Geothermal energy,a form of renewable energy,has been extensively utilized for building heating.However,there is a lack of detailed comparative studies on the use of shallow and medium-deep geothermal energy in buildi...Geothermal energy,a form of renewable energy,has been extensively utilized for building heating.However,there is a lack of detailed comparative studies on the use of shallow and medium-deep geothermal energy in building energy systems,which are essential for decision-making.Therefore,this paper presents a comparative study of the performance and economic analysis of shallow and medium-deep borehole heat exchanger heating systems.Based on the geological parameters of Xi’an,China and commonly used borehole heat exchanger structures,numerical simulationmethods are employed to analyze performance and economic efficiency.The results indicate that increasing the spacing between shallow borehole heat exchangers can effectively reduce thermal interference between the pipes and improve heat extraction performance.As the flow rate increases,the outlet water temperature ranges from 279.3 to 279.7 K,with heat extraction power varying between 595 and 609 W.For medium-deep borehole heat exchangers,performance predictions show that a higher flow rate results in greater heat extraction power.However,when the flow rate exceeds 30 m^(3)/h,further increases in flow rate have only a minor effect on enhancing heat extraction power.Additionally,the economic analysis reveals that the payback period for shallow geothermal heating systems ranges from 10 to 11 years,while for medium-deep geothermal heating systems,it varies more widely from 3 to 25 years.Therefore,the payback period for medium-deep geothermal heating systems is more significantly influenced by operational and installation parameters,and optimizing these parameters can considerably shorten the payback period.The results of this study are expected to provide valuable insights into the efficient and cost-effective utilization of geothermal energy for building heating.展开更多
The vigorous development of modern electronic communication demands multi-functional materials with exceptional electromagnetic interference(EMI)shielding.However,constructing lightweight and highly efficient metal-fr...The vigorous development of modern electronic communication demands multi-functional materials with exceptional electromagnetic interference(EMI)shielding.However,constructing lightweight and highly efficient metal-free carbon-based EMI shielding materials remains a huge challenge,particularly with robust EMI responses across a broadband frequency.Herein,a broadband(8-27 GHz)and strong EMI shielding response nitrogen-doped carbon plate(NCP)is constructed by a pressing and two-step pyroly-sis process.The layered stacking structure and N-doping impart extraordinary EMI shielding performance to the carbon plate,achieving EMI shielding effectiveness values of 82.60,95.44,and 104.12 dB in the X band,Ku band,and K band,respectively.Notably,the overall thickness of NCP was<1 mm.Moreover,the NCP exhibits remarkable joule heating performance with a low driving voltage(≤3 V)and a fast elec-trothermal response.This work enables the potential for the development of metal-free carbon materials with lightweight,highly efficient and broadband-strong EMI shielding performance.展开更多
In order to enhance the off-peak performance of gas turbine combined cycle(GTCC)units,a novel collaborative power generation system(CPG)was proposed.During off-peak operation periods,the remaining power of the GTCC wa...In order to enhance the off-peak performance of gas turbine combined cycle(GTCC)units,a novel collaborative power generation system(CPG)was proposed.During off-peak operation periods,the remaining power of the GTCC was used to drive the adiabatic compressed air energy storage(ACAES),while the intake air of the GTCC was heated by the compression heat of theACAES.Based on a 67.3MW GTCC,under specific demand load distribution,a CPG system and a benchmark system(BS)were designed,both of which used 9.388% of the GTCC output power to drive the ACAES.The performance of the CPG and the BS without intake air heating was compared.The results show that the load rate of the GTCC in the CPG system during off-peak periods is significantly enhanced,and the average operating efficiency of the GTCC is increased by 1.19 percentage points.However,in the BS system,due to the single collaborativemethod of load shifting,the GTCC operative efficiency is almost increased by 1.00 percentage points under different ambient temperatures.In a roundtrip cycle at an ambient temperature of 288.15K,the systemefficiency of the CPG reaches 0.5010,which is 0.62 percentage points higher than the operative efficiency of 0.4948 in the standalone GTCC;while the system efficiency of the BS is slightly inferior to that of the standalone GTCC.The findings confirm the technical feasibility and performance improvement of the ACAES-GTCC collaborative power generation system.展开更多
To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and p...To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and performance of the heat pump part of this new heating system are studied.Based on a SASHP with 10 kW,the mathematical model of this system is built,and the characteristics and performance are concluded from the simulation analysis at different environmental temperatures and output water temperatures.The results show that the performance of heat pumps can be greatly improved based on the new SASHP.When the environmental temperature is 7 ℃,the coefficient of performance(COP)of the air-source heat pump(ASHP)can be increased by 26% at most.This paper sets up a base for further study on the heating system with this new SASHP in the heating season.展开更多
This study presents a simplified numerical approach for evaluating the thermal performance of louvered fin and flat tube heat exchangers(LFFTHXs),which are critical in many thermal management applications but difficul...This study presents a simplified numerical approach for evaluating the thermal performance of louvered fin and flat tube heat exchangers(LFFTHXs),which are critical in many thermal management applications but difficult to model due to their complex geometries.The proposed method uses an equivalent convective heat transfer coefficient to represent the fins,significantly reducing the computational requirements of the simulations.Validation against the effectiveness-number of transfer units method showed average deviations of 4.4%for the novel louvered fin with two combined holes and 9.5%for conventional configurations,confirming the accuracy of the method.Further application to two-phase refrigerant scenarios using experimental data demonstrated the robustness of the method and its suitability for practical design and optimization of LFFTHXs.The approach not only improves the feasibility of thermal analysis in industrial applications but also provides a foundation for future research into more efficient heat exchanger designs.展开更多
