期刊文献+
共找到10,395篇文章
< 1 2 250 >
每页显示 20 50 100
Smart Society and Artificial Intelligence:Big Data Scheduling and the Global Standard Method Applied to Smart Maintenance 被引量:2
1
作者 Ruben Foresti Stefano Rossi +2 位作者 Matteo Magnani Corrado Guarino Lo Bianco Nicola Delmonte 《Engineering》 SCIE EI 2020年第7期835-846,共12页
The implementation of artificial intelligence(AI)in a smart society,in which the analysis of human habits is mandatory,requires automated data scheduling and analysis using smart applications,a smart infrastructure,sm... The implementation of artificial intelligence(AI)in a smart society,in which the analysis of human habits is mandatory,requires automated data scheduling and analysis using smart applications,a smart infrastructure,smart systems,and a smart network.In this context,which is characterized by a large gap between training and operative processes,a dedicated method is required to manage and extract the massive amount of data and the related information mining.The method presented in this work aims to reduce this gap with near-zero-failure advanced diagnostics(AD)for smart management,which is exploitable in any context of Society 5.0,thus reducing the risk factors at all management levels and ensuring quality and sustainability.We have also developed innovative applications for a humancentered management system to support scheduling in the maintenance of operative processes,for reducing training costs,for improving production yield,and for creating a human–machine cyberspace for smart infrastructure design.The results obtained in 12 international companies demonstrate a possible global standardization of operative processes,leading to the design of a near-zero-failure intelligent system that is able to learn and upgrade itself.Our new method provides guidance for selecting the new generation of intelligent manufacturing and smart systems in order to optimize human–machine interactions,with the related smart maintenance and education. 展开更多
关键词 Smart maintenance Smart society Artificial intelligence Human-centered management system Big data scheduling Global standard method Society 5.0 Industry 4.0
在线阅读 下载PDF
Quantitative Determination of Tetrachlorantraniliprole by(1)^H NMR Spectroscopy with Internal Standard Method
2
作者 Lang Jie Dong Yan +2 位作者 Wang Qiang Yang Huibin Yu Haibo 《Plant Diseases and Pests》 CAS 2020年第5期35-37,共3页
[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solven... [Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solvent and maleic acid as internal standard under the conditions of temperature 25℃,pulses width 8.0μs,delay time 5 s,and scanning times 8.[Result]The hydrogen proton peaks of tetrachlorantraniliprole(δ=10.55)and maleic acid(δ=6.27)were taken as quantitative peaks.The peak area ratio y(As/Ar)and mass ratio x(ms/mr)were linearly regressed,and the correlation coefficient was 0.9999.The RSD value of repeatability test was 0.38%,and the RSD value of stability test was 0.77%.The content of tetrachlorantraniliprole was determined as 99.6%.[Conclusion]1H NMR spectroscopy can be used for quantitative determination of tetrachlorantraniliprole without standard reference,which is rapid,accurate and simple. 展开更多
关键词 Tetrachlorantraniliprole qNMR Internal standard method Quantitative determination
在线阅读 下载PDF
Application of internal standard method in recombinant luminescent bacteria test
3
作者 Yong-zhi Wang Dan Li Miao He 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2015年第9期128-134,共7页
Mercury and its organic compounds have been of severe concern worldwide due to their damage to the ecosystem and human health. The development of effective and affordable technology to monitor and signal the presence ... Mercury and its organic compounds have been of severe concern worldwide due to their damage to the ecosystem and human health. The development of effective and affordable technology to monitor and signal the presence of bioavailable mercury is an urgent need.The Mer gene is a mercury-responsive resistant gene, and a mercury-sensing recombinant luminescent bacterium using the Mer gene was constructed in this study. The mer operon from marine Pseudomonas putida strain SP1 was amplified and fused with prompterless lux CDABE in the p UCD615 plasmid within Escherichia coli cells, resulting in p THE30–E. coli.The recombinant strain showed high sensitivity and specificity. The detection limit of Hg^2+was 5 nmol/L, and distinct luminescence could be detected in 30 