In recent years,terbium radioisotopes have been investigated for their potential therapeutic and diagnostic applications in nuclear medicine.This study aimed to investigate the production of ^(152) Tb and ^(155) Tb by...In recent years,terbium radioisotopes have been investigated for their potential therapeutic and diagnostic applications in nuclear medicine.This study aimed to investigate the production of ^(152) Tb and ^(155) Tb by alpha-induced reactions in detail,with a specific focus on determining the optimum production parameters and testing existing nuclear models.Given the limited number of experiments conducted on reactions related to terbium isotope production,it is necessary to perform theoretical calculations of cross sections over a wide energy range to gain a detailed understanding of terbium isotope production.To achieve this objective,the cross sections of the ^(151)Eu(α,n)^(154) Tb reactions were calculated up to 60 MeV using the TALYS computer code with 432 different combinations of optical model parameters,level density,and strength function models.The theoretical reaction cross-section results were compared with the experimental results in the literature.The best input parameters were determined using the Threshold Logic Unit method,and these parameters were used in all isotope production calculations.Once the optimal model combination was determined,the total activity production and isotopic fraction of ^(152) Tb and ^(155) Tb isotopes were calculated in detail for beam energies of 17–50 MeV,different irradiation times,and varying ^(151) Eu and ^(153) Eu target thicknesses.展开更多
We present a prototype for hybrid Compton and positron emission tomography(PET)imaging aimed at enhancing data utilization and enabling concurrent imaging of multiple radiopharmaceuticals.The prototype comprises two d...We present a prototype for hybrid Compton and positron emission tomography(PET)imaging aimed at enhancing data utilization and enabling concurrent imaging of multiple radiopharmaceuticals.The prototype comprises two detectors that utilize LYSO-SiPM and were available in our laboratory.One detector consists of a 50×50 array of LYSO crystals,each measuring 0.9mm×0.9mm×10mm with 1 mm pitches,whereas the other detector comprises a 25×25 array of LYSO crystals,each measuring 1.9mm×1.9mm×10mm with 2 mm pitches.These detectors are mounted on a rotational stage,which enables them to function as either a Compton camera or a PET detector pair.The 64-channel signals from the SiPMs of each detector are processed through a capacitive multiplexing circuit to yield four position-weighted outputs.Distinct energy windows were used to discriminate Compton events from PET events.Energy resolution and energy-channel relationships were calibrated via multiple sources.The measured average energy resolutions(full widths at half maximum,FWHMs)for the detectors at 511 keV were 17.5%and 15.2%,respectively.The initial experimental results indicate an angular resolution(FWHM)of 8.6◦for the system in Compton imaging mode.A V-shaped tube injected with 18 F solution was clearly reconstructed,which further verified the imaging capabilities of the system in Compton imaging mode.The results of simulation and experimental imaging studies show that the system can detect tumors as small as 1 mm in diameter when working in PET imaging mode.Mouse bone PET imaging was successfully conducted,with the results matching well with the corresponding CT images.This technology holds great potential for advancing the development of physiological function modalities.展开更多
文摘In recent years,terbium radioisotopes have been investigated for their potential therapeutic and diagnostic applications in nuclear medicine.This study aimed to investigate the production of ^(152) Tb and ^(155) Tb by alpha-induced reactions in detail,with a specific focus on determining the optimum production parameters and testing existing nuclear models.Given the limited number of experiments conducted on reactions related to terbium isotope production,it is necessary to perform theoretical calculations of cross sections over a wide energy range to gain a detailed understanding of terbium isotope production.To achieve this objective,the cross sections of the ^(151)Eu(α,n)^(154) Tb reactions were calculated up to 60 MeV using the TALYS computer code with 432 different combinations of optical model parameters,level density,and strength function models.The theoretical reaction cross-section results were compared with the experimental results in the literature.The best input parameters were determined using the Threshold Logic Unit method,and these parameters were used in all isotope production calculations.Once the optimal model combination was determined,the total activity production and isotopic fraction of ^(152) Tb and ^(155) Tb isotopes were calculated in detail for beam energies of 17–50 MeV,different irradiation times,and varying ^(151) Eu and ^(153) Eu target thicknesses.
基金supported by the National Natural Science Foundation of China(No.12105018)the Beijing Nova Program(Nos.Z211100002121129 and 20230484413)the Beijing Normal University Start-up Grant(No.312232104).
文摘We present a prototype for hybrid Compton and positron emission tomography(PET)imaging aimed at enhancing data utilization and enabling concurrent imaging of multiple radiopharmaceuticals.The prototype comprises two detectors that utilize LYSO-SiPM and were available in our laboratory.One detector consists of a 50×50 array of LYSO crystals,each measuring 0.9mm×0.9mm×10mm with 1 mm pitches,whereas the other detector comprises a 25×25 array of LYSO crystals,each measuring 1.9mm×1.9mm×10mm with 2 mm pitches.These detectors are mounted on a rotational stage,which enables them to function as either a Compton camera or a PET detector pair.The 64-channel signals from the SiPMs of each detector are processed through a capacitive multiplexing circuit to yield four position-weighted outputs.Distinct energy windows were used to discriminate Compton events from PET events.Energy resolution and energy-channel relationships were calibrated via multiple sources.The measured average energy resolutions(full widths at half maximum,FWHMs)for the detectors at 511 keV were 17.5%and 15.2%,respectively.The initial experimental results indicate an angular resolution(FWHM)of 8.6◦for the system in Compton imaging mode.A V-shaped tube injected with 18 F solution was clearly reconstructed,which further verified the imaging capabilities of the system in Compton imaging mode.The results of simulation and experimental imaging studies show that the system can detect tumors as small as 1 mm in diameter when working in PET imaging mode.Mouse bone PET imaging was successfully conducted,with the results matching well with the corresponding CT images.This technology holds great potential for advancing the development of physiological function modalities.