In this work,numerical simulations are performed to investigate the influence of combining ribs and triangular cavities on the thermal-hydraulic performance(THP)of MCHS at fluid velocities ranging from1 to 4 m/s(corre...In this work,numerical simulations are performed to investigate the influence of combining ribs and triangular cavities on the thermal-hydraulic performance(THP)of MCHS at fluid velocities ranging from1 to 4 m/s(corresponding to Reynolds numbers(Re)of 129.75 to 519).Specifically,the ribs are positioned on the bottomwall,and the rib width is equal to the mini-channel width,while the triangular cavities are arranged on the two side walls of the MCHS.By analyzing and comparing key parameters such as velocity distribution,streamline patterns,pressure drop,skin friction coefficient(C_(f)),Nusselt number(Nu),friction factor(f),temperature fields,and performance evaluation criterion(PEC),the advantages of rib-cavity coupling configuration in enhancing THP are systematically discussed.Furthermore,the effects of cavity distribution(left,middle,and right),cavity depth(0.04,0.06,and 0.08 mm),and rib height(0.02,0.04,and 0.06 mm)on THP are analyzed to optimize the geometric parameters of the ribs and the cavities.The numerical simulation results indicate that,in comparison to the use of ribs or cavities alone,rib-cavity coupling can further improve the THP ofMCHS without causing a significant increase in pressure drop.The downstreamwall of the cavity is perpendicular to the flow direction which is more favorable for enhancing the heat transfer performance.Increasing the cavity depth improves the heat transfer performance ofMCHS,themaximumNu ratio increase by 35%at a rib height of 0.06 mm.However the increase in the rib height leads to a significant increase in the pressure drop,which in turn exerts a negative impact on THP,a maximumPEC of 1.198 is obtained at a rig height of 0.02 mm.The greatest improvement in THP,reaching 19.8%,is achieved when the cavity depth is 0.08 mm and the rib height is 0.02 mm.展开更多
The behavior of single-phase flow and conjugate heat transfer in micro-channel heat sinks(MCHS)subjected to auniform heat flux is investigated by means of numerical simulations.Various geometrical configurations areex...The behavior of single-phase flow and conjugate heat transfer in micro-channel heat sinks(MCHS)subjected to auniform heat flux is investigated by means of numerical simulations.Various geometrical configurations areexamined,particularly,the combinations of rectangular solid and perforated blocks,used to create a disturbancein the flow.The analysis focuses on several key aspects and related metrics,including the temperature distribution,the mean Fanning friction factor,the pressure drop,the Nusselt number,and the overall heat transfer coefficientacross a range of Reynolds numbers(80–870).It is shown that the introduction of such blocks significantlyenhances the heat transfer performances of the MCHS compared to the straight-through flow channel.Specifically,a case is found where the Nusselt number increases by 2.3 times relative to the reference case.The integrationof perforated blocks facilitates the generation of vorticity within the channel,promoting the mixing of coldand hot fluids.Notably,MCHS incorporating perforated rectangular blocks exhibit more pronounced heat transferbenefits at Reynolds numbers smaller than 400.展开更多
The optimization of working fluids in single-well coaxial geothermal systems presents a critical pathway for advancing the use of enhanced geothermal systems(EGS)in renewable energy applications.This study evaluates t...The optimization of working fluids in single-well coaxial geothermal systems presents a critical pathway for advancing the use of enhanced geothermal systems(EGS)in renewable energy applications.This study evaluates the thermo-hydraulic performance of three working fluids(H_(2)O,CO_(2),and H_(2))in a single-well coaxial geothermal system,focusing on the effects of their injection temperatures.Using a 3D finite element model in COMSOL Multiphysics,simulations were conducted at three injection temperatures(17℃,27℃,40℃)under constant mass flow rates.The results reveal that hydrogen significantly outperforms water and carbon dioxide,achieving a 297.77% and 5453.76% higher thermal output,respectively.Notably,the heat transfer efficiency is significantly improved when the injected working fluids are at 40℃,compared to 27℃;this demonstrates a positive correlation between injection temperature and thermal recovery.Though water systems exhibit better geological compatibility,the superior thermal properties of hydrogen position it as a promising alternative-despite potential subsurface challenges.This study provides critical insights for advancing the application of high-efficiency geothermal systems as well as the development of non-aqueous working fluids,thus contributing to the sustainable utilization of geothermal energy.展开更多
This study involved numerical simulations of a double tube heat exchanger using the ANSYS FLUENT programversion 22.The study aims to examine methods for minimizing pressure loss and consequently enhancing the thermal ...This study involved numerical simulations of a double tube heat exchanger using the ANSYS FLUENT programversion 22.The study aims to examine methods for minimizing pressure loss and consequently enhancing the thermal performance index(TPI)of a heat exchanger fitted with wavy edge tape that is a heat recovery system(the hot air in simulation instead of t heat from the exhaust gases of the brick factory furnaces and return it to warm the heavy fuel oil by substituting the electrical heater with a heat exchanger to recuperate waste heat from the flue gases,so elevating the temperature of Heavy fuel oil(HFO)to inject from the roof nozzles of combustion chamber of the furnace furthermore reducing cost(by finding the optimal design of wavy edge tape))and energy consumption.Air was selected as the hot gas in the inner pipe instead of furnace exhaust gases due to their similar thermal characteristics.A