min. Cd^2+, Cu^2+, Zn^2+, Ca^2+,Pb^2+, Mg^2+, Mn^2+, and Al^3+did not interfere with the detection over a range of 10-5–1 m M.Application of recombinant luminescent bacteria testing in environmental samples has been a controversial issue: especially for metal-sensing recombinant strains, false negatives caused by high cytotoxicity are one of the most important issues when applying recombinant luminescent bacteria in biomonitoring of heavy metals. In this study, by establishing an internal standard approach, the false negative problem was overcome;furthermore, the method can also help to estimate the suspected mercury concentration,which ensures high detection sensitivity of bioavailable Hg2+. 展开更多
关键词 Mercury Biomonitoring Recombinant luminescent bacteria p THE30–E.coli Internal standard method False negative
原文传递
Synthesis of an IS and Steviol Glycoside Analysis by a Validated Internal Standard Method
4
作者 Jan M. C. Geuns Tom Struyf +2 位作者 Stijn Ceunen Gert Steurs Wim De Borggraeve 《American Journal of Analytical Chemistry》 2018年第11期547-559,共13页
The internal standard (IS) method is the best method for the analysis of samples, as it is independent of errors in injection volume, changes in sample volumes, and changes in sensitivity of the detector, etc. Use of ... The internal standard (IS) method is the best method for the analysis of samples, as it is independent of errors in injection volume, changes in sample volumes, and changes in sensitivity of the detector, etc. Use of an internal standard allows for the correction of losses due to sample clean-up of complex samples. An ideal IS is a compound that has properties very similar to, and that behaves as the compounds to be analysed. Ideally, only in the last step of analysis (HPLC), the IS should be well separated from the compounds of the mixture to be analysed. After testing several existing compounds with negative results, we decided to synthesise the 19-O-β-D-galactopyranosyl-13-O-β-D-glucopyranosyl-steviol as IS. This is the 19-galactosyl ester of steviolmonoside (13-O-β-D-glucopyranosyl-steviol). The IS was made according to published methods. Steviolmonoside (SM) was made from purified commercial rubusoside (Rub) by refluxing it in 10% KOH for 2 h. SM was precipitated and crystallized from MeOH. The hydroxyls of the glucose unit of SM were protected by acetylation. The acetylated SM was crystallized from acetone and dissolved in 1,2-dichloroethane. Then Ag2CO3 on Celite and tetra-acetylated galactopyranosyl bromide were added and the mixture was refluxed for 2 h. After cooling, BaO in MeOH was added to remove the acetyl groups. The 1,2-dichloroethane fraction was then extracted three times with equal volumes of water and the water fraction containing the IS was further purified on a C18 flash chromatography column. Traces of unreacted SM were removed by preparative HPLC on an Alltima C18 column (250 mm × 22 mm, particle size 10 μm) with AcCN:water (35:65, 20 ml/min). Detection was at 210 nm (KNAUER, “Smartline” UV detector 2500). The collected IS fraction from the HPLC was completely dried. Mixtures of steviol glycosides (SVglys) containing IS could be purified over SPE cartridges without change of the SVgly over IS ratio. The calibration curves for rebaudioside A (RebA) and stevioside (ST) were linear between 0.012 and 0.95 and between 0.013 and 1.13 mM for RebA and ST, respectively. The accuracy was checked by the standard addition method. It was concluded that the IS method gives an excellent precision and accuracy. 展开更多
关键词 STEVIOL GLYCOSIDES INTERNAL standard method VALIDATION Quantification PURIFICATION
暂未订购
Optimal Scheduling of an Independent Electro-Hydrogen System with Hybrid Energy Storage Using a Multi-Objective Standardization Fusion Method
5
作者 Suliang Ma Zeqing Meng +1 位作者 Mingxuan Chen Yuan Jiang 《Energy Engineering》 EI 2025年第1期63-84,共22页
