. After six months, a decrease of pulmonary arterial pressure to 24 mmHg and full compensated right heart failure was observed on transthoracic echocardiography and clinical examination. This case suggests that Wanscatheter closure with home-made fenestrated ASD in elderly patients with severe pulmonary hypertension is feasible. 展开更多
关键词 atrial septal defect pulmonary arterial hypertension interventional therapy
在线阅读 下载PDF
Delayed cardiac tamponade after simultaneous transcatheter atrial septal defect closure and left atrial appendage closure device implantation: a particular case report 被引量:2
11
作者 Jian-Ming WANG Qi-Guang WANG Xian-Yang ZHU 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2019年第12期898-901,共4页
Percutaneous left atrial appendage(LAA)occlusion evolved as an alternative treatment to the patients who are contraindicated or cannot tolerate oral anticoagulants with nonvalvular atrial fibrillation(AF)at risk of st... Percutaneous left atrial appendage(LAA)occlusion evolved as an alternative treatment to the patients who are contraindicated or cannot tolerate oral anticoagulants with nonvalvular atrial fibrillation(AF)at risk of stroke or systemic embolism.[1]Abnormal hemodynamic changes in elder atrial septal defect(ASD)patients cause remodeling of the left atrium,which eventually leads to right heart failure.[2]As the ASDs elderly are associated with a higher incidence of AF,simultaneous transcatheter ASD and LAA closure has become a new effective therapeutic strategy.However,only a limited number of articles involving cardiac tamponade complications have been published in the literature.What’s more,previous studies involving early hemodynamically irrelevant pericardial effusion after the procedure attribute to multiple repositioning attempts of LAA occluder or delivery sheath injured the atrial wall. 展开更多
关键词 atrial fibrillation atrial septal defect Cardiac catheterization Cardiac tamponade Left atrial appendage
暂未订购
Usefulness of myocardial performance index for assessing right ventricular function after percutaneous closure of atrial septal defect 被引量:2
12
作者 Jingdong Ding Genshan Ma +4 位作者 Yaoyao Huang Xiaoli Zhang Jian Zhu Rong Yang Fengxiang Lu 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2007年第4期220-224,共5页
Objective Assessment of right ventricular function in patients with atrial septal defect(ASD)is difficult.The Doppler myocardial performance index(MPI)may provide a method of assessing function in these patients.The p... Objective Assessment of right ventricular function in patients with atrial septal defect(ASD)is difficult.The Doppler myocardial performance index(MPI)may provide a method of assessing function in these patients.The purposes of this study were to evaluate the right ventricular function and its changes in patients with ASD after transcatheter closure of ASD.Methods MPI,defined as the sum of isovolumic relaxation time and isovolumic contraction time derived by ejection time,was measured from tricuspid inflow and right ventricular outflow;Doppler velocity profiles recorded during routine echocardiography.Twenty nine patients(13 men,16 women;mean age 25.28±12.69,range 6 to 57 years)were diagnosed to secundum ASD[the stretched diameters of ASD were from 9 To 36(24.91±7.98)mm],and had a successfully placed Amplatzer septal occluder(ASO)(the sizes of ASO were from 11 to 40 mm);there were 81 sex-matched,age-matched healthy people(control group 41men,40 women;mean age 29.02±14.22,range 4 to 45 years).MPI was measured again on 3 days and 1 month after closure of ASD.Change in the study group was assessed and compared to the control subjects with structurally normal hearts.A complete 2-dimensional and Doppler echocardiographic examination was performed in all study groups.Results 1)The isovolumic relaxation and isovolumic contraction times[respectively(77.59±14.39)ms vs(60.93±12.94)ms,P<0.0001;(28.28±10.88)ms vs(23.64±9.01)ms,P=0.027]were prolonged,and ejection time[(260.65±21.86)ms vs(271.85±21.92)ms,P=0.033]was shortened in patients with ASD compared with that in control subjects,resulting in a marked increase in the MPI(0.40±0.07 vs 0.31±0.05,P<0.0001)from normal values;2)by Pearson's correlations,the MPI had no correlation with heart rate and blood pressure in control subjects and patients with ASD,but it correlated positively with age in patients with ASD;3)by Pearson's correlations,the MPI correlated positively with the diameter of ASD and pulmonary artery pressure;4)after transcatheter closure of ASD,the MPI decreased markedly.Conclusions 1)MPI is a conceptually new,simple,and reproducible Doppler index in patients with ASD;2)MPI is free from the effect of age,heart rate and blood pressure;(3)MPI appears to be relatively dependent on changes in the diameter of ASD and pulmonary artery pressure;4)the right ventricular function was improved after transcatheter closure of ASD. 展开更多