numerical analysis was conducted to create a novel wavy edge tape with varying widths(50%Di,75%Di,and 95%Di),lengths(1000,1200,1400)mm,amplitudes(5,10,15)mm,and periods of wavy length(5,10,15)mm.The flow rate of the outer pipe fluid(oil)ranges from(0.06 to 0.1)kg/s,while the velocity of the hot fluid(air)varies from(1 to 27)m/s,Re_(air)(6957 to 187,837).The entrance temperature of the hot fluid can be either(200,225,and 250)℃.The study finds that wavy edge tape tubes are more effective than smooth tubes in terms of oil outlet temperature;results revealed that an increase in the oil mass flow rate leads to a decrease in the oil outlet temperature and an increase in the heat transfer rate,at the air temperature 250℃.Additionally,the results indicate that increasing the width,length,and amplitude also leads to an increase in the oil outlet temperature of(94-94.12)℃,the pressure drop of(568.3)Pa,and the Nusselt number(65.7-66.5)respectively on the oil side.Finally,the heat exchanger’s best thermal performance index was found by investigating temperature contour at amplitude(A=5),period(p=15),width(w=75%Di),and length(L=1200 mm).The values for these parameters are,in order(1.02,1.025,1.02,and 1.0077).展开更多
La3+ was selected to elevate the lattice electronic conductivity of LiFePO4,and LiFePO4/(C+La3+) cathode powders were synthesized by microwave heating using a domestic microwave oven for 35 min. The microstructures an...La3+ was selected to elevate the lattice electronic conductivity of LiFePO4,and LiFePO4/(C+La3+) cathode powders were synthesized by microwave heating using a domestic microwave oven for 35 min. The microstructures and morphologies of the synthesized materials were investigated by XRD and SEM. The electrochemical performances were evaluated by galvanostatic charge-discharge. The electrochemical performance of LiFePO4 with different La3+ contents was studied. Results indicated that the initial specific disch...展开更多
In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1...In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 ℃) and condenser water inlet temperature(30-50℃). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 ℃ to 17.8 ℃, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 ℃ to 50 ℃. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature.展开更多
The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems.This paper investigated the coupling performance of a cogeneration heating and p...The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems.This paper investigated the coupling performance of a cogeneration heating and power system multidimensionally based on the operating characteristics of the cogeneration units,the hydraulic and thermodynamic characteristics of the heating network,and the energy loads.Taking a steam network supported by a gas-steam combined cycle cogeneration system as the research case,the interaction effect among the source-side prime movers,the heating networks,and the terminal demand thermal parameters were investigated based on the designed values,the plant testing data,and the validated simulation.The operating maps of the gas-steam combined cycle cogeneration units were obtained using THERMOFLEX,and the minimum source-side steam parameters of the steam network were solved using an inverse solution procedure based on the hydro-thermodynamic coupling model.The cogeneration operating maps indicate that the available operating domain considerably narrows with the rise of the extraction steam pressure and flow rate.The heating network inverse solution demonstrates that the source-side steam pressure and temperature can be optimized from the originally designed 1.11 MPa and 238.8°C to 1.074 MPa and 191.15°C,respectively.Under the operating strategy with the minimum source-side heating parameters,the power peak regulation depth remarkably increases to 18.30%whereas the comprehensive thermal efficiency decreases.The operation under the minimum source-side heating steam parameters can be superior to the originally designed one in the economy at a higher price of the heating steam.At a fuel price of$0.38/kg and the power to fuel price of 0.18 kg/(kW·h),the critical price ratio of heating steam to fuel is 119.1 kg/t.The influence of the power-fuel price ratio on the economic deviation appears relatively weak.展开更多
A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water t...A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.展开更多
A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, co...A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, compressed air, glycol water solution and water as the heating fluids, and air and water as the cooling fluids. The heat transfer performance testing of heat exchangers can be conducted not only for a conventional one heating fluid to one cooling fluid, but also for a compound air cooling heat exchanger with two or three heating fluids in parallel or in series. The control and measurement system is implemented based on a LabVIEW software platform, consisting of the data acquisition and process system, and the automotive operation and control system. By using advanced measuring instruments combined with sound computer software control, the testing system has characteristics of a compact structure, high accuracy, a wide range of testing scope and a friendly operation interface. The uncertainty of the total heat transfer coefficient K is less than 5%. The testing system provides a reliable performance testing platform for designing and developing new heat exchangers.展开更多
The objective of the present experimental work is to investigate the performance of a wrapped screen heat pipe for atmospheric air heating to compare with the limits of this pipe. The experiment was conducted using co...The objective of the present experimental work is to investigate the performance of a wrapped screen heat pipe for atmospheric air heating to compare with the limits of this pipe. The experiment was conducted using copper pipe material and acetone as working fluid at different vapor temperatures. The testing also consists of a heater, a blower for heat removal (condenser), temperature measuring device, a vapor temperature probe, acetone charging system, and a vacuum pump. The copper outside diameterof the pipe is 0.022 m, with a total length of 0.6 m. The results showed that the pipe wall temperature (Tw) for a wrapped screen heat pipe has a rapid increase and takes 50 min to reach steady state at (Q = 63 W). The vapour temperature of working fluid increases as the heat load increases at constant air velocity. It was also been found that the range of vapour temperature deceases as the filling ratio increases that means the increasing of the filling ratio results the decrease of the maximum vapour temperature and the variation in the vapour temperature. The best recorded filling ratio is 0.6 which has the lowest vapour temperature at highest heat load. The maximum heat transport limit for this pipe is 80 W and the maximum temperature difference for air is 5。C.展开更多