In the independent electro-hydrogen system(IEHS)with hybrid energy storage(HESS),achieving optimal scheduling is crucial.Still,it presents a challenge due to the significant deviations in values ofmultiple optimizatio... In the independent electro-hydrogen system(IEHS)with hybrid energy storage(HESS),achieving optimal scheduling is crucial.Still,it presents a challenge due to the significant deviations in values ofmultiple optimization objective functions caused by their physical dimensions.These deviations seriously affect the scheduling process.A novel standardization fusion method has been established to address this issue by analyzing the variation process of each objective function’s values.The optimal scheduling results of IEHS with HESS indicate that the economy and overall energy loss can be improved 2–3 times under different optimization methods.The proposed method better balances all optimization objective functions and reduces the impact of their dimensionality.When the cost of BESS decreases by approximately 30%,its participation deepens by about 1 time.Moreover,if the price of the electrolyzer is less than 15¥/kWh or if the cost of the fuel cell drops below 4¥/kWh,their participation will increase substantially.This study aims to provide a more reasonable approach to solving multi-objective optimization problems. 展开更多
关键词 Electro-hydrogen system multi-objective optimization standardization method hybrid energy storage system
在线阅读 下载PDF
Price composition analysis of blood glucose meters and blood glucose test strips in Hubei Province based on the World Health Organization/Health Action International standard survey method
6
作者 Jianing Zheng Yushu Liu +2 位作者 Xi Wang Hongye Li Chenxi Liu 《Journal of Chinese Pharmaceutical Sciences》 2025年第10期954-966,共13页
The purpose of this study is to evaluate the price and composition of blood glucose meters and blood glucose test papers in Hubei Province,so as to improve the affordability of blood glucose monitoring for diabetes pa... The purpose of this study is to evaluate the price and composition of blood glucose meters and blood glucose test papers in Hubei Province,so as to improve the affordability of blood glucose monitoring for diabetes patients.Using the standard survey method jointly developed by the World Health Organization(WHO)and Health Action International(HAI)for drug price composition analysis,central level data was collected through literature review,policy review,and interviews with key informants.Field research was conducted in Wuhan and Yichang to trace price data at various levels of the supply chain.At the central level,data shows that China has implemented multiple policies related to the management and pricing of blood glucose meters and test strips,but has not yet introduced price restrictions for blood glucose meters and test strips;At the supply chain level,data shows that the price composition of blood glucose meters and test strips in Hubei Province is mainly composed of manufacturer prices and retail markups,followed by supply chain taxes and wholesale markups.It can be seen from this that China has established a comprehensive medical device registration,sales,quality control and management standard system through a series of policies.At present,China has not issued price policies for blood glucose meters and blood glucose test papers.Therefore,we can reduce product prices by including medical insurance,government subsidies,competitive bidding,and reducing supply chain taxes,thus improving the affordability of blood glucose monitoring for diabetes patients. 展开更多
关键词 WHO/HAI standard survey method Hubei province Blood glucose meters Blood glucose test strips Price composition
原文传递
Improved EEMD-based standardization method for developing long tree-ring chronologies 被引量:6
7
作者 Xianliang Zhang Junxia Li +1 位作者 Xiaobo Liu Zhenju Chen 《Journal of Forestry Research》 SCIE CAS CSCD 2020年第6期2217-2224,共8页
Long tree-ring chronologies can be developed by overlapping data from living trees with data from fossil trees through cross-dating.However,low-frequency climate signals are lost when standardizing tree-ring series du... Long tree-ring chronologies can be developed by overlapping data from living trees with data from fossil trees through cross-dating.However,low-frequency climate signals are lost when standardizing tree-ring series due to the"segment length curse".To alleviate the segment length curse and thus improve the standardization method for developing long tree-ring chronologies,here we first calculated a mean value for all the tree ring series by overlapping all of the tree ring series.The growth trend of the mean tree ring width(i.e.,cumulated average growth trend of all the series)was determined using ensemble empirical mode decomposition.Then the chronology was developed by dividing the mean value by the growth trend of the mean value.Our improved method alleviated the problem of trend distortion.Long-term signals were better preserved using the improved method than in previous detrending methods.The chronologies developed using the improved method were better correlated with climate than those developed using conservative methods.The improved standardization method alleviates trend distortion and retains more of the low-frequency climate signals. 展开更多
