It is not easy to reduce the metal artifacts of computed tomography images.However,the pixel values inside the metal artifact regions vary smoothly,while those on the borders of the metal and the bone regions vary sha...It is not easy to reduce the metal artifacts of computed tomography images.However,the pixel values inside the metal artifact regions vary smoothly,while those on the borders of the metal and the bone regions vary sharply.When the Canny operation by adaptive thresholding is conducted on the raw image,the almost continuous edges can be formed obviously on the borders of the metal and the bone regions,but this kind of information cannot be formed for the metal artifact regions.In this paper,by searching the closed areas formed by the border edges of the bone regions in the Canny image,the metal artifact regions,which are very difficult to discriminate only by intensity thresholding,can be excluded effectively.A novel prior image-based method is thus developed for metal artifact reduction.The experiments demonstrate that the proposed method can be realized easily and reduce the metal artifacts effectively even if multiple large metal objects exist simultaneously in the image.The method is suitable for the clinical application.展开更多
文摘It is not easy to reduce the metal artifacts of computed tomography images.However,the pixel values inside the metal artifact regions vary smoothly,while those on the borders of the metal and the bone regions vary sharply.When the Canny operation by adaptive thresholding is conducted on the raw image,the almost continuous edges can be formed obviously on the borders of the metal and the bone regions,but this kind of information cannot be formed for the metal artifact regions.In this paper,by searching the closed areas formed by the border edges of the bone regions in the Canny image,the metal artifact regions,which are very difficult to discriminate only by intensity thresholding,can be excluded effectively.A novel prior image-based method is thus developed for metal artifact reduction.The experiments demonstrate that the proposed method can be realized easily and reduce the metal artifacts effectively even if multiple large metal objects exist simultaneously in the image.The method is suitable for the clinical application.
文摘目的:主观评价和客观评估不同成像参数下CBCT的图像质量,分析图像质量的主观评价和客观评价间的关系。方法:分别采用6台不同品牌CBCT扫描仪〔3D Accuitomo(Morita)、i-CAT(Kavo)、5G(NewTom)、Smart3D(北京朗视)、DCT Pro(Vatech)、VGi(NewTom)〕,在各个品牌的典型曝光条件下(电压和电流强度不同)扫描空间分辨率模体和高仿真头模,7位医师对拍摄的CBCT图像进行主观评价打分,比较不同CBCT扫描仪的空间分辨率和对常见口腔解剖结构的可见性。客观评价指标采用各仪器所获的图像空间分辩率(LP/mm)。结果:7位医师的组内一致性和组间一致性均无显著性差异。主观评价New Tom 5G为2分,i-CAT为5分,其余4个品牌匀为4分,客观评价i-CAT的LP/mm为1.8,Smart3D为2.0,其余4个品牌为1.0~1.7。在相同管电流条件下,不同管电压的图像主观质量有显著性差异。在相同管电压条件下,不同管电流的图像主观质量有显著性差异。结论:图像质量的主客观评价具有一定的一致性,不同品牌之间的客观评价差异可能与电压、电流强度不同有关。