The performance of a direct-expansion ground-source heat pump(DX GSHP)system is theoretically analyzed.Compared with the conventional ground-source heat pump(GSHP),the DX GSHP has a lower condensing temperature in...The performance of a direct-expansion ground-source heat pump(DX GSHP)system is theoretically analyzed.Compared with the conventional ground-source heat pump(GSHP),the DX GSHP has a lower condensing temperature in the cooling mode and a higher evaporating temperature in the heating mode,and the ground heat exchanger(GHE)in the DX GSHP has a low thermal resistance.Therefore,the coefficient of performance(COP)of the DX GSHP is higher than that of the GSHP.In addition,the system performance of the DX GSHP system is higher than that of the conventional GSHP system because there are no secondary solution loops and water circulating pumps in the DX GSHP system.The experimental energy performance of the DX GSHP system is also investigated based on the actual operational data.The tested DX GSHP system is installed in Xiangtan,China.The U-vertical GHE of the DX GSHP is buried in a water well.The length and the outside nominal diameter of the GHE are 42 m and 12.7 mm,respectively.The experimental results show that the maximum(COP)and the average COP of the DX GSHP system in the heating mode are 5.95 and 4.72,respectively.展开更多
In textile finishing, stenters always draw considerable attention to newer inventions to boost up production via maximum utilization of energy. Prior to main drying or heat-setting chambers, intermediate heating of cy...In textile finishing, stenters always draw considerable attention to newer inventions to boost up production via maximum utilization of energy. Prior to main drying or heat-setting chambers, intermediate heating of cylindrical system especially by steam has a direct blessing to moisture evaporation, processing speed, fabric quality and so on. Based on actual operational data, this study reveals the outcomes of a pre-heating module installed within a stenter. After employing the pre-heating system to knit fabrics of different structures and compositions, 23% - 61% moisture reduction was found and the speed of processing fabrics was increased simultaneously by 17% - 30% without any compromise on fabric quality. Moreover, no less than 8.21% savings in annual electricity consumption were observed.展开更多
The TiB+TiC dual-reinforced B_(4)C/TC4 composite was in-situ fabricated via incorporating 0.5wt%B_(4)C reinforcement during the laser melting deposition process.Different heat treatments of annealing and solid solutio...The TiB+TiC dual-reinforced B_(4)C/TC4 composite was in-situ fabricated via incorporating 0.5wt%B_(4)C reinforcement during the laser melting deposition process.Different heat treatments of annealing and solid solution were used to regulate the microstructure,mechanical properties,and corrosion properties of B_(4)C/TC4 composite.Results show that with the increase in temperature from 500℃to 800°C,partial lamellarα-Ti in the as-deposited sample is gradually transformed into equiaxedα-Ti,accompanied by the disappearance of basketweave microstructure.At 1100°C,a small portion of TiC phase suffers fusion.This composite exhibits the optimal combination of strength and plasticity after annealing at 500℃for 4 h followed by furnace cooling,which is attributed to the stress release effect and the refined basketweave microstructure.However,this composite shows a decline in corrosion resistance after various heat treatments due to grain coarsening and micro-galvanic corrosion.展开更多
To explore the distribution law of the temperature field in the motor pump and the influence of the fanshaped DC channel with spoiler in the pump housing on its heat dissipation performance.This study takes the arc-ge...To explore the distribution law of the temperature field in the motor pump and the influence of the fanshaped DC channel with spoiler in the pump housing on its heat dissipation performance.This study takes the arc-gear type hydraulicmotor pump as the research object.In COMSOL,a coupled heat transfer simulationmodel of themotor pump’s fluid-solid coupling is established,and the internal temperature field characteristics are analyzed.To improve the heat dissipation effect of the motor pump,it is proposed to arrange spoiler in the fan-shaped DC channel of the pump housing to enhance heat dissipation.Three types of spoilers,namely,wing-shaped,inclined rectangle-shaped,and wave-shaped,are designed.The simulation results show that when the motor pump operates under rated conditions,due to the poor heat dissipation environment inside the motor pump,the high-temperature areas of the motor pump are concentrated in the rotor and permanent magnet parts.After arranging the spoiler,the turbulent kinetic energy and vorticity in the fan-shaped DC channel of the pump housing are significantly enhanced.All three spoiler structures can reduce the maximum temperature of each component of the motor.According to the comprehensive performance evaluation criterion(PEC),the inclined rectangle-shaped structure has the best comprehensive heat transfer performance(PEC=1.114),while the wave-shaped structure has higher heat transfer efficiency but greater pressure loss.The wing-shaped structure has relatively limited enhancement effect on heat dissipation.This study systematically quantifies the influence of different spoiler structures on heat dissipation performance and flowresistance characteristics,providing a solution for enhancing the heat dissipation of the motor pump.展开更多
基金support by the Shanghai Engineering Research Center for Shallow Geothermal Energy(DRZX-202306)Shaanxi Coal Geology Group Co.,Ltd.(SMDZ-ZD2024-23)+4 种基金Key Laboratory of Coal Resources Exploration and Comprehensive Utilization,Ministry of Natural Resources,China(ZP2020-1)Shaanxi Investment Group Co.,Ltd.(SIGC2023-KY-05)Key Research and Development Projects of Shaanxi Province(2023-GHZD-54)Shaanxi Qinchuangyuan Scientist+Engineer Team Construction Project(2022KXJ-049)China Postdoctoral Science Foundation(2023M742802,2024T170721).