关键词 standardization methods Tree rings Segment length curse DETRENDING
在线阅读 下载PDF
Using Different Standardized Methods for Species Identification:A Case Study Using Beaks from Three Ommastrephid Species 被引量:4
8
作者 HU Guanyu FANG Zhou +3 位作者 LIU Bilin CHEN Xinjun STAPLES Kevin CHEN Yong 《Journal of Ocean University of China》 SCIE CAS CSCD 2018年第2期355-362,共8页
The cephalopod beak is a vital hard structure with a stable configuration and has been widely used for the identification of cephalopod species. This study was conducted to determine the best standardization method fo... The cephalopod beak is a vital hard structure with a stable configuration and has been widely used for the identification of cephalopod species. This study was conducted to determine the best standardization method for identifying different species by measuring 12 morphological variables of the beaks of Illex argentinus, Ommastrephes bartramii, and Dosidicus gigas that were collected by Chinese jigging vessels. To remove the effects of size, these morphometric variables were standardized using three methods. The average ratios of the upper beak morphological variables and upper crest length of O. bartramii and D. gigas were found to be greater than those of I. argentinus. However, for lower beaks, only the average of LRL(lower rostrum length)/LCL(lower crest length), LRW(lower rostrum width)/LCL, and LLWL(lower lateral wall length)/LCL of O. bartramii and D. gigas were greater than those of I. argentinus. The ratios of beak morphological variables and crest length were found to be all significantly different among the three species(P < 0.001). Among the three standardization methods, the correct classification rate of stepwise discriminant analysis(SDA) was the highest using the ratios of beak morphological variables and crest length. Compared with hood length, the correct classification rate was slightly higher when using beak variables standardized by crest length using an allometric model. The correct classification rate of the lower beak was also found to be greater than that of the upper beak. This study indicates that the ratios of beak morphological variables to crest length could be used for interspecies and intraspecies identification. Meanwhile, the lower beak variables were found to be more effective than upper beak variables in classifying beaks found in the stomachs of predators. 展开更多
关键词 BEAK standardized methodS DISCRIMINANT analysis Illex argentinus Ommastrephes bartramii Dosidicus GIGAS
在线阅读 下载PDF
Design Method of Equipment Optimization Development Based on Standardization Theory 被引量:2
9
作者 Lv-bo MAI 《Defence Technology(防务技术)》 SCIE EI CAS 2013年第3期140-145,共6页
The matters of equipment optimization development are usually discrete,fuzzy and non-quantitative.It is difficult directly to optimize the equipment development with a mathematical model.A set of methods for designing... The matters of equipment optimization development are usually discrete,fuzzy and non-quantitative.It is difficult directly to optimize the equipment development with a mathematical model.A set of methods for designing the equipment optimization development with six dimensions and eight main elements is established based on the theory and method of standardization.The top-tier design space of systematic development of equipment is built up by the relations of basic models,series and model spectrums.The relations of time and space for equipment optimization development are established.The design processes of a six dimension systematic space are expounded.The connotation of each plan in the main system space is analyzed.A design method for an entire equipment is established with standardization theory.The coordinating design methods of equipment technical system and the optimization design methods of equipment integration are discussed.The design methods for universalization and serialization of components and parts are established.The design methods of equipment optimization development highlight the relations of the basic model of platform,the serialization of platform basic models,the modularization of equipment functions,the model spectrum of variant equipment,and the universalization and serialization of components and parts. 展开更多
关键词 优化设计方法 优化开发 化设备 标准化 优化发展 数学模型 设计空间 设备系统
在线阅读 下载PDF