关键词 HEART atrial septal defect right ventricular function myocardial performance index
暂未订购
Genetic Analysis of Variants of the MYH6 Gene Promoter in Congenital Atrial Septal Defects 被引量:2
13
作者 Ji-Yang Zuo Huan-Xin Chen +2 位作者 Zhi-Gang Liu Qin Yang Guo-Wei He 《Congenital Heart Disease》 SCIE 2023年第1期7-21,共15页
Background:Atrial septal defect(ASD)is one of the common congenital heart diseases.The MYH6 gene has a critical role in cardiac development but the role of MYH6 promoter variants in patients with ASD has not been expl... Background:Atrial septal defect(ASD)is one of the common congenital heart diseases.The MYH6 gene has a critical role in cardiac development but the role of MYH6 promoter variants in patients with ASD has not been explored.Methods:In 613 subjects including 320 ASD patients,we investigated the MYH6 gene promoter variants and verified the effect on gene expression by using cellular functional experiments and bioinformatics analysis.Results:Eleven variants were identified in the MYH6 gene promoter,of which four variants were found only in ASD patients,and two variants(g.3434G>C and g.4524C>T)were identified for the first time.Cellular functional experiments indicated that all four variants reduced the transcriptional activity of the MYH6 gene promoter(p<0.05).Subsequent analysis through the JASPAR(A database of transcription factor binding profiles)suggests that these variants may alter transcription factor binding sites,which may in turn lead to changes in myocardin subunit expression and ASD formation.Conclusions:Our study for the first time focuses on variants in the promoter region of the MYH6 gene in Chinese patients with ASD and the discovered variants have functional significance.The study provides new insights in the role of the MYH6 gene promoter region to better understand the genetic basis of ASD formation and facilitates clinical diagnosis. 展开更多
关键词 atrial septal defect MYH6 GENETIC VARIANTS congenital heart disease
暂未订购
Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings 被引量:2
14
作者 Saumu Tobbi Mweri 邓又斌 +12 位作者 程佩萱 林汉华 王宏伟 Ommari Baaliy Mkangara 夏治 胡秀芬 毕小军 伍玉晗 Mustaafa Bapumiia 申屠伟慧 刘蓉 刘娅妮 朱美华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第2期257-259,共3页
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find... The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. 展开更多
关键词 real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography
暂未订购
Dynamic Characteristic Mechanism of Atrial Septal Defect Using Real-Time Three-Dimensional Echocardiography and Evaluation of Right Ventricular Functions 被引量:7
15
作者 沙仁高娃 张军 +1 位作者 秦川 吕清 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第1期140-147,共8页
The dynamic characteristics of the area of the atrial septal defect(ASD) were evaluated using the technique of real-time three-dimensional echocardiography(RT 3DE), the potential factors responsible for the dynami... The dynamic characteristics of the area of the atrial septal defect(ASD) were evaluated using the technique of real-time three-dimensional echocardiography(RT 3DE), the potential factors responsible for the dynamic characteristics of the area of ASD were observed, and the overall and local volume and functions of the patients with ASD were measured. RT 3DE was performed on the 27 normal controls and 28 patients with ASD. Based on the three-dimensional data workstations, the area of ASD was measured at P wave vertex, R wave vertex, T wave starting point, and T wave terminal point and in the T-P section. The right atrial volume in the same time phase of the cardiac cycle and the motion displacement distance of the tricuspid annulus in the corresponding period were measured. The measured value of the area of ASD was analyzed. The changes in the right atrial volume and the motion displacement distance of the tricuspid annulus in the normal control group and the ASD group were compared. The right