Room temperature phosphorescence(RTP) signal intensity of eosin-ITC on a polyamide membrane(PM) was very low, but the signal was increased obviously once some inorganic salts were added into the system at λ ex/λ em=...Room temperature phosphorescence(RTP) signal intensity of eosin-ITC on a polyamide membrane(PM) was very low, but the signal was increased obviously once some inorganic salts were added into the system at λ ex/λ em=532 nm/685 nm. The enhancement effect of ⅡA element ions(such as Ca 2+, Sr 2+ and Ba 2+) on RTP of eosin-ITC is much obvious than that of Pb 2+ and Hg 2+ used constantly as an outer heavy atom perturber in phosphorimetry. Based on that, a new solid substrate room temperature phosphorescence immunoassay(SS-RTP-IA) for the determination of the human IgG was proposed to demonstrate the feasibility using eosin-ITC as phosphorescent marker. It was found that a good linear relationship with the ΔI P was obtained when the amount of human IgG in the range from 6.25 to 400 pg/spot(corresponding to the mass concentration: 15.63 ng/mL—1 μg/L, sample volume of 0.4 μL/spot). The regression {equation} of working curve can be expressed as ΔI p=3.062+0.00864x(pg)(n=7, r=0.996), The detection limit calculated as 3S b/k is 0.394 pg/spot. The method was applied directly to the determination of IgG in human serum with a satisfying result. These results show that eosin-ITC can be used conveniently as a RTP marker of high sensitivity.展开更多
基金The National Natural Science Foundation of China(61664014,61627807,81873913,61301038)Natural Science Foundation of Guangxi Province(2015GXNSFBA139041)
文摘Room temperature phosphorescence(RTP) signal intensity of eosin-ITC on a polyamide membrane(PM) was very low, but the signal was increased obviously once some inorganic salts were added into the system at λ ex/λ em=532 nm/685 nm. The enhancement effect of ⅡA element ions(such as Ca 2+, Sr 2+ and Ba 2+) on RTP of eosin-ITC is much obvious than that of Pb 2+ and Hg 2+ used constantly as an outer heavy atom perturber in phosphorimetry. Based on that, a new solid substrate room temperature phosphorescence immunoassay(SS-RTP-IA) for the determination of the human IgG was proposed to demonstrate the feasibility using eosin-ITC as phosphorescent marker. It was found that a good linear relationship with the ΔI P was obtained when the amount of human IgG in the range from 6.25 to 400 pg/spot(corresponding to the mass concentration: 15.63 ng/mL—1 μg/L, sample volume of 0.4 μL/spot). The regression {equation} of working curve can be expressed as ΔI p=3.062+0.00864x(pg)(n=7, r=0.996), The detection limit calculated as 3S b/k is 0.394 pg/spot. The method was applied directly to the determination of IgG in human serum with a satisfying result. These results show that eosin-ITC can be used conveniently as a RTP marker of high sensitivity.
文摘合成了一种有机-无机介孔硅微球材料,以此材料吸附钌联吡啶制备了修饰碳糊电极,并以此电极为工作电极,以Ag/Ag Cl电极为参比电极,铂丝电极为辅助电极,考察了以三丙胺作为Ru(bpy)3^2+共反应剂的电致化学发光性能。基于阿替洛尔对钌联吡啶电致化学发光增强作用,建立了药片及尿样中阿替洛尔含量测定的新方法。该方法对阿替洛尔检出限为0.5μg/m L,线性范围是5~40μg/m L.