文摘Geothermal energy,a form of renewable energy,has been extensively utilized for building heating.However,there is a lack of detailed comparative studies on the use of shallow and medium-deep geothermal energy in building energy systems,which are essential for decision-making.Therefore,this paper presents a comparative study of the performance and economic analysis of shallow and medium-deep borehole heat exchanger heating systems.Based on the geological parameters of Xi’an,China and commonly used borehole heat exchanger structures,numerical simulationmethods are employed to analyze performance and economic efficiency.The results indicate that increasing the spacing between shallow borehole heat exchangers can effectively reduce thermal interference between the pipes and improve heat extraction performance.As the flow rate increases,the outlet water temperature ranges from 279.3 to 279.7 K,with heat extraction power varying between 595 and 609 W.For medium-deep borehole heat exchangers,performance predictions show that a higher flow rate results in greater heat extraction power.However,when the flow rate exceeds 30 m^(3)/h,further increases in flow rate have only a minor effect on enhancing heat extraction power.Additionally,the economic analysis reveals that the payback period for shallow geothermal heating systems ranges from 10 to 11 years,while for medium-deep geothermal heating systems,it varies more widely from 3 to 25 years.Therefore,the payback period for medium-deep geothermal heating systems is more significantly influenced by operational and installation parameters,and optimizing these parameters can considerably shorten the payback period.The results of this study are expected to provide valuable insights into the efficient and cost-effective utilization of geothermal energy for building heating.
基金supported by the Guangdong Basic and Applied Basic Research Foundation(No.2023B1515040013).
文摘The vigorous development of modern electronic communication demands multi-functional materials with exceptional electromagnetic interference(EMI)shielding.However,constructing lightweight and highly efficient metal-free carbon-based EMI shielding materials remains a huge challenge,particularly with robust EMI responses across a broadband frequency.Herein,a broadband(8-27 GHz)and strong EMI shielding response nitrogen-doped carbon plate(NCP)is constructed by a pressing and two-step pyroly-sis process.The layered stacking structure and N-doping impart extraordinary EMI shielding performance to the carbon plate,achieving EMI shielding effectiveness values of 82.60,95.44,and 104.12 dB in the X band,Ku band,and K band,respectively.Notably,the overall thickness of NCP was<1 mm.Moreover,the NCP exhibits remarkable joule heating performance with a low driving voltage(≤3 V)and a fast elec-trothermal response.This work enables the potential for the development of metal-free carbon materials with lightweight,highly efficient and broadband-strong EMI shielding performance.
文摘In order to enhance the off-peak performance of gas turbine combined cycle(GTCC)units,a novel collaborative power generation system(CPG)was proposed.During off-peak operation periods,the remaining power of the GTCC was used to drive the adiabatic compressed air energy storage(ACAES),while the intake air of the GTCC was heated by the compression heat of theACAES.Based on a 67.3MW GTCC,under specific demand load distribution,a CPG system and a benchmark system(BS)were designed,both of which used 9.388% of the GTCC output power to drive the ACAES.The performance of the CPG and the BS without intake air heating was compared.The results show that the load rate of the GTCC in the CPG system during off-peak periods is significantly enhanced,and the average operating efficiency of the GTCC is increased by 1.19 percentage points.However,in the BS system,due to the single collaborativemethod of load shifting,the GTCC operative efficiency is almost increased by 1.00 percentage points under different ambient temperatures.In a roundtrip cycle at an ambient temperature of 288.15K,the systemefficiency of the CPG reaches 0.5010,which is 0.62 percentage points higher than the operative efficiency of 0.4948 in the standalone GTCC;while the system efficiency of the BS is slightly inferior to that of the standalone GTCC.The findings confirm the technical feasibility and performance improvement of the ACAES-GTCC collaborative power generation system.
基金The National Natural Science Foundation of China(No.50676018)the National Key Technology R&D Program of China during the 11th Five-Year Plan Period(No.2008BAJ12B02)
文摘To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and performance of the heat pump part of this new heating system are studied.Based on a SASHP with 10 kW,the mathematical model of this system is built,and the characteristics and performance are concluded from the simulation analysis at different environmental temperatures and output water temperatures.The results show that the performance of heat pumps can be greatly improved based on the new SASHP.When the environmental temperature is 7 ℃,the coefficient of performance(COP)of the air-source heat pump(ASHP)can be increased by 26% at most.This paper sets up a base for further study on the heating system with this new SASHP in the heating season.
基金supported by the National Natural Science Foundation of China(Grant No.12272345).