ventricular ejection fractions in the normal control group and the ASD group were compared using the RT 3DE long-axis eight-plane(LA 8-plane) method. Real-time three-dimensional volume imaging was performed in the normal control group and ASD group(n=30). The right ventricular inflow tract, outflow tract, cardiac apex muscular trabecula dilatation, end-systolic volume, overall dilatation, end-systolic volume, and appropriate local and overall ejection fractions in both two groups were measured with the four-dimensional right ventricular quantitative analysis method(4D RVQ) and compared. The overall right ventricular volume and the ejection fraction measured by the LA 8-plane method and 4D RVQ were subjected to a related analysis. Dynamic changes occurred to the area of ASD in the cardiac cycle. The rules for dynamic changes in the area of ASD and the rules for changes in the right atrial volume in the cardiac cycle were consistent. The maximum value of the changes in the right atrial volume occurred in the end-systolic period when the peak of the curve appeared. The minimum value of the changes occurred in the end-systolic period and was located at the lowest point of the volume variation curve. The area variation curve for ASD and the motion variation curve for the tricuspid annulus in the cardiac cycle were the same. The displacement of the tricuspid annulus exhibited directionality. The measured values of the area of ASD at P wave vertex, R wave vertex, T wave starting point, T wave terminal point and in the T-P section were properly correlated with the right atrial volume(P〈0.001). The area of ASD and the motion displacement distance of the tricuspid annulus were negatively correlated(P〈0.05). The right atrial volumes in the ASD group in the cardiac cycle in various time phases increased significantly as compared with those in the normal control group(P=0.0001). The motion displacement distance of the tricuspid annulus decreased significantly in the ASD group as compared with that in the normal control group(P=0.043). The right ventricular ejection fraction in the ASD group was lower than that in the normal control group(P=0.032). The ejection fraction of the cardiac apex trabecula of the ASD patients was significantly lower than the ejection fractions of the right ventricular outflow tract and inflow tract and overall ejection fraction. The difference was statistically significant(P=0.005). The right ventricular local and overall dilatation and end-systolic volumes in the ASD group increased significantly as compared with those in the normal control group(P=0.031). The a RVEF and the overall ejection fraction decreased in the ASD group as compared with those in the normal control group(P=0.0005). The dynamic changes in the area of ASD and the motion curves for the right atrial volume and tricuspid annulus have the same dynamic characteristics. RT 3DE can be used to accurately evaluate the local and overall volume and functions of the right ventricle. The local and overall volume loads of the right ventricle in the ASD patients increase significantly as compared with those of the normal people. The right ventricular cardiac apex and the overall systolic function decrease. 展开更多
关键词 ultrasonic cardiography real-time three-dimension atrial septal defect tricuspid annulus right atrium
暂未订购
Clinical Value of Stereoscopic Three-dimensional Echocardiography in Assessment of Atrial Septal Defects: Feasibility and Efficiency 被引量:1
16
作者 王静 王新房 +3 位作者 谢明星 贺林 吕清 王蕾 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第6期791-794,共4页
Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3D... Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tis-sues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89±0.73 cm vs 2.85±0.72 cm, P〉0.05; r=0.96, P〈0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0±3.8 s vs 10.3±3.6 s, P〉0.05). The mean completion time of interven-tional procedure was shortened with S-3DE display as compared with standard 3D display (17.3±3.1 min vs 23.0±3.9 min, P〈0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions. 展开更多
关键词 ECHOCARDIOGRAPHY stereoscopic vision real time THREE-DIMENSION atrial septal defect OCCLUSION
暂未订购
Efficacy and Safety of the Atrial Septal Defect Closure for Patients with Absent or Malaligned Aortic Rim Using a Figulla Flex II Device Flared and Straddling Behind the Aorta 被引量:1
17