The Research on Methodology for Material Code Standardization in the Implementation of MRP-Ⅱ
10
作者 孙虞 《Journal of Southeast University(English Edition)》 EI CAS 1996年第2期13-18,共6页
This paper analyses the current common problems of material code standardization in the implementation of MRP Ⅱ, and puts forward the basic ideas and methods for solving the problems, which has some reference value ... This paper analyses the current common problems of material code standardization in the implementation of MRP Ⅱ, and puts forward the basic ideas and methods for solving the problems, which has some reference value for the popularization of application o 展开更多
关键词 CODING standard methods
在线阅读 下载PDF
LA-ICP-MS Calibrations for Intact Rock Samples with Internal Standard and Modified Constant-Sum Methods
11
作者 Sheng Peng Qinhong Hu 《American Journal of Analytical Chemistry》 2012年第2期168-174,共7页
Laser ablation coupled with inductively coupled plasma-mass spectrometry (LA-ICP-MS) calibration was conducted with multiple spot analyses on eleven intact rock samples using both an internal standard (IS) method and ... Laser ablation coupled with inductively coupled plasma-mass spectrometry (LA-ICP-MS) calibration was conducted with multiple spot analyses on eleven intact rock samples using both an internal standard (IS) method and a modified constant-sum (MCS) method. Methods were then compared for reported bulk elemental composition of the rocks. The MCS method was based on the sum of eight major elements, which is spatially more stable than one single major ele-ment as used in the IS method, and is quite constant among different rock samples. Calibrations were performed with standard reference materials NIST SRM 610, 612, 614, and 616. Little difference was found between using a single standard and a set of standards, because of the good linearity shown by the reference materials. Comparison of the two calibration methods shows that the MCS method produced better and more stable results than the IS method for heterogeneous samples. With the MCS method, approximately 94% to 95% of the total measurements are within the range of ±100% relative deviation, compared with 82% to 86% with the IS method. The IS method resulted insubstantial overestimations for some rock samples (e.g., 648% for Basalt BCR-2 using NIST SRM 610 as the calibration standard), while the largest deviation with the MCS method was 216% for U in Eagle Ford shale #80 sample. For Quartz latite QLO-1, a relative homogeneous sample, the IS method generated slightly better results than the MCS method. Regardless of method, spatially heterogeneous distribution of elements in the intact rock at the scale of the laser spot is considered to be the main reason for the large relative deviations seen in our work compared to published results. 展开更多
关键词 LA-ICP-MS Quantitative Calibration Internal standard method MODIFIED Constant-Sum method
暂未订购
Simultaneous Determination of Uranium and Thorium with Standard Dual-addition Method
12
作者 何荣桓 王建华 王玉宝 《Rare Metals》 SCIE EI CAS CSCD 1998年第2期75-80,共6页
dual-standard addition method was proposed and the principle of simultaneous determination for a interfering binary mixtures was discussed. The proposed procedure was applied to spectroscopic analyses for the simultan... dual-standard addition method was proposed and the principle of simultaneous determination for a interfering binary mixtures was discussed. The proposed procedure was applied to spectroscopic analyses for the simultaneous determination of uranium and thorium without prior separation. Various molar ratios of uranium/thorium, from 0.5∶1 to 10∶1, can be determined with satisfactory precision and accuracy. Uranium and thorium content in a phosphate ore and simulated sample were determined, the recoveries were 98.4%~102.5% for uranium and 96.8%~102.3% for thorium, the relative standard deviations (R.S.D) were 1.5%~2.3% for uranium and 2.1%~3.1% for thorium. 展开更多
关键词 Dual-standard addition method Simultaneous determination URANIUM THORIUM Spectroscopic analysis
在线阅读 下载PDF
The Measurement and Uncertainty Analysis of Antenna Factor of Microwave Antennas Based on Standard Site Method
13
作者 Chaochan Chen Hong Shi +1 位作者 Yi Miao Yu Sang 《International Journal of Communications, Network and System Sciences》 2017年第5期138-145,共8页
