Glucose,ascorbic acid(AA),uric acid(UA),and dopamine(DA)are vital biomarkers whose dynamic concentrations correlate with critical diseases;however,multiplexed detection remains challenging for conventional electrochem...Glucose,ascorbic acid(AA),uric acid(UA),and dopamine(DA)are vital biomarkers whose dynamic concentrations correlate with critical diseases;however,multiplexed detection remains challenging for conventional electrochemical sensors because of their limited sensitivity and selectivity.Here,we present a millimeter-scale all-poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)(PEDOT:PSS)organic electrochemical transistor(OECT)platform that integrates dual-mode sensing with enzyme/metal-free operation for ultrasensitive biomarker monitoring.By engineering polycrystalline PEDOT:PSS channels via H_2 SO_4 post-treatment,the device achieves record-high conductivity(about(2312.0±29.9)S·cm^(–1)),maximum transconductance(about(2.82±0.12)mS),and on/off ratio(about 210.0±7.8),enabling signal amplification at low gate voltages.The dual-mode strategy combines the selectivity of electrochemistry with the sensitivity of OECTs,realizing simultaneous detection of glucose,AA,UA,and DA with clinical-level sensitivity:detection limits down to 8 nmol·L^(–1)(glucose),0.5 nmol·L^(–1)(AA),5 nmol·L^(–1)(DA),and 0.5 nmol·L^(–1)(UA).Validation using human urine samples yielded recovery rates of 94%–114%.This flexible sensing platform provides a new pathway for the development of wearable biosensors for precision diagnostics.展开更多
Abuse of chloramphenicol(CAP)could cause serious side effects to human health.Therefore,it is necessary to detect CAP residues in animal sourced food effectively.Here,the superiority(better stability,higher Apt-CAP lo...Abuse of chloramphenicol(CAP)could cause serious side effects to human health.Therefore,it is necessary to detect CAP residues in animal sourced food effectively.Here,the superiority(better stability,higher Apt-CAP loading efficiency,and higher CAP binding associated conformational change,etc.)of tetrahedral structure to double-chained structure for developing aptasensor was evaluated.Then,a self-assembled DNA tetrahedral structure-based electrochemical aptasensor targeting CAP was developed.Under the optimized conditions,the aptasensor exhibited high sensitivity toward CAP with a limit of detection(LOD)of 0.0676 ng/m L(linear range 0.19-387.76 ng/m L),and high selectivity against the structural analogs of CAP.Moreover,the recovery rate of CAP from spiked milk samples ranged from 100.57%to 101.69%,and only USD 1.34 is needed for detecting CAP in 1 sample.These results suggested the application potential of this aptasesor for detecting CAP in animal sourced foods.展开更多
基金financially supported by the National Natural Science Foundation of China(Nos.52272214,52372082,52466013,52373184,and U24A20660)Jiangxi Provincial Natural Science Foundation(Nos.20242BAB26059,20232BAB204032,20252BAC200290,20252BEJ730349,and 20252BAC240326)Doctoral Start-Up Fund of Jiangxi Science&Technology Normal University(No.2024BSQD16)。
文摘Glucose,ascorbic acid(AA),uric acid(UA),and dopamine(DA)are vital biomarkers whose dynamic concentrations correlate with critical diseases;however,multiplexed detection remains challenging for conventional electrochemical sensors because of their limited sensitivity and selectivity.Here,we present a millimeter-scale all-poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)(PEDOT:PSS)organic electrochemical transistor(OECT)platform that integrates dual-mode sensing with enzyme/metal-free operation for ultrasensitive biomarker monitoring.By engineering polycrystalline PEDOT:PSS channels via H_2 SO_4 post-treatment,the device achieves record-high conductivity(about(2312.0±29.9)S·cm^(–1)),maximum transconductance(about(2.82±0.12)mS),and on/off ratio(about 210.0±7.8),enabling signal amplification at low gate voltages.The dual-mode strategy combines the selectivity of electrochemistry with the sensitivity of OECTs,realizing simultaneous detection of glucose,AA,UA,and DA with clinical-level sensitivity:detection limits down to 8 nmol·L^(–1)(glucose),0.5 nmol·L^(–1)(AA),5 nmol·L^(–1)(DA),and 0.5 nmol·L^(–1)(UA).Validation using human urine samples yielded recovery rates of 94%–114%.This flexible sensing platform provides a new pathway for the development of wearable biosensors for precision diagnostics.
基金supported by the National Nature Science Foundation of China(82174531)the Medicine and Health Science Technology Development Project of Shandong Province,China(202212060626).
文摘Abuse of chloramphenicol(CAP)could cause serious side effects to human health.Therefore,it is necessary to detect CAP residues in animal sourced food effectively.Here,the superiority(better stability,higher Apt-CAP loading efficiency,and higher CAP binding associated conformational change,etc.)of tetrahedral structure to double-chained structure for developing aptasensor was evaluated.Then,a self-assembled DNA tetrahedral structure-based electrochemical aptasensor targeting CAP was developed.Under the optimized conditions,the aptasensor exhibited high sensitivity toward CAP with a limit of detection(LOD)of 0.0676 ng/m L(linear range 0.19-387.76 ng/m L),and high selectivity against the structural analogs of CAP.Moreover,the recovery rate of CAP from spiked milk samples ranged from 100.57%to 101.69%,and only USD 1.34 is needed for detecting CAP in 1 sample.These results suggested the application potential of this aptasesor for detecting CAP in animal sourced foods.