作者 Masataka Kitano Kazuto Fujimoto +2 位作者 Atsuko Kato Ken-ichi Kurosaki Isao Shiraishi 《Congenital Heart Disease》 SCIE 2021年第3期269-283,共15页
Background:Although transcatheter closure of atrial septal defect(ASD)is safe and effective for patients with sufficient rim,ASD patients with absent and/or malaligned aortic and/or superior rim have higher risks of d... Background:Although transcatheter closure of atrial septal defect(ASD)is safe and effective for patients with sufficient rim,ASD patients with absent and/or malaligned aortic and/or superior rim have higher risks of device embolization and cardiac erosion.We have treated such high-risk patients using a Figulla Flex II(FFII)device shaped flared and straddling behind the aorta because this method would avoid such serious complications.However,its long-term efficacy and safety remain unclear.Therefore,the midterm efficacy and safety of this method were studied.Methods:We retrospectively evaluated the outcome of 47 consecutive patients with such rim(age 6–73 years,weight 17–75 kg,31 females)treated with this method at our hospital between February 2016 and September 2019.To make the flared and straddling shape,we selected a FFII 4–6 mm larger than the balloon sizing diameter by stop-flow technique.We also studied the device shape,the disc pressure to the Valsalva wall and their changes over 6 months by transesophageal echocardiography.Results:All procedures were successful,and leakage disappeared within 1 year.During a mean follow up of 37±12 months,complications included a transient sinus node dysfunction and one I°atrioventricular block within 3 months.Whole device shape changed from bulky to thin:the device waist and thickness significantly decreased by around 1.5 mm and 3.5 mm,respectively(p<0.05),but the two discs remained flared and straddling behind the aorta over 6 months;therefore,the disc edges seldom pressed the Valsalva wall perpendicularly,even though the inner plane of either disc often slightly pressed the wall.Conclusions:ASD closure using a FFII shaped flared and straddling behind the aorta is probably effective and safe for patients with absent and/or malaligned aortic and/or superior rim although requiring care for conduction disorders. 展开更多
关键词 atrial septal defect catheter intervention device embolization cardiac erosion conduction disorder
暂未订购
Outcomes of Three Different Minimal Invasive Approaches for Secundum Atrial Septal Defect Closure: A Single Institute Experience 被引量:1
18
作者 Hao HONG Long WU +2 位作者 Xiao-ke SHANG Wei SU Nian-guo DONG 《Current Medical Science》 SCIE CAS 2021年第6期1225-1230,共6页
Objective:The aims of this retrospective study were to investigate and evaluate the safety and efficacy of three approaches for closure of secundum atrial septal defect(ASD).Methods:In this study,we reviewed clinical ... Objective:The aims of this retrospective study were to investigate and evaluate the safety and efficacy of three approaches for closure of secundum atrial septal defect(ASD).Methods:In this study,we reviewed clinical data for transcatheter occlusion(TCO,n=63),transthoracic occlusion(TTO,n=55),and right anterolateral minithoracotomy(RALT,n=60)techniques used for ASD closure.We compared the safety and efficacy of the three approaches.Results:ASD size in the TTO group was similar to that in the RALT group(P=0.645)and significantly larger than that in the TCO group(P<O.OO1).The RALT group had more non-central types of ASD than the TTO and TCO groups(P=O.019 and P<O.OO1).The operative time in the TTO group was shorter than that in the TCO and RALT groups(P<O.OO1 and P<0.001).The ventilation time and intensive care unit duration were shorter in the TTO group than in the RALT group(P<O.OO1 and P<O.OO1).Hospital duration in the TCO group was shorter than that in the TTO and RALT groups(P<O.OO1 and P<O.OO1).There were no residual shunt and mortality in any group in hospital or during follow-up.There was no significant difference in the incidence of total complications among the three groups(P=0.738).Conclusion:TCO,TTO,and RALT can be performed with favorable cosmetic and clinical results for closing ASD.Appropriate patient selection is an important factor for successful closure.These techniques are promising alternatives to standard median sternotomy and merit additional study. 展开更多
关键词 transcatheter occlusion transthoracic occlusion right anterolateral minithoracotomy secundum atrial septal defect