文摘This study presents a simplified numerical approach for evaluating the thermal performance of louvered fin and flat tube heat exchangers(LFFTHXs),which are critical in many thermal management applications but difficult to model due to their complex geometries.The proposed method uses an equivalent convective heat transfer coefficient to represent the fins,significantly reducing the computational requirements of the simulations.Validation against the effectiveness-number of transfer units method showed average deviations of 4.4%for the novel louvered fin with two combined holes and 9.5%for conventional configurations,confirming the accuracy of the method.Further application to two-phase refrigerant scenarios using experimental data demonstrated the robustness of the method and its suitability for practical design and optimization of LFFTHXs.The approach not only improves the feasibility of thermal analysis in industrial applications but also provides a foundation for future research into more efficient heat exchanger designs.
基金funded by the Sichuan Natural Science Foundation,grant number 2023NSFSC0870.
文摘In this work,numerical simulations are performed to investigate the influence of combining ribs and triangular cavities on the thermal-hydraulic performance(THP)of MCHS at fluid velocities ranging from1 to 4 m/s(corresponding to Reynolds numbers(Re)of 129.75 to 519).Specifically,the ribs are positioned on the bottomwall,and the rib width is equal to the mini-channel width,while the triangular cavities are arranged on the two side walls of the MCHS.By analyzing and comparing key parameters such as velocity distribution,streamline patterns,pressure drop,skin friction coefficient(C_(f)),Nusselt number(Nu),friction factor(f),temperature fields,and performance evaluation criterion(PEC),the advantages of rib-cavity coupling configuration in enhancing THP are systematically discussed.Furthermore,the effects of cavity distribution(left,middle,and right),cavity depth(0.04,0.06,and 0.08 mm),and rib height(0.02,0.04,and 0.06 mm)on THP are analyzed to optimize the geometric parameters of the ribs and the cavities.The numerical simulation results indicate that,in comparison to the use of ribs or cavities alone,rib-cavity coupling can further improve the THP ofMCHS without causing a significant increase in pressure drop.The downstreamwall of the cavity is perpendicular to the flow direction which is more favorable for enhancing the heat transfer performance.Increasing the cavity depth improves the heat transfer performance ofMCHS,themaximumNu ratio increase by 35%at a rib height of 0.06 mm.However the increase in the rib height leads to a significant increase in the pressure drop,which in turn exerts a negative impact on THP,a maximumPEC of 1.198 is obtained at a rig height of 0.02 mm.The greatest improvement in THP,reaching 19.8%,is achieved when the cavity depth is 0.08 mm and the rib height is 0.02 mm.
基金funded by the Project of the Hubei Provincial Department of Science and Technology(Grant No.2022CFB957)the Project of Hubei Engineering University of Teaching Research(Grant No.JY2024032)+1 种基金Ministry of Education University-Industry Cooperation Collaborative Education Project(Grant No.220903584161245)College Students’Innovation and Entrepreneurship Training Program(Grant Nos.DC2024031,DC2024032).
文摘The behavior of single-phase flow and conjugate heat transfer in micro-channel heat sinks(MCHS)subjected to auniform heat flux is investigated by means of numerical simulations.Various geometrical configurations areexamined,particularly,the combinations of rectangular solid and perforated blocks,used to create a disturbancein the flow.The analysis focuses on several key aspects and related metrics,including the temperature distribution,the mean Fanning friction factor,the pressure drop,the Nusselt number,and the overall heat transfer coefficientacross a range of Reynolds numbers(80–870).It is shown that the introduction of such blocks significantlyenhances the heat transfer performances of the MCHS compared to the straight-through flow channel.Specifically,a case is found where the Nusselt number increases by 2.3 times relative to the reference case.The integrationof perforated blocks facilitates the generation of vorticity within the channel,promoting the mixing of coldand hot fluids.Notably,MCHS incorporating perforated rectangular blocks exhibit more pronounced heat transferbenefits at Reynolds numbers smaller than 400.
基金funded by the China National Administration of Coal Geology Science and Technology Innovation Project"Research on Clean Energy Exploration and Development Technology"(ZMKJ-2021-ZX04)the China National Administration of Coal Geology Special Task Project"Research on Geothermal Resource Exploration and Development Technology"(ZMKJ-2023-JBGS06)。
文摘The optimization of working fluids in single-well coaxial geothermal systems presents a critical pathway for advancing the use of enhanced geothermal systems(EGS)in renewable energy applications.This study evaluates the thermo-hydraulic performance of three working fluids(H_(2)O,CO_(2),and H_(2))in a single-well coaxial geothermal system,focusing on the effects of their injection temperatures.Using a 3D finite element model in COMSOL Multiphysics,simulations were conducted at three injection temperatures(17℃,27℃,40℃)under constant mass flow rates.The results reveal that hydrogen significantly outperforms water and carbon dioxide,achieving a 297.77% and 5453.76% higher thermal output,respectively.Notably,the heat transfer efficiency is significantly improved when the injected working fluids are at 40℃,compared to 27℃;this demonstrates a positive correlation between injection temperature and thermal recovery.Though water systems exhibit better geological compatibility,the superior thermal properties of hydrogen position it as a promising alternative-despite potential subsurface challenges.This study provides critical insights for advancing the application of high-efficiency geothermal systems as well as the development of non-aqueous working fluids,thus contributing to the sustainable utilization of geothermal energy.