A method of Standard Site Method (SSM) in the American National Standards Institute’s ANSI C63.5 is described in the frequency ranges from 30 MHz to 1000 MHz. And a measurement system is set up for determining antenn... A method of Standard Site Method (SSM) in the American National Standards Institute’s ANSI C63.5 is described in the frequency ranges from 30 MHz to 1000 MHz. And a measurement system is set up for determining antenna factors (AF) of antennas on an Open Area Test Sites (OATS). AF of antennas including log-periodic antenna and biconical antenna is measured with SSM method by Shanghai Institute of Measurement and Testing Technology (SIMT), which shows good agreement to data measured by National Institute of Metrology (NIM). In the end, it analyzes the measurement uncertainty of SIMT in the 30 MHz to 1000 MHz frequency band and does comparison to that of NIM. 展开更多
关键词 ANTENNA FACTORS standard SITE method (SSM) MEASUREMENT UNCERTAINTY
暂未订购
Evaluation of Application Value of Improved Standard Collection Method in Sputum Bacterial Test
14
作者 MI Xiaomei YANG Wenjun 《外文科技期刊数据库(文摘版)医药卫生》 2021年第12期104-106,共5页
Objective: to study the effect of improved standard collection method in sputum bacterial test. Methods: 82 patients with acute attack of bronchitis received in our hospital from October 2018 to October 2019 were sele... Objective: to study the effect of improved standard collection method in sputum bacterial test. Methods: 82 patients with acute attack of bronchitis received in our hospital from October 2018 to October 2019 were selected for sputum bacterial test.Based on the order of admission, 41 cases in the reference group were given routine expectoration collection method;41 cases in the observation group were treated with improved standard collection method, and the test results of the two groups were compared. Results: ① The qualified rate of sputum samples in the observation group was statistically different from that in the reference group (P < 0.05).② The positive rate of sputum culture in the observation group was significantly different from that in the reference group (P < 0.05).③ There were differences in the collection time of samples and the operation time of sputum bacteriological test between the two groups (P < 0.05).Conclusion: the application of improved standard collection method in sputum bacterial test can improve the positive rate and shorten the time of practical operation. 展开更多
关键词 improved standard acquisition method sputum bacterial test application value
暂未订购
Compilation Principles and Methods of China’s First Mongolian Standard in Meteorological Industry
15
作者 Ying Chun Yu Gang Han Yanli 《Meteorological and Environmental Research》 CAS 2019年第4期118-121,共4页
Mongolian Terms Commonly Used in Meteorological Services that was issued by the China Meteorological Administration is China s first traditional Mongolian standard in meteorological industry. In the process of formula... Mongolian Terms Commonly Used in Meteorological Services that was issued by the China Meteorological Administration is China s first traditional Mongolian standard in meteorological industry. In the process of formulation, the compilation unit fully complied with the principles of scientificity, practicability, universality and versatility, and used literal translation, free translation, and the combination of literal translation and free translation to translate and compile 71 mongolian terms commonly used in meteorological services. The standard fills the blank of standardization construction of basic traditional Mongolian language in the meteorological industry of China. 展开更多
关键词 METEOROLOGY MONGOLIAN language standard COMPILATION PRINCIPLES and methodS
在线阅读 下载PDF
Analytical and Traveling Wave Solutions to the Fifth Order Standard Sawada-Kotera Equation via the Generalized exp(-Φ(ξ))-Expansion Method 被引量:1
16
作者 M. Y. Ali M. G. Hafez +1 位作者 M. K. H. Chowdury M. T. Akter 《Journal of Applied Mathematics and Physics》 2016年第2期262-271,共10页
In this article, we propose a generalized exp(-Φ(ξ))-expansion method and successfully implement it to find exact traveling wave solutions to the fifth order standard Sawada-Kotera (SK) equation. The exact traveling... In this article, we propose a generalized exp(-Φ(ξ))-expansion method and successfully implement it to find exact traveling wave solutions to the fifth order standard Sawada-Kotera (SK) equation. The exact traveling wave solutions are established in the form of trigonometric, hyperbolic, exponential and rational functions with some free parameters. It is shown that this method is standard, effective and easily applicable mathematical tool for solving nonlinear partial differential equations arises in the field of mathematical physics and engineering. 展开更多