暂未订购
Cryoballoon pulmonary vein isolation and left atrial appendage occlusion prior to atrial septal defect closure: A case report 被引量:1
19
作者 Yu-Cheng Wu Mei-Xiang Wang +2 位作者 Ge-Cai Chen Zhong-Bao Ruan Qing-Qing Zhang 《World Journal of Clinical Cases》 SCIE 2022年第12期3872-3878,共7页
BACKGROUND In patients who suffer from both atrial fibrillation(AF)and atrial septal defect(ASD),cryoballoon pulmonary vein isolation(PVI),sequential left atrial appendage(LAA)occlusion and ASD closure could be a stra... BACKGROUND In patients who suffer from both atrial fibrillation(AF)and atrial septal defect(ASD),cryoballoon pulmonary vein isolation(PVI),sequential left atrial appendage(LAA)occlusion and ASD closure could be a strategy for effective prevention of stroke and right heart failure.CASE SUMMARY A 65-year-old man was admitted to our institution due to recurrent episodes of palpitations and shortness of breath for 2 years,which had been worsening over the last 48 h.He had a history of AF,ASD,coronary heart disease with stent implantation and diabetes.Physical and laboratory examinations showed no abnormalities.The score of CHA2DS2VASc was 3,and HAS-BLED was 1.Echocardiography revealed a 25-mm secundum ASD.Pulmonary vein(PV)and LAA anatomy were assessed by cardiac computed tomography.PV mapping with 10-pole Lasso catheter was performed following ablation of all four PVs with complete PVI.Following the cryoballoon PVI,the patient underwent LAA occlusion under transesophageal echocardiographic monitoring.Lastly,a 34-mm JIYI ASD occlude device was implanted.A follow-up transesophageal echocardiography at 3 mo showed proper position of both devices and neither thrombi nor leakage was found.CONCLUSION Sequential cryoballoon PVI and LAA occlusion prior to ASD closure can be performed safely in AF patients with ASD. 展开更多
关键词 atrial fibrillation atrial septal defect CRYOBALLOON Pulmonary vein isolation Left atrial appendage occlusion Case report
暂未订购
Perioperative anesthesia management in pediatric liver transplant recipient with atrial septal defect:A case report 被引量:1
20
作者 Lan Liu Pei Chen +1 位作者 Li-Li Fang Li-Na Yu 《World Journal of Clinical Cases》 SCIE 2022年第29期10638-10646,共9页
BACKGROUND Preoperative conditions in pediatric liver transplant recipients are understandably complex.Compared with adults,children have lesser compensatory abilities and demand greater precision during procedural ex... BACKGROUND Preoperative conditions in pediatric liver transplant recipients are understandably complex.Compared with adults,children have lesser compensatory abilities and demand greater precision during procedural executions.In the setting of endstage liver disease,the heightened perioperative risk of coexistent cardiovascular pathology may impact graft survival as well.Requirements for anesthesia and perioperative management are thus more rigorous,calling for individualized treatments that reflect specific cardiovascular constraints and proposed surgical plans.CASE SUMMARY Reports of perioperative anesthesia management and liver transplant prognostication in pediatric patients with concurrent atrial septal defects are scarce.Herein,we detail the course of liver transplantation in a child with dual afflictions,focusing on perioperative anesthesia management and the important contributions of the anesthesiologist(pre-and perioperatively) to a positive therapeutic outcome,despite the clinical hurdles imposed.CONCLUSION Children with atrial septal defects bear substantially more than customary perioperative risk during orthotopic liver transplants,given their compromised cardiopulmonary reserves and functional states.Comprehensive preoperative cardiovascular assessments,including use of agitated-saline contrast echocardiography(to characterize intracardiac shunting) and multidisciplinary deliberation,may offer insights into structural cardiac pathophysiologic effects and transplantrelated hemodynamic changes that impact new grafts.At the same time,active and effective monitoring and other measures should be taken to maintain hemodynamic stability in the perioperative period,avoid entry of bubbles into the circulation,and ease congestion in newly grafted livers.Such efforts are crucial for transplantation success and graft survival. 展开更多
关键词 Pediatric liver transplant atrial septal defect ANESTHESIA Case report
暂未订购
上一页 1 2 81 下一页 到第
使用帮助 返回顶部