文摘This study involved numerical simulations of a double tube heat exchanger using the ANSYS FLUENT programversion 22.The study aims to examine methods for minimizing pressure loss and consequently enhancing the thermal performance index(TPI)of a heat exchanger fitted with wavy edge tape that is a heat recovery system(the hot air in simulation instead of t heat from the exhaust gases of the brick factory furnaces and return it to warm the heavy fuel oil by substituting the electrical heater with a heat exchanger to recuperate waste heat from the flue gases,so elevating the temperature of Heavy fuel oil(HFO)to inject from the roof nozzles of combustion chamber of the furnace furthermore reducing cost(by finding the optimal design of wavy edge tape))and energy consumption.Air was selected as the hot gas in the inner pipe instead of furnace exhaust gases due to their similar thermal characteristics.A numerical analysis was conducted to create a novel wavy edge tape with varying widths(50%Di,75%Di,and 95%Di),lengths(1000,1200,1400)mm,amplitudes(5,10,15)mm,and periods of wavy length(5,10,15)mm.The flow rate of the outer pipe fluid(oil)ranges from(0.06 to 0.1)kg/s,while the velocity of the hot fluid(air)varies from(1 to 27)m/s,Re_(air)(6957 to 187,837).The entrance temperature of the hot fluid can be either(200,225,and 250)℃.The study finds that wavy edge tape tubes are more effective than smooth tubes in terms of oil outlet temperature;results revealed that an increase in the oil mass flow rate leads to a decrease in the oil outlet temperature and an increase in the heat transfer rate,at the air temperature 250℃.Additionally,the results indicate that increasing the width,length,and amplitude also leads to an increase in the oil outlet temperature of(94-94.12)℃,the pressure drop of(568.3)Pa,and the Nusselt number(65.7-66.5)respectively on the oil side.Finally,the heat exchanger’s best thermal performance index was found by investigating temperature contour at amplitude(A=5),period(p=15),width(w=75%Di),and length(L=1200 mm).The values for these parameters are,in order(1.02,1.025,1.02,and 1.0077).
基金the National Natural Science Foundation of China (No. 50872090)
文摘La3+ was selected to elevate the lattice electronic conductivity of LiFePO4,and LiFePO4/(C+La3+) cathode powders were synthesized by microwave heating using a domestic microwave oven for 35 min. The microstructures and morphologies of the synthesized materials were investigated by XRD and SEM. The electrochemical performances were evaluated by galvanostatic charge-discharge. The electrochemical performance of LiFePO4 with different La3+ contents was studied. Results indicated that the initial specific disch...
基金Project(hx2013-87)supported by the Qingdao Economic and Technology Development Zone Haier Water-Heater Co.Ltd.,China
文摘In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 ℃) and condenser water inlet temperature(30-50℃). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 ℃ to 17.8 ℃, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 ℃ to 50 ℃. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature.
基金Guangdong Province Key Laboratory of Efficient and Clean Energy Utilization(South China University of Technology)(2013A061401005)Research Fund(JMSWFW-2110-044)from Zhongshan Jiaming Electric Power Co.,Ltd.
文摘The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems.This paper investigated the coupling performance of a cogeneration heating and power system multidimensionally based on the operating characteristics of the cogeneration units,the hydraulic and thermodynamic characteristics of the heating network,and the energy loads.Taking a steam network supported by a gas-steam combined cycle cogeneration system as the research case,the interaction effect among the source-side prime movers,the heating networks,and the terminal demand thermal parameters were investigated based on the designed values,the plant testing data,and the validated simulation.The operating maps of the gas-steam combined cycle cogeneration units were obtained using THERMOFLEX,and the minimum source-side steam parameters of the steam network were solved using an inverse solution procedure based on the hydro-thermodynamic coupling model.The cogeneration operating maps indicate that the available operating domain considerably narrows with the rise of the extraction steam pressure and flow rate.The heating network inverse solution demonstrates that the source-side steam pressure and temperature can be optimized from the originally designed 1.11 MPa and 238.8°C to 1.074 MPa and 191.15°C,respectively.Under the operating strategy with the minimum source-side heating parameters,the power peak regulation depth remarkably increases to 18.30%whereas the comprehensive thermal efficiency decreases.The operation under the minimum source-side heating steam parameters can be superior to the originally designed one in the economy at a higher price of the heating steam.At a fuel price of$0.38/kg and the power to fuel price of 0.18 kg/(kW·h),the critical price ratio of heating steam to fuel is 119.1 kg/t.The influence of the power-fuel price ratio on the economic deviation appears relatively weak.
基金Project(2006BAJ03A06) supported by National Science and Technology Pillar Program During 11th Five-Year Plan
文摘A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.
基金The National Natural Science Foundation of China(No. 50976022)
文摘A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, compressed air, glycol water solution and water as the heating fluids, and air and water as the cooling fluids. The heat transfer performance testing of heat exchangers can be conducted not only for a conventional one heating fluid to one cooling fluid, but also for a compound air cooling heat exchanger with two or three heating fluids in parallel or in series. The control and measurement system is implemented based on a LabVIEW software platform, consisting of the data acquisition and process system, and the automotive operation and control system. By using advanced measuring instruments combined with sound computer software control, the testing system has characteristics of a compact structure, high accuracy, a wide range of testing scope and a friendly operation interface. The uncertainty of the total heat transfer coefficient K is less than 5%. The testing system provides a reliable performance testing platform for designing and developing new heat exchangers.