关键词 Generalized exp(-Φ(ξ))-Expansion method Fifth Order standard Sawada-Kotera Equation SOLITONS Periodic Wave Solutions
在线阅读 下载PDF
ASHRAE Standard 170-2013简介 被引量:7
17
作者 沈晋明 保罗.尼诺穆拉 刘燕敏 《暖通空调》 北大核心 2014年第10期1-7,49,共8页
介绍了该标准修订的主要内容,包括:手术分类、湿度控制下限、病房通风要求、通风空调系统、能量回收、空气过滤要求。手术室分类由三类调整为两类。治疗室设计相对湿度的下限降至20%。病房最低换气次数要求由6h-1改为4h-1。调整了关于... 介绍了该标准修订的主要内容,包括:手术分类、湿度控制下限、病房通风要求、通风空调系统、能量回收、空气过滤要求。手术室分类由三类调整为两类。治疗室设计相对湿度的下限降至20%。病房最低换气次数要求由6h-1改为4h-1。调整了关于管道回风、多区域空调新风量计算、室内循环机组使用、风管衬里方面的规定。明确了医疗护理设施系统的能量回收利用及空气过滤的具体要求。 展开更多
关键词 医疗护理设施 通风 标准 措施 环境与感染控制 修订 背景 ASHRAE标准
在线阅读 下载PDF
基于AHP-模糊综合模型的高标准农田气象保障工程质量评价
18
作者 崔童 姬兴杰 +1 位作者 房勇 纪潇潇 《中国农业气象》 2026年第1期20-33,共14页
以高标准农田气象保障工程质量为研究对象,利用德尔菲法识别工程质量影响因素,建立工程质量综合评价指标体系,应用层次分析法求解各指标权重,基于模糊综合评价法构建适用于高标准农田气象保障工程质量的定量化评价模型,评估工程质量的... 以高标准农田气象保障工程质量为研究对象,利用德尔菲法识别工程质量影响因素,建立工程质量综合评价指标体系,应用层次分析法求解各指标权重,基于模糊综合评价法构建适用于高标准农田气象保障工程质量的定量化评价模型,评估工程质量的综合及单项指标等级、得分,指出工程建设质量的优势和短板,为工程质量评价、规划和升级提供参考。结果表明:高标准农田气象保障工程质量评价指标涵盖观测站网工程建设质量、预报预警系统建设质量、信息发布系统建设质量、防灾减灾工程建设质量、气象保障效益评估5个一级指标、8个二级指标和25个三级指标。5个一级指标的权重排序由高到低依次为观测站网(0.261)>预报预警(0.251)>防灾减灾(0.228)>信息发布(0.154)>效益评估(0.106),其中,观测站网、预报预警和防灾减灾3项一级指标的权重占比74%,是工程质量评价的关键性指标。信息发布和效益评估2项一级指标权重虽只占26%,但在为农气象服务链条中起前后衔接重要作用;二级指标中,同属1个一级指标下的3对二级指标两两间权重相差较小;三级指标中,灌溉与排水工程质量、灾情预报预警准确率、观测数据及时性指标是权重最高的前3项。以河南省郸城县的某高标准农田气象保障工程为案例,工程质量综合评分为86.3分,属良好等级。其中,5个一级指标均为良好,但各三级指标的评价结果存在差异,在观测站网工程建设、气象信息发布系统、防灾减灾基础设施和能力建设方面效用较好,但预报预警准确率和为农服务满意度等方面存在薄弱点。案例应用结果验证了综合评价模型的有效性和适用性,也为工程质量评价和管理提供了依据。 展开更多
关键词 高标准农田 气象保障工程 模糊综合评价法 工程质量 评价指标
在线阅读 下载PDF
Windows Mobile Standard中文输入法设计实现
19
作者 朱晓旭 钱培德 《计算机工程与应用》 CSCD 北大核心 2010年第5期63-65,共3页
Windows Mobile Standard是主流的手机操作系统之一,但其中的汉字输入法少,用户选择余地小。首先比较了Windows Mobile Standard中文输入法与桌面Windows中文输入法的异同,分析了Windows Mobile Standard的输入接口,然后讲解了设计并实... Windows Mobile Standard是主流的手机操作系统之一,但其中的汉字输入法少,用户选择余地小。首先比较了Windows Mobile Standard中文输入法与桌面Windows中文输入法的异同,分析了Windows Mobile Standard的输入接口,然后讲解了设计并实现一个Windows Mobile Standard纵横码中文输入法的过程,描述了其中的一些关键问题。纵横码汉字输入法的开发对于各种输入法向手持设备上移植具有借鉴意义。 展开更多
关键词 智能手机 Windows MOBILE standard 中文输入法 码本
在线阅读 下载PDF
Application and Development Trends of Spectral Analysis in Draft of Non-Ferrous Metal Standards in China
20
作者 Lijun Kuai Huachang Li +1 位作者 Jiemin Liu Shufang Tang 《American Journal of Analytical Chemistry》 2023年第6期239-273,共35页
Spectral analysis was a method of identifying substances, determining their chemical composition and calculating their content based on their spectral characteristics. This paper mainly discussed the application of va... Spectral analysis was a method of identifying substances, determining their chemical composition and calculating their content based on their spectral characteristics. This paper mainly discussed the application of various spectroscopic techniques, mainly including atomic absorption spectrometry (AAS) inductively coupled plasma emission spectrometry (ICP-AES) X-ray fluorescence spectroscopy (XRF) atomic fluorescence spectroscopy (AFS) direct reading spectroscopy (OES) glow discharge emission spectroscopy (GD-OSE) laser-induced breakdown spectroscopy (LIBS), in the formulation of non-ferrous metal standards in China. The AAS method was the most widely used single-element microanalysis method among the non-ferrous metal standards. The ICP-AES method was good at significant advantages in the simultaneous detection of multiple elements. The XRF method was increasingly used in the determination of primary and secondary trace elements due to its simple sample preparation and high efficiency. The AFS was mostly detected by single-element trace analysis. OES GD-OES and LIBS were playing an increasingly important role in the new demand area for non-ferrous metals. This paper discussed matrix elimination, sample digestion, sample preparation, instrument categories and other aspects of some standards, and summarized the advantages of spectral analysis and traditional chemical analysis methods. The new methods of future spectroscopic technology had been illustrated in the process of developing non-ferrous metal standards. 展开更多
关键词 Atomic Absorption Spectroscopy Inductively Coupled Plasma Emission Spectroscopy X-Ray Fluorescence Spectroscopy Atomic Fluorescence Spectroscopy Direct Reading Spectroscopy Glow Discharge Emission Spectroscopy Laser-Induced Breakdown Spectroscopy Non-Ferrous Metals standard methods Were Formulated
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部