文摘The objective of the present experimental work is to investigate the performance of a wrapped screen heat pipe for atmospheric air heating to compare with the limits of this pipe. The experiment was conducted using copper pipe material and acetone as working fluid at different vapor temperatures. The testing also consists of a heater, a blower for heat removal (condenser), temperature measuring device, a vapor temperature probe, acetone charging system, and a vacuum pump. The copper outside diameterof the pipe is 0.022 m, with a total length of 0.6 m. The results showed that the pipe wall temperature (Tw) for a wrapped screen heat pipe has a rapid increase and takes 50 min to reach steady state at (Q = 63 W). The vapour temperature of working fluid increases as the heat load increases at constant air velocity. It was also been found that the range of vapour temperature deceases as the filling ratio increases that means the increasing of the filling ratio results the decrease of the maximum vapour temperature and the variation in the vapour temperature. The best recorded filling ratio is 0.6 which has the lowest vapour temperature at highest heat load. The maximum heat transport limit for this pipe is 80 W and the maximum temperature difference for air is 5。C.
基金The National Key Technologies R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2006BAJ04B04,2006BAJ04A05,2006BAJ04A13)
文摘The performance of a direct-expansion ground-source heat pump(DX GSHP)system is theoretically analyzed.Compared with the conventional ground-source heat pump(GSHP),the DX GSHP has a lower condensing temperature in the cooling mode and a higher evaporating temperature in the heating mode,and the ground heat exchanger(GHE)in the DX GSHP has a low thermal resistance.Therefore,the coefficient of performance(COP)of the DX GSHP is higher than that of the GSHP.In addition,the system performance of the DX GSHP system is higher than that of the conventional GSHP system because there are no secondary solution loops and water circulating pumps in the DX GSHP system.The experimental energy performance of the DX GSHP system is also investigated based on the actual operational data.The tested DX GSHP system is installed in Xiangtan,China.The U-vertical GHE of the DX GSHP is buried in a water well.The length and the outside nominal diameter of the GHE are 42 m and 12.7 mm,respectively.The experimental results show that the maximum(COP)and the average COP of the DX GSHP system in the heating mode are 5.95 and 4.72,respectively.
文摘In textile finishing, stenters always draw considerable attention to newer inventions to boost up production via maximum utilization of energy. Prior to main drying or heat-setting chambers, intermediate heating of cylindrical system especially by steam has a direct blessing to moisture evaporation, processing speed, fabric quality and so on. Based on actual operational data, this study reveals the outcomes of a pre-heating module installed within a stenter. After employing the pre-heating system to knit fabrics of different structures and compositions, 23% - 61% moisture reduction was found and the speed of processing fabrics was increased simultaneously by 17% - 30% without any compromise on fabric quality. Moreover, no less than 8.21% savings in annual electricity consumption were observed.
基金Tianjin Municipal Natural Science Foundation(23JCYBJC00040)National Natural Science Foundation of China(52175369)。
文摘The TiB+TiC dual-reinforced B_(4)C/TC4 composite was in-situ fabricated via incorporating 0.5wt%B_(4)C reinforcement during the laser melting deposition process.Different heat treatments of annealing and solid solution were used to regulate the microstructure,mechanical properties,and corrosion properties of B_(4)C/TC4 composite.Results show that with the increase in temperature from 500℃to 800°C,partial lamellarα-Ti in the as-deposited sample is gradually transformed into equiaxedα-Ti,accompanied by the disappearance of basketweave microstructure.At 1100°C,a small portion of TiC phase suffers fusion.This composite exhibits the optimal combination of strength and plasticity after annealing at 500℃for 4 h followed by furnace cooling,which is attributed to the stress release effect and the refined basketweave microstructure.However,this composite shows a decline in corrosion resistance after various heat treatments due to grain coarsening and micro-galvanic corrosion.
基金supported by the Henan Provincial Key Research and Development Special Project(251111220200)Natural Science Foundation of Henan Province Project(252300420446).
文摘To explore the distribution law of the temperature field in the motor pump and the influence of the fanshaped DC channel with spoiler in the pump housing on its heat dissipation performance.This study takes the arc-gear type hydraulicmotor pump as the research object.In COMSOL,a coupled heat transfer simulationmodel of themotor pump’s fluid-solid coupling is established,and the internal temperature field characteristics are analyzed.To improve the heat dissipation effect of the motor pump,it is proposed to arrange spoiler in the fan-shaped DC channel of the pump housing to enhance heat dissipation.Three types of spoilers,namely,wing-shaped,inclined rectangle-shaped,and wave-shaped,are designed.The simulation results show that when the motor pump operates under rated conditions,due to the poor heat dissipation environment inside the motor pump,the high-temperature areas of the motor pump are concentrated in the rotor and permanent magnet parts.After arranging the spoiler,the turbulent kinetic energy and vorticity in the fan-shaped DC channel of the pump housing are significantly enhanced.All three spoiler structures can reduce the maximum temperature of each component of the motor.According to the comprehensive performance evaluation criterion(PEC),the inclined rectangle-shaped structure has the best comprehensive heat transfer performance(PEC=1.114),while the wave-shaped structure has higher heat transfer efficiency but greater pressure loss.The wing-shaped structure has relatively limited enhancement effect on heat dissipation.This study systematically quantifies the influence of different spoiler structures on heat dissipation performance and flowresistance characteristics,providing a solution for enhancing the heat dissipation